RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No Digital Multimeter ( 2 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) FEATURES Type Benchtop Benchtop Display (Digits) 6.5 6.5 Measurement Type True RMS True RMS Counts 200000 200000 Or higher MEASUREMENTS DC Voltage Range 1000 1000.0 1/6 DC Voltage Accuracy 0.005 0.005 DC Voltage resolution 0.001 1.0
Required0.001 AC Voltage Range 600 600.0 AC Voltage Accuracy 0.08 0.08
Required0.1
Required0.5
Required1 AC Voltage resolution 0.001 0.1
Required0.001 DC Current Range 10 10.0 DC Current Accuracy 0.005 0.005
Required0.05
Required1
Required1.5 DC Current resolution 0.001 0.001 AC Current Range 10 10.0 AC Current Accuracy 0.5 0.5
Required1
Required1.5 AC Current resolution 0.001 0.001 Resistance Range 100 100.0 Resistance Accuracy 0.08 0.08 Resistance resolution 0.001 0.001 Capacitance Range ( Micro farad ) 1 to 100 1 to 100 Capacitance Accuracy ( % ) 1.5 1.5 Capacitance resolution ( nF ) 0.01 0.01 Frequency Range ( KHz ) 300 300 Frequency Accuracy ( % ) 0.1 0.1 Frequency resolution ( Hz ) 0.001 0.001 Temperature Range ( Degree C ) -40 to 400 -40 to 400
Required-50 to 1000
RequiredNA Temperature Accuracy ( % ) 1.5 1.5 Temperature resolution ( Degree C ) 1 1 OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available
RequiredInternal Memory min. 5000 points/200 readings * 2/6 Computer Interface along with software Available * Dimensions ( mm X mm X mm ) - * Weight 376 * Other Features - * SAFETY Safety Rating Category II 1000 V of IEC 61010. Category II 1000 V of IEC 61010. Safety Certification UL
RequiredCE
RequiredCSA
RequiredTUV
RequiredVDE * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC
Required50 Hz +/- 3% through Adaptor * if Battery Operated
Requiredthen Type of Battery NA * if rechargeable
Requiredthen chemistry of the battery NA * if Non-rechargeable
Requiredthen size of the battery cell NA * number of non- rechargeable the battery/cell NA * Voltage of rechargeable Battery 0 * capacity of rechargeable battery(milli Ampere Hour) 0 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment - * WARRANTY Warranty 3 3.0 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Condition 55 * Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified Yes * 3/6 maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest Yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH Yes * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification Yes * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.