Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.0 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹27.0 L+₹1.2 L (4.48%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹32.7 L+₹6.8 L (26.4%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹34.5 L+₹8.7 L (33.6%)Rejected-Finance | L-4 | Rejected-Finance L-4 |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L1 | airstack india L3 | laxmi enterprises L4 | J P Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for taking credit to be measured separately including making good the disturbed portion/surface complete all as specified and directed. | 480 | Per point | 10 ₹4,800 Lowest | 10 ₹4,800 Lowest | 10 ₹4,800 Lowest | 10 ₹4,800 Lowest |
| 2.00 | M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated and (FRLS) unsheathed size 1.5 sqmm with PVC concealed Conduit Medium Grade ( dia. not less than 25 mm) with fixing accessories for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet including continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed. | 150 | Per point | 300 ₹45,000 | 300 ₹45,000 | 250 ₹37,500 Lowest | 250 ₹37,500 Lowest |
| 3.00 | All as per item No 2 above but for one 3/5 pin socket 5 Amp on same board, with 1.5sqmm wire, complete all as specified and directed.. | 30 | Per point | 150 ₹4,500 | 100 ₹3,000 | 199 ₹5,970 | 80 ₹2,400 Lowest |
| 4.00 | All as per item No 2 above but for one 3/5 pin socket 5 Amp on independent board with 1.5sqmm wire, complete all as specified and directed. | 40 | Per point | 400 ₹16,000 | 390 ₹15,600 | 250 ₹10,000 | 200 ₹8,000 Lowest |
| 5.00 | All as per item No 2 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm cable including continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm cable, complete all as specified and directed.
Note:- (For item 02 to 05 )
Cost for making good disturbed surface below existing point wiring taken out vide item No 01 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 02 to 05 as applicable shall be deemed to be included in the unit rate quoted against these items. | 50 | Per point | 400 ₹20,000 | 600 ₹30,000 | 499 ₹24,950 | 250 ₹12,500 Lowest |
| 6.00 | M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed size 1.5 sqmm (FRLSH) drawn in and including PVC casing and caping with fixing accessories for one light /fan point, controlled by one switch with pressed steel concealed terminal boxes covered with 3 mm thick laminated sheet including continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed . | 100 | Per point | 350 ₹35,000 | 255 ₹25,500 | 299 ₹29,900 | 200 ₹20,000 Lowest |
| 7.00 | All as per item No 6 above but for one 3/5 pin socket 5 Amp on same board with 1.5 sqmm wire. | 30 | Per point | 150 ₹4,500 | 100 ₹3,000 | 199 ₹5,970 | 50 ₹1,500 Lowest |
| 8.00 | All as per item No 6 above but for one 3/5 pin socket 5 Amp on independent board with 1.5 sqmm wire. | 40 | Per point | 350 ₹14,000 | 300 ₹12,000 | 299 ₹11,960 | 200 ₹8,000 Lowest |
| 9.00 | All as per item No 6 above but for 3/5 pins socket outlet 15 Amps independent with 4.0 sqmm cable including continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm. | 40 | Per point | 400 ₹16,000 | 500 ₹20,000 | 499 ₹19,960 | 200 ₹8,000 Lowest |
| 10.00 | S&F switch piano flush type/Bell push, 5 Amps, single pole one way 230 Volts , AC, complete all specified and directed | 480 | Each | 25 ₹12,000 | 30 ₹14,400 | 25 ₹12,000 | 20 ₹9,600 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 May 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT OF INTERNAL WIRING, SOCKETS, SWITCHES, SECURITY LIGHTS/FLOOD LIGHTS, SUMMER APPLIANCES , HOT WATER APPLIANCES, EARTHING PITS, LIGHTENING ARRESTORS , FLAME PROOF FITTINGS ETC AND OTHER E/M ITEMS AT AF STN CHANDINAGAR UNDER AOR OF GE
2025_MES_707732_1
GE (FBD)/AF-T-23/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹90,000
Yes
25 Aug 2025
10 May 2025
3 Jun 2025
10 May 2025
31 May 2025
17 May 2025
Amount
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for taking credit to be measured separately including making good the disturbed portion/surface complete all as specified and directed.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated and (FRLS) unsheathed size 1.5 sqmm with PVC concealed Conduit Medium Grade ( dia. not less than 25 mm) with fixing accessories for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet including continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed.
All as per item No 2 above but for one 3/5 pin socket 5 Amp on same board, with 1.5sqmm wire, complete all as specified and directed..
All as per item No 2 above but for one 3/5 pin socket 5 Amp on independent board with 1.5sqmm wire, complete all as specified and directed.
All as per item No 2 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm cable including continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm cable, complete all as specified and directed. Note:- (For item 02 to 05 ) Cost for making good disturbed surface below existing point wiring taken out vide item No 01 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 02 to 05 as applicable shall be deemed to be included in the unit rate quoted against these items.
M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed size 1.5 sqmm (FRLSH) drawn in and including PVC casing and caping with fixing accessories for one light /fan point, controlled by one switch with pressed steel concealed terminal boxes covered with 3 mm thick laminated sheet including continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed .
All as per item No 6 above but for one 3/5 pin socket 5 Amp on same board with 1.5 sqmm wire.
All as per item No 6 above but for one 3/5 pin socket 5 Amp on independent board with 1.5 sqmm wire.
All as per item No 6 above but for 3/5 pins socket outlet 15 Amps independent with 4.0 sqmm cable including continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm.
S&F switch piano flush type/Bell push, 5 Amps, single pole one way 230 Volts , AC, complete all specified and directed
S&F socket 3/ 5 pins, 6 Amp, flush type piano (multi purpose) 230 Volts , AC, complete all specified and directed.
S&F Socket 15 Amps, flush type, 3/ 6 Pin, 230 Volts , AC, complete all specified and directed.
S&F switch 15 Amps, flush type, 230 Volts , AC, complete all specified and directed.
S&F Modular switch, flush type, 5/6 Amps, single pole, one module, white colour 230 Volts , AC, complete all specified and directed.
S&F Modular switch, flush type, 15/16 Amps, single pole, one module, white colour 230 Volts , AC, complete all specified and directed.
S&F Modular socket, 3 pins combined, 5/6 Amp, flush type (multi purpose), two module ,230 Volts , AC, complete all specified and directed.
S&F Modular socket, 5 /6 pins combined, 15A/16 Amp, flush type(multi purpose) two module 230 Volts, complete all specified and directed.
S&F Modular, white cover plate with frame suitable for three module way 230 Volts , AC, complete all specified and directed.
S&F Modular, white cover plate with frame suitable for four module way 230 Volts , AC, complete all specified and directed.
S&F Modular, white cover plate with frame suitable for six module way 230 Volts , AC, complete all specified and directed.
S&F Ding Dong door bell, 230 Volts , AC, complete all specified and directed.
S&F Bell push flush type, 5 Amps, single pole, one way, 230 Volts , AC, complete all specified and directed.
S&F Modular, Bell push, flush type, 5 Amps, single pole, one way, 230 Volts , AC , complete all specified and directed.
S&F ceiling rose, PVC / Polycarbonate isolated body, surface backlite, 65x50mm, three terminals, 230 Volts , AC , complete all specified and directed.
S&F modular, stepped type, electronic fan regulator, flush type,2-way 230 Volts , AC , complete all specified and directed.
S&F stepped type, electronic fan regulator, flush type 230 Volts , AC, complete all specified and directed.
S&F Batten holder PVC/ Polycarbonate base / back suitable for LED lamp, 230 Volts, AC, complete all specified and directed.
S&F in repairLED Bulb, 9/10W, B-22, Pin type, 230 Volts , AC , complete all specified and directed.
S& F in repair PVC Combination Box type complete with switch & socket 5/6 Amp ,230 Volts, AC, complete all specified and directed.
S&F in repair PVC Combination Box type complete with switch & socket 15/16 Amp, 230 Volts, AC, complete all specified and directed.
S&F in repair plug top, 16 Amp, 3 Pin 230 Volts , AC, complete all specified and directed.
S&F in repair plug top, 5 Amp, 3 Pin 230 Volts , AC, complete all specified and directed.
S&F in repair AC plug, 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC , complete all specified and directed.
S&F in repair AC socket, 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC, complete all specified and directed.
S&F in repair single pole and neutral, sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB, complete all specified and directed.
S&F Skylite recess mounting,36W, LED 2'x2' luminaire integrated electronic driver, optics diffused, complete including electrical connection with copper cable from ceiling rose to fittings, including taking down old Unserviceable light fittings of any type and any size, complete all specified and directed.
S&F LED tube light fittings, 20W (4 feet), wall mounted, LED batten, extruded PVC heat sink, provided for efficient heat dssipation & integrated electronic driver optics, diffused complete including electrical connection with copper cable from ceiling rose to fittings, including taking down old U/S existing fittings, complete all specified and directed.
S&F LED 6000K (2’ feet), 10W Decorative, LED lighting fixture with extruded PVC heat sink, environmental friendly, energy efficient ready to use pack, including taking down old U/S existing fittings, complete all specified and directed.
S&F LED bulkhead luminaire, 10W, decorative type, as per sample complete including electrical connection with copper cable from ceiling rose to fittings and including taking down old U/S existing fittings, complete all specified and directed.
S&F LED building secuity light, 25 watt, made up of pressure die cast aluminium housing with mid power LED as lightening source and PC cover having top opening inbuilt LED driver with IP66 protection and impact resistance of IK-07 complete including GI bracket with nut bolts, washers etc including electrical connection with copper cable from ceiling rose to fittings and including taking down old U/S existing fittings, complete all specified and directed.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC casing caping and dismantling and taking down existing unserviceable wiring,, complete all specified and directed.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRLS sheathed copper cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed. Note:- (i) Cost of making good disturbed surface below existing point wiring taken out vide item No 42 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 42 as applicable shall be deemed to be included in the unit rate quoted against these items. Note (ii) for item No 41 & 42 :- 3RM of 6 Sqmm cable and one RM PVC casing caping/ conduit shall be measured as one RM.
S&F in repairs VTPN 4 way double door prewired distribution board TPN-DPX 125 MCCB including one No MCCB 125 Amps, 25 kA, 4 pole as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete and including taking down Old U/S VTPN DB's, complete all as specified and directed. Note : Rates of MCCB and MCB SPN/SP/TP shall deemed to be included in the quoted rates.
S&F in repairs Distribution board 4 way TP&N Double Door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB, complete all as specified and directed.
S&F in repairs single pole and neutral sheet metal enclosures for Distribution board (DB's) suitable for MCBs fitted with bus bar, Neutral link, Earth Bar and Din rail, 240 V, 50 Hz, supply double door SP&N DB system 12 ways, complete all as specified and directed.
All as per item No 45 above but 8 ways
All as per item No 45 above but 4 ways
S&F MCB, TPN, 63 to 100 Amps, 415V including all termnials, fitting etc, including taking down old U/S MCB, complete all as specified and directed.
S&F MCB, SPN, 40-63 Amps, 240V including all termnials, fitting etc, including taking down old U/S MCB, complete all as specified and directed.
S&F MCB, SP, 06 to 40 Amps, 240V, including all termnials, fitting etc, including taking down old U/S MCB, complete all as specified and directed.
M&L for rewinding of exhaust fan of size 250 to 600 mm sweep Including taking down ,dismantiling, opening ,descaling, adjustment, re-fixing , cleaning, greasing, painting, replacing minor spares (i.e nut, bolt,washers etc) and rewinding with proper size enamelled copper wire warnishing, complete all as specified and directed. Note :- Spare parts shall be measured and paid separately.
Supply only Ball bearing
Supply only Brass bushes
Supply only Exhaust fan GI louvers complete with nut & bolts etc.
Supply only Exhaust fan aluminium blade of any sweep with screws/bolts, nuts etc
M&L for servicing,taking down ceiling fan, Air circulator & wall mounted fans of any size and any sweep, removing, cleaning of dust, greasing of bearing including replacing and connecting up, complete all as specified and directed.
M&L for rewinding of ceiling fan, Air circulator & wall mounted fans of any size any sweep and any capacity of fans using super enameled copper conductor of suitable gauge including insulation varnishing, packing including taking down and refixing the fans in original position, complete all as specified and directed. Note:- spares parts shall be measured and paid separately.
Supply only Ball bearing
Supply only Brass bushes
Supply only 2.5 to 4.0 mfd capacitor
M& L for point wiring with HFFR PVC insulated, unsheathed cable with multi stranded copper conductor 2X1.5 sqmm single core 1100 Volt grade conforming to IS :694 and including surface mounted drawn through ERW steel conduit medium grade not less than 20 mm dia including conduit and conduit accessories fixed on wall /ceiling including 1x1.5 sqmm PVC insulated unsheathed multi stranded copper conductor HFFR single core (green colour ) as earth continuity conductor up to common earth and connected to common earth dolly for light point/fan control by one switch including taking down old U/S exiting wiring, complete all as specified and directed. Note :-(i) Flame proof switch shall be measured and paid seperately. (ii) All conduit accessories such as bends, Elbows, Tee, reducers, junction box etc deemed to be included in the rate quoted .
All as per item no 61 above but for one Flame proof socket, 16 amp, on independent board with 4 Sqmm cable including 4 Sqmm continuous earth wire, complete all as specified and directed.
S &F for Flame proof rotory switch with termination box in LM-6 enclosed in and including aluminium body enclosure with threaded cover and toggle action switch operated by shrouded knob, single pole, 16 Amps, 250V, 2P+ Earth with double direct entries through way switch including 20 mm dia ERW threaded rigid steel conduit (duly approved and tested ), complete all as specified and directed.
S&F for Flame proof switch socket & plug combined with termination box in LM-6 enclosed in and including aluminium body enclosure with threaded cover and toggle action switch operated by shrouded knob, single pole, 16 Amps, 250V, 2P+ Earth with double direct entries through way switch including 20 mm dia ERW threaded rigid steel conduit (duly approved and tested ), complete all as specified and directed.
Supply and fixing in repair LED light fitting, 1x20 Watt, flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die-cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc, complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed.
S&F in repair flame proof distribution board, SPN, 08 way with Bus bar weather proof in cast aluminium, LM-06 enclosure operated by externally spring type knobs, complete with M-25 cable entry to suit incoming cable and 08 Nos M-20 cable entries for outgoing from bottom, suitable for fixing on wall/column /steel structure duly epoxy powder coated with flame proof flexible metallic conduit up to 01 Mtr length :- INCOMING (a) MCB SPN-40 Amps-02 Nos OUTGOING (a) MCB SP 6 Amps -08 Nos (b) MCB SP 16 Amps-04 Nos
S&F in repair for commissioning & testing ESE based lightining arresstor Model name, Protech Streamer 20 (Protected area 32 meter Radius on Level 1 and 77 meter Radius on Level III ) single spike complete with chemical earthing all connections and acceessories for a range of 25 mtrs, complete all as specified and directed.
M&L for stranded copper conductor of size 70sqmm, single core, insulated flexible copper down conductor (cable) from Lightning arrester to Earthing properly fixed with saddles and on insulators, complete all as specified and directed.
M&L for installtion of GI Mast with insulator and necessary accessories 5 Mtr height including all necessary civil and grouting works, nuts bolts washers, complete all as specified and directed.
S&F in replacement Lightning, Strike Counter (6 digit) including all connections, fixing on wall etc nuts bolts, complete all as specified and directed.
M&L in repairs of Air termination, single pointed, Aluminium rod, 12 mm dia and 300 mm long, complete all as specified and directed.
M&L in repairs of Air termination, single pointed, copper rod, 12 mm dia and 300 mm long, complete all as specified and directed.
S&F in replacement for Test point, terminal block, made of gun metal or phosphorus bronze, size 75x75x25mm, drilled and screwed including 3 nos., 8mm dia, 25mm long hexagonal head screw, complete all as specified and directed.
S&F in replacement of Ceramic insulator of standard size for ligthning strip protection fixed in wall of one metre distance with suitable size screws, complete all as specified and directed.
S&F in replacement Copper strip, 20 x 3.15mm, fixed with top of insulator/saddles, fixing with screws , washer etc with help of drill machine for roof conductors and down conductors above ground and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
S&F in replacement Aluminium strip, 25 x 3.15mm, fixed with top of insulator/saddles, fixing with screws , washer etc with help of drill machine for roof conductors and down conductors above ground and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
M&L for Chemical earthing, Design, development, supply, commissioning and testing EHCC certified ground terminal earthing system, hollow tube solid bar CPRI tested for sensitive signal/Electrical equipments highly anti-corrosive long life severe wear conditions in the earth pit and of standard size ISI marked copper tube outside secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal conforming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete including PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, charcoal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test point, and earth lead exceeding 7.5 mtr are measured and paid separately.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for damaged earth pit chamber with fair finish of internal surface of concrete chamber of earth, complete all as specified and directed.
S&F in replacement of 80 mm thick, PCC pit cover, 320 mm x 320 mm, using PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) including necesssary form work and handle for removing the cover from pit with fair finish, complete all as specified and directed.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by charcoal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by charcoal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe including PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old U/S earthing, complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, charcoal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are including in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
All as per Item No 80 above but using GI Strip 25x4 mm as earthing lead.
M&L for earthing complete with copper plate earth electrode 60cmx60cmx3.15mm thick surrounded by charcoal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth not less then 1.5 mtr below ground level surrounded from all sides by charcoal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to copper earth lead strip of size 20X3.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe and arrangement of watering pipe including PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling/taking down old U/S earthing, complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, charcoal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are including in quoted rate and watering pipe, earth lead protection pipe, test point and earth lead exceeding 7.5 mtr are measured and paid separately.
Supply and fixing in repair Earth continuity strip, 20x3.0 mm copper strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc, complete all as specified and directed.
Supply and fixing in repair of Earth continuity GI wire of 4 mm dia or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc, as required 25x4 mm GI strip, complete all as specified and directed.
Supply, Fixing & laying 20 mm dia GI tubing 'light grade', used as protection pipe for earth lead wire in earthing, complete all as specified and directed. Note:- All required items and accessories, bend, joints, nut bolts, clamps etc are included in quoted rates.
Supply, Fixing & laying 40 mm dia GI tubing 'light grade', used as protection pipe for earth lead strip in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cable, complete all as specified and directed. Note:- All required items and accessories, bend, joints, nut bolts, clamps etc are included in quoted rates.
Taking down Geyser of any size and capacity after disconnecting all electrical and water connections, dismantling of geyser for checking of unserviceable parts, repair/replacement of worn out parts, re-assembling, testing, cleaning with chemical to clear choking due to scaling and refixing in its original location including making all necessary electrical & water connections , complete all as specified and directed. Note: Parts Shall be measured separately and paid for under ‘Supplied only’ rates here-in-after)
Supply only Geyser Element Tringular type 1.5 KW
Supply only Geyser thermostate for 1.5 KW.
Supply only Geyser Base assembly /syphon ( rupturing plate or U assembly) any make and type for 25 Ltrs capacity water heater complete 6/9 hole including replacement of rubber seal nuts and bolts, complete all as specified and directed.
Supply only Bottom cover plate with matching colour of geyser complete all as specified and directed by Engr-in-charge.
M&L for Glass wool of superior quality
S&F in replacement 15mm dia. Non-return valve, made out of cast copper alloy, scerwed both and internally suitable for iron pipe of size 15 mm, complete all as specified and directed.
S&F in replacement of Safety pressure valve, complete all as specified and directed.
S&F in replacement of indication lamp (pilot type) for 50 / 25 Ltrs water heater, complete all as specified and directed.
S&F in replacement Inner shell of Geyser Body( inner Tank ) made of steel ( as per suitable for existing) sheet of with themal insulation, complete all as specified and directed.
S&F in replacement Inner shell of Geyser Body( inner Tank ) made of copper ( as per suitable for existing) sheet of with themal insulation, complete all as specified and directed.
S&F in replacement Outer cover Body of (as per suitable for existing) cover for geyser as per sample, complete all as specified and directed.
M&L for in replacement Brazing, welding to any size of inner shell copper/steel tank at leaking spot of any capacity any type Geyser after the repair checking up throughly for leaking including replacement of worn out nuts,bolt and washer, complete all as specified and directed.
S&F in Repair Geyser Element for instant type geyser (as per suitable for existing) 3 KW, complete all as specified and directed.
S&F in Repair PVC connection, 15 mm size with PTMT nuts of length not less than 300 mm suitable for hot water & cold water geyser connection, complete all as specified and directed.
S&F in repair Heating element 3 KW with thermostat for electrical Back up, complete all as specified and directed.
S&F in repair cable, 3 core, 4 sqmm, FRLSH, PVC copper conductor, complete all as specified and directed.
M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core, complete all as specified and directed.
M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 16 sqmm 2 core, complete all as specified and directed.
S&F in replacement LED Street Light Luminaries 45 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light, Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down old U/S light, complete all as specified and directed.
S&F in replacement LED Street Light Luminaries 60 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down old U/S, complete all as specified and directed.
S&F in replacement LED Street Light Luminaries 70 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down old U/S light, complete all as specified and directed.
S&F in replacement LED Street Light Luminaries 90 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down old U/S light, complete all as specified and directed.
S&F in replacement of outdoor type LED flood light 150/170 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment and including taking down old U/S light, complete all as specified and directed.
S&F in replacement of outdoor type LED flood light 200/210 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment and including taking down old U/S light, complete all as specified and directed.
Supply and Fixing in replacement of LED driver 230 volt single phase of 45/50 watt, driver life >= 25000 Hrs efficiency - 85%, with output short circuit protection, complete all as specified and directed.
Supply and Fixing in replacement of LED driver 230 volt single phase of 60 watt, driver life >= 25000 Hrs efficiency - 85%, with output short circuit protection, complete all as specified and directed.
Supply and Fixing in replacement of LED driver 230 volt single phase of 70-90 watt, driver life >= 25000 Hrs efficiency - 85%, with output short circuit protection, complete all as specified and directed.
Supply and Fixing in replacement of LED flood light driver 230 volt single phase of 150/200 watt, driver life >= 25000 Hrs efficiency - 85%, with output short circuit protection, complete all as specified and directed.
S&F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325x220x150 mm with MS clamp 25 x 3mm made to shape with necessary nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers including MCB SP 6 amps and making incoming and outgoing connections by taking out loops of cable of any size incl necesary excavations and other civil works, complete all as specified and directed.
Material and labour for removing the existing street light from 9m / 11m / 13m / 15m high poles of any make, size, or shape, including disconnection of the electrical connection, and refixing the same at the existing location or at any other location on an existing pole at a height not less than 7 meters from the base of the pole. The light shall be fixed using a GI bracket fabricated from GI pipe of bore not less than 25mm and length not less than 120 cm, bent to the required shape, suitable for LED street light installation. The bracket shall include new clamps made from MS flat of size 30mm x 4mm thick. The work shall also include cutting, welding, drilling of holes, and provision of necessary nuts, bolts, and washers. All MS work shall be painted with one coat of red oxide primer followed by two coats of aluminium paint. Complete electrical connections shall be carried out using , 1.5 sqmm S/C wire passing through medium grade size 20mm conduit pipe of approximate length 6 meters. Work shall be completed in all respects as specified and directed.
S&F in replacement of cable PVC insulated un-armored for connection 1.5 sqmm x 2 core Copper conductor from junction box to street light fittings on poles including PVC flexible pipes and lugs, complete all as specified and directed.
Maintenance of street light fitting on pole / wall at any height, cleaning of complete fitting / fixture, removing carbon from connection, tighting of bulb etc without replacing any part and making street light functional, complete all as specified and directed.
S&F Astronomical time switches are used to control various loads according to sunrise and sunset time of contact rating 16 A AC1 with USB key, 1 channels and use of USB key for program download and upload daily, weekly, program, complete all as specified and directed.
S&F in replacement PVC conduit heavy duty 25 mm bore cut to size and fixed along the pole for cable protection, complete all as specified and directed.
Supply and connecting single core FR, PVC insulated copper stranded cable of size 1.5 Sqmm for street light/flood lights passing through pole hole/ GI Pipe/ PVC Conduit to junction box and connected elecrically including taking old U/S wire any type, complete all as specified and directed.
S&F in replacement GI tubing 'light grade' 40 mm bore, cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed.
S&F in replacement GI tubing 'light grade' 50 mm bore, cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) LT Pole No ___ or HT Pole No ____ , S/L Pole No _______ and Location code, not exceeding 30 cm high and also includes stop, commas, short lines, dashes, hypens, brackets etc as per requirement, complete all as specified and directed. Note : 10 Numbers of letters, figures and 10 Numbers of Stops, commas & short lines included in each job.
Supply,installation,commissioning and testing as in replacement of street light panel (Timeline LT distribution board) of time line rating 63 A single Pole/ 230 V,floor mounted factory fabricated weather and vermine proof protection class IP 54, protection from over load and short circuit. Switch On -Off street light on time schedule by incorporating an Ashtronomical time switch complete all as directed including required earth / excavation and taking out existing LT panel of any size, complete all as specified and directed.
Material & Labour for surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints including repairing and painting on coping with cement base white paint, complete all as specified and directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reaparing of coping with cement / PCC.
Supply, installation, connecting electrically and testing of street light panel box complete with Astroonomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size.
S&F 400W open constructed ballast, 240V 50Hz for HPSV lamps, complete all as specified and directed.
S&F 400W high pressure sodium vapour tubular clear lamp for HPSV lamps, complete all as specified and directed.
S&F Ignitor for 400W high pressure sodium vapour lamps, 240V 50Hz for HPSV lamps, complete all as specified and directed.
Material & Labour for overhauling, servicing, repairing of 3 phase induction motor 1.1 0 KW , 415 volt , 920 RPM, 50 Hz, single phase of high mast light including replacement of U/S parts and make full functioning of motor, complete all as specified and directed.
Material & Labour for overhauling, servicing, repairing of gear box of high mast light including replacement of U/S parts and makie full functioning of gear box, complete all as specified and directed.
M&L for Servicing of OLD/ UNSV SOLAR street light fitting including servicing and Cleaning of solar panel, Low maintenance tubular battery by filling of Distilled water and first charging including replacement of damaged battery terminals, securing of all electrical wire circuit and connections, reparing of damaged foundation complete system if required or as directed by Engr-in-Charge. Note:- 1. All type of T & P, Distilled water, control cable upto battery terminal, PCC, ladder & tripod etc required at site will be arranged by the contractor and rates for the same will be deemed to be included in the quoted rate. (Spares parts required to make functional of solar light shall be measured and paid seperately under relevant items as supply only in item No 136 to 139 )
Supply only Solar PV Module 74W( As per existing )
Supply only White LED based light source 12W( As per existing )
Supply only Driver of solar street Lights( As per existing )
Supply only Battery rating of 12V & 100 AH( As per existing )
S&F battery compartment box made up of MS sheet 2mm thick size suitable for battery with MS cover, locking arrangements & fixing accessories with inside weather proof coated & outside Aluminium paint including writing pole number in black colour paint etc,, complete all as specified and directed.
S&F in replacement of Integrated all-in-one Solar Street light (In-buit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K, 140 Lumens per watt Auto On/Off, overcharging protection including taking down old U/S and complete fixing and connection, all as specified and directed.
S&F Electronic timer 240V AC, adjustment time 6-120 Sec, complete all as specified and directed.
S&F in repair of Auto cut Electrical Battery Charger 12V DC, 5 Amp Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc, complete all as specified and directed.
S&F in replacement of Socket type aluminum lugs of 400 Sqmm by disconneting the cables removing the old unserviceble ones and replacing, complete all as specified and directed.
All as per item No. 144 but Socket type aluminum lugs 240 Sqmm
All as per item No.144 but Socket type aluminum lugs 120 Sqmm
All as per item No. 144 but Socket type aluminum lugs 95 Sqmm
All as per item No. 144 but Socket type aluminum lugs 70 Sqmm
All as per item No. 144 but Socket type aluminum lugs 50 Sqmm
All as per item No. 144 but Socket type aluminum lugs 35 Sqmm
All as per item No. 144 but Socket type aluminum lugs 25 Sqmm
All as per item No. 144 but Socket type aluminum lugs 16 Sqmm
Supply and errection in true vertical position of steel tubular, swaged pole, type 410 SP-31 , 09 mtr long complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws including painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer after errection and providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole, complete all as specified and directed. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
S&F stay assembly, complete with all accessories, such as stay plate 230X230X6 mm, stay rod 215 cm long and 16 mm dia with nuts including GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 and as directed incl taking down old unsv, complete all as specified and directed. Note: Only excavation and PCC work will be measured and paid separately.
M&L in replacement for pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm height and 65 mm dia with Galvanised mild steel spindle, two GI washer and one GI nut, complete all as specified and directed.
M&L for aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator, jumpring of any size as required at site including dismantling and taking down old U/S, complete all as specified and directed.
S&F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out, complete all as specified and directed.
All as per item No 158 above but exceeding 1.5 mtr deep but not exc 3.0 mtr deep.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart, complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point, complete all as specified and directed.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches, complete all as specified and directed.
M&L for sub class `B` bricks for cable protection, complete all as specified and directed.
Taking down UNSV LT Under Ground cable of any size, complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per Item Ser No 165 here in before but for 3.5 core 25 Sqmm.
S&F in replacement of 3 pole power contactor LT MNX 95 CONT, complete all as specified and directed.
S&F in replacement of 3 pole power contactor LT MNX 140 CONT, complete all as specified and directed.
S&F in replacement of 3 pole power contactor LT MNX 225 CONT, complete all as specified and directed.
J P Enterprises (BID ID -3304471)
airstack india (BID ID -3304542)
laxmi enterprises (BID ID -3304282)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .