Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 86 INDUSTRIAL AREA PHASE 1 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹5.0 L+₹8,200 (1.65%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹6.2 L+₹1.3 L (26.0%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID |
Tender Value
₹6.5 L
Closing Date
20 Aug 2022, 2:00 pmClosed
CWE (AF) JAMMU
CWE (AF) JAMMU
Soil Investigation for external services for Akash Missile system at AF Stn Pathankot
2022_MES_544697_1
30018/JO/11/E3
Limited
Miscellaneous Works
Works
30 days
CWE (AF) JAMMU
Please refer tender documents
3 documents required · 3 mandatory
₹0
Exempted
12 Oct 2022
11 Aug 2022
22 Aug 2022
11 Aug 2022
20 Aug 2022
12 Aug 2022
1. Determining SBC of soil by performing standard penetration test as per IS 2131 by boring 100mm dia bore hole up to 6 meter depth from NGL or refusal along with SPT at every change in stratum or at intervals of not more than 1.50 mtr depth whichever is earlier all as per IS 2131-1981(reaffired 1997). In case of gravely or boulder strata an open pit upto 3.00mtr depth alongwith dynamic cone penetration test as per IS-4968 upton 6 mtr or upto refusal whichever is earlier, collection of soil samples (disturbed or undisturbed), computation of bearing capacity complete with lab analysis as per relevant IS Codes such as :- (a) Atterberg's limits (IS 2720 part-5) (b) Wet and dry density. (c) Soil particle size distribution using sieve analysis/Hydrometer analysis. (d) Tri-axial shear test C-determination. (e) Shrinkage test. (f) Consolidation test. (g) Specific Gravity test. (h) Crushing strength of Rocks sample. (j) Permeability test. (k) Chemical analysis of ground water sample (Min 2 sample). (l) Free soil index. (m) Chemical analysis of soil. (n) Natural Moisture content.
2. Determining SBC of soil by performing standard penetration test as per IS 2131 by boring 100mm dia bore hole up to 10 mtr depth from NGL or refusal along with SPT at every change in stratum or at intervals of not more than 1.50 mtr depth whichever is earlier all as per IS 2131-1981(reaffired 1997). In case of gravely or boulder strata an open pit upto 3.00mtr depth alongwith dynamic cone penetration test as per IS-4968 upton 10 mtr or upto refusal whichever is earlier, collection of soil samples (disturbed or undisturbed), computation of bearing capacity complete with lab analysis as per relevant IS Codes such as :- (a) Atterberg's limits (IS 2720 part-5) (b) Wet and dry density. (c) Soil particle size distribution using sieve analysis/Hydrometer analysis. (d) Tri-axial shear test C-determination. (e) Shrinkage test. (f) Consolidation test. (g) Specific Gravity test. (h) Crushing strength of Rocks sample. (j) Permeability test. (k) Chemical analysis of ground water sample (Min 2 sample). (l) Free soil index. (m) Chemical analysis of soil. (n) Natural Moisture content.
3. Determination of CBR value of soil for laboratory test to evaluate the subgrade strength of road and pavement by collecting the sample from site as per IS 2720 Part 16-1987, complete all as specified.
4. Determination of CBR value of soil for field test to measures the relative strength of existing road use in pavement design as per IS 2720 Part 31 -1987 , complete all as specified.
5. Determination of modulus of subgrade reaction (K- value) of soil to evaluates the stiffness of sub base of soils as per IS 9214- 1979, complete all as specified. Note :- (i) Furnishing SBC report in pentuplicate including recording SBC for each location for the type of foundation and maintaining photographic record (Min three photographs per hole duly annoted as approved by Engr-in-Charge). (ii) Rate including all items of works necessary for carrying out complete soil exploration work collection of sample testing at laboratory and filed test result and submission of reports (five sets) (iii) Rate includes for submission of detailed recommendation for shallow foundation and bearing capacity of soil (SBC) at 1.5/2.0/3.0 m depth. Type of foundation and depths of footing be clearly specified. (iv) In case, very weak soil strata is encountered, recommendation about pile foundation i.e Type, Dia, depth of pile, safe load carrying capacity and socketing of pile into hard rock shall be clearly given in the report. Also measures for found improvement if required be included in the report . Safe bearing capacity shall be worked out based on N valve shear failure and settlement criteria. (v) Rate includes for submission of 3 copies of test report. (vi) RL of ground level/foundation level with respect to BM should be invariable mentioned in the soil investigation report. (vii) Recommendation as regards possibility of liquetaction of soil in case of saturated or partially saturated loose/ un-compacted sand soils. (viii) All work to be carried out in presence of executive i.e AGE/GE of GE (AF) Pathankot and videography of same is to be made part of Report.
SUVIDHI TESTING ENGINEERS
National Soil Testing and Research Laboratories
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_608885.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .