| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.1 L+₹1.4 L (6.32%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.8 L+₹3.1 L (14.1%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹26.9 L+₹5.1 L (23.7%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in category b(i) |
Tender Value
₹32.4 L
EMD Value
₹65,000
Closing Date
7 Dec 2022, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Spl repair to (JCO MD ACCN) including roof treatment and certain minor works at 39 GTC Varanasi Under GE (East) Allahabad.
2022_MES_558314_2
8606/E8
Open Tender
Civil Works
Item Rate
180 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹65,000
Yes
27 Jan 2023
9 Nov 2022
9 Dec 2022
9 Nov 2022
7 Dec 2022
23 Nov 2022
9 Nov 2022 - 16 Nov 2022
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, including cutting of reinforcement as required to facilitate demolition, complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
Plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate), 25mm thick, as in levelling course, benching, etc, finished even and rough to receive cement mortar screed bed, complete all as specified and directed.
Plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate), 75mm thick, as in levelling course, benching, etc, finished even and rough to receive cement mortar screed bed, complete all as specified and directed.
Chequered cement concrete tiles 250mm x 250mm x 20-25mm thick, with grey cement and no pigment; set, jointed and pointed in neat cement slurry in floors, laid as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including provision of 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed.
Plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finished even and smooth without using extra cement, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding including backing, removing serviceable tiles to store, removing rubbish off the premises, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, area of each tile exc. 0.18 Sqm but n. exc. 0.38 Sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, area of each tile exc. 0.11 Sqm but n. exc. 0.18 Sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Non - skid Ceramic, coloured tiles 7 to 8 mm thick, area of each tile exc. 0.11 Sqm but n. exc. 0.18 Sqm, as in vertical surfaces such as skirting / dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 10 mm thick backing coat in CM 1:4, complete all as specified and directed.
Glazed ceramic coloured tiles as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 450mm x 300mm x 7-8 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing coat of tiles in cement mortar 1:4, complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and directed.
Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 10mm thick screed in CM 1:4 complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed.
Brickwork with flyash bricks, old size straight or curved on plan to any radius in half brick walls, built in CM 1:4, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site, complete all as specified and directed.
Rendering 15mm thick, on other than faces of brick work or concrete surfaces in cement mortar 1:6, finished surface even and fair, complete all as specified and directed.
Rendering 10mm thick, on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished surface even and fair, complete all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces of ceilings, finishing the surface even and smooth, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion paint of approved colour over a coat of primer over 1mm thick wall care putty finish, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved colour over a coat of primer over 1mm thick wall care putty finish, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces with wall care putty and applying uniform layer of 1mm thick wall care putty including preparation of surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of acrylic emulsion paint on walls surface over a coat of primer, complete all as specified and directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces with wall care putty and applying uniform layer of 1mm thick wall care putty including preparation of surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of cement base paint on walls surface, complete all as specified and directed.
Complete removal of existing treatment from ceilings (any number of layers) by scrapping with steel scrappers or any other means and preparation of surfaces by rubbing with sand or emery paper and applying two coats of white wash, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded in any mortar, complete all as specified and directed.
Green marble work (table rubbed and polished), 15-20mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like, laid over and including provision of 15mm thick screed bed in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match, complete all as specified and as directed.
Taking up or down galvanised steel tubing 15mm bore and connections, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 15mm dia, complete all as specified and directed.
Taking up or down galvanised steel tubing 20mm bore and connections, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 20mm dia, complete all as specified and directed.
Taking up or down galvanised steel tubing 25mm bore and connections, complete all as specified and directed.
Galvanised Steel water tubes medium grade in any size or length galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 25mm dia, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore, fixed in repair, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked, 500 litre capacity, hoisted and fixed in position including necessary fittings such as connection pieces with PVC nipple for inlet / outlet & wash out pipes, including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density PVC float valve 20 mm dia screwed for iron pipe complete as specified in SSR Part-I, fixed in repair, complete as specified & directed.
GI nipple suitable for HDPE water tank, 20mm bore, (Minimum weight 45gms ), fixed in repair, complete all as specified and directed.
PVC low level cistern, 10 litre capacity, white’ with inlet, float valve including bracket with 32mm dia PVC pipe 600 mm long, fixed in repair, complete all as specified and directed.
Water closet squatting pan 'Orissa Pattern' of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) with P' or 'S' trap complete incl connection to trap and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, fixed in repair, complete all as specified and directed.
Vitreous china wash hand basin white flat back of size 550mm x 400mm excluding chain, plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets, fixed in repair, complete all as specified and directed.
Soap dish brass, chromium plated, fixed in repair, complete all as specified and directed.
Chromium plated brass shower rose 125 mm size, fancy type with swivel joints fixed to 15mm bore pipe, fixed in repair, complete all as specified and directed.
Tubular towel rail brass chromium plated, 20mm dia, 'D' type, 600mm long, fixed with two plugs of second class hardwood embedded in CM 1:3., complete all as specified and directed.
PVC connection 15mm size with PTMT nuts on both ends of length 450mm, fixed in repair, complete all as specified and directed..
Bib taps, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for 15mm bore, fixed in repair, complete all as specified and directed.
Preparation of new wooden surfaces exc 10 cm width or girth with sand or emery paper & applying two coats of synthetic enamel paint over a coat of pink primer , complete all as specified and directed.
Preparation of old wooden surfaces and applying one coat of synthetic enamel paint on old wooden surfaces of any description, over 10 cm width or girth, complete all as specified and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of old steel and iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
RCC 1:2:4, type B-1, using 20mm graded stone aggregate in Chajjas, complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for flat rough finished surface of concrete, complete all as specified and directed.
TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed.
Angle valve, cast copper alloy chromium plated with long shank and cup, screwed down, high pressure, with crutch or butterfly handle, fancy type, 15mm bore, screwed for iron pipe or for unions, fixed in repair, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, chromium plated with long shank and cup (concealed type), 15 mm bore, fixed in repair, complete all as specified and directed.
Grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms), fixed in repair, complete all as specified and directed.
Stainless steel tubing of 25mm dia with PVC coating for curtain rod fancy type including fancy type PVC rings and CP brackets, socket and knobs (wall to wall or flush to wall) for securing to curtain rod, fixed in repair, complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutters from the frame) area exceeding 1.5 sq.m but not exceeding 4.0 sq.m each , complete all as specified and directed..
Taking down chowkats or frames area not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down shutter of any description area exceeding 1 sq.m but not exceeding 2sq.m each, complete all as specified and directed..
Factory made 35 mm thick, second class hardwood plain framed, panelled shutter (two panel) with panels of timber flat on both sides feather edged, or of 12 mm veneered particle board, medium density or particle board with commercial face, complete all as specified and directed.
Glazed and skeleton shutters, 35mm thick, second class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), divided into squares with plain, chamfered or rounded mitered beads for securing glass/gauge complete all as specified in SSR Pt- I, section 8, clause 8.24(a) and as directed. Note: Glass or wire cloth, etc. in panels or sash squares shall be measured separately.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified and directed.
Solid PVC double door Frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and directed.
All as per item No.66 above but wire gauzed shutter 30mm thick using wood grain printed PVC sheet to be used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90° ) used instead of exposed portion of PVC sheet beading. The panel shall be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed.
Factory Made Solid PVC Moulded Door Shutter with particle board core 28 to 30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, with Particle board core, supplying & fixing in the frame at site as per specification & sketch shown in section 8 of SSR part II, complete all as specified and directed.
Door closer hydraulically regulated, Aluminium die cast, designation No. 3, universal type, suitable for aluminium door shutters and of weight between 61 to 80 kg and fixed, fixed in repair, complete all as specified and directed.
Rolled mild steel conforming to Fe 410-W (Gde-E- 250) quality-A, sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc, complete all as specified and directed.
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded joint, complete all as specified and directed..
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete without glazing bars, dovetailed or welded joint, complete all as specified and directed..
Framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, and similar work conforming to Fe-290 Gde-E-165, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm crushed stone aggregate) as in fixing of hold fasts with and including provision of necessary form work if required complete all as specified and directed..
Aluminium anodised, barrel tower bolts of 200 mm length, extruded section, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
Butt hinges, 100 mm long, medium weight, cold rolled mild steel, complete all as specified and directed.
Aluminium handles, 150mm size, cast type, anodised, complete all as specifeid and directed.
Aluminium handles, 100mm size, cast type, anodised, complete all as specifeid and directed.
Aluminium anodised hasp and staple, 150mm size, safety type with mild steel hinge pin including bolt to hinge plate, fixed with screws, fixed in repair, complete all as specified and directed.
Second class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including butt hinge etc & all necessary labours; articles n exc 200 cu. cm each, complete all as specified and direcetd.
Supply only Butt hinges, 50 mm long, medium weight, cold rolled mild steel, complete all as specified and directed..
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, in repair, complete all as specifed and direcetd.
Prelaminated particle board, 18/19 mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, fixed in repair, complete all as specified and directed.
Powder coated aluminium two track sliding window / CSW / Ventilator with powder coated aluminium anodized frame of aluminium section 61.85 x 31.75 x 1.2 mm thick with shutters having styles & rails of powder coated aluminium section 44.45 x 44.45 x 1.2mm thick including jointing cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as hinges, tower bolts, handles etc including 5.5mm thick ordinary plain glass complete including providing and fixing aluminium chequered grill of anodized section of mesh 50 x 50mm of 08 mm dia of aluminium bar fixed to frame with 20 x 2mm aluminium flat with screw and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified & directed.
Solar/ sun control film having 25 micron reflective type sticked to glass panes of aluminium doors or windows as required as per instruction of manufacturer complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in floors or trenches, complete all as specified and directed..
PVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in floors or trenches, complete all as specified and directed..
PVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.. Note : Stack clamps for fixing in walls shall be included in the quoted rates.
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.. Note : Stack clamps for fixing in walls shall be included in the quoted rates.
PVC (SWR) bends of any radius and 75mm bore, jointed with adhesive, complete all as specified and directed..
PVC (SWR) bends of any radius and 110mm bore, jointed with adhesive, complete all as specified and directed..
PVC (SWR) junction single, (Single T) equal or unequal, 75 mm bore, jointed with adhesive, complete all as specified and directed..
PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore, jointed with adhesive, complete all as specified and directed..
PVC (SWR) vent cowl, 75mm size, complete all as specified and directed..
PVC (SWR) vent cowl, 110mm size, complete all as specified and directed..
PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed in repair, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
Supply, laying, jointing and testing of Salt-glazed stoneware drain pipes of grade 'A', internal diameter 150 mm, laid in trenches and jointed with bends and taper bends, any radius complete with collars CM 1:1, complete all as specified and directed. NOTE:- The measurements shall be net as fixed between the fittings without any allowances for cutting and waste. Quoted rate shall deemed to include all necessary extra joints, waste and cutting.
Cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm crushed stone aggregate for the 150 mm internal dia of pipe complete all as specified & directed.
Kitchen sink with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm, fixed in repair, complete all as specified and directed.
Stainless steel plate rack / utensils rack of size 600mm x 750mm x 250mm depth made out ot 0.63mm thick stainlesss steel sheet, fixed to wall with brass screws including provision of necessary fittings / fixtures viz., nuts, bolts and washers of suitable size, fixed in repair, complete all as specified and directed.
Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms), fixed in repair, complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly-nuts, screwed for iron pipe 15mm bore, fancy type, fixed in repairs, complete all as specified and directed.
PCC 1:3:6 type C-1 using 20mm crushed stone aggregate as in surface channels and drains including necessary form work if required complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
Plain Cement concrete 1:2:4, type B-0 (12.5 mm crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges using water proofing compound, complete all as specified and directed. NOTE:- Water proofing compound shall be paid separately under respective item of this Schedule.
Material and labour for preparation of sunken portion using glass fibre reinforced acrylic modified cementitious coating system in following stages :- (i) Cleaning of RCC surface to remove dust, loose particles and grinding any sharp edges including sealing of pipe penetration in toilets core cutting including Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a groove thickness of minimum 20 mm on pipe penetration joint to concrete. (ii) Preparation of surface of sunken portion and applying glass fibre reinforced acrylic modified cementitious coating as top coat @ 1.5 kg/m2 over reinforcement over base etc. (iii) Application of a protection plaster (12-15mm) mixed with water proofing compound @ 0.10 kg per bag of cement. The product should conform to IS-2645, complete all as specified and directed.
Plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate), as in mass concrete in foundation filling, sunken floor paving, complete all as specified and directed.
Taking down existing water proofing treatment any thickness & removing the debris from the premises to a distance exc 250m from the MOD land including cleaning/washing down and keeping surfaces clean complete all as specified and as directed.
Providing water proofing treatment over cleaned roof surface with APP modified bitumenous membrane weight not less than 3 kg per sq.m comprising of the following and testing of following: (a) 10 mm thick rendering or screed bed or bedding layer in cement sand mortar 1:4 mixed with water proofing compound @ 3% by weight of cement, finished surface even and smooth without using extra cement. (b) One coat of Bitumen primer confirming to IS-3384-1965 @ 0.3 lit per sqm. (c) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS-702-1998 for water proofing membrane. (d) Providing APP modified polymeric water proofing membrane having weight not less than 3 kg per sq.m with 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length. (e) Again Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS-702-1998 for water proofing membrane. (f) Spreading of coarse sand over entire bitumen surface and topping with 40mm thick brick tiles laid over and including provision of 15 mm thick screed bed in CM 1:6 and joints shall be pointed with CM 1:3, complete all as specified and directed. Note: Water proofing compound to be measured and paid separately.
Supply only integral water proofing compound, complete all as specified and directed.
Taking down carefully point wiring of any type and any description / caping or concealed [light point, fan point or socket point] including removal of battens, pipes, plug sockets, switches, shades, ceiling roses, light fittings etc complete and making good disturbed surface to match the exisitng, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
(a) One light / fan / bell / exhaust fan point, controlled by one one-way 5Amp switch
(b) One 3 pin, 5 Amp socket outlet point on an independent board.
(c) One 3 pin, 5 Amp socket outlet on the same board with other switches
(d) One light point controlled by two two-way switch
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 2.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/ fan/ bell/ buzzer/ exhaust fan point controlled by one, one way 5 Amp switch including provision of concealed opressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 2.5 sq.mm FR type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Switch piano, flush type single pole, one way 5/6 Amp 230 volts all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp 230 volts all as specified and directed.
Switch piano, flush type single pole, two way 5/6 Amp 230 volts all as specified and directed.
Switches, bell push, flush type, 5 amp, complete all as specified and directed.
Socket outlet, 2 in 1, 5 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Electric bell ding dong type AC 230 Volt 50 hz single pole, complete all as specified and directed.
Lamp holder, PVC/polycarbonate body with back plate/ cord grip cap suitable for batten/ angle/ pendent fittings, complete all as specified and directed.
LED retrofit lamp of capacity 12/15 Watt, B-22 holder base with polycarbonate body and aluminium heat sink warm white complete including taking down old / unserviceable CFL / bulb, complete all as specified and directed.
Switch socket combination 2 in 1, 6 pin, 16 Amp flush type universal, 240 Volts, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
Sheet metal enclosure for MCB Distribution Board SPN, 8 way, double door, vertical type, 240 V with 200 Amps rated bus bar, complete with incoming / outgoing connection through proper size of lugs and cable glands including taking down existing DBs (including MCBs), complete all as specified and directed.
MCB SP 6 to 32 Amp, 240 Volt, conforming to 'C' curve, 10kA breaking capacity, complete all as specified and directed.
MCB SPN 40 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed.
Sheet metal enclosure for MCB/MCCBs/VTPN Distribution Board, double door, 415 V with 200 Amps rated bus bar, complete with incomer and outgoing connection through proper size of lugs and cable glands including taking down existing DBs (with MCB/MCCBs), complete all as specified and directed. Note: MCB & MCCB to be measured and paid separately under respective items.
MCCB 63 Amp, 4 pole, 415 Volt, conforming to 'B' curve, 16kA breaking capacity, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
Excavation in trenches not exceeding 1.5m deep and not exceeding 1.5m wide or area not exceeding 10 sq.m on plan and depth not exceeding 1.5 m for foundation, for shafts, wells, cesspits, manholes, pier holes etc., and getting out in any type of soil, complete all as specified and directed.
Removing of surplus excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 25 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
GI pipes, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls / ceilings or laid in floors / laid in ducts / laid under road crossing for cables, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 50mm bore of pipe, fixed in repair, complete all as specified and directed. NOTE:- Necessary excavation and earthwork for GI pipe shall be measured and paid separately under respective items of this Schedule.
Spreading of natural, clean and dry river sand in trenches for cable cushioning, including punning the sand upto desired thicknes and consolidated, complete all as specified and directed. NOTE: Punned thickness shall only be measured and paid.
Supply and lay burnt clay fly ash bricks class 'B', laid in trenches for cable protection with length of brick equal to width of trench, complete all as specified and directed.
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Ceiling fan regulator flush type, electronic, rotary stepped type, AC 230 V, suitable for any type of ceiling fan, complete all as specified and directed.
LED tube light fitting, 20/22 Watt, decorative type, slim aluminium square profile, high Lumen output, energy efficient, direct surface mounting including connecting up with twin core PVC insulated copper conductor of suitable size, including taking down the old unserviceable light fittings, complete all as specified and directed.
LED integral round shape, surface mounting high power LED luminaire, dome shaped opal diffuser lamp of capacity 18 Watt including taking down old unserviceable CFL/ bulb, complete, all as specified and directed.
Comet wall light unique aesthetic white colour modern wall light having suitable holder for B-22 bulb, including taking down unserviceable CFL/ bulb holder, complete all as specified and directed.
LED edgelite linear and compact 9W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser including connecting up with three core flexible copper conductor cable including taking down old unserviceable light / mirror fittings, complete all as specified and directed.
Drilling through bore hole by trenchless technology without disturbing the existing road, complete all as specified and directed.
Supplying, testing and installation of energy efficient five star rating storage water heater (geyser), 25 litre capacity, vertical type, 2 KW, ISI marked including fixing the geyser on wall with and including provision of nut bolts / anchoring bolts and making electric connection and making good disturbed surface of wall to match the existing, complete all as specified and directed.
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, 20 mm bore, complete all as specified and directed.
Hot water outlet PVC connection , heavy duty made of chromium plated nuts, bolts and flexible tubing 15mm dia, 450mm long, complete all as specified and directed.
Exhaust fans of metallic body heavy duty AC single phase 230 / 240 V, of size 300 mm sweep, 900 rpm, with bracket, louver, nuts and bolts including connection with 1.5sq.mm PVC copper flexible wire of appropriate length, complete all as specified and directed.
Building security / street LED light fitting 35 Watt IP-65 protection pressure diecast aluminium body, heat resistant glass, including driver and making necessary electric connection with 2.5 sqmm twin core copper wire 1.5m long and fixed on existing GI pipe, fixed to pole or on wall, complete all as specified and directed.
Hi wall split type air conditioner units indoor/ outdoor complete with cordless remote control unit and with in-built cooling arrangement, air ioniser and plasma filler for better indoor air quality, with digital inverter rotary type compressor, single phase units 220V- 240V, 50Hz, with 5 star rating and EER 3.2 of 1.5 TR capacity, complete all as speciifed and directed. Note: (i) Copper pipe of dia ½'' and ¼'' with insulation and drain pipe up to 10 RM as per rquirement will be concealed/casing caping as specified and directed by Enger-in-charge shall be deemed to be included in unit quoted rate. (ii) Wall dirll as per requirement to install AC indoor/outdoor unit and making good to walls disturbed surface & applying finished to match existing surface complete all as specified and directed shall be deemed to be included in unit quoted rate.
Voltage stabilizer for automatic operation, SP naturally are cooled in-door type designed for input variation 170 V to 250 V output stabilized at 230 V with accuracy of +/- 2.5% and capacity 5 kVA, complete all as specified and directed.
PVC AC modular surface box with combination 2 in1, 5 pin, 5/15 Amps with and including heavy duty socket and 1 X MCB SP 16 Amp, complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC rigid conduit 20mm dia and accessories connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly including taking down existing sub main wiring any type and making good disturbed surfaces to match with existing including sinking of boxes , complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 95 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
MCCB 100 Amp, 4 pole, 415 Volt, conforming to 'B' curve, 25kA breaking capacity, complete all as specified and directed.
MCB TPN 63 Amp, 415 volts 16kA, 'B series' complete all as specified and directed.
Ceiling light with recessed mounted LED light luminaries of size 600 mm x 600 mm an independent isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage- 36 watt maximum, Colour Temp - 3000 to 6500 K, Lumen output- 4200-4400 Lm, THD < 10%, PF > 0.95, having short circuit and surge protection upto 4 KVA with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076, complete all as specified and directed.
MCB SPN 63 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed.
PVC rectangular box of size 100mm x 100mm x 50mm for mounting switches, sockets, fan regulators etc, with 3mm thick plastic laminated sheet cover, complete all as specifed and directed.
R.S Enterprises
M/S Akhilesh Enterprises
M/S SHIVA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .