DC works
FTR HQ BSF Meghalaya
Repair and maintenance of damaged Indo Bangladesh B S Fence in AOR of 172 BN BSF under SHQ BSF Jowai
2024_BSF_827966_1
29/BSF/FTR/Megh/2024-25
Open Tender
Civil Works
Item Rate
365 days
SHQ BSF Jowai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹75,861
9 Oct 2024
26 Sept 2024
7 Oct 2024
26 Sept 2024
5 Oct 2024
26 Sept 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish , lead up to 50 m and lift up to 1.5 All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.
Supplying and fixing turn buckles and straining bolts for barbed wire fencing. each
Providing and fixing barbed wire of size 2.5mm x2.0mm type lows type (weight to be not less then 108 gms per meter length) conforming to I.S code to I.S code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing to the existing M.S angle iron posts placed at 3.m c/c in 23 horizontal rows (16 rows in vertical portion and 7 rows in slanting portion and strechd with M.S hooks/tighting bolts and also properly inter woven with two sets of cross diagonals as per drawing (one on vertical portion and other on slanting portion) with G.I barbed wire of same sepecification, fixing each row of barbed wire to intermidate angle iron post between tightening bolts with spilt cotter pins of size 5x22 (conferming to IS-549 steel), including providing vertical standard of G.Ibarbed wire of same sepecification properly inter woven with horizontal raw of barbed wire at 150 C/C spacing up to height of seven rows of barbed wire above ground level, each vertical strand adequately tied at three staggered place with G.I barbed wire not less than 16 gauge, applying three coat of alkyd zinc phosphate primer / paint approve brand and manufacture ( first coat of red oxide colour, second coat in grey colour and top coat in black colour) on tightening bolts, hooks & cotter pins, nuts washers & bolts, all as per direction of Engineer-in-charge,(b) India side Row
Providing and fixing G. I. barbed wire, of size 2.5mm x 2.0mm type a lowa Type (weight to be not less than 108 gms per meter length), conforming to I.S. code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing M.S. angle iron posts placed at 3.0 m c/c in 9 horixontal rows and stretched with M.S. Hooks/ tightening bolts, and also properly inter woven with one sets of cross diagonals as per existing pattern or vertical pottion with G.I. barbed wire of same specification, fixing each rwo of barbed wire to intermendiate angle iron post between tighterning bolts with split cotter pins of size 5x22 (conforming to IS-549 steel), including applying three coat of alkyd zinc phosphate primer/paint of approved brand and manufacture (first coat in red oxide colour, second coat in grey colour and top coat in balck colour) on tightening bolts, hooks & coter pins. nuts washers & bolts, all as per direction of Engineer-in-charge. a) Middle Row (old Pattern)
Providing and fixing barbed wire of size 2.5mm x2.0mm type lows type (weight to be not less then 108 gms per meter length) conforming to I.S code to I.S code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing to the existing M.S angle iron posts placed at 3.m c/c in 23 horizontal rows (16 rows in vertical portion and 7 rows in slanting portion and strechd with M.S hooks/tighting bolts and also properly inter woven with two sets of cross diagonals as per drawing (one on vertical portion and other on slanting portion) with G.I barbed wire of same sepecification, fixing each row of barbed wire to intermidate angle iron post between tightening bolts with spilt cotter pins of size 5x22 (conferming to IS-549 steel), including providing vertical standard of G.Ibarbed wire of same sepecification properly inter woven with horizontal raw of barbed wire at 150 C/C spacing up to height of seven rows of barbed wire above ground level, each vertical strand adequately tied at three staggered place with G.I barbed wire not less than 16 gauge, applying three coat of alkyd zinc phosphate primer / paint approve brand and manufacture ( first coat of red oxide colour, second coat in grey colour and top coat in black colour) on tightening bolts, hooks & cotter pins, nuts washers & bolts, all as per direction of Engineer-in-charge,(a) Bangladesh side Row
Providing and fixing galvanized punched tope concertina coil, 1050 mm dia ( when closed weighting not less than 15.2 kg each coil, having galvanized spring cold drawn steel coil wire of 2.5 mm dia, galvanzied punched tope of low carbon steel having series of sharp barbs uniformly punched along its length having 550 nos of barbs on periphery per revolution and crimped on steel spring core wire having G.I steel wire handles hocked to coil for handing & M.S square bars hoocked with coil having pointed face anchorage, duly dipped in anticorrosive bitumastic paint, including spreading each coil uniformly in 10 metre length, including adequately tying to the existing G.I barbed wire fencing with G.I wire of not less then 16 gauge at every 1m spacing, tying the handles of succeeding coil with preceding coil with G.I wire for not less than 16 gauge, proper anchoring of spikes at start and end of the coil with C.C block of size 200 mm x 200 mm in C.C 1:2:4 ( 1 cement 2 coare sand 4 graded stone aggregate 20 mm nominal size ) as par direction of Engineer-in-charge
Proprieter
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .