| 1 | L1₹24.6 LAccepted-AOC GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | ₹24.6 L Quoted ₹26.7 L | L1 | Accepted-AOC lowest Bid Valua |
| 2 | L2₹29.1 L+₹2.4 L (9.10%)Rejected-Finance | ₹29.1 L+₹2.4 L (9.10%) | L2 | Rejected-Finance Highest bid value |
| 3 | L3₹29.9 L+₹3.2 L (11.8%)Rejected-Finance | ₹29.9 L+₹3.2 L (11.8%) | L3 | Rejected-Finance Highest bid value |
| 4 | L4₹37.9 L+₹11.2 L (42.0%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | ₹37.9 L+₹11.2 L (42.0%) | L4 | Rejected-Finance Highest bid value |
| 5 | Rejected-Technical JAIN BUILDING KHARIDA MAIN ROAD KHARAGPUR 721301 WB | MEDINIPUR WEST | WEST BENGAL | 721301 | - | - | Rejected-Technical Rejected due to Category b(i) not found in enlistment documents. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Aug 2020, 6:00 pmClosed
Shri R Durga Shyam, EE, GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIRS AND REWINDING OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, GEYSERS/SOLAR HEATERS AND ALLIED WORK AT DOMESTIC AREA AND TECHNICAL AREA AT AF STN KALAIKUNDA
2020_MES_360121_1
8574/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹40,000
Yes
8 Oct 2020
10 Jul 2020
7 Aug 2020
10 Jul 2020
6 Aug 2020
24 Jul 2020
Amount
Taking down old ceiling fan/Exhaust fans/Wall mounting fans/ Air cirulators fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carry out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately (ii) Burnt out fan shall be kept separately and to be repaired (rewinded) in workshop/ AGE E/M yard and to be hanged in existing position after rewinding.
Supply only Bearing No 6201 for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6202 for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6203 for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6204 for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Rubber Bush for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge.
Supply only condenser 2.5 mfd for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Epcos/Tibcon/ Havells
Supply only condenser 4.0 mfd for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Epcos/Tibcon/ Havells
Supply only condenser 6.0 mfd for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge. Make : Epcos/Tibcon/ Havells
Lathe work of fan shaft any type / size for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of ceiling fan of sweep 1200 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of ceiling fan of sweep 1400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of ceiling fan of sweep 1200 mm (old model, Heavy duty of any make Kessal/ Usha/ Polar or any other make) with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Exhaust fan of 450 mm any make any model ,1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Exhaust fan of 380 mm any make any model , 1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Exhaust fan/ fresh air fan upto 300 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of wall mounted fan 400 mm sweep any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Pedestal fan 400 mm sweep any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Flame proof Exhaust fan upto 300/380 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Industrial Air circulator fan of any make any model and sweep with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
Supply & Fixing Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 as specified and directed by Engr- in - charge.
M & L Painting of ceiling fans/Exhaust fans/Pedestal fan/Wall mounted fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc as specified and directed by Engr-in-charge. Note :- If required synthetic enamel paint two coats it has to be done to remove the stains and to bring the proper finishing.
Supply and fixing 'U' clamp for hanging ceiling fan in ceiling to be fixed with 3" long anchor fastener 3 Nos for each clamps complete all as specified and directed by Engr-in-Charge.
Supply and Fixing ceilling Fan down rod heavy duty as per existing dia and length of 50 cm including brass nut bolts, double waher, rubber bush heavy duty and spilit pin washers etc complete all as specified and directed by Engr-in-charge.
Supply and fixing blade assy of celling fan of 1200 mm sweep (set of three) in replacement of make and colour as existing as specified and directed by Engr- in - charge.
Labour only for fixing of 25 ltr geyser at new or old location with mounting bracket , bolt , fasteners including taking down of unserviceable from its position at various location and capacities complete all as specified and directed Note:- (i) New geyser suppled by department under Sch -B item (ii) Old geyser to be deposited at MES store yard through RV and RV submitted alongwith FB.
Taking down of Gyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs thermostat ISI marked as per existing size, spares of geyser and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
Supply and fixing in repairs heating element 1.5 KW, ISI marked as per existing size, spares of geyser and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
Supply and fixing in repairs heating element 2.0 KW, ISI marked as per existing size, spares of geyser and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
Supply and fixing in repairs Indicator lamp with flexibe copper wire of suitable size Red/Green, spares of geyser and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
Supply and fixing in repairs PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
Supply and fixing in repairs copper apperture plate suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc, and testing after replacing the defective part for proper functioning of gyser complete all as specified and as directed.
S&F in repairs Heating element 1.5 KW, ISI marked as per existing type Make : Bajaj / Usha/Theta/ Haveels/ Crompton. (Note:- heating element replaced without taking down of geysers and other than in item No. 29) is measured under this item.
S&F in repairs Heating element 2.0 KW, ISI marked as per existing type Make : Bajaj / Usha/Theta/ Haveels/ Crompton. (Note:- heating element replaced without taking down of geysers and other than in item No. 30) is measured under this item.
Supply and replacement of 3 pin plug top AC-230 v 15 Amp. Make : Anchor/ L&T/Havells
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe including filling of distilled water and coolent in reservior including complete sevicing to keep the plant functional of capacity up to 200 LPD.
M&L in repair for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 200 LPD.
M&L in repair for replacement of electrical heating element of 2.0 KW (long thread type, as per existing), ISI marked, of solar water heater of cap up to 200 LPD. Make: Solar Element or equivelent as approved by GE.
M&L for replacement in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material as required and directed by EIC.
Taking down existing u/s fitting any type any size and S&F LED 18 Watt tube light fitting (T8 type) , including single end connection type LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj (Batten Cat No. BLRB-DB 118 box type batten suitable for 18 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj (retrofit LED tube lamp 18 Watt (Cat No:-BLRB 18W CW LED, Single end connection) or equivelent in Crompton / Havells as approved by GE. Note : (i) Make of batten and LED tube lamp should be of same make. (ii) Contractor shall give replacement warranty cetificate of LED lamp for min two years.
S&F in repair LED bulkhead light of 10W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protection ,PF>0.95 complete all as specified and directed by Engineer in charge. Make Bajaj (Cat Part: BIBWP 10W LED) or euivalent in crompton/ Havells/Wipro
Supply and fixing in repair of stepped type Modular electronic fan regulator 2 module , 100 watt flush type , (deluxe) on the existing hylam laminated sheet etc as required. Make: Anchor (Deluxe /Code:-14502) / L&T/ Havells
Supply and fixing in repair of stepped type electronic fan regulator 1 module (mini) 100 watt flush type , on the existing hylem laminated sheet etc as required. Make: Anchor (Code:-14501) / L&T/ Havells
Supply and fixing in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 11 watt LED lamp and taking out u/s CFL or LED bulb. Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Bajaj/ Crompton/ Havells
M & L for recess mounting downlight of capacity 12 Watt with aluminum die-cast body compact and sleek design , constant current LED driver , warm white , with fitting arrangement , rated input voltage 240 V , AC ,50Hz , complete all as specified and directed.(Make:- Bajaj Cat No:-BGSLO SLEEK 12 W WH RD/Phillps/CG/Crompton or as per existing fitting.
M & L for recessed mounting deep recessed adjustable down light round LED downlighter with dome shape opal diffuser , fancy type LED light of capacity 9 Watt with aluminum body compact and sleek design , constant current LED driver , warm white , coated spun aluminium housing , rated input voltage 240 V , AC ,50Hz , IP 20 complete all as specified and directed. (Make:- Bajaj Cat No:-BRDCSL 9 W WW PRO/Phillps/CG/Crompton or as per existing fitting.
S&F LED Flood light fittings of 100 Watts LED with secondary optics made out of pressure die cast housing with IP 66 protection etc complete all as specified and as directed by Engineer-in-Charge and taking down unserviceable fitting (Make:- Bajaj Cat Part No.BJFL 100 W LED I or equivelent in Havells / Philips as approved by GE.) Note : (i) Connection cable from source to light fitting deemed to be included in the item rate. (ii) At location where flood lights are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED flood light shall be properly connected with earth dolly provided with fittings and steel poles. (iv) Contractor has to arrange his T&P for installation of this light inside gymnasium/ squash court or hanger as per requirement and as directed by Engr-in-Charge. (v) Warranty certificate of minimum 02 year for light fitting to be submitted by the contractor.
S&F LED Flood light fittings of 50 Watts LED with secondary optics made out of pressure die cast housing with IP 66 protection etc complete all as specified and as directed by Engineer-in-Charge and taking down unserviceable fitting . (Make:- Bajaj Cat Part No.BJFL 50 W LED I or equivelent in Havells / Philips as approved by GE.) Note : (i) Connection cable from source to light fitting deemed to be included in the item rate. (ii) At location where flood lights are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED flood light shall be properly connected with earth dolly provided with fittings and steel poles. (iv) Contractor has to arrange his T&P for installation of this light inside gymnasium/ squash court or hanger as per requirement and as directed by Engr-in-Charge. (v) Warranty certificate of minimum 02 year for light fitting to be submitted by the contractor.
S&F pressure die cast LED security light luminaires, 25 W, 230V, IP 65 with all accessories, internally pre-wired & fixed on the out side wall through bracket, clamp, nut & bolt etc. and including connecting up to ceiling rose / connector with three core sheathed copper conductor cable of suitable sizes complete all as specified and directed including taking down old unserviceable one.
Supply and fixing PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 1.0 sqmm x 3 core complete all as specified and directed by Engr-in-charge.
Supply and fixing PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge.
Supply only LED Driver for LED strip of capacity 25W, IP65, complete all as specified and directed.
Taking down old unserviceable GI/Copper earth plate from soft and hard soil from any location complete all as specified and directed.
M&L Earthing complete with copper earth plate electrode 600mm x 600mm x 3 mm thick burried directr in ground (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts nuts, check nuts and washers of glavanised iron and as shown in electrical plate No 3 connected to earth test point including necessary excavation any type of soil and refilling of pit after placing the electrode with agriculture soil, removal of existing excavated soil upto distance of 100 mtrs. RCC chamber cover plate, wire mess, funnel, test point, 40 mm dia GI protection pipe medium grade and separate pipe of 40 mm dia medium grade GI pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper complete all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately. NOTE: 1. The unit rate includes for protection GI pipe and watering pipe of 40 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of Copper strip of size 20X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer. 5. Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. 6. Cost includes removal of excavated soil upto a distance of 100 mtrs.
M & L for laying of GI tube medium grade 25 mm bore with all fitting as required at site and fixed to wall and ceiling or laid in floor including connection with existing line complete all as specified and directed.
M & L for laying of GI tube medium grade 20 mm bore with all fitting as required at site and fixed to wall and ceiling or laid in floor including connection with existing line complete all as specified and directed.
Taking out old unserviceable GI/aluminium/copper earth wire/strip of any size and type in any height and any location complete all as specified and directed.
M & L for copper earth contInuity conductor of size 20 x 3 mm strip with insulator fixed to wall or drawn in conduit/pipe as required complete all as specified and directed. Note: (i) Insulator to be fixed on every 50 Cm distance and cost of insulator is deemed to be included in unit rate of item. (ii) Brass nut bolts (of minimum length of 40mm of suitable dia) and washer to be provided to connect strip to insulator and steel screw to be provided for fixing insulator to wall. (iii) Heavy duty porcelain insulator to be fixed, before fixing sample to be get approved by Engr-in-Charge.
M & L for GI tubing light grade 40 mm bore for copper earth contInuity conductor as in supports complete all as specified and directed.
S&F for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130x180x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation including taking down unserviceable one, complete all as specified and directed. Make : Hensel- Cat part No. KF 0600 H
M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block in junction box, including taking down unserviceable ones, complete all as specified and directed.
S&F in repair Surge protection device Type 1 + 2 to withstand implus current with 10/350 us wave to simulate lightining current. SPD having max contionous operating voltage - 440 Uc (v), I imp in KA(10/350 Us wave) - 12.5 KA , I max in KA(8/32 Us wave) - 80 KA, Pole 3+1 (3 Pole + Neutral), 4 module including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified and directed by Engineer in charge. Make ABB cat Part No. OVR T1-T2 3N 12.5-440s P QS (2CTB815710R4800) or equivalent in Havells/ L&T.
S&F in repair Surge protection device Type - 2, having max contionous operating voltage - 440 Uc (v), I max in KA(8/32 Us wave) - 40 KA, Pole 3+1 (3 Phase + Neutral), 4 module including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified and directed by Engineer in charge. Make ABB cat Part No. OVR T2 3N 40-440 P QS (2CTB803973R1400) or equivalent in Havells/ L&T.
S&F in repair Condenser 2.5 mfd, 240 Volts, in attending fan complaint complete all as specified and directed. Make: Epcos/Tibcon/ Havells
S&F in repair Condenser 4.0 mfd, 240 Volts, in attending fan complaint complete all as specified and directed. Make: Epcos/Tibcon/ Havells
NAVYUG CONSTRUCTION
Neetu Construction
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .