Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹28.8 L+₹77,881 (2.78%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹32.4 L+₹4.4 L (15.6%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹35.6 L+₹7.6 L (27.3%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹38.5 L+₹10.5 L (37.4%)Rejected-Finance MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
3 Jan 2023, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
SPECIAL REPAIR TO EXTERNAL ELECTRIFICATION AND INTERNAL WIRING AND CONNECTED FITTING AND FIXTURE OF SCHOOL BUILDING OF K V COD UNDER AGE (E/M) OF GE (EAST) JABALPUR
2022_MES_567387_1
8498/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D b (i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (East) Jabalpur
₹89,000
Yes
10 Mar 2023
7 Dec 2022
5 Jan 2023
7 Dec 2022
3 Jan 2023
21 Dec 2022
7 Dec 2022 - 14 Dec 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, power point or bell point etc) complete including fixture and fitting such as switches, ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unservicable distribution boards by disconnection of electric connection carefully SPN DBs/TPN DBs/main Switch including old unserviceable MCCBs/MCBs, Isolators, etc and making good to disturbed surface etc complete all as specified and directed.
Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/ connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm FRLS PVC insulated and unsheathed single core multistranded copper conductor cable for working voltage 1100 volts, grade drawn into and including 20/25 mm dia PVC casing caping of medium grade for one light/fan point controlled by one switch including 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor and connecting to earth dolly & to be terminated in & inclusive of MS sunken box 1.2 mm thick (flush metal box) for mounting of fittings like switch, socket , fan regulator etc complete with 3mm thick laminated switch board cover all as specified and as directed.
All as per item No 4 above but for One ceiling fan point controlled by one switch complete all as specified by the Engineer-in-Charge.
All as per item No 4 above but for One 3 Pin, 5/6 amps socket outlet point, on the same board with 1.5 Sqmm cable size etc complete all as specified and as directed.
All as per item No 4 above but for One 3 Pin, 5/6 amps socket outlet point, independent board with 1.5 Sqmm cable size etc complete all as specified and as directed.
All as per item No 7 here-in-before but 2.5 Sqmm copper conductor for 5 Pin 15 Amp switch socket combintion on independent board and 2.5 Sqmm stranded copper conductor as an earth continuous wire complete all as specified and directed.
All as per item No 7 here-in-before but 4.00 Sqmm copper conductor for 5 Pin 15 Amp switch socket combintion on independent board and 4.00 Sqmm stranded copper conductor as an earth continuous wire complete all as specified and directed.
M&L for concealed point wiring complete with 1.5 Sqmm FRLS PVC insulated and unsheathed single core multistranded copper conductor cable for working voltage 1100 volts, grade drawn into and including 20 mm dia PVC conduit of medium grade for one light /fan point controlled by one switch including 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor and connecting to earth dolly & to be terminated in & inclusive of MS sunken box 1.2 mm thick (flush metal box) for mounting of fittings like switch, socket, fan regulator etc complete with 3mm thick laminated switch board cover all as specified and as directed.
All as per item No 10 above but for One bell point controlled by one bell push complete all as specified by the Engineer-in-Charge.
All as per item No 10 above but for One ceiling fan point controlled by one switch complete all as specified by the Engineer-in-Charge.
All as per item No 10 above but for One exhust fan point controlled by one switch complete all as specified by the Engineer-in-Charge.
All as per item No 10 above but for one light point controlled by two way switch complete all as specified by the Engineer-in-Charge.
All as per item No 10 above but for One 3 Pin, 5/6 amps socket outlet point ,on the same board with with 1.5 Sqmm cable size etc complete all as specified and as directed. .
All as per item No 10 above but for One 3 Pin, 5/6 amps socket outlet point , independent board with 1.5 Sqmm cable size etc complete all as specified and as directed. .
All as per item No 16 here in before but 2.5 Sqmm copper conductor for 5 Pin 15 Amp switch socket combintion on independent board and 2.5 Sqmm stranded copper conductor as an earth continuous wire complete all as specified and directed.
All as per item No 16 here in before but 4.00 Sqmm copper conductor for 5 Pin 15 Amp switch socket combintion on independent board and 4.00 Sqmm stranded copper conductor as an earth continuous wire complete all as specified and directed.
Taking down old/unservicable push bell & S&F bell push flush type 5 Amp complete all as specified and directed
Taking down old/unservicable switch any type and S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Taking down old/unservicable switch any type and S&F switch piano flush type 15 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Taking down old/unservicable switch any type and S&F switch piano flush type 15 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
Taking down old/unservicable switch any type and S&F 5 pin socket outlet, 5/6 Amps / 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed
Taking down old/unservicable switch any type and S&F 5 pin socket outlet, 2 in 1 3 Pin, 5 and 15 Amps, flush type, ISI marked, complete all as specified and directed
Taking down old/unservicable ceiling rose any type and S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65 x 20mm, 3 terminals, complete all as specified & directed.
Taking down old/unservicable fan regulator any type and S&F for fan regulator piano type suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
Taking down old/unservicable Bell any type and S&F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc, complete all as specified & directed.
M&L for main wiring with approved colour as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 10 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 10 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Four runs (with Red, Yellow, Blue colour for Phase + Black colour for Nutral) of 10 Sqmm cable, one run (with Green colour for Earth) of 10 Sqmm cable and one run of PVC conduit will be measured as one unit.
M&L for main wiring with approved colour as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 10 Sqmm nominal area and drawing into suitable size of PVC casing caping of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including in wall etc, one run of PVCinsulated with 10 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Four runs (with Red, Yellow, Blue colour for Phase + Black colour for Nutral) of 10 Sqmm cable, one run (with Green colour for Earth) of 10 Sqmm cable and one run of PVC casing caping will be measured as one unit.
M&L for main wiring with approved colour as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 06 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 06 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Four runs (with Red, Yellow, Blue colour for Phase + Black colour for Nutral) of 06 Sqmm cable, one run (with Green colour for Earth) of 06 Sqmm cable and one run of PVC conduit will be measured as one unit.
M&L for main wiring with approved colour as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 06 Sqmm nominal area and drawing into suitable size of PVC heavy duty PVC casing caping of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including in wall etc, one run of PVC insulated with 06 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Four runs (with Red, Yellow, Blue colour for Phase + Black colour for Nutral) of 06 Sqmm cable, one run ( with Green colour for Earth) of 06 Sqmm cable and one run of PVC casing caping will be measured as one unit.
M&L for main wiring with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run (with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit.
M&L for main wiring with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 2.5 Sqmm cable, one run (with Green colour for Earth) of 2.5 Sqmm cable and one run of PVC conduit will be measured as one unit.
Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB TPN 4 Way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system suitable for FP MCCB 'G' Frame including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB TPN 4 Way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB SPN 8 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB SPN 4 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB AC Box any type and S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20A, 10 KA 240 volt complete all as specified and as directed.
Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB SPN 2 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCCB any type and S&F MCCB triple Pole and neutral rated capacity 160 Amps, 415 Volts, breaking capcity 25 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S & F MCB triple Pole and neutral rated capacity 100 Amps, 415 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S&F MCB triple Pole rated capacity 63 Amps, 415 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S&F MCB single Pole & Neutral of capacity 32 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S&F MCB single Pole & Neutral of capacity 40 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S&F MCB single Pole rated capacity 5 to 32 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
M&L for taking down & refixing the ceiling fan/exhaust fan with replacement of unserviceable 3 core PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc complete all as specified and directed.
Taking down old/unservicable ceiling fan any type and and deposited in KV School store and S&F ceiling fan, 230 volts, 1200 mm sweep with service value of the fan shall be greated than 6.1 as per BIS with necessary aceessories and electrical connections for ceiling rose to fan terminal complete all as specified and directed.
Taking down old/unservicable exhaust fan any type and and deposited in KV School store and S&F for energy efficient exhaust fan of 300 mm sweep made of metal body ventil Air - DS type complete with louver with bolts nuts and washers size lt 15 cm 12 mm dia embedded in the wall including provision of PVC flexible coppler cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connecttion and making suitable size of hole to existing brick wall for fan base complete all as specified and directed.
Taking down old/unservicable light fitting any type and S&F new 1 x 10 W LED light fittings wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and integrated electric driver including 1 x 10W LED Tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make : Bajaj/Philips/Havells/Halonix
Taking down old/unservicable light fitting any type and S&F new 2 x 34 W LED light fittings four fit size, suspended- surface inner roof ceiling mounted hanging with regid conduit as per site requirement of class room and pure line extruded aluminium suspended diffused office llighting solutions with up-down light distribution available in standalone and continuous mounting versions in 4 fit etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make - Havells/Halonix/Bajaj/Philips cat part No-SP680P X 2 LED34S 6500 PSU WH L120S1.
Taking down old/unservicable light fitting any type and S&F new 1x 20W LED light fittings wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and integrated electric driver including 1 x 20 Watt LED Tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make : Bajaj/Philips/Havells/Halonix
S&F for round shape 15 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complet with with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
S&F for LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220V surface type with high efficieny PMMA diffuser soft glare free light complete with drovers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
Taking down old un-serviceable bldg security light fitting any type & Supply and fixing 1 x 35 Watt LED security light fitting suitable for external lights, comprising of pressure die cast aluminium housing heat resistant glass IP65/66 protection, better optics for uniform distribution including bracket made of 40 mm dia GI tubing medium grade of suitable size including fixing clamps & light fitting etc complete all as specified and directed. Make : Bajaj/Philips/Havells/Halonix
M&L for excavation in trenches for laying of cables, poles and stay in any type of soil n.exc 1.5 mtr wide and n.exc 1.50 mtr deep and getting out in any type of soil complete all as specified and directed.
M&L for returnning & filling in, including spreading and leveling, watering and well ramming in layers n.exc 25 cm all as specified ad dirtected.
M&L for removing excavated materials n.exc 50 mtr and depositing where complete all as specified ad dirtected.
M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : maesurement shall be done after puning down of sand.
M&L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
S&F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size. Note : Rate is inclusive of cable gland & cable lugs :-
2 core x 10 sq mm
4 core x 10 sq mm
4 core x 35 sq mm
4 core x 70 sq mm
3.5 core x 150 sq mm
3.5 core x 240 sq mm
M&L for boring hole under the road/path/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directe buy Engr-in-Charge at site. Note :- The cost of HDPE pipe shall be deemed to be included in quoted rate.
S&F for GI Pipe light grade for cable protection passing under road/floor or for fixing to poles all as complete all as specified and directed the following :-
80mm dia
50mm dia
Supply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 750 Amps rating fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1:3:6) type C2 as in foundation all as directed, comprising of the following :-
(a) INCOMING
(i) Thermal magnetic and microprocessor release MCCB 500 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos
(iv) Indicator Lamp - R - Y - B (Set of three).
(v) Frequency meter 40-55 Hz - 01 Nos
(b) OUTGOING
(i) Thermal magnetic MCCB 200 Amps, 4 Pole, 415V, 26 KA. Qty- 03 Ns
(ii) Thermal magnetic MCCB 100 Amps, 4 Pole, 415V, 16 KA. Qty- 01 Ns
(iii) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 01 Nos
(iv) Thermal magnetic MCCB 32 Amps, 4 Pole, 415V, 16 KA. Qty - 01 Nos
(v) Thermal magnetic MCB 32 Amps, 2 Pole. Qty - 01 Nos
(c) Digital time switch including 3 phase power contactor 40 Amps Make : Legrand Cat No 412641 & 3 phase contactor 40 A, Code No 412549, Havells, L&T or equivalent. Qty - 01 Nos.
Supply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, Copper bus bar 100 Amps rating fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1:3:6) type C2 as in foundation all as directed, comprising of the following :-
(a) INCOMING
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 38 KA - 01 No
(iv) Indicator Lamp - R - Y - B (Set of three).
(v) Frequency meter 40-55 Hz - 01 Nos
(b) OUTGOING
(i) Thermal magnetic MCCB 32 Amps, 4 Pole, 415V, 16 KA Qty - 02 Nos
(ii) Thermal magnetic MCCB 16 Amps,FP Qty - 01 Nos
(ii) Thermal magnetic MCB 32 Amps, DP Qty - 01 Nos
(c) Digital time switch including 3 phase power contactor 40 Amps Make : Legrand Cat No 412641 & 3 phase contactor 40 A, Code No 412549, Havells, L&T or equivalent. Qty - 01 Nos.
S&F junction box for street lights of size 155 x 210 x 92 mm 2 mm thick totally enclosed, with rubber gasket, water tight juction box IP 66 protection single leaf shutter in front having proper locking arrangements and stud terminal (provision for socket bolting) - 05 Nos suitable for 240 voldts, 50 Hz, 2 wire internal wiring system including MCB SP 6 Amps - 01 Nos and mounted on security light pole with suitable bracket nuts, bolts complete all as specified and directed. Make- Bentex, Hensel.
Taking down old unserviceable street light fittings any type & sizes and supply and fixing Smart Bright street LED light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, pole dia 48/60mm with pre wired and necessary mounting arrangements including provision of 4 sq mm three core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium grade of suitable dia braket 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 2 sets, bolts & nuts washers etc complete all as specified and directed. Make : Philips cat part No BRP062 LED 65 CW SLA S1 PSU, Havells, Bajaj, Orient
Taking down old unserviceable street light fittings any type & sizes and supply and fixing Smart Bright street LED light fitting 84 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, pole dia 48/60mm with pre wired and necessary mounting arrangements including provision of 4 sq mm three core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium grade of suitable dia braket 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 2 sets, bolts & nuts washers etc complete all as specified and directed. Make : Philips cat part No BRP062 LED 84 CW SLA S1 PSU, Havells, Bajaj, Orient
Taking down old un-serviceable Post Top lantren fitting of any type & size and S&F for Post Top lantren LED fitting Alumininum sheet spun canopy, Thick Imported Acrylic sheet molded body finished with polyurethane paint (With prior Treatments) suitable for 5 to 12 Watt LED bulb B 22 ABS Holder Cast aluminum Spigot pole entry : 78 mm complete with IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fittingcomplete all as specified and directed by Engr-in-Charge. Make : Mepro electricals cat part No PTL - 15 ref or equeivalent to Havells/Bajaj/Philips/Orient
Taking down old un-serviceable flood light fitting of any type & size and S & F for Smart Bright essential flood LED light fitting of capacity 100 watts with IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fittingcomplete all as specified and directed by Engr-in-Charge. Make : Philips cat part No BVP142 P LED 100 CW FG GR PSU or equeivalent to Havells/Bajaj
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia medium grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal (for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia medium grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles). Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above grnd 7.5RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters as directed. Note : Size of lettering and colours of paints will be directed by Engr-in-Charge.
M&L for painting carefully (by taking necessary shut down from respective sub-station) on PPC poles 9 m high from (above grnd 7.5RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters as directed. Note : Size of lettering and colours of paints will be directed by Engr-in-Charge.
Taking down old un-serviceable PVC cable any type & sizes and supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of pvc tape and overall pvc sheathed in service connections suspended buy insulating one twin cored 6 sqmm cable cicular complete all as specified and directed.
Schedule of credit amount of Rs. 64,127.00 to be deducted during AOC
Goodluck Enterprises
ELCON
TRISHLA CONSTRUCTIONS
M/S BHATIA CONSTRUCTIONS
RAVI ENTERPRISES
RAINA SALES AND SERVICES
kiran electrical and hardware centre
SR ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .