Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.0 LAccepted-AOC BHWANIGARH DITY GHAGGAR BRANCH CANAL SYSTEM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | ₹31.0 L | 1 | Accepted-AOC L-1 |
| 2 | 2₹3.2 CrRejected-AOC 17 C LADHOWALI ROAD OPP G G S C SCHOOL JALANDHAR | ₹3.2 Cr | 2 | Rejected-AOC L-2 |
| Sl No | Description | Qty | Unit | TARSEM CHAND GARG CONTRACTOR L1 | RAKESH KUMAR CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. Depth upto 0 to 1.5 mtr. | 1 | Cum | 97 ₹97 | 100 ₹100 |
| 2.00 | Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. Depth upto 1.5 to 2.25mtr. | 1 | Cum | 101 ₹101 | 108 ₹108 |
| 3.00 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. | 1 | Cum | 191 ₹191 | 187 ₹187 |
| 4.00 | First class burnt brick laid in cement sand mortar 1:6 for bed and side wall [Item No 11.3(i)]. | 1 | Cum | 6,450 ₹6,450 | 6,599 ₹6,599 |
| 5.00 | 10mm thick cement plaster 1.4 on sides walls (-) Rs.1.25/- for scaffolding. | 1 | Sqm | 176 ₹176 | 181 ₹181 |
| 6.00 | 10mm thick cement plaster 1:4 on bed and top. | 1 | Sqm | 137 ₹137 | 141 ₹141 |
| 7.00 | Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement (CSR
Item No 10.13 (a) (i) | 1 | Cum | 10,192 ₹10,192 | 10,192 ₹10,192 |
| 8.00 | Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle | 1 | Cum | 5,264 ₹5,264 | 5,660 ₹5,660 |
| 9.00 | Cement concrete 1:4:8 with brick ballast 40mm gauge | 1 | Cum | 3,914 ₹3,914 | 4,209 ₹4,209 |
| 10.00 | Lowering, jointing and cutting of RCC pipes 250 mm dia into trenches & laying same to correct alignment complete | 1 | Metre | 131 ₹131 | 134 ₹134 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
12 Dec 2025, 9:00 amClosed
Divisional Engineer
O/O Divisional Engineer, Lehal PWRMDC Division, Patiala
Relining and Lining of Watercourse by laying UGPL of Outlet RD 2180-R of Mr.No-7 of Boha Disty Village Boha (Laying and Jointing of RCC UGPL system and other allied works in construction of watercourse)
2025_WR_154308_1
17/2025
Open Tender
Civil Works
180 days
Boha
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹1.3 L
Patiala
26 Dec 2025
24 Nov 2025
12 Dec 2025
25 Nov 2025
12 Dec 2025
25 Nov 2025
2 Dec 2025
Amount
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. Depth upto 0 to 1.5 mtr.
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. Depth upto 1.5 to 2.25mtr.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
First class burnt brick laid in cement sand mortar 1:6 for bed and side wall [Item No 11.3(i)].
10mm thick cement plaster 1.4 on sides walls (-) Rs.1.25/- for scaffolding.
10mm thick cement plaster 1:4 on bed and top.
Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement (CSR Item No 10.13 (a) (i)
Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle
Cement concrete 1:4:8 with brick ballast 40mm gauge
Lowering, jointing and cutting of RCC pipes 250 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 300 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 350 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 400 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 450 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 500 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 600 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 700 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 800 mm dia into trenches & laying same to correct alignment complete
Lowering, jointing and cutting of RCC pipes 150 mm dia for vent pipe into Trenches and laying same to correct alignment ( @2.50 metre / No)
Wrought Iron and mild steel ladders, framed grills, grating etc. complete fixed in position in D-tank.(CSR 2020 Item No.18.4)
Providing & fixing M.S. foot rests made of 23x25 mm square bar including fixing in Haudis complete with cement concrete 1:2:4 (CSR 2020 Item No.29.35 )
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-250 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-300 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-350 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-400 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-450 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-500 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-600 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-700 mm
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) DIA-800 mm
Centreing & shuttering for Concerte faces
Providing and fixing of Steel Shutter Gates Assembly in Main Pipeline complete in all respects.
Dismantling of Brick work in Cement, CSR 2020 - item no- 8.5 (b)
RAKESH KUMAR CONTRACTOR (BID ID -702455)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
1.02 MB
Tender Documents
Tender Documents • 0.04 MB
BOQ
BOQ • 0.30 MB
Download all tender documents and submit your bid