Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
5 Oct 2026, 5:00 pm
SM_TENDER CELL
GNIDA OFFICE
Providing of 16 Mtr. High Mast and street light on Surajpur Kasna Road to Sector-Chi-V Under Pass (60Mtr. road) in Greater Noida.
2026_GNIDA_1189480_28
SM/(E-TENDER CELL)/2026/814 DATED-22.09.2026
Open Tender
Electrical Works
Percentage
180 days
GREATER NOIDA
REFER TENDER DOCUMENT
5 documents required · 5 mandatory
₹2,510
₹2.6 L
25 Sept 2026
25 Sept 2026
7 Oct 2026
25 Sept 2026
5 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | BOQ | - | - | - | - |
| 1.02 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
(UPPWD-2018/646) | 123 | Nos. | 21,430 | ₹26,35,890 |
| 2Supply & fixing of Street light fixture,powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), | |||||
| 2.01 | DCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shallbe of relevant BIS standard complete in all 51 DELHI SCHEDULE OF RATES (E&M)-2025 respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
(DSR-2025, 8.14.19) | - | - | - | - |
| 2.02 | 200Watt | 246 | Nos. | 4,498 | ₹11,06,508 |
| 3 | S/F of M.S. Rod for earthing with 2.5 m long solid 20mm dia hot dipped galonished M.S. Rod burried till the top reaches 1.7 mtr. Below the GL Complete with bolts & nuts and G.I. earth wire 7/14 complete in all respect.
GNIDA-SOR-2024, S. No.-41 | 173 | Nos. | 663 | ₹1,14,699 |
| 4 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
(DSR-2025-5.2) | 30 | Nos. | 5,608 | ₹1,68,240 |
| 5Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 5.01 | 3X2.5 Sqmm
DSR-2025 S.No.1.17.12 | 3,075 | Mtr. | 108 | ₹3,32,100 |
| 6Supply & laying of Aluminium conductor XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks onsides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (UPPWD-2018-501) | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.29 MB
PreQ_Pro_16mtr_High_Mast_Stre_Surajpur_Kasna_Sec_Chi5.pdf
Tender Documents • 1.65 MB
BOQ_2242349.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .