Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.6 L+₹1.3 L (5.23%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.7 L+₹2.3 L (9.42%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹26.8 L+₹2.5 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹28.6 L+₹4.2 L (17.3%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
22 May 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
REPAIR AND CLEANING OF SEWAGE LINE MANHOLES SEPTIC TANK ETC AND REPAIR TO GATES BOUNDARY WALLS FENCING HARD STANDING PATH AND DRAIN ETC IN THE AREA OF AGE BR II UNDER GEMIS MHOW
2024_MES_651203_1
8644/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
334 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹76,000
Yes
13 Jun 2024
25 Apr 2024
24 May 2024
25 Apr 2024
22 May 2024
8 May 2024
Amount
Excavation in trenches not exceeding 1.50m wide and n.exc 1.50m depth for foundation etc or for shafts, wells, cess-pits, manholes, pier holes and n.exc. 10 sqm on plan getting out in soft/loose soil complete all as specified
All as per item No 01 above but depth exc. 1.5m but n.exc 3.0m
Demolition and breaking up drain pipes (SGSW, AC or RCC ) of following size , set in cement mortar and disposal of unservicable materials and rubbish to a distance not exceeding 100m complete all as specified
150 mm dia
200 mm dia
Demolition of cement concrete (unreinforced) of any description in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete including sub base of floors complete all as specified
M&L for salt glazed stoneware drain pipe , grade 'A' laid in trenches and jointed in cement mortar 1:1 including necessary testing on completion for the followin size all as specified
150 mm dia
200 mm dia
M&L for concrete bed to drain pipes in cement concrete 1:4:8, type D2 using 40 mm graded stone aggregate including packing under and completely surrounding against the sides of pipes after they are laid and tested all as specified and as directed for the following size of pipes.
150 mm dia
200 mm dia
Dismandling PVC pipes with fittings of 75mm and 110mm bore
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps of the following bore :-
75 mm bore
110 mm bore
S&F PVC (SWR) bend of the following bore :-
75 mm bore
110 mm bore
S&F PVC (SWR) junction single (single 'T') equal or unequal of the following bore :-
75 mm bore
110 mm bore
S&F PVC (SWR) vent cowl for following bore
75 mm bore
110 mm bore
S&F in repairs 75mm dia PVC (SWR) floor / Nahani trap with grating including jointing to waste pipe fixed with solvent cement
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified.
M&L for 25mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floor to receive floor finishes, complete all as specified.
M&L for Coloured joint free Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile over and including15mm thick screed in CM(1:6) complete all as specified
M&L for coloured glazed ceramic tiles of size 450mm X 300mm X 7mm thick in vertical surface such dado,skirting etc set and jointed over and including 10 mm thick rendering in CM1:4 for backing of tiles, jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified.
S&F in repairs vitreous china squatting pan "Orissa Pattern" size 580mm x 440mm white with integral foot rests, including provision of cement concrete bedding and 'P' or 'S' trap as required complete all as specified
S&F in repair vitreous china wash down water closet pedestal pattern white excluding flushing cistern and flush pipes complete all as specified
S&F in repairs plastic water closet seat cover for pedestal pan, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified
S&F in repairs PVC low level flushing cistern 10 litres capacity with all internal fittings including flush pipe and fixing to supply pipe including PVC connection 600 mm long 15 mm bore with brass heads & washers with connections fixed complete all as specified
S&F in repairs vitreous china wash basin, white flat back size 550X400mm including CP waste coupling, PVC waste pipe and brackets fixing in position complete all as specified.
S&F in repair pillar taps (swan neck type) cast copper alloy with capstan head, screwed down ,high pressure with long screwed shanks and fly nuts fixed in 15 mm bore pipes complete all as specified
S&F in repair health faucet with flexible pipe of one metre length including wall hook for EWC complete all as specified and as directed.
S&F in repairs 15 mm stop cock cast copper alloy, screwed down high pressure chromium plated screwed both ends for iron pipe or for unions and fixed complete all as specified
S&F in repairs 15 mm bib cock two way with flange, cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed complete all as specified
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm
S&F in repairs 32mm dia PVC waste pipe 80cm long for urinals complete all as specified
S&F in repairs 32/40mm dia PVC waste pipe not less than 90cm long complete all as specified
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store.
S&F 15 mm GI tubing medium grade ISI marked with both ends threaded any length including cutting threading connection in new or old position and all type of GI fittng required at site for laid in trenches/walls/ceiling etc complete all as specified
S&F 20 mm GI tubing medium grade ISI marked with both ends threaded any length including cutting threading connection in new or old position and all type of GI fittng required at site for laid in trenches/walls/ceiling etc complete all as specified
Removal of surplus spoil / excavated material to a distance upto 50 m and depositing where directed at a level n exc. 1.5 m above the starting point.
Returning filling in approved earth including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified
Demolition of brick work any type, built in cement mortar including all quoins, arches, pillars etc complete all as specified
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cm 1:6 all as specified
All as per item No 37 but except brick. Note: Serviceable bricks obtained from demolition shall be reused
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surface of wall and finished even and fair without using extra cement complete all as specified
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping, channel, benching etc laid to shape and slope and finished even and smooth using extra cement including weathering, throating and necessary form work complete all as specified
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
M&L for Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete all as specified and directed. (Note:-Reinforcement shall be measured and paid separately under relevant item).
M&L for Mild steel TMT Bar 6 to 8mmm dia cut to length, bent to shape to required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild seel wire (anneled ) not less than 0.9mm dia or securing with clips quality confirming complete all as specified
M&L mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cracking, bending spirally to proper for columns, hooking end & binding with and inch mild steel wire not less than 0.9mm dia or securing with clips quality conforming to complete all as specified
M&L for Cleaning of septic tank /deep manhole /soakage well of any description and any depth by desludging, desilting and getting out all silts , sludge, organic,inorganic materials and other foreign matters such as sediment,sand,ash,grease,fibre,silts,roots ,vegetation etc by mechanically by using sewage sucking Machine with necessary pumping arrangement assembled in coverd tank vehicle and by plugging the incoming sewer line through combined high pressure water jetting suction (vacuum) type machine mounted on LCV/HCV and removing the sludge in covered vehicle outside MD land and disposing at a place meant of the purpose by local Muncipality authority etc Complete all as specified and directed by Engineer in charge .NOTE : (a) For measurement purpose depth of Sludge shall be the difference between depth of septic tank from sludge top and final depth of septic tanks cleared. (b) Manhole cover shall be refixed in septic tank with CM 1:4 after cleaning and spread bleaching power on top surface of septic tank @ 1 kg per septic tank and quoted rate shall be inclusive of above provision.
Cleaning of all blockage of any type of sewage line ( ie) branch sewer line, main sewer line etc, manholes of any size and depth, in any situation by way of cleaning/desludging by manually or mechanically or by way of any other suitable means including removing foreign materials as well as rodding (full through) of sewer lines and between the blocked manholes where required and ordered by Engineer-in-charge and keeping the sewage line all time functional; cleaning traps, water closet, soil waste/vent pipe, gully traps etc complete upto final drop out let into septic tanks or central sewage treatment plant and/or soakage well (working in foul condition) with taking precautionary measures with necessary equipment as required and applicable all as specified and directed. The sludge removed from the manholes and sewage line shall be removed to out side Defence land complete all as directed by Engineer-in-charge for entire area under AOR of AGE B./R-II
Note for Item No 47: Note (a) : Contractor shall provide / detail 03 (three) Nos safaiwala and 01 (one) supervisor per working day and report daily at 9.00 AM to the concerned JE/Engineer-in-Charge at MES office/complaint cell to receive /collect complaints every day ,attending and resolving the complaints immediately and report the status of complaint to JE at 5.00 pm on the same day and necessary records with user's signature shall be maintained by the contractor . (b) : If any of the Safaiwala/Supervisor fails to report daily to the concerned authority, a penalty of Rs. 700/-day shall be deducted from the payment of the contractor. (c) : The Safaiwala shall always be in posession of the cleaning tools like 6mm MS round bar/rod, plain flexible bamboo pieces, Trowel, Phawra, Spade and cleaning pump with wooden/PVC handle. The rate quoted shall deemed to be inclusive of the cost of T&P for maintenance/cleaning work.
Dismantling fencing wire mesh, any type
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete ,any section, including taking out embedded portion and making good disturbed ground complete all as specified
Excavating post holes or similar holes, each not exceeding 0.5 cum , getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified
M&L for PCC 1:2:4 type B2 using 40 mm graded aggregate as in foundation ,post, etc complete all as specified
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire. complete all as specified
Supply only Chain link MS galvanised fencing of size or type
S & F 11 to 15mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified
M&L for preparation of new plastered surfaces of walls and applying two coats of Acrylic Smooth exterior paint of required shade (@ 1.67 litre /10 sqm) over a coat of primer(@ 2.20 kg/10 sqm) of same make all as specified
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint all as specified
M&L for preparation of old treated surface of walls and applying two coats of cement base paint all as specified
M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achive the surface even and smooth for painting.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land all as specified
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in sub base, levelling course, etc complete all as specified
M&L for PCC1:4:8 type D2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified
M&L for 75mm thick cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in floor/ plinth protection finish the surface even and smooth with using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified
Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and as directed.
M&L for chequered cement concrete tiles (glossy finish) with grey cement and pigment of size 25cmX25cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM 1:6 complete all as specified
M&L for chequered cement concrete tiles (glossy finish) with grey cement and pigment of size 40cmX40cmX40mm thick ,set and jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM 1:6 complete all as specified
M&L for machine cut kota stone slab in flooring 20-25mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified
M&L for 60mm thick (glossy finish) machine pressed precast concrete interlocking paver block of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled with sand and stone dust as in levelling course of interlocking complete all as specified
M&L for providing precast cement concrete louvers and jallies 50mm thick (measured solid) with cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate , set in cement mortar (1:4) including all mouldings but excluding frame complete all as specified
Dismantling of Asbestos cement (corrugated / semicorrugated etc.) sheets in roof coverings complete all as specified
S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified
S&F 0.50mm thick (including coated thickness) pre-painted pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa Plain steel sheet as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified
Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in un-framed work complete all as specified
S&F Mild steel Hollow Section work in tubular trusses, purlins, rafter, tublar column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified
S&F Mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified
S&F Mild steel plates (Plain or chequered) as in shoe plate, base plate and gusset plates forming holes for roof frame work, trusses, rafters etc of grade Fe 410 WA. complete all as specified
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for preparation of new steel surface of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified
S&F in repairs reinforced conrete pipe class NP2 drain pipe of 450mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified including excavation earth work and and providing concrete bed to drain pipe including packing underand completely surrounding pipes with cement concree 1:4:8 type D2 including returning ,filling and removing the excavated soil complete all as specified .
PARIDHI CONSTRUCTION
M/S Parikshit Sharma
M/S Sunshine Construction
M/s Narendra kumar Agrawal
M/s ESS KAY Construction
S.D.TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .