Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.1 Cr+₹4.7 L (4.33%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹1.1 Cr+₹4.7 L (4.33%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.2 Cr+₹15.6 L (14.4%)Rejected-Finance NOT AVAILABLE | ₹1.2 Cr+₹15.6 L (14.4%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹1.3 Cr+₹26.3 L (24.3%)Rejected-Finance | ₹1.3 Cr+₹26.3 L (24.3%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹1.4 Cr+₹33.4 L (30.9%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹1.4 Cr+₹33.4 L (30.9%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
20 Nov 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIR TO BUILDING NO P-68 (NURSING CADET ACCN) AT INHS ASVINI
2024_MES_680162_1
8064/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) Asvini
Class B cat a(i)
7 documents required · 7 mandatory
₹1,000
AGE I ASVINI
₹2.2 L
Yes
6 Jan 2025
18 Oct 2024
22 Nov 2024
18 Oct 2024
20 Nov 2024
8 Nov 2024
18 Oct 2024 - 6 Nov 2024
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including RCC water tanks on roof of G+6 storey bldg , reinforcement cut as required to facilitate demolition and separating, scraping and cleaning of reinforcement and removing debris outside MD land. Note :- (i) The quoted rates shall deemed to include providing safety arrangements,necessary scafolding and binding safety mesh all around the building to arrest the falling debris as directed by Engineer-in-Charge. (ii) Item No 01 to 101 shall be executed from ground level to 30mtr height in different locations of building and quoted rate shall deemed to be included all safety measures, necessary scaffolding ,safety mesh to arrest falling debries.
Material & labour for relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by providing adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement as per site conditions and considering the load complete to the satisfaction of Engineer- in- charge. Note-Removing and redoing of brickwork if required shall be measured and paid separately
Material & labour for chipping out carefully existing loose, damaged concrete from RCC members i.e. columns, Beams, Slabs and Chajjas on External and internal areas beyond main reinforcement if required in the opinion of the Engineer-in-Charge by low impact hammer, chisel without damaging the structure ( hard concrete should not be removed by force), cleaning with wire brushing reinforcement and concrete to remove all dust and cleaning with water, applying ‘Rusticide SS’ Rust passivator to existing reinforcement bars and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” and cement in proportion 1:1.5 to existing reinforcement bars, applying bonding coat of slurry made out of “Polyalk EP” and cement in proportion 1:1 to concrete and reinforcement and applying “Polyalk EP” Polymer modified cement mortar in proportion of (1:5:15) to RCC members and finishing the surface rough to receive plaster including curing complete all as per manufacturers instructions and as directed including removing debries out side MD land . Note: The place of disposal shall be find out by the contractor.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Demolition of sunken portion of any description including floor tiles, lime/cement concrete, APP bitumen membrane,screed bed,soil pipes,gratings,WC/IWC,spouts and anything found during demolition of sunken portion and cleaning the surface with wire brush to remove dirt, dust , cleaning with water complete all as specified by Engr-in-charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles including copings etc.and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Taking down carefully by Chiseling/ Chipping out all existing loose decayed Plaster from external wall, internal wall, plumbing duct areas and roof areas (In patch work) using Plaster Breaking machine and or Well sharpened Chisel & Hammers at proper angles and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Dismantling cast iron work in of any description and in any position complete all as specified and directed by Engr-in-charge. Note:- The item includes rain water pipes, sewage pipes, drain pipes and sunken fittings etc complete.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sq.m each complete all as specified and directed by Engr-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq.m and not exc 4 sq.m each complete all as specified and directed by Engr-in-charge.
Material & labour for dismantling wrought iron or mild steel work or TMT bars of any description and in any position complete all as specified and directed by Engr-in- charge.
Material & labour for 80mm bore ( internal dia) Mild steel tubular poles having minimum thickness 4mm in vertical posts/truss or welded horizontally including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 all as directed by Engr-in-charge. Note : The work shall be carried out in roof of 6th floor (35mtr above the ground level) with all safety arrangements including pulling arrangement without damage to the existing structure.
Supply & fixing mild steel plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without any attachment including all necessary drilling, bolting,riveting or welding conforming to Fe 410 -W (Gde E- 250) quality-A complete all as specified. Note : The work shall be carried out in roof of 6th floor (35mtr above the ground level) with all safety arrangements including pulling arrangement without damage to the existing structure.
Material & Labour for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 -W (GdeE- 250) quality A complete all as specified and directed. Note : The work shall be carried out in roof of 6th floor (35mtr above the ground level) with all safety arrangements including pulling arrangement without damage to the existing structure.
Supply & fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall or in angle iron chajja etc fixed with self tapping screws as specified and directed by Engr-in-charge. Note : The work shall be carried out in roof of 6th floor (35mtr above the ground level) with all safety arrangements including pulling arrangement without damage to the existing structure.
Material & labour for MS hand rails, half round or other stock section or core for wooden hand rail straight portion drilled and countersunk for balusters running bars, for doors balusters, nosing to steps including embedding in concrete and screwing etc wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified. Note : The work shall be carried out in roof of 6th floor (35mtr above the ground level) with all safety arrangements including pulling arrangement without damage to the existing structure.
Material & labour for mild steel Framed work such as grills, gratings, or framing for CGI sheet chajja etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Material & labour for opening the Separation Cracks at the Junction of RCC and Masonry into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks and 20-25mm wide and 15-20mm in depth by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer , including Wire brushing and washing with water jet to the satisfaction of the Engineer-in- Charge.
Material & labour for Moistening the Cracks and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement in proportion 1:1 to surfaces prepared, Filling the Cracks /Grooves with “Polyalk EP” Polymer modified cement mortar in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing in level of existing plaster including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed.
Material & labour for TMT (CRS) bars of appropriate size where 20% of cross section is reduced including application of rust converter FEOVERT and applying protective coating IPNET-RB including cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia to new reinforcement or welding of steel reinforcement where required complete all as per manufacturers instructions and as directed by Engr-in-charge.
Material & labour for Drilling holes upto 16 mm Diameter and up to 50mm depth in concrete, Cleaning of holes by air blower prior to fixing nozzles, fixing 12 mm dia aluminum /PVC injection nipples and securing the same as directed & injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Material & labour for providing and fixing 12 mm dia aluminium /PVC injection nipples and securing the same as directed and injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ at the rate of 225 grams per bag of cement using suitable mechanical gun/pump to ensure complete sealing, cure the system for min.12 hrs, Cut the nozzles by chisel after completion of grouting without damaging structural elements complete all as per manufacturers instructions and as directed by Engineer-in-Charge..
Material & labour for Jacketting around sides of existing column with Micro concrete (Molith-MC) M40 with uniform thickness of 115 mm or as directed at any height including all lifts, shuttering,scaffolding etc complete all as per manufacturers instructions and as directed by Engr-in-charge. Note: i) Reinforcement shall be measured and paid separately. ii) Rates quoted shall deemed to be included jacketing, formwork and micro concrete.
Material & labour for providing & fixing shear anchor epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns including drilling holes and fixing before jacketing, Micro concreting as directed by Engineer-in-Charge.
Material & labour for applying/ laying Super fluid Microconcrete - Roffecrete mixed with 5mm to 10mm size aggregates on the bottom of beams, slabs etc.including waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification and as directed by Engr-in-charge. Note -The item shall be paid on actual consumption of Micro concrete and record shall be submitted alonwith RAR.
Material & labour for Jacketting around sides of existing RCC Pardis and elevation band with Micro concrete (Molith-MC) M40 with uniform thickness as directed at any height including all lifts, shuttering,scaffolding etc complete all as per manufacturers instructions and as directed by Engr-in-charge. Note: i) Reinforcement shall be measured and paid separately. ii) Rates quoted shall deemed to be included jacketing, formwork and micro concrete.
Material & labour for Carefully Chiseling/ Chipping out existing cracked /damaged IPS(Indian patent stone) and Providing I.P.S. Finish (1:1.5:3) over roof/Chajja Tops (need based areas) laying Brick bats/ Metal pieces to the desired thickness (as directed by Engr-in-charge) and slope finished with cement mortar plaster of specified and required thk. in CM (1:4), with neat cement slurry including waterproofing compound, curing etc including making junction wattas etc complete as specified and directed.
Material & labour for PCC 1:3:6 type C1 using (20 mm graded stone aggregate) in roof kerbs, mud stops, rounded or chamfered on edges on sloping roof at height upto 20 mtr from GL complete all as specified and directed.
Supply & fixing 100mm bore CI soil, waste and vent pipes spun pipes with or without ears with cement joints and fixed to walls with suitable size GI clamps including dismantling existing CI pipes with fittings , jointed in cement mortar in any situation and in any position including all fittings complete all as specified .
Supply & fixing 75mm bore CI soil, waste and vent pipes spun pipes with or without ears with cement joints and fixed to walls with suitable size GI clamps including dismantling existing CI pipes with fittings, jointed in cement mortar in any situation and in any position including all fittings complete all as specified .
Supply & fixing 100 mm bore cast iron bend (any radius) with oval access doors fixed to CI soil and vent pipe and jointing with cement mortar complete all as specified.
Supply & fixing 75 mm bore cast iron bend (any radius) with oval access doors fixed to CI soil and vent pipe and jointing with cement mortar complete all as specified.
Supply & fixing 100mm bore CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and jointing with cement mortar complete all as specified.
Supply & fixing 75mm bore CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and jointing with cement mortar complete all as specified.
Supply & fixing 100mm bore CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and jointing with cement mortar complete all as specified.
Supply & fixing 75mm bore CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and jointing with cement mortar complete all as specified.
Supply and fix 100mm bore cast iron 'S' or 'P' traps jointing with run lead complete all as specified and directed by Engr-in-charge.
Supply & Fixing in repair cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1, diameter of outlet 100mm bore complete all as specified and directed by Engr-in-Charge .
Supply & fixing stack clamps made out of 50mm by 5mm MS flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 100mm bore pipe complete all as specified.
Supply & fixing stack clamps made out of 50mm by 5mm MS flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 75mm bore pipe complete all as specified.
Material & labour for rendering 15mm thick on fair faces of brickwork or concrete surfaces in CM 1:4 in floors/walls of sunken portion complete all as specified and directed by Engr-in-charge .
Material & labour for preparing sunken portion of RCC floors slab and walls upto 1 mtr height by wire brush to remove all lataince & loose particles like cement mortar deposits, dirt, dust etc., Oil & grease, if any, shall be de-greased with suitable solvents and finally cleaning with water and applying Dr. Fixit Bathseal as per manufacturers instructions and comprises of the following activities Application :- i) Cracks, caevites & gaps shall be filled with cement sand mortar (1:3) mixed with Pidicrete URP as per manufacturers instructions and angular fillet of size 50 mm x 50 mm shall be laid at junction of floor and wall with cement sand mortar (1:3) mixed with Pidicrete URP as per manufacturers instructions (ii) Apply first coat of Dr. Fixit Bathseal in floor of sunken and wall upto 1mtr ht. (ii) While the coating is still wet place the glass fibre mesh (2.5 mm x 2.5 mm) on the angle fillet extending about 50 mm on floor surface and 50 mm on walls and allow it to soak completely with material. (iii) Before the coating dries apply immediately another coat of Dr. Fixit Bathseal 2K only on the angle fillet completely covering the mesh thus embedding it firmly between two coats of Dr. Fixit Bathseal 2K. (iv) Allow the coating to dry completely for 6 to 8 hrs before applying second coat all over the floor area and walls. (v)The angle fillet area now has three coats of Dr. Fixit Bathseal 2K with mesh embedded firmly within the coating. (vi) Allow the coating to dry completely for 3-4 days. Do not cure with water but keep coating moist using wet hessian cloth. (vii) Test the water proofing area by filling water for 72 hours and tested for leakage/seepage to the entire satisfaction of Engineer-in-Charge . If leakage/Seepage occured after filling water, the above treatment shall be re-done completely without any extra cost.
Material & labour for 70mm thick cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate), in sunken portion complete all as specified and directed by Engr-in-charge.
Material & labour for cement concrete 1:5:10 type E-2(using 40mm graded stone aggregate) for filling in sunken portion complete all as specified and directed by Engr-in-charge.
Material & labour for 40mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in sunken portion floor complete all as specified and directed by Engr-in-charge.
Material & Labour for Non skid coloured ceramic tiles 7 to 8 mm thick (square/Rectanglar) area of each tiles exc 0.18 Sqm but n exc 0.38 Sqm laid in floor over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified.
Material & Labour for coloured glazed ceramic tiles 300mm x 200mm x 7mm thick but laid on vertical surfaces such as skirting/dado laid over and including 10 mm thick backing coat in CM (1:4), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified.
Material & Labour for light shade vitrified ceramic tiles 10 mm thick (square /rectangular ) polished dark shade, area of each tiles not exceeding 0.36 sqm, in floor laid in floor over and including 15mm thick screed bed or bedding layer in cement mortar ( (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified.
Supply & fixing 15 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.
Supply & fixing 20 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.
Supply & fixing 25 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.
Supply & fixing 40 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.
Supply and fixing 40mm bore PVC spout in sunken portion to drain out the retain water or in balconies to drain out the retain water of n exc 300mm from outside the wall including sealing the joint with waterproof solution complete all as specified and directed
Material & labour for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engr-in-charge.
Material & labour for rendering 15mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces and finished even & smooth without using extra cement completed all as specified.
Material & labour for rendering 10mm thick in cement mortar 1:3 on fair faces of concrete surfaces in ceiling and finished even & smooth without using extra cement completed all as specified.
Material & labour for Providing and applying 25 mm thick sand faced plaster in two coats on fair faces of brick or concrete surfaces on external wall facades using approved screened and Pre washed River sand with base coat of 15mm thick in C.M. 1:4 finished rough to receive final coat, curing the area for not less than three days and applying finishing coat 10 mm thick in cement mortar 1:4 with sand face finish as specified in clause 14.21 of SSR part I, curing for 7- 10 days including necessary scaffolding and safety arrengement complete all as specified. Note :- i) Cement mortar in both coats shall be mixed with integral water proofing compound @ 3% by weight of cement. ii) Water proofing compound shall be measured and paid separately.
Material & labour for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as specified and directed by Engineer-in-charge :
Supply only liquid water proof compound Note- Contractor shall brought liquid water proof compound in sealed pack drum of capacity 20 kg each and deposited in MES store yard before incorpating in the work.
Material & labour for prepration new or previously untreated steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of 'Anti rust' paint over a coat of red oxide primer complete all as specified and directed.
Material & labour for preparation of old painted steel or iron surfaces of any description and in any position, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & labour for preparation of previously untreated wooden surfaces of any description and in any position, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material & labour for providing and injecting chemical emulsion for Post construction Antitermite Treatment along external wall below concrete or masonory apron using chemical emulson at the rate of 2.25 litres per linear metre including drilling and plugging holes etc in apron and making good disturbed surfaces as per existing complete all as specified and directed.
Material & labour for providing and injecting chemical emulsion for Post construction Antitermite Treatment of voids in masonry using chemical emulson at the rate of one litre per hole at 300mm intervals including drilling holes 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors/wall surface complete all as specified and directed.
Material & labour for Providing and injecting chemical emulsion for post construction antitermite treatment at the points of contact of wood by chemical emulsion (in oil or kerosene based solution) @ 0.5 ltr/hole by drilling 6mm dia holes at down ward angle of 45 degree at 50mm C/C & sealing the same complete all as specified and directed by Engineer-in-Charge
Material & labour for laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application above the boarding of roof to arrest leakage including removal of previous APP membrane and preparing surfaces complete all as specified and directed by Engr-in-charge.
Material & labour 20mm thick machine cut machine polished granite (of any type) tiles machine cut, in Jams and cills of windows,steps of stairs, inside cupboard for slab, laid over and including 20 mm thick screed bed in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
Supply & fixing powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/track and fixing to walls/floors with necessary lugs, cleats etc including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified Note: - (i) Minimum thickness of powder coating shall be 50 micron. (ii) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05 and sill to be provided as per HQ CE(N) MZ TD of sill type 'A' and 'B' respectively if directed.
Supply & fixing Powder coated Anodised aluminium for door, window and ventilator shutters, sliding or fixed type without sash bar, aluminium section minimum weighing 0.55 kg/m including all accessories such as glazing clips, handles, tower bolts,screws, rollers rubber beadings, for fixing glass panes in frame . Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. Note: - (i) Glass panes will be measured & paid separately. (ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight. (iii) Minimum thickness of powder coating shall be 50 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area. (v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05 and sill to be provided as per HQ CE(N) MZ TD of sill type 'A' and 'B' respectively if directed.
Supply and fix metal body concealed handel-cum-latch 100mm long for sliding window shutter made with aluminium and durable plastic long lust and anti rust materials with brackets and screws complete all as specified and directed by Engr-in-charge.
Supply & fixing bearing/roller with metal body having plastic roller screwed to shutter of aluminium windows complete all as specified and directed.
Supply & fixing 4.80 mm thick sheet glass ordinary quality and glazing with aluminium beading and rubber gasket etc in square n exc 0.50 sqm in each pane complete all as specified and directed by Engr-in-charge.
Material & labour for preparing wall surfaces and applying two coats of smart care Damp sheath exterior paints over a coat of base coat of primer all as per manufacturers instructions including scaffolding and necessary safety arrangement as directed by Engr-in-charge. Note -i) Work shall be carried out at some places upto a height of 35 mtr from ground level . ii) Treatment shall be carried through approved applicater and as per manufacturers instructions
Material & labour for preparing new plastered surfaces of wall, applying one coat of wall care putty not less than 2mm thickness and making the surface even and smooth using emery paper and applying two or more coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
Supply & fixing precast reinforced cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings set in CM 1:4 complete all as specified and directed by Engr-in-charge.
Material & labour for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified.
Supply & fixing aluminium anodised barrel tower bolts of extruded section, 100 mm length, ISI marked.
Supply & fixing aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, 300 mm long , ISI marked.
Supply & fixing Butt hinges 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21, ISI marked
Supply & fixing extruded aluminium alloy handles, fabricated type, anodised 100 mm size, ISI marked.
Supply & fixing aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperature 1.00mm and fixed with aluminium windows shutters with wire staples etc complete all as specified and directed by Engr-in-charge
Supply & fixing in repairs vitreous china wash down water closet pan (Pedestal pattern) white, including 'P' or 'S' trap and matching plastic sheet cover, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium anodized hinging device and making all connections complete all as specified.
Supply & fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm bore pipe including 1.2 mtr hose pipe and wall hook including all connections , ISI marked complete all as specified and directed
Supply & fixing in repairs low level PVC flushing cistern (coloured) heavy duty, 10 Ltrs capacity, syphonic action type complete with inlet, ball valve, float and handle including cast iron bracket and 32 mm bore PVC flush pipe and connecting to WC complete all as specified.
Supply & fixing in repairs wash hand basin vitreous china flat black type of size 630 mm x 450 mm white, including CI brackets,32 mm dia PVC waste coupling including cutting for and pining in ends of bracket and connecting up supply pipes, waste or taps complete all as specified
Supply & fixing in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm.
Supply & fixing in repairs PVC waste pipe 40mm bore 90cm long with waste coupling complete all as directed
Supply & fixing in repairs Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges and fixed with CP brass screws.
Supply & fixing in repairs 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified.
Supply & fixing in repairs 15 mm bore angle cock, cast copper alloy, fancy type chromium plated screwed down, high pressure , with lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipes or union.
Supply & fixing in repairs 15 mm bore chromium plated pillar taps fancy type complete all as specified
Supply & fixing in repairs 125 mm dia shower rose, brass chromium plated with swivel joints and fixing to 15 mm bore steel water tubing .
Supply & fixing aluminium anodised DECO grill 10mm thk, DG-104 fixed with necessery U/F/H channel, including cutting for handles, tower bolts etc and providing U clip concealed the rough edges etc complete all as directed
Supply & fixing in repairs Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification and drawings shown in SSR Part II complete all as specified and as directed by Engr-in-Charge.
Supply & fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawings shown in SSR Part II complete all as specified and as directed by Engr-in-Charge.
Supply & fixing Factory made single extruded WPC (wood polymer composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (Maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), miniumum compressive strength 50 N/mm2, modules of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessay full body threaded star headed counter sunk S.S screws, all as per direction of Engr-in-chare.
Supply & fixing for Factory made single extruded WPC (wood polymer composite) solid door frame/chowkhat of size 50 x 100mm comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (Maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum density of 750 kg/cum and screw withdrawal strength of 2200 N (face) & 1100 N (Edge), miniumum compressive strength 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required and length as per specification and drawings shown in SSR Part II complete all as specified and as directed by Engr-in-Charge. Note- MS hold fast/lugs or SS dash fasterners shall be measured and paid seperately.
Supply & fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified
Supply & fixing Anchor bolt fastener rust proof rowel bolt of appropiate size fixing MS plates in surface of roof for erection of CGI sheet complete all as specifed and approved by Engr-in-charge.
Supply & fixing harrison rails, (Curtain rails) mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr-in-charge.
Material & labour for fixing rain water pipes CI/PVC of 100/150mm dia including chipping out the roof joint minimum 1' x 1ft and refixing the same with proper cement Mortar 1:3 mixed with and including WPC @ 3% by weight of cement complete all as specified and directed by Engr-in-charge.
Material & labour for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified.
SCHEDULE 'A' PART II ( E/M WORKS) Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
Material & labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size PVC casing capping heavy grade (ISI marked) with all accessories and terminated in and including PVC modular metal flush box with modular white cover plate with frame of sutable size including 1.5 sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for One light/ fan point controlled by one switch 5 Amp, SP, one way 240 volts. Note: (i) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green.
-Ditto- as per item No 105.00 above but One 3 pin 5 Amps switch socket on same board
-Ditto- as per item No 105.00 above but One 3 pin 5 Amps switch socket on independent board.
Material & labour for point wiring with 4 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size PVC casing capping heavy grade (ISI marked) with all accessories and terminated in and including PVC modular metal flush box with modular white cover plate with frame of sutable size including 4 sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for for one 3 pin socket outlet 15 Amps on the independent board. Note: (i) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green.
Supply & fixing ceiling rose surface bakelite 65 x 50mm, three terminals ISI (Marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Modular switch 1 way 6 Amps, 1 module complete all as specified.
Supply & fixing Modular Socket, 6 Amps 2/3 pin combined 2 module, complete all as specified.
Supply & fixing Modular socket 6Amps/ 16Amps, 2/3 pin combined 2 module 3 module flush type with indicator fuse complete all as specified.
Supply & fixing Modular switch 1 way 15 Amps, 1 module complete all as specified.
Supply & fixing modular stepped type fan regulator, 120Watts - 2 module complete all as specified and directed.
Supply & fixing in repairs MCB Single Pole Neutral sheet metal enclosure, double door DB 8 Way, 200 Amps rated bus bar for each phase, 240 volts with din rail, Neutral and Earthing bar and making good the disturbed surfaces as per existing complete all as specified and as directed.
Supply & fixing in repairs MCB Single Pole Neutral sheet metal enclosure, double door DB 12 Way, 200 Amps rated bus bar for each phase, 240 volts with din rail, Neutral and Earthing bar and making good the disturbed surfaces complete all as specified and as directed.
Supply & fixing in repairs MCB Triple Pole Neutral sheet metal enclosure, double door DB 4 Way (4+12) with 200 Amps rated bus bar for each phase, 415 volts with din rail, Neutral and Earthing bar and making good the disturbed surfaces complete all as specified and as directed.
Supply & fixing in repairs 415 Volts, 10 KA, "C" curve minature circuit breaker (MCB) of TPN 40 to100 Amp current carring capacity fixed in the DB complete all as specified and as directed.
Supply & fixing in repairs 240 Volts, 10 KA, "C" curve minature circuit breaker (MCB) of SP upto 32 Amp current carring capacity in the MCB DB complete with the connection testing and commisioning, complete all as specified and as directed.
Supply & fixing in repairs 240 Volts, 10 KA, "C" curve minature circuit breaker (MCB) of SPN 40 to 63 Amp current carring capacity in the MCB DB complete with the connection testing and commisioning, complete all as specified and as directed.
Supply and fixing in repairs LED light fitting 1 x 20W, 4 feet, 220V, not less than 120 lumen per watt, AC decorative box type with driver, holder and LED tube light including two Nos PVC box of size 75x75x20mm for mounting light fittings and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Material & labour for sub-main wiring with 2 runs of 6 Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn through and including heavy grade PVC casing capping 32x12mm isi marked with all accessories as required, including one run of 6 Sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains connected with thimble from main DB to sub main DB including taking down existing submain wiring and making good distrubed surfaces as per existing complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 6 Sqmm cable, One run of 6 Sqmm earth cable and PVC casing capping shall be measured and paid as one length only.
Supply and fixing Exhaust fan steel body AC single phase, 230volts, 50Hz of size 300mm sweep (12") with blades, frames and louvers including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in repairs BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 volts, 50 Hz,1200mm sweep (48"), minimum air delivery 210 CFM with service value 6.0 BEE Five star rated (latest lable period) with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable for suitable size complete all as specified and as directed. Note :- Old ceiling fan shall be handed over to MES Stores.
Cutting hole in existing concrete or brick wall suitable for fixing 300mm sweep exhaust fan and making good the hole with plaster 15mm thick in CM (1:4) on inside and outside the hole complete all as specified and directed by Engr-in-Charge.
Cutting/drilling in existing RCC ceiling slab surface suitable for fixing with stainless steel super heavy duty 'S' hook specially designed to hang ceiling fan safe load pull out load in 75 kgs and jurk/vibration load is 40 kgs, including making good disturbed surfaces as per existing including taking down old hook complete all as specified and directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated ( Latest lable period, standing losses as per IS Code No. IS 2082 (Latest amendments)) complete with all accessories such as safety valve, thermostate, NRV, connection piece with fixing wall through proper nut, bolt ,fastner with three core 2.5sqmm wire proper connected to top plug completeall as specified . Note :- Old water heater handed over to MES Stores Make:Bajaj/Havells/Racold.
Supply and fixing Air circulator wall Mounted Fan made steel body AC single phase, 230volts, 50Hz of size 600 mm sweep with blades, Speed 1440 RPM, Air Delivery 125 CMM, Power 100W, including connecting up with three core flexible copper conductor cable for suitable size and fixed in wall with propper hanging use high quality nut bolt complete all as specified and as directed.
Supply and fixing in repairs Exhaust fan for toilet made by sturdy Engineering plastic AC single phase, 230volts, 50Hz of size 300mm sweep (12") with blades, frames and louvers, Speed 1325 RPM, Air Delivery 500 CMM, Power 31W, including connecting up with three core flexible copper conductor cable for suitable size, complete all as specified and as directed. Note :- Old exhaust fans handed over to MES Stores.
ASHOK CONSTRUCTION (BID ID -3164588)
SHREE JAGDISH FURNITURE CO. (BID ID -3161978)
Shetty Construction Co (BID ID -3163896)
AGRAWAL ASSOCIATES (BID ID -3161115)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .