Sh Pankaj Sharma
Kurukshetra University
Supply, Erection, Testing and Commissioning of 8 Passenger Machine Room Less Gear Less Elevator for Department of Statics and OR at KUK.
2026_HRY_553779_1
20260A89DAC4 2A3A 4FF3 B1F1 1DF5AC0DC68E1139KUK
Open Tender
Electrical Works
Works
270 days
Kurukshetra (Thanesar)
Supply, Erection, Testing and Commissioning of 8 Passenger Machine Room Less Gear Less Elevator for Department of Statics and OR at KUK.
2 documents required · 2 mandatory
₹1,180
₹30,980
Yes
12 Oct 2026
12 Oct 2026
2 Nov 2026
12 Oct 2026
2 Nov 2026
12 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [37.1.2]Supplying, installation, Testing and commissioning of the passenger
Machine Room less (MRL) lift having following main features:
a) MOTOR : Gearless lift drive comprising of high starting torque lift
duty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor of
proper rating with high efficiency shall be used.
b) Operation/Drive : Microprocessor based /PLC, AC Variable
Voltage variable frequency variable speed (V3F) vector control drive with
encoder feedback closed loop system shall be used for lift car and door
operation which shall be full collective selective operation hall call demand
response, UP/Down hall stops, main, Up/Down contactor with overload and
phase reversal relay and safety controls.
c) Traction Media: main hoist flat coated steel belt / rope. Thimbles
of spring permit adjustment of uniform tension for smooth operation of the
elevator Pulse belt monitoring system to avoid the cut in the belt.
d) Car : car should be with M S platform with bracings of adequate
size and to sustain the impact load cabin plus passengers with safety factor
of fire for steel with Anti-skid PVC flooring and side panels should be of
Stainless steel with hair line finish of sheet of grade 304 duty with S.S.
handrails . Car ceiling shall be steel finish with aesthetic appearances with
LED ceiling lights .The size of the car shall be taken as per available lift well
size and relevant BIS code of lifts. Car panel will also be of S S 304 grade
finished with emergency stop device, emergency alarm, mechanical door
safety device, full length infra-red curtain in car door, facility of
auto/attended mode. All car panel buttons and all floor switches must be
with brail language as per lift act. Agency shall also provide and install one
No. 2 MP , IR , IP based ceiling mounted Dome Camera in the car complete
with connecting cables and accessories (To be connected with existing CCTV
system in the Building) .The inspection unit shall be provided at the top of
the car.
e) Landing Doors: All landing door shall be fully automatic center
opening / telescopic made of hair line finish stainless steel grade 304 with
key holes and infrared curtains with unlocking facility from outside.
f) Emergency light: Appropriate rechargeable battery operated LED
emergency light in the car and along with alarm switch shall be provided.
g) ARD: Automatic rescue Device (ARD) shall be provided according
to passenger capacity with SMF batteries of approved brands.
h) Audio-Visual Indication: Audio visual indication in the lift car,
showing over loading such that doors kept open till excess load is removed.
i) Scrolling Indicators: Digital scrolling indicator system for up-down
arrow with floor position indicator shall be provided inside the car and at all
stops/floors.
j) Buffers: Spring buffers/PU Buffers shall be provided.
k) Car Fan: ENERGY EFFICIENT Car fan/blower with automatic
sleep timer shall be provided.
l) Voice Annunciator: Voice annunciator with suitable music shall be
provided in lift car.
m) Self diagnostics system for operational and safety parameters
shall be provided in control panel.
n) Mechanical/Electronic over speed governor, door key holes in the
floor doors, fireman switch shall be provided.
o) Permanent wiring in lift well with providing and fixing of electrical
distribution board complete with SP and TP MCB`s, proper numbers of light
points, with LED fixtures, exhaust fan, 2 nos copper plate /chemical
earthing with 8 SWG copper earth wire and plug points shall be provided by the agency. (Power supply of 3 phase 440 V shall be made available by
department in lift machine room.)
p) Agency has to provide all working drawings and documents to
comply latest BIS specifications and make proper liaison services for
obtaining all necessary permissions. 2. 8 passengers/544 Kg, 3 stops, rated speed adjustable up to 1.0 mtr/sec with 2 years comprehensive maintenance / DLP [Rate] | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_633667.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .