Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAdmitted-Finance ECIL X ROADS HYDERABAD 500062 | MEDCHAL MALKAJGIRI | TELANGANA | 500062 | L1 | Admitted-Finance | |
| 2 | L2₹2.5 L+₹14,856.20 (6.41%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SSK ELECTRICALS L2 | SRI BALAJI ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C | 10 | Pts | 19,000 ₹22,420 | 17,000 ₹20,060 Lowest |
| 2.00 | Supplying and fixing following Modular base & cover plate with modular PVC boxes etc. as required. a) 4 module | 3 | set | 1,800 ₹2,124 | 1,650 ₹1,947 Lowest |
| 3.00 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. a} 20 A one way switch | 12 | Nos | 3,000 ₹3,540 | 2,760 ₹3,256.8 Lowest |
| 4.01 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit for table wiring as required. a) 3 x 1.5 sq. mm | 200 | Mtr | 24,000 ₹28,320 | 22,000 ₹25,960 Lowest |
| 4.02 | b) 3 X 2.5 Sqmm | 100 | Mtr | 16,000 ₹18,880 Lowest | 16,000 ₹18,880 Lowest |
| 5.00 | Supplying and fixing of following sizes of medium class FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required a) 25 mm | 60 | Mtr | 10,800 ₹12,744 | 9,600 ₹11,328 Lowest |
| 6.00 | Supplying and fixing of following sizes of GI Perforated Type Cable Trays with support etc. as required. a) 50 mm width X 50 mm depth X 1.6 mm thickness | 50 | Mtr | 47,500 ₹56,050 Lowest | 47,500 ₹56,050 Lowest |
| 7.00 | Supply and fixing 4ft 40W LED batten light with highperformance LED batten with an extruded aluminum body for durability and heat dissipation i/c pdg necessary supports and interconnections etc as reqd. Make Crompton: CCS-111-40-65-SL-DP-NWH or similar superior make | 40 | Nos | 72,000 ₹84,960 | 66,000 ₹77,880 Lowest |
| 8.00 | Supplying and fixing 22 W, 4 feet LED Batten fittings on surface of wall i/c making connections with copper conductor cable etc. as required. | 20 | No | 15,000 ₹17,700 | 14,000 ₹16,520 Lowest |
Tender Value
₹2.2 L
EMD Value
₹4,429
Closing Date
12 Oct 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
C M RAJU
BSNL KELLYS TE SEII OFF CHENNAI
Rearrangement of EI Fans in STR Package AC unit switch room at 3rd Floor HRD
2026_BSNL_292594_1
59 / EE-T/EC-II/CH/2026-27
Open Tender
Electrical Works
Item Rate
30 days
hadows raod TE CHENNAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL
₹4,429
14 Oct 2026
28 Sept 2026
13 Oct 2026
28 Sept 2026
12 Oct 2026
28 Sept 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C | 10 | Pts | - | - |
| 2 | Supplying and fixing following Modular base & cover plate with modular PVC boxes etc. as required. a) 4 module | 3 | set | - | - |
| 3 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. a} 20 A one way switch | 12 | Nos | - | - |
| 4.01 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit for table wiring as required. a) 3 x 1.5 sq. mm | 200 | Mtr | - | - |
| 4.02 | b) 3 X 2.5 Sqmm | 100 | Mtr | - | - |
| 5 | Supplying and fixing of following sizes of medium class FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required a) 25 mm | 60 | Mtr | - | - |
| 6 | Supplying and fixing of following sizes of GI Perforated Type Cable Trays with support etc. as required. a) 50 mm width X 50 mm depth X 1.6 mm thickness | 50 | Mtr | - | - |
| 7 | Supply and fixing 4ft 40W LED batten light with highperformance LED batten with an extruded aluminum body for durability and heat dissipation i/c pdg necessary supports and interconnections etc as reqd. Make Crompton: CCS-111-40-65-SL-DP-NWH or similar superior make | 40 | Nos | - | - |
| 8 | Supplying and fixing 22 W, 4 feet LED Batten fittings on surface of wall i/c making connections with copper conductor cable etc. as required. | 20 | No | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.45 MB
BOQ_341163.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .