Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAdmitted-Finance | ₹5.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.5 Cr+₹1.1 Cr (21.1%)Admitted-Finance 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹6.5 Cr+₹1.1 Cr (21.1%) | L2 | Admitted-Finance |
| 3 | L3₹7.0 Cr+₹1.7 Cr (31.2%)Admitted-Finance 1ST FLOOR SPARTAN HOUSE PLOT NO B29 ROAD NO 18S WAGLE ESTATE THANE W THANE MAHARASHTRA 400604 INDIA | THANE | MAHARASHTRA | 400604 | ₹7.0 Cr+₹1.7 Cr (31.2%) | L3 | Admitted-Finance |
| 4 | L4₹7.2 Cr+₹1.9 Cr (34.9%)Admitted-Finance | ₹7.2 Cr+₹1.9 Cr (34.9%) | L4 | Admitted-Finance |
| 5 | L5₹7.4 Cr+₹2.0 Cr (38.3%)Admitted-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹7.4 Cr+₹2.0 Cr (38.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | PRANAM HVAC ENGINEERING PVT LTD L2 | Purvi Engineers India Pvt Ltd L1 | TRAC FUJICO AIR SYSTEMS LLP L4 | PNEUMATIC ENGINEERS PVT LTD. L5 | BATLIBOI ENVIRONMENTAL ENGINEERING LIMITED L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Note: This Document shall be read in co-ordination with detail specifications Design, Supply Installation Testing & Commissioning of the following: Masonry Spray type Air Washer system (AWS) of air flow capacities mentioned below having a saturation efficiency of 85-90%. The AWS shall consist the following major components-(Note: Civil works not included.). Pl refer drg No. C-CED/EP(AC&V)NFC(K)-149 | ||||||||
| 1.10Supply air Fans : DIDW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. Entire construction shall be epoxy painted. Capacity: 91600 CFM Static Pressure 150 mmWC MOC: Mild Steel Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule ) | ||||||||
| 1.11 | SUPPLY | 2 | Nos | 40,00,000 ₹80,00,000 | 39,88,259 ₹79,76,518 | 25,00,896 ₹50,01,792 | 19,00,000 ₹38,00,000 Lowest | 38,00,000 ₹76,00,000 |
| 1.12 | ERECTION | 2 | Nos | 1,00,000 ₹2,00,000 | 68,775 ₹1,37,550 Lowest | 1,99,383 ₹3,98,766 | 2,00,000 ₹4,00,000 | 2,00,000 ₹4,00,000 |
| 1.20Centrifugal pumps: Water recirculation centrifugal pumps suitable to handle water for above mentioned air flow rate. Accessories: Flexible coupling, mounting frame, etc., MOC: Cast Iron casing with SS impeller Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule) | ||||||||
| 1.21 | SUPPLY | 2 | Nos | 9,00,000 ₹18,00,000 | 1,78,817 ₹3,57,634 Lowest | 2,71,044 ₹5,42,088 | 2,00,000 ₹4,00,000 | 5,00,000 ₹10,00,000 |
| 1.22 | ERECTION | 2 | Nos | 40,000 ₹80,000 | 34,387 ₹68,774 | 28,412 ₹56,824 | 30,000 ₹60,000 | 25,000 ₹50,000 Lowest |
| 1.30Plumbing between Spray chamber and Pumps Piping from spray chamber to/from the pumps. Associated pump accessories : Isolation valves at inlet & outlet, flow regulation valves, NRV/check valve, strainer, etc. Piping from battery limit is also covered in this scope . Necessary fittings : Elbows, tees, couplings, reducers fasteners, clamps.etc, MOC : GI Class B Dwg: "C-CED/EP(AC&V)NFC(K)-147" for reference. | ||||||||
| 1.31 | SUPPLY | 1 | SET | 7,50,000 ₹7,50,000 | 2,54,470 ₹2,54,470 Lowest | 8,78,468 ₹8,78,468 | 5,00,000 ₹5,00,000 | 6,00,000 ₹6,00,000 |
| 1.32 | ERECTION | 1 | SET | 80,000 ₹80,000 | 34,387 ₹34,387 Lowest | 1,03,632 ₹1,03,632 | 1,00,000 ₹1,00,000 | 1,50,000 ₹1,50,000 |
Tender Value
₹7.9 Cr
Closing Date
13 Dec 2021, 2:00 pmClosed
DCE (CED, EP,PD, MS and MPS)
Electrical Projects, 2nd Floor, Saarathi Building, Nuclear Fuel Complex, Hyderabad-500 062
Supply, Installation, Testing and Commissioning of Ventilation System for Assembly Area and Active Waste Storage shed, NFC- Kota
2021_NFC_655721_1
E/629/2021
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
210 days
Rawatbhata
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
14 May 2022
2 Nov 2021
14 Dec 2021
2 Nov 2021
13 Dec 2021
29 Nov 2021
2 Nov 2021 - 16 Nov 2021
Amount
Note: This Document shall be read in co-ordination with detail specifications Design, Supply Installation Testing & Commissioning of the following: Masonry Spray type Air Washer system (AWS) of air flow capacities mentioned below having a saturation efficiency of 85-90%. The AWS shall consist the following major components-(Note: Civil works not included.). Pl refer drg No. C-CED/EP(AC&V)NFC(K)-149
Supply air Fans : DIDW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. Entire construction shall be epoxy painted. Capacity: 91600 CFM Static Pressure 150 mmWC MOC: Mild Steel Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule )
SUPPLY
ERECTION
Centrifugal pumps: Water recirculation centrifugal pumps suitable to handle water for above mentioned air flow rate. Accessories: Flexible coupling, mounting frame, etc., MOC: Cast Iron casing with SS impeller Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule)
SUPPLY
ERECTION
Plumbing between Spray chamber and Pumps Piping from spray chamber to/from the pumps. Associated pump accessories : Isolation valves at inlet & outlet, flow regulation valves, NRV/check valve, strainer, etc. Piping from battery limit is also covered in this scope . Necessary fittings : Elbows, tees, couplings, reducers fasteners, clamps.etc, MOC : GI Class B Dwg: "C-CED/EP(AC&V)NFC(K)-147" for reference.
SUPPLY
ERECTION
Spray Chamber internals: Supply Installation Testing & Commissioning of three bank water spraying system with header, distributers, HDPV nozzles, marine light, pipe fittings, quick fill make up water line along with float and valve, drain pipe with gate valve, etc. MOC : GI Class-B
SUPPLY
ERECTION
Fresh Air Filter Capacity : 2000 CFM Grade : G4 Efficiency : 90% down to 10 micron Filter Media : HDPE Size : 610x610 mm Casing : Aluminium Face guard : Wire mesh type (Note: Necessary support structure is covered in another item)
SUPPLY
ERECTION
PVC Air distributer (Note: Necessary MS support structure is covered in another item).
SUPPLY
ERECTION
Chevron type PVC Mist eliminator (Note: Necessary MS support structure is covered in another item).
SUPPLY
ERECTION
Exhaust air Fans : SISW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. MS construction shall be epoxy painted. Static Pressure: 350 mm WC Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule )
69100 CFM MOC:Mild Steel
SUPPLY
ERECTION
66700 CFM MOC:Mild Steel
SUPPLY
ERECTION
GI DUCTING: Duct shall be complying to IS: 277, Class IV, Grade 275 GSM. Accessories included: Supply/Exhaust air collars, vanes, splitters, necessary MS structural members (viz. angle flanges for duct joining, lateral& longitudinal reinforcement, internal tie rods, fasteners), gaskets, sealent, etc. Duct construction shall be as per IS-655/SMACNA standrad. (Note: Necessary duct supporting/hanging structural material (MS) is covered under item)
22 Gauge, Rectangular
SUPPLY
ERECTION
18 Gauge, Circular
SUPPLY
ERECTION
22 Gauge, Circular
SUPPLY
ERECTION
16 Gauge for plenum
SUPPLY
ERECTION
Manually operated Volume Control Dampers Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
Rectangular, MOC: GI
SUPPLY
ERECTION
Circular, MOC: GI
SUPPLY
ERECTION
Electrically operated Volume Control Dampers for ducting with one of the dimensions 1.0 mtr and above Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
Rectangular, MOC: GI
SUPPLY
ERECTION
Circular, MOC: GI
SUPPLY
ERECTION
Actuators for electrically operated Volume Control Dampers
SUPPLY
ERECTION
Non Return damper MOC: SS 304 Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
SUPPLY
ERECTION
Fusible link type Fire dampers MOC: GI Thickness: 16 G Thick Dimensions: As per Requirement Note: Dampers shall be CBRI tested & certified for minimum 90 minutes rating as per UL 555 Measurement: Cross Sectional Flow Area including flanges
SUPPLY
ERECTION
Supply Air Grills: Type : Double deflection grills/Four Way Diffusers as per layout MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G Accessories : Volume control Dampers
SUPPLY
ERECTION
Return Air diffusers MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G
SUPPLY
ERECTION
MS. Structure (For General purpose): Painting : Epoxy painting with primer Scope: Duct supports, Yard Trustels for carrying ducts, supporting stand.
SUPPLY
ERECTION
MS. Structure(For retainer frames): Painting : Epoxy painting with primer Scope: HEPA filter/ Pre Filter/ Fresh Air filter/Air Distributer/ Mist Eliminator etc
SUPPLY
ERECTION
Pre-Filters Grade : G4 Size: 610x 610 mm Flow Rate: 2000 CFM Efficiency : 95% down to 10 micron Initial Pressure Drop: 12 mmWC maximum in clean condition Casing : 1.2 mm thick Aluminium Media : Non woven Synthetic media sandwiched between 2 layers of HDPE Mesh
SUPPLY
ERECTION
MS Leak tight doors Size : 2.215 x1.115 m Note: For masonary type HEPA/Pre-filter chambers Refer : Drawing no C-CED/EP(AC&V)-142
SUPPLY
ERECTION
1)Developing CAD drgs pertaining to GA, duct layout drawings as per specifications. 2)Simulation of Air flow pattern by CFD analysis using ANSYS or equivalent software. 3) Developing P&ID drgs of all ventilation systems as per schemes given 4) Assessing TAG numbers to all ventilation equipment 5)Validating of total sytem by smoke test.
SUPPLY
ERECTION
Design, Engineering, fabrication, transportation, Safe handling, site storage, Installation, Testing & Commissioning of Fully Draw-out type Motor Control Centre for air blowers and pumps as per tender specifications
Damper Control Panel 4P, 63 A MCCB I/C-1Nos. 1 KW DOL starter(3Phase) - 8 Nos 1 KW DOL starter(1 Phase) - 9 Nos 3P+NL, 32A MCCB --- 1 Nos.
SUPPLY
ERECTION
Design, Engineering, fabrication, transportation, Safe handling, site storage, Installation, Testing & Commissioning of Fully Draw-out type VFD Motor Control Centre for air blowers and pumps as per tender specifications
Assembly section Exhaust MCC 4P, 800A EDO type ACB I/C-2Nos. 4P, 800A EDO type ACB B/C-1No. 200kW VFDs --- 2 No. 3P+NL, 400A MCCBs --- 1 Nos. 11kW DOL Starter --2Nos. 3P+NL, 63A MCCBs --- 2 Nos.
SUPPLY
ERECTION
Assembly Area Supply Air MCC panel (Non-drawout type) 4P, 800A EDO type ACB I/C-2Nos. 4P, 800A EDO type ACB B/C-1No. 3P+NL, 400A MCCBs --- 3 Nos. 110kW VFDs --- 2 Nos. 45kW VFDs --- 2 Nos. 3P+NL, 63A MCCBs --- 2 Nos.
SUPPLY
ERECTION
Active Waste Storage MCC 4P, 800A EDO type ACB I/C-2Nos. 4P, 800A EDO type ACB B/C-1No. 200kW VFDs --- 2 No. 3P+NL, 400A MCCBs --- 3 Nos. 3P+NL, 63A MCCBs --- 2 Nos.
SUPPLY
ERECTION
Supply, installation, testing and commissioning of 1100 V grade, XLPE insulated and armoured FRLS cables of following sizes as per data sheet, specifications of this tender and directions of Engineer-in-Charge. including transport, all labour and materials, complete in all respects.
3Cx185sqmm copper conductor
SUPPLY
ERECTION
3Cx120sqmm copper conductor
SUPPLY
ERECTION
3Cx 70 sqmm copper conductor
SUPPLY
ERECTION
4Cx 16 sqmm Al conductor
SUPPLY
ERECTION
3Cx 16 sqmm copper conductor
SUPPLY
ERECTION
4Cx2.5sqmm copper conductor
SUPPLY
ERECTION
Termination of XLPE insulated armoured Aluminium/Copper power cables (up to 1100 V grade) and connection of leads including the supply of single compression cable glands and heavy duty copper lugs, drilling of suitable holes in equipments for fixing purposes, including fixing of cable glands, supply and fixing of PVC shrouds, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
3Cx185sqmm copper conductor
SUPPLY
ERECTION
3Cx120sqmm copper conductor
SUPPLY
ERECTION
3Cx 70 sqmm copper conductor
SUPPLY
ERECTION
4Cx 16 sqmm Al conductor
SUPPLY
ERECTION
3Cx 16 sqmm copper conductor
SUPPLY
ERECTION
4Cx2.5sqmm copper conductor
SUPPLY
ERECTION
CABLE – TRAYS : Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. tender drawing of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
300 mm wide Straight run cable tray.
SUPPLY
ERECTION
Supply, fabrication and installation of 0.91 mm (20 gauge) GI sheet covers for all sizes cable trays, including necessary hardware, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer- in-Charge.
SUPPLY
ERECTION
PRANAM HVAC ENGINEERING PVT LTD
BATLIBOI ENVIRONMENTAL ENGINEERING LIMITED
TRAC FUJICO AIR SYSTEMS LLP
PNEUMATIC ENGINEERS PVT LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .