| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹10.5 L+₹73,936 (7.58%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹10.5 L+₹74,073 (7.59%)Rejected-Finance JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹28,620
Closing Date
3 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
AUGMENTATION OF ELECTRIC SUPPLY TO ECHS POLYCLINIC TYPE D MH UNDER GE SOUTH PATHANKOT
2022_MES_521897_1
GES/PKT/T-05/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹28,620
Yes
12 Aug 2022
5 May 2022
6 Jun 2022
5 May 2022
3 Jun 2022
20 May 2022
60 days
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings/ plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection .
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5 core PVC sheathed, armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required.
25 Sqmm 4 core
3.5 core 35 Sqmm
3.5 core 50 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
3.5 core 120 Sqmm
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate notless'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in lectrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
All as per Srl Item No.16 above but using galvanised iron strip 25×4mm as earthing lead
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed. Note: a) The M/L for Items like lamp, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .
Supply only the following spares suitable for LED street/ Flood light fittings of
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
S&F for off load Changeover switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps, 36 KA alongwith 40x40x6mm angle iron stand, including indication lamp for source 1 & 2 ,floor mounted grouted in PCC 1:2:4 etc complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light/ Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed Note: In ceiling Portion surface conduit wiring shall be carried out.
All as per srl item 36 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per srl item 36 above but for one module socket out let 5/6 Amps on Independent board.
All as per srl item 36 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked , complete all as specified and directed.
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked , complete all as specified and directed.
M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked, complete all as specified and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed.
M & L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed.
S&F for Buzzer Ding Dong, AC 230 volt single pole, complete all as specified and directed.
M&L for ceiling rose 2-3 terminal size 65x20mm, complete all as specified and directed.
S&F polycarbonate lamp holder Angle type insulated body with back plate for batten fitting, fixing, complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed. ( In ceiling Portion surface conduit wiring shall be carried out.).
All as per srl item 49 above but for one 3 pin 5A socket outlet independent board.
All as per srl item 49 above but for one 5A socket outlet on the same board
All as per srl item 49 above but for one 5A socket outlet below the board.
All as per srl item 49 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts, all as specified and directed.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
Supply & Fix in replacement sheet metal enclosure with DB's ( grouted in walls) double door type for MCB's 08 ways with 200 Amps 240 volts rated bus bar all as specified.
S & F in replacement existing unsv distribution board iron clad, double door with IP-43 1K-08 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
M&L 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' sereis complete all as specified.
S&F MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' sereis complete all as specified all as directed
Supply and Fix in replacement inverter type LED fitting 1x20W LED including LED tube 4 feet long having bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and Fix in replacement existing UNSV decorative box type fitting 4 feet long with LED tube light fitting 20 watt complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and fixing in replacement existing unsv integrated LED bulk head light fitting 1X10 watts IP-65 protection connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
Supply and fix bldg security light fittings with LED security light fittings 25 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed.
Supply and Fix in replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F inverter type LED Lamp 9 watt 230 volts complete all as specififed and directed.
S&F LED Lamp 12 watt 230 volts complete all as specififed and direccted.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM, with service value 6.00 BEE. Five star, rated with brushless direct current motor, (BLDC)complete including connecting to ceiling rose all as required or directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.
Supply and fix water heater storage vertical type, SS tank, polycarbonate body electrical operated, capacity 25 litres. BEE 5 star rated duly fixed on wall through proper anchoring, grouting with the help of suitable nuts and bolts, and making good all the disturbed surface, complete all as specifed and directed.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 4 sqmm multistrand in concealed conduit with 4 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 6 sqmm multistrand in concealed conduit with 6 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SATPAL AND BROTHERS
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .