Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹21.6 L
EMD Value
₹43,180
Closing Date
17 May 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Replacement of LT outdoor panel LT cables Switchgears and providing lighting at various locations of Industrial Health Unit HAL
7119
FM/NE-P/Advt./02/24-25 dt:16.04.24
Works
Electrical Planning and Contract Section-E and M Dept-FMD-Bangalore
₹0
₹43,180
17 May 2024
24 Apr 2024
24 Apr 2024
17 May 2024
HINDUSTAN AERONAUTICS LIMITED FACILITIES MANAGEMENT DIVISION
NAME OF THE WORK: "Replacement of LT outdoor Panel, LT Cables, damaged LT Cables, old LT Panels and Replacement of LT Switchgears in the existing panels at IHU, HAL." Cont.No: HAL/FMD/ER-2927/24-25
Name of the Contractor :
BILL OF QUANTITIES WITH SPECIFICATIONS
The tenderers are requested to read the following before quoting:
1 The payment terms shall be governed as per the terms indicated in General conditions of contract.
2 Basic Rate to be quoted for each item.Subject work is called on works contract basis and prevailing GST of 18% has been added in the BOQ on overall total. Any revision on this GST rate is to HAL account.
3 Sucessful offer that is L-1 (Lowest offer) will be determined including GST.
4 Amount towards GST will be paid along with RAR payment against invoice.
5 The tenderers are requested to abide by the rules of prevailing GST act.
6 This BOQ specification has to be read in conjunction with technical specifications and tender drawings. Any ambiguty in these have to be brought to the knowledge of contract section before submission of tender to avoid future claims/dispute.
Sl. No Specification of item Quantity Unit Rate in Figs excluding GST Rate excluding GST in words Amount Excluding GST in Figs (E=C*A)
Supply, installation, testing & commissioning of following Outdoor type LT Panel (PTA) as at BOQ Sl no-1 and 2
Design, fabrication, supply, installation, testing and commissioning of weatherproof cubicle type Outdoor LT Panel with front lockable door arrangement, suitable to be mounted on the existing brick pedestal/cable duct using M.S channel frame work, with cable entry from bottom with removable gland plates with required knock-outs, panel fabricated out of CRCA sheet steel folded and braced as necessary to provide a rigid support for all components, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-55, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns, with front lockable door(Double leaf with pad lock arrangment and tower bolt inside), and all doors and covers shall be fully gasketed using good quality EPDM gasket and/or rubber strips and ensure good lockable, durable door opening & closing mechanism, suitable meshed ventilator louvers with suitable cover,canopy type covering and Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, comprising of following switchgear and accessories complete in all respects and as directed by Engineer-in-charge.
Note:-1) Current density shall not exceed 0.8A/sq.mm for Aluminium bus bars in LT Panel
2)All MCCBs in the LT panels shall be adjustable with thermal settings(80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc. complete in all respects.
3)The operating height of the Panel shall not exceed 2.1 mtr. from FFL.
1 LT Panel (Security panel & old OPD panel ) 2 Nos 0.00
i) 1No- 250A, 415V gr. 36KA 4P MCCB.
ii) Lot - 300A TP + 150A N, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 1 Set-250/5A current transformers of suitable class and VA burden for metering.
v) 1no-(0-500V) range digital type Voltmeter with a push button option for selecting the phases.
vi) 1No 32 A 415V gr TP 36KA MPCB of for tapping power for metering and control circuit
vii) 1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
viii) 1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
i) 1No - 250A, 415V gr. 36KA breaking capacity, TP+NL MCCB
ii) 1No - 125A, 415V gr. 415V gr. TPN SDFU.
iii) 2Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
iv) 1No - 32A, 250V gr. 10KA breaking capacity, TPN MCB
2 LT Panel (Dialysis Control Panel) 1 No 0.00
i) 1No- 4Pole, 250A,415V 3 position manually operated changeover Switch-Disconnector including all accessories and ON/OFF indications front operating handle, etc.
ii) 1No- 250A, 415V gr. 36KA 4P MCCB.
iii) Lot - 300A TP + 150A N, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iv) 1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
v) 1 Set-250/5A current transformers of suitable class and VA burden for metering.
vi) 1no-(0-500V) range digital type Voltmeter with a push button option for selecting the phases.
vii) 1No 32 A 415V gr TP 36KA MPCB of for tapping power for metering and control circuit
viii) 1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
ix 1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
i) 4Nos - 125A, 415V gr. 415V gr. TPN SDFU.
ii) 1No - 63A, 415V gr. 10KA breaking capacity, TPN MCB
iii) 1No - 32A, 250V gr. 10KA breaking capacity, TPN MCB
3 Supply and fixing MCCB & SDFU's in the existing LT panels
a) Supply, fixing in the existing LT panel at Medical substation, testing and commissioning of 400A, 415V 36KA FP MCCB rating with thermomagnetic release including modification of bus bars with necessary interconnections complete in all respects as directed by Engineer-in-charge. 1 No 0.00
b) Supply, fixing in the existing Main LT panel and ETP panel , testing and commissioning of 125A, 415V TPN Switch disconnector fuse unit equal rating DIN type HRC fuses, front operating handle, door interlocking system, ON and OFF indication using LED module , testing and commissioning including modification of bus bars with necessary interconnections complete in all respects as directed by Engineer-in-charge. 2 Nos 0.00
c) Supply, fixing in the existing Laundry LT panel, testing and commissioning of 250A, 415V TPN Switch disconnector fuse unit equal rating DIN type HRC fuses, front operating handle, door interlocking system, ON and OFF indication using LED module including modification of bus bars with necessary interconnections complete in all respects as directed by Engineer-in-charge. 2 Nos 0.00
Note:- Scope includes removing existing switchgear in the panel
4 Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in HDPE pipes etc., testing & commissioning after laying of following size XLPE insulated Aluminium (Al) conductor 1100V gr., earthed Armoured (Arm) U.G cables as directed and as per technical specification and as detailed below. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
a) 3.5CX185 Sqmm Aluminium armoured conductor 500 Mtrs 0.00
b) 3.5CX50 Sqmm Aluminium armoured conductor 40 Mtrs 0.00
5 Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 KV grade as per CPWD specification and as required:
a) 3.5C x 185 Sqmm.Al Arm LT cable. 8 Nos 0.00
b) 3.5C x 50 Sqmm.Al Arm LT cable. 4 Nos 0.00
6 Brick pedastal
a) Providing and laying cement concerte of 1:4:8 ( 1 cement :4 coarse sand (zone-III) derived from normal sources /M-Sand :8 graded stone aggregate 40mm normal size derived from natural sources) as per CPWD specification and as directed by Engineer In Charge. 0.3 Cu.Mtrs 0.00
b) Brick work with common burnt clay machine molded perforated bricks of class designation 12.5 conforming to IS: 2222 in Superstructure in cement mortar 1:6 (1 cement : 6 coarse sand/M-sand) as per CPWD specification and as directed by Engineer In Charge. 1.3 Cu.Mtrs 0.00
c) Providing and Laying cement concrete for coping and finishing 1:2:4 ( 1 Cement : 2 coarse sand (zone III) derived from natural source/ M-sand : 4 graded stone aggregate 20mm nominal size derived from the natural source) as per CPWD specification and as directed by Engineer In Charge. 0.25 Cu.Mtrs 0.00
d) Carrying out plastering using 12 mm cement plaster of mix, 1:6 (1 cement : 6 fine sand/M-sand) as per CPWD specification and as directed by Engineer In Charge. 12 Sq.Mtrs 0.00
a) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per CPWD specification and as directed by Engineer In Charge. 1 No 0.00
b) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per CPWD specification and as directed by Engineer In Charge. 2 Nos 0.00
c) Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm) as per CPWD specification and as directed by Engineer In Charge. 60 Mtrs 0.00
d) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required as per CPWD specification and as directed by Engineer In Charge. 50 Mtrs 0.00
8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan). Including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, including refilling of same soil as per CPWD specification and as directed by Engineer In Charge. 89 Cu.Mtrs 0.00
9 Carrying out Mechanized Horizontal directional drilling of soil under the existing road/gate way for laying 1run of HDPE pipe including supply and laying 1 run of 125 mm dia PE100 PN08 HDPE pipes, any ISI approved make conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 1Rx125mm"complete as directed by Engineer in charge. 16 Mtrs 0.00
10 Demolishing 1:4:8 Cement Concrete manually/machanical means including disposal of material as directed by Engineer In Charge and inlien with CPWD specifications. 0.2 Cu.Mtrs 0.00
11 Providing and laying in 1:2:4 (1 cementy: 2 coarse sand (zone-III)derived from natural sources/M-sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete as per CPWD specification and as directed by Engineer In Charge. 2 Cu.Mtrs 0.00
12 Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of suitable rating tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
a) 12 WAY Double door Horizontal MCB DB 1 No 0.00
b) 63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity. 1 No 0.00
c) 40 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity. 2 Nos 0.00
d) 32 amps. ratings , DP MCB, "C" curve, 10 KA breaking capacity. 1 No 0.00
e) 6-32 amps. ratings , sp MCB, "C" curve, 10 KA breaking capacity. 4 Nos 0.00
13 Supply and fixing on wall /on using suitable MS angle iron frame factory-built powder coated sheet metal enclosure for Supply & fixing of 20A DP MCB including Din channel complete in all respects and as directed by Engineer-in-charge. 2 Nos 0.00
14. a) Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in HDPE pipes etc., testing & commissioning after laying of 3Cx2.5 Sqmm XLPE insulated Copper (Cu) conductor 1100V gr., earthed Armoured (Arm) U.G cables as directed and as per technical specification and as detailed below. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.) 155 Mtrs 0.00
14. b) Supplying and making end termination with brass compression gland and copper lugs for 3Cx2.5sqmm of XLPE insulated copper conductor cable of 1.1 KV grade complete in all respects and as directed by Engineer-in-charge. 6 Nos 0.00
14. c) Supply & drawing in the existing steel conduit 3Cx2.5 sqmm PVC insulated 1100V gr. FRLS multi stranded copper wires with ISI mark including necessary interconnections complete and as directed by Engineer In-charge. ( from DB to Switch box sub mains) 90 Mtrs 0.00
15 Supplying and fixing of following sizes of 2mm thick Steel Conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required and as per CPWD specification and as directed by Engineer In Charge.
a) 20mm Conduit 70 Mtrs 0.00
b) 25mm Conduit 20 Mtrs 0.00
16 Supply and fixing of weather proof cable junction box with connecting terminals of size 104mm x 104mm x 70mm Hensel Cat. No. DK 0402 G or equivalent in Legrand/ Schneider/ Hagar make. The Box shall be mounted at suitable height for lighting fixture using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-66 complete in all respects and as directed by Engineer-in-charge. 6 Nos 0.00
17 Supply and fixing on existing wall/ceiling/purlins, testing & commissioning of surface mounting, Batten type 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output of 1600 lumens, comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, colour temperature shall be >6000K. LM80 certificate for LED tube shall be produced. Other standard accessories including necessary inter-connections and supply of 1No of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. The LED tube & batten shall be of Bajaj BLRB DB 118 /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL. 30 Nos 0.00
18 Supply, fixing to MS hook grouted to the ceiling at approx. 5mtr height, including grouted suitable MS hook to ceiling with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 80watts made out of diecast aluminium housing for better thermal management, Secondary lens optics for better distribution & uniformity, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 140 lm/watt and lumen output not less than 11200lumens, PF>0.90 and Colour temprature shall be ≥5700K, CRI>70, THD <10%, IP66/65 operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting shall be of Crompton model no: CIP-320-80-57-60D-HL5-GL-NSR/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced. 6 Nos 0.00
19 Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class 2mm thick PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required from switch board to light point. (as per detailed CPWD specifications for Group C wiring)
a) Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 1 Pts 0.00
b) Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 12 Pts 0.00
20 Providing and fixing of 40mm dia Class B G.I pipes complete with G.I fittings including trench and reflling etc. 40mm dia nominal bore and as per CPWD specification and as directed by Engineer In Charge. 5 Mtrs 0.00
21 Supply, fabricating and installing of 300x50x2mm size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures upto a height of 3/4mtrs from FFL., including supply & fabrication of M.S angle supports and fixing hardware complete in all respects and as directed by Engineer in charge . 25 Meter 0.00
22 Disconnecting/dismantling & removal of the following items as-is-basis without any damage and handing over the same to the place as shown by Engineer-in-charge/Plant Maintenance department of Industrial Health unit (HAL Hosiptal) (not more than 1 KM) including loading, transportation, unloading etc., complete in all respects and as directed by the engineer-in-charge. 1 LS 0.00
i)Disconnecting & dismantling of 1 Set of Industrial Outdoor type existing LT panels with comprising of incoming of 1No 250A MCCB and outgoing of 1No 250A MCCB, 1No 125A SDFU, 3Nos of 63A MCB at Security gate area.
ii)Disconnecting & dismantling of 1 Set of Industrial Outdoor type existing LT panels with comprising of incoming of 250A MCCB - 1No and outgoing of 1 No. 250A MCCB,1No 100A SDFU,2Nos. of 63A MCB, 1No 32A MCB at Industrial health unit area.
ii)Disconnecting & dismantling of 1 Set of Industrial Outdoor type existing LT panels with comprising of incoming of 250A MCCB - 1No and outgoing of 1 No. 250A MCCB,1No 100A SDFU, 2Nos. of 63A MCB, 2Nos 32A MCB at Old OPD area.
iv) Disconnecting, re-routing and Reconnecting existing LT cables of the above panels. (Note:(i)Scope including supply and providing cable End termination for the existing outgoing cables of panel (ii) Scope includes Excavation, concrete cutting, reconcreting)
Note: 1. The quantity indicated are only approximate. 2. The tenderers are requested to visit the site and acquaint themselves with the present conditon and quote accordingly. 3. No extra claims will be entertained at a later stage.
23 Removing of existing cement slab(cover)/ Chequerred plate from the existing cable duct/ Drain including sand if any & repositioning the existing cement slab(cover)/Chequerred plate on the existing cable duct after cable laying & re-filling the existing sand, as-is-basis, without any damage to the cement slab including closing the joints with 1:6 cement mortar and as directed by Engineer-in-charge.(Measurement will be taken along length of the duct) 25 Mtrs 0.00
Total Amount Excluding GST 0.00
Add 18% GST 0.00
Total Amount Including GST 0.00
Total Amount inclusive of GST In Words
HINDUSTAN AERONAUTICS LIMITED
Facilities Management Division
Pre-Qualification Profile (To Be uploaded along with Part A)
Tender Ref No. or Contract No.: HAL/FMD/ER-2927/24-25
Name of Work: Replacement of LT outdoor Panel, LT Cables, Switchgear and providing lighting at various locations of Industrial Health Unit, HAL.
Estimated Amount in Rs.: 2159000
Tender Notice Date: [DD/MM/YYYY] 04-16-24
Sl.No Description Details Enclosed / Not Enclosed Remarks
1 Name of the Individual / Firm / Company: * Mandatory Please Enter Name of the Individual /firm /company
2 Type of ownership PleaseEnter Type of Ownership
If Other, please specify
3 Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc., Please enter Details of Constitution
4 Address for correspondence: Please Enter Address
5 Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No. Related Document to be Uploaded to eProcurement Portal (Note Cancelled cheque leaf to be uploaded)
Name of the Bank
Type of Account
6 PAN No.: Please Enter Pan NO
7 Average annual financial turn over during the last 3 years, ending 31st March of the previous financial year [ should not be less than 30% of Amount put to tender] 4999999 3
YEAR TURN OVER IN Rs: Enclosed / Not Enclosed REMARKS 5000000 2
2022 – 2023 Rs: Please Enter Turn over in Rupees for all the 3 years 7499999 2
Average annual Financial turn over 0.00 647700.00
Avg Annual Turnover criteria is not met 10000000 1
8 Details of Registered Contractor
If Registered Contractor with HAL Yes/ No [for Similar nature of work] Documentary proof to be Uploaded to e-Procurement Portal * Category: E = 75.00 Lakhs upto ` 100 Lakhs F = 50.00 Lakhs upto ` 75 Lakhs G = 25.00 Lakhs upto ` 50 Lakhs H =10.00 Lakhs upto ` 25 Lakhs I = 5.00 Lakhs upto ` 10 Lakhs J = 2.00 Lakhs upto ` 5 Lakhs K = Below ` 2 Lakhs 0 7 E 1
Registration No. 199999 7 F 2
Category 200000 6 G 3
PEMD Amount ( If paid ) 499999 6 H 4
9 PF No.: Please Enter PF NO
10 ESI No.: Please Enter ESI NO
Location of Agency/organisation: Please Enter GST Details
Any Special Status of the Unit i.e. DTA, EOU, SEZ, FTWZ
Registered under regular scheme or Composition Scheme or Not Registered Related Document to be uploaded in ePortal
12 Contact details
Contact person name Please Enter Contact person Name
Mobile No. Please Enter Mobile No
Ph. No. with STD code
FAX No. with STD code #N/A #REF!
13 Valid Electrical contractor licence of appropriate voltage issued by any state Govt. under clause 45 of Indian Electricity Rules 1956 and as amended from time to time or to declare engage an electrical contractor who has the above mentioned licence and requisite experience. Please SELECT YES OR NO
14 I.T Returns for past 03 years 999999 5 J 6
Assessment year 2023-24 Please Select 'Yes' ' No' for IT Return for All Three years 1000000 4 K 7
Assessment year 2022-23 2499999 4
Assessment year 2021-22 2500000 3
15 Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued within a period 12 months from the final date of submission of tender. solvency cal
Name of Bank & Branch: Please Enter Details to 'Name of the Bank' , 'Date of Issue','Value in C89``Rs. in Lakhs 04-16-24 28-Jun 0 40000
Date of Issue[MM/DD/YYYY]: 200000 40000
Value of Rs. In Rupees: 200001 150000
Solvency value is NOT as per NIT
16 Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender should be either of the following: [Work completion certificates along with LOA/PO/WO should be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated amount put to tender. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated amount put to tender. (iii) ONE similar completed work costing not less than the amount equal to 80% of the estimated amount put to tender. 863600 500001 250000
Completed similar works during last 7 years Please Select %of similar works completed during last 7 years 1000000 250000
Work No I Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 1000001 500000
Brief Description of Work: 2000000 500000
Completed value of Work in Rs. Lakhs: 2000001 1000000
Date of Commencement of Work [DD/MM/YYYY] 4000000 1000000
Date of Actual Completion of Work[DD/MM/YYYY]: 4000001 2000000
Work No II Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 10000000 2000000
Brief Description of Work: Please Enter Details for Work No II
Completed value of Work in Rs. Lakhs:
Date of Commencement of Work[DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]: work done
Work No III Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 04-16-24 2555
Brief Description of Work: Please Enter Details for Work No III 04-18-17
Completed value of Work in Rs. Lakhs:
Date of Commencement of Work[DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
17 Details of person holding the power of Attorney :
Name Related Document to be Uploaded to eProcurement Portal
Mobile No. Please Enter Details for Person holding Power of Attorney
Ph. No. with STD code
FAX No. with STD code
18 DECLARATION I
The document being viewed / downloaded from the website and having read & understood all the contents of the tender document mentioned under Pre-qualification criteria, technical bid ( Page 1 to 169) and price bid do hereby accept all the terms and conditions laid down in the said Tender document and will abide by the same on acceptance and award of work. Please Accept the Declaration I
19 DECLARATION II
I/We declare and confirm that - 1. All information and attachments submitted along with this offer are true and correct. 2. I/We are aware that any false information provided herein will result in the rejection of my offer . 3. I/We shall not make refund claims of expenditure incurred in processing this offer. 4. I//We are aware that document sought only be uploaded for evaluation of offer. 5.I/We shall not associate nor has been associated in the past, directly or indirectly with consultant or any other entity that would prepare the design, specification and other documents of the project. Please Accept the Declaration II
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
Technical_Bid_ER2927.pdf
TENDER_DOCUMENT • 3.57 MB
Tender_Drawing_No_1.pdf
TENDER_DOCUMENT • 0.06 MB
Tender_Drawing_No_2.pdf
TENDER_DOCUMENT • 0.06 MB
Tender_Notice.pdf
TENDER_DOCUMENT • 0.07 MB
Tender_Drawing_No_4.pdf
TENDER_DOCUMENT • 0.06 MB
PQ_FreeView.pdf
TENDER_DOCUMENT • 0.04 MB
Tender_Drawing_No_3.pdf
TENDER_DOCUMENT • 0.05 MB
Tender_Drawing_No_5.pdf
TENDER_DOCUMENT • 0.05 MB
PB_FreeView.pdf
TENDER_DOCUMENT • 0.12 MB
Corrigendum_No_1.pdf
TENDER_DOCUMENT • 0.04 MB
Price_Bid.xlsm
TENDER_DOCUMENT • 0.07 MB
Undertaking_Letter_EC2926.pdf
TENDER_DOCUMENT • 0.02 MB
ECS_Formet.pdf
TENDER_DOCUMENT • 0.01 MB
Check_List.pdf
TENDER_DOCUMENT • 0.01 MB
PQ_ER2927.xlsm
TENDER_DOCUMENT • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .