Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹5.3 L+₹80,020 (17.9%)Rejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹5.4 L+₹97,106 (21.8%)Rejected-Finance 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹5.5 L+₹1.1 L (24.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹5.8 L+₹1.3 L (29.7%)Rejected-Finance N A | NA | NA | 121004 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/s Rohit Construction Co. L1 | RAJENDER ENTERPRISES L4 | SHREE GURU NANAK CONSTRUCTION COMPANY L2 | N.K. CONSTRUCTION COMPANY L5 | AYUSH BUILDERS L6 | J.D INFRA ENGINEERING L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix outdoor type Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 40 KVA including foundation work as per manufacturer recommendation etc complete all as specified and directed. | 1 | Each | 2,00,000 ₹2,00,000 Lowest | 2,72,500 ₹2,72,500 | 2,10,000 ₹2,10,000 | 3,00,000 ₹3,00,000 | 2,50,000 ₹2,50,000 | 2,80,000 ₹2,80,000 |
| 2.00 | Supply and fixing vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. | 1 | Each | 13,000 ₹13,000 Lowest | 13,500 ₹13,500 | 13,250 ₹13,250 | 18,000 ₹18,000 | 14,000 ₹14,000 | 14,500 ₹14,500 |
| 3.00 | Supply and fixing MCB SP 6- 32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. | 33 | Each | 150 ₹4,950 | 140 ₹4,620 Lowest | 170 ₹5,610 | 205 ₹6,765 | 165 ₹5,445 | 160 ₹5,280 |
| 4.00 | Supply and fixing ELCB/RCCBs SPN 32 Amps 240Volts, complete all as specified and directed. | 3 | Each | 3,000 ₹9,000 | 3,100 ₹9,300 | 4,000 ₹12,000 | 3,650 ₹10,950 | 3,300 ₹9,900 | 2,450 ₹7,350 Lowest |
| 5.00 | Supply and fixing Surge Protection Device(SPD) SPN 32 Amps 240Volts, complete all as specified and directed. | 3 | Each | 2,000 ₹6,000 Lowest | 2,025 ₹6,075 | 2,800 ₹8,400 | 2,500 ₹7,500 | 2,400 ₹7,200 | 2,450 ₹7,350 |
| 6.00 | Supply and fixing MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. | 3 | Each | 500 ₹1,500 | 450 ₹1,350 Lowest | 600 ₹1,800 | 600 ₹1,800 | 550 ₹1,650 | 500 ₹1,500 |
| 7.00 | Supply and fix MCB DB single pole and neutral 240 volt SPN 8 way with 200 Amps rated bus bar double door type complete all as specified and directed. | 3 | Each | 1,500 ₹4,500 Lowest | 1,560 ₹4,680 | 1,800 ₹5,400 | 2,000 ₹6,000 | 1,620 ₹4,860 | 1,500 ₹4,500 Lowest |
| 8.00 | Supply and fix MCB DB single pole and neutral 240 volt SPN 12way with 200 Amps rated bus bar double door type complete all as specified and directed. | 3 | Each | 3,000 ₹9,000 | 3,045 ₹9,135 | 3,500 ₹10,500 | 4,000 ₹12,000 | 3,200 ₹9,600 | 2,000 ₹6,000 Lowest |
| 9.00 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit 25mm dia ISI marked and accessories surface fixed on wall /floor et ccomplete all as specified and directed.
Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes. | 75 | RM | 350 ₹26,250 | 380 ₹28,500 | 425 ₹31,875 | 450 ₹33,750 | 320 ₹24,000 Lowest | 500 ₹37,500 |
| 10.00 | M&L for Earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers up to 90 cm and with tibba sand up to top level and electrode connected to copper strip 20 x 3 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment / copper strip for lightning arrestor all as shown in electrical plate No. 5 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 35 mm x 35 mm x 3 mm, complete all as specified and directed.
Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point.
(ii) Earth pit shall be constructed minimum 0.5 metre away from earth. | 2 | Each Job | 25,000 ₹50,000 | 26,500 ₹53,000 | 31,250 ₹62,500 | 38,000 ₹76,000 | 28,500 ₹57,000 | 22,500 ₹45,000 Lowest |
Tender Value
₹4.8 L
EMD Value
₹10,000
Closing Date
16 Jun 2026, 6:00 pmClosed
GE AF NAL
GE AF NAL
As mentioned and described in BOQ
2026_MES_768081_1
GE (AF) NAL /T-36/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE AF NAL
As per NIT and tender documents class E and above and category b (i)
9 documents required · 9 mandatory
₹500
GE AF NAL
₹10,000
Yes
22 Jul 2026
26 May 2026
18 Jun 2026
26 May 2026
16 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fix outdoor type Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 40 KVA including foundation work as per manufacturer recommendation etc complete all as specified and directed. | 1 | Each | 10 | ₹10 |
| 2 | Supply and fixing vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. | 1 | Each | 1.25 | ₹1.25 |
| 3 | Supply and fixing MCB SP 6- 32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. | 33 | Each | - | - |
| 4 | Supply and fixing ELCB/RCCBs SPN 32 Amps 240Volts, complete all as specified and directed. | 3 | Each | 22 | ₹66 |
| 5 | Supply and fixing Surge Protection Device(SPD) SPN 32 Amps 240Volts, complete all as specified and directed. | 3 | Each | 22 | ₹66 |
| 6 | Supply and fixing MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. | 3 | Each | - | - |
| 7 | Supply and fix MCB DB single pole and neutral 240 volt SPN 8 way with 200 Amps rated bus bar double door type complete all as specified and directed. | 3 | Each | 22 | ₹66 |
| 8 | Supply and fix MCB DB single pole and neutral 240 volt SPN 12way with 200 Amps rated bus bar double door type complete all as specified and directed. | 3 | Each | 22 | ₹66 |
| 9 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit 25mm dia ISI marked and accessories surface fixed on wall /floor et ccomplete all as specified and directed.
Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes. | 75 | RM | 10 | ₹750 |
| 10 | M&L for Earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers up to 90 cm and with tibba sand up to top level and electrode connected to copper strip 20 x 3 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment / copper strip for lightning arrestor all as shown in electrical plate No. 5 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 35 mm x 35 mm x 3 mm, complete all as specified and directed.
Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point.
(ii) Earth pit shall be constructed minimum 0.5 metre away from earth. | 2 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tender36.pdf
Tender Documents • 2.72 MB
BOQ_860152.xls
BOQ • 0.30 MB
BOQCorrgdm36.pdf
PDF • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .