Tender Value
₹65.8 L
EMD Value
₹1.3 L
Closing Date
17 Sept 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverof[V/N or 'V' whichever is less; where V = Advertised value of the tenderincrores of Rupees N= Number of years prescribed for completion ofworkfor which bids have been invited. The average annualcontractualturnover shall be calculated as an average of "totalcontractualpayments" in the previous three financial years, as per theauditedbalance sheet. However, in case balance sheet of the previousyear isyet to be prepared/ audited, the audited balance sheet of thefourthprevious year shall be considered for calculating averageannualcontractual turnover. The tenderers shall submit requisiteinformation asper Annexure-VIB, along with copies of Audited BalanceSheets dulycertified by the Chartered Accountant/ Certificate fromCharteredAccountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer musthavesuccessfully completed any of the following during last 07(seven)years,ending last day of month previous to the one in which tender isinvited:Three similar nature of works each costing not less than theamountequal to 30% of the advertised value of the tender, or Two similarnatureof works each costing not less than the amount equal to 40% oftheadvertised value of the tender, or One similar nature of workeachcosting not less than the amount equal to 60% of the advertisedvalue ofthe tender. (b) (i) In case of tenders for composite works (e.g.worksinvolving more than one distinct component, such as CivilEngineeringworks, S&T works, Electrical works, OHE works etc. And in thecase ofmajor bridges - substructure, superstructure etc.), the tenderermusthave successfully completed any of the following during last 07(seven)years, ending the last day of the month previous to the one inwhichtender is invited: Three similar nature of works each costing notlessthan the an amount equal to 30% of the advertised value ofeachcomponent of the tender, or Two similar nature of works eachcosting notless than the amount equal to 40% of the advertised value ofeachcomponent of tender, or One similar nature of work each costing notlessthan the amount equal to 60 % of the advertised value ofeachcomponent of the tender. Note for b(i): Separate completed worksofminimum required values for each component shall also beconsideredfor fulfillment of technical eligibility criteria. (b) (ii) In suchcases, whatconstitutes a component in a composite work shall be clearlypredefinedwith estimated tender cost of it, as part of the tenderdocuments withoutany ambiguity. (b) (iii) To evaluate the technicaleligibility of thetenderer, only components of work as stipulated intender documents forevaluation of technical eligibility shall beconsidered. The scope of workcovered in other remaining componentsshall be either executed by thetenderer himself if he has workexperience as mentioned in clause 7 (a)(ii) of Part-II of GCC or throughsubcontractor fulfilling the requirementsas per clause 7 of Part-II of GCCor jointly i.e., partly himself andremaining through subcontractor, withprior approval of Chief Engineerin writing. However, if required in tenderdocuments by way of SpecialConditions, a formal agreement dulynotarised, legally enforceable in thecourt of law, shall be executed by themain contractor with thesubcontractor for the component(s) of workproposed to be executed bythe subcontractor(s), and shall be submittedalong with the offer forconsidering subletting of that scope of worktowards fulfillment oftechnical eligibility. In case after the award of thecontract or during theexecution of work it becomes necessary for thecontractor to changesubcontractor, the same shall be done withsubcontractor(s) fulfilling therequirements as per clause 7 of Part-II ofGCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply,installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor licenseas perIndian Electricity Rules for the respective category ofworks issued byGovernment Electrical License Board on orbefore the closing date oftender. Copy of the electricalcontractor license should be submittedalong with the tenderoffer, otherwise, the tender will be summarilyrejected
51 conditions · 5 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
SCHEDULE A : Provision of Electrical work against 30 bedded capacity RPF barrack to be constructed at CPK station.(Electrical Portion) And SCHEDULE B : Construction of Camp Office for Wildlife Study Centre and monitoring of upcoming projects near Kaziranga National park in LMG division (Electrical portion)
EL-LM-26-27-16~NFR
EL-LM-26-27-16
Open
Works - General
180 Days
Hojai, Assam
₹0
₹1.3 L
22 Aug 2026
22 Aug 2026
3 Sept 2026
138 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 14,73,169.81 | ||
| — | 300.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 1,16,844 | |
| — | 50.00 | — | — | ||
| Supply of materials and wiring of fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 23,791.5 | |
| — | 80.00 | — | — | ||
| Supply of materials and wiring of 6 amps plug point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) and 2 modular 6 Amps 5 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 19,782.4 | |
| — | 3.00 | — | — | ||
| Supply and wiring of geyser point by good quality accessories with proper connection complete with 15 amps plug point and 16 amps DP MCB overload protection, through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire: All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 1,846.41 | |
| — | 100.00 | — | — | ||
| Supply, fitting fixing of 18/20 watt Led indoor light | — | — | — | 32,284 | |
| — | 10.00 | — | — | ||
| Supply of materials and wiring of Exhaust fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with fan marking) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(ie thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 5,158 | |
| — | 1.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of 8 way SPN (Single Pole& Neutral) distribution board, single door type, suitable for concealed wiring, complete with allnecessary accessories and internal connections. The DB shall be equipped with the followingprotective devices: (i) 16 Amp SP MCB, C Curve - 2 Nos., (ii) 10 Amp SP MCB, C Curve - 2 Nos., (iii) 6Amp SP MCB, C Curve - 2 Nos., and (iv) Over Voltage Release/MSU 275V AC - 1 No. The distributionboard shall be complete with suitable enclosure, neutral link, earth bar, bus bar, terminals, mountingarrangements and all required hardware. The work shall include proper fixing, connection, testingand commissioning of the DB compatible with concealed wiring system as per manufacturer'sspecifications and direction of Engineer-in-Charge. | — | — | — | 4,903 | |
| — | 25.00 | — | — | ||
| Supply, fitting, fixing, testing, installation & commissioning of 45 Watt outdoor type LED street light fitting made up of pressure die cast aluminum housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. The street light must be conforms to the technical specification i.e. attached in the tender document. The whole work shall be executed as per the direction of Engineer in charge at site. | — | — | — | 1,11,649 | |
| — | 1.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of 12 way LT Panelsuitable for concealed wiring system, complete with suitable enclosure, bus bar arrangement,internal wiring, terminals, mounting accessories and all necessary hardware. The LT panel shallcomprise of the following protective devices: (i) 250 Amp TPN MCCB, C Curve - 1 No., (ii) 100 AmpMCCB, C Curve - 2 Nos., (iii) 63 Amp, 4 Pole MCB, C Curve - 4 Nos., and (iv) Over Voltage Release - 4Nos. The panel shall be complete with phase indication, neutral and earth arrangement, proper cableentry provisions, internal connections and all required accessories. The work shall include fixing,termination, testing and commissioning of the complete LT panel compatible with concealed wiringsystem as per applicable IS/IEC standards, manufacturer's specifications and direction of Engineerin-Charge. | — | — | — | 1,62,475 | |
| — | 12.00 | — | — | ||
| Supply,erection, installation & commissioning of 6 Mtr long Octagonal pole hot dip galvanized minimum 65 micron zinc coating with sectional dia 70 mm (top),130 mm (bottom).overall sectional thickness 3 mm complete with base plate of size (220x220x12)mm, 4 nos 600 mm long foundation bolt of suitable dia along with pipe cap type pole bracket 1000 mm long double arm made with suitable cap pipe 48.3 mm,3.25 mm thick arms.Junction plate made of 6 mm thick Bakelite sheet with 10 amps SP MCB c curve & 4 nos end terminals to be mounted inside the base compartment of Octagonal pole.The work will also include supply and erection of PCC/RCC works for foundation of size 55 cm x 55 cm and depth 1 Mtr below GL and height 20 cm above GL in proportion 1:2:4 with stone chips of maximum aggregate size 20 mm and less including cement,sand & provision of 75 mm dia pvc pipe for cable entry with excavation of earth for foundation of all depth and all places,nature and condition of soil including de-watering,shoring, shuttering, batchning,mixing,placing,leveling,carrying,etc and refilling the pit after completion of foundation work from excavated earth or borrowed pit by contractors own arrangement for octagonal pole.(considering SBC of soil is 10 Ton/sq.Mtr) | — | — | — | 77,189.52 | |
| — | 800.00 | — | — | ||
| Making of cable trench dimension 300 mm wide and 1000mm deep by excavation of earth. The cable shall be protected by laying of brick in 3 sides with filling of sand as per the direction of Engineer in charge at site (Outside track crossing) and backfilling of earth/ ballast. The work to be executed as per enclosed specification | — | — | — | 38,416 | |
| — | 100.00 | — | — | ||
| Making of bore for putting the cable under the track/road (Inside track/road boring) by crossing it through requisite dia as per direction of Engineer in charge at site. | — | — | — | 17,833 | |
| — | 1800.00 | — | — | ||
| Supply and wiring of main line (concealed type) by 1.1 KV grade HRFR PVC insulated single core 10 mm2 multistrand flexible copper cable conforming to IS:694/1990 through 25 mm dia. PVC conduit pipe including earth continuity by HRFR PVC insulated singe core 10mm2 multi strand flexible copper wire as per direction of Engineer Incharge at site. | — | — | — | 4,06,260 | |
| — | 2000.00 | — | — | ||
| Supply and wiring of sub-main line (concealed type) by 1.1 KV grade HRFR PVC insulated single core 6 mm2 multistrand flexible copper cable conforming to IS:694/1990 through 25 mm dia. PVC conduit pipe including earth continuity by HRFR PVC insulated singe core 6 mm2 multiflexible stranded copper wire as per direction of Engineer In charge at site. | — | — | — | 2,70,220 | |
| — | 600.00 | — | — | ||
| Supply and wiring of sub-main line (concealed type) by 1.1 KV grade HRFRPVC insulated single core 4 sqmm multistrand flexible copper cable conforming to IS:694/1990 through 25 mm dia. PVC conduit pipe including earth continuity by HRFR PVC insulated singe core 4 mm2 multiflexible stranded copper wire as per direction of Engineer Incharge at site. | — | — | — | 61,158 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, connection & commissioning of 300 mm sweep heavy duty exhaust fan. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site. | — | — | — | 6,878.3 | |
| — | 3.00 | — | — | ||
| Supply, fitting, fixing, installation, testing and commissioning of 25 litres capacityelectric storage water heater (geyser), suitable for 230V AC, 50 Hz single phase supply, completewith insulated storage tank, heating element, thermostat control, thermal cut-out, safetyvalve/pressure relief valve, wall mounting arrangement, necessary accessories, electricalconnections, fittings and all required hardware. The work shall include transportation, installation,testing and commissioning of the geyser complete in all respects as per manufacturer'sspecifications and direction of Engineer-in-Charge. | — | — | — | 49,929 | |
| — | 30.00 | — | — | ||
| Fabrication, supply, installation, testing and commissioning of international glow trilingual signage board single sided of different size and 20 cm width of 20 SWG thick aluminum sheet powder coated box with different color font and back surface, details given below, base made of white penaflex sheeting duly stretched of 627 gram per sq mt. (18.5 ounce per sq yard) thickness 0.52 mm & colored translucent vinyl sheeting base, subject matter and logo in different size and in different color given below with 20w/10w LED tube fitting as required for suitable glow of the board . Panaflex sheet should of reputed make. As per site incharge instruction.(2'x1.5'x10=240 sq feet) | — | — | — | 4,438.2 | |
| — | 20.00 | — | — | ||
| Supply and erection of earthing by 50 mm dia 3.60 mm thick 3 mtr long GI pipe with (25x5) mm GI strip & GI nut/bolts/washers etc as per CEE/MLGs diagram CEE/STD/1. | — | — | — | 10,866.6 | |
| — | 400.00 | — | — | ||
| Supply and drawing of 2.5 sqmm single core multi strand copper cable. | — | — | — | 18,340 | |
| — | 14.00 | — | — | ||
| Carrying and Erection of tubular pole 10 mtr long including digging the pit 1/5th of the total length.The whole work shall be executed as per direction of Engineer in charge at site | — | — | — | 6,515.88 | |
| — | 2.14 | — | — | ||
| — | 0.71 | — | — | ||
| — | — | — | 3,666.97 | ||
| — | 17.00 | — | — | ||
| — | — | — | 14,564.92 | ||
| — | 16.00 | — | — | ||
| — | 44.00 | — | — | ||
| Supply and fixing of pin insulator of size 80x105mm complete with 50X5mm MS 'D' clamp,Nuts & Bolts. | — | — | — | 920.04 | |
| — | — | — | 51,05,979.3 | ||
| — | 1.00 | — | — | ||
| Supply, fabrication, erection, installation, testing and commissioning of floor- mounted, cubical type, dust-proof, vermin-proof and rodent-proof LT panel board, 12-way, fabricated from minimum 16 SWG CRCA/MS sheet steel, chemically treated and finished with electrostatic dry powder coating of minimum 60-80 microns, complete with rigid welded construction, suitable MS angle-iron base frame, hinged and lockable doors with neoprene/EPDM gasket, cable alleys, detachable gland plates, metering compartment/module, electrolytic-grade 4-pole, 250 A copper busbars mounted on high-strength, non-hygroscopic insulated supports, suitable neutral and earth busbars, outgoing feeders with required MCB/MCCB/isolators of suitable rating and breaking capacity as per approved SLD, complete internal power and control wiring using suitably sized copper conductors/strips, FR/FRLS copper control wires with ferrules, cable glands, lugs, phase identification, feeder labels, danger plates, shrouds/barriers for live parts, effective earthing of all non-current carrying metallic parts with two external earth terminals, and all necessary hardware, accessories and interconnections,with all internal connection to be done by suitable size copper wire/strip connection comprising the following item no-2,3,4,5,6 (of schedule B) | — | — | — | 83,020 | |
| — | 1.00 | — | — | ||
| a.Supply, installation, testing and commissioning of 250 A, 4-pole MCCB, suitable for 415 V AC, with minimum 36 kA Icu and Ics = 100% of Icu, adjustable thermal-magnetic trip unit with adjustable overload and short-circuit settings, suitable for the specified LT system, conforming to IS/IEC 60947-2 (formerly IS 13947 Part-II), complete with all necessary terminals, interconnections, mounting hardware, accessories and other items required for safe, reliable and satisfactory operation. | — | — | — | 34,100 | |
| — | 1.00 | — | — | ||
| b. Supply, installation, testing and commissioning of 200 A, 4-pole, on-load changeover switch (Manual Transfer Switch), suitable for 415 V AC, 50 Hz, 3-phase, 4-wire system, without enclosure, with positive break/quick make-and-break mechanism, suitable for manual transfer between two independent power sources, with adequate short-circuit withstand capacity and suitable for continuous duty. The switch shall be mechanically interlocked to prevent simultaneous connection of both sources, provided with clearly marked Source-I/OFF/Source-II positions, suitable terminals for cable connection and complete with mounting hardware and all necessary accessories, conforming to the latest applicable provisions of IS/IEC 60947-6-1 / IS/IEC 60947-3 and suitable for installation inside the LT panel. | — | — | — | 14,700 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-16final_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].