Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.5 L+₹2.3 L (7.24%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹34.0 L+₹2.8 L (8.86%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹34.8 L+₹3.6 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.7 L+₹6.5 L (20.9%)Rejected-Finance HIG 05 SECTOR G LDA COLONY KANPUR ROAD LUCKNOW 226012 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226012 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38.3 L
EMD Value
₹77,000
Closing Date
2 Sept 2021, 6:00 pmClosed
GE West Lucknow
GE West Lucknow, 11 Sardar Patel marg, Lucknow Cantt-226002
SPL REPAIR TO BDY WALL OF CMP MD ACCN AND ADDN/ALT TO SHED NO T 39 AT RSD LUCKNOW UNDER GE (WEST) LUCKNOW
2021_MES_465075_1
GE/W/LKO/41 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Lucknow
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE West Lucknow
₹77,000
Yes
4 Oct 2021
4 Aug 2021
4 Sept 2021
4 Aug 2021
2 Sept 2021
18 Aug 2021
4 Aug 2021 - 11 Aug 2021
Amount
Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles etc. complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft/ loose soil complete all as specified and directed.
Removing surplus excavated material soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in concrete, brick work, masonary etc., including taking out embedded portion and making good disturbed gound complete all as specified and directed.
Dismantling plain or corrugated asbestos cement sheeting any gauge, thickness or similar pattern roof coverings complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area n. exc 1.50 Sqm each complete all as specified and directed. (Note:- cutting hole in wall is deemed to be included in the rate quoted)
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L brick work with old size fly ash bricks of class designation 75, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L brick work with old size fly ash bricks of class designation 75, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of wall and finished surface even and fair and applying two coats of cement based paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of wall and finished surface even and fair and applying two coats of cement based paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces including taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water complete all as specified and directed.
S&F Framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work quality conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L mild steel framed work such as posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting and/or welding etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. NOTE: Each line wire to be measured.
S&F Concertina coil fencing with punched tape coil 450mm dia (at stretched position), made out of hot dipped, galvanised steel wire coated with CLR anti corrosive paint, making diamond shape barbs with 18 SWG sheet, spring core 2.5mm thick wire with tape 0.52mm thick and weight of each coil should not be less than 7.50 Kg, each coil should have 50 rounds and should covers 6 RM length, fixed over and including 6 lines of horizontal RBT (reinforced barbed tape) wire or razor wire at points wherever coil touches the bottom of wire with the help of hog rings (14 SWG) and in between Y shaped angle iron post complete all as specified and directed. NOTE: (i) Hogging shall be fixed at a interval of 600mm centre to centre, wherever it touches with the razor wire. (ii) Overlapping of concertina coil and razor wire shall be 300mm. (iii) Y shaped angle iron post shall be measured and paid separately under respective items. MAKE: M/s Global Engg or M/s Specials steels Ltd or M/s Super Fence or other equivalent make as approved by GE.
S&F structural steel work with rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. and similar articles conforming to Fe-410W (Gde E-250) quality-A complete all as specified and directed. Note :- Work shall be carried out at the minimum height of 8 metre from ground level necessary T&P crane etc shall be used for proper execution of work. Quoted rate shall be deemed to include this aspect and nothing extra shall be paid on this account.
Fixing only structural steel work with rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. and similar articles complete all as specified and directed. Note :- Old roof truss shall be reused after necessary adjustment. Work shall be carried out at the minimum height of 8 metre from ground level necessary T&P crane etc shall be used for proper execution of work. Quoted rate shall be deemed to include this aspect and nothing extra shall be paid on this account.
S&F multi-rib TM profile, tensile strength 550 Mpa, colour coated 0.50mm thick pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet, having maximum pitch of 250mm c/c and minimum 30mm crest depth in length as per site requirement, the feed material manufactured out of 0.50mm (TCT) with coating of 18-20 microns top coat over 5 microns primer and 8-10mm alkaline back of zinc aluminium alloy of AZ-150, including the sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium 55% and silicon 1.5% with total mass coating of 150 gms/sqm on both sides having covered width 1020mm and return leg for proper side lap as in roof covering/ cladding and fixed with self tapping screws with EDPM seal complete all as specified and directed. Make: TATA Durashine or equivalent as approved.
S&F multi-rib TM profile, tensile strength 550 Mpa, colour coated 0.50mm thick pre-painted galvalume aluminium zinc coated GI based plain steel sheet, having maximum pitch of 250mm c/c and minimum 30mm crest depth in length as per site requirement, the feed material manufactured out of 0.50mm (TCT) with coating of 18-20 microns top coat over 5 microns primer and 8-10mm alkaline back of zinc aluminium alloy of AZ-150, including the sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium 55% and silicon 1.5% with total mass coating of 150 gms/sqm on both sides having covered width 1020mm and return leg for proper side lap as in roof covering/ cladding and fixed with self tapping screws with EDPM seal complete all as specified and directed. Make: TATA Durashine or equivalent as approved.
M&L Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L 20-25 mm thick Kota stone slab, machine cut and polished as in flooring, bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of stone, laid over and including 20mm thick screed bed in cement mortar 1:6, including rubbing, grinding and mirror polishing complete all as specified and directed.
M&L 20-25 mm thick Kota stone slab, machine cut and polished as in skirting, bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of stone, laid over and including 10mm thick rendering in cement mortar 1:4, including rubbing, grinding and mirror polishing complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall and finished surface fair and even complete all as specified and directed.
M&L for three coats of white wash on new plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L preparation of old steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
Mount International
M/S SWATI CONSTRUCTION
M/S Ingenuity Consultancy Services and Infrastructure Limited
M/s Vimal Traders
Allied Builders And Engineers
M/s Sultan Khan
M/S S S A ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .