Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹12.3 L+₹46,999 (3.98%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹12.5 L+₹63,962.25 (5.41%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹12.8 L+₹95,294 (8.07%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹13.0 L+₹1.2 L (10.4%)Rejected-Finance H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME Secunderabad
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
Repair to plinth protection sunken portions nahani traps and stair cases in Md Accn and OTM in Zone I area under GE MCEME Secunderabad
2021_MES_492976_1
GE/MCEME/TOK/ 49 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
Class E category a(I)
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹30,000
Yes
24 Jan 2022
7 Dec 2021
5 Jan 2022
7 Dec 2021
3 Jan 2022
21 Dec 2021
60 days
Amount
Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:3) on sunken concrete floor surfaces mixed with integral water proofing compound finished even & smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge. Note : WPC shall be measured & paid separately.
M&L for rendering 10mm thick in CM (1:4) on concrete surfaces of roof padding with integral water profing compound @3% by weight of cement content (water proofing compound to be paid separately) finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M&L for PCC type E-2, 1:5:10 (using 40mm graded stone aggregate) as in filling and mass concrete as in sunken floors, complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in padding concrete (levelling course) on roof complete all as specified and as directed by Engr-in-Charge.
M&L APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaced by forced applicaion complete all as specified including removal of existing treatment complete all as specified and as directed by Engr-in-Charge.
M&L for priming plastered roof surfaces with bitumenous primer @ 0.3 Kg/sqm as per IS 3384 and providing water proofing treatment by applying 3.5 kgs/sqm Actctic Polyprophylene (Advanced APP torch on membrane mineral finish) having polyster film reinforcement stablised with fibre glass and finished on top with grey mineral slates torch on system of thickness 3mm by torch bonding including groove cutting and filling complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M & L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) 100/110 mm bore single socketed pipes in any length with rubber ring joints fixed to wall height upto 12 mtr height with clamps complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC(SWR) bend/shoe for 100/110 mm dia complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC (SWR) 75 mm dia floor trap, plain with grating including jointing with solvent cement and connecting to existing lines complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC (SWR) gully grap 125/110 mm setting and jointing with solvent cement and preparation of trap hole complete and connecting necessary connections complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 25 mm thick type B1 1:2:4 (20 mm graded agg ) as in sub base complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick screed bed or bedding layer of mortar CM 1:6 for laying of floor finishes complete all as specified and as directed by Engr-in-Charge.
M&L for non skid ceramic coloured dark shade tiles 7 to 8 mm thick, area of each tile exc 0.060 sqm but not exc .11sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for Glazed ceramic tiles in vertical surface 450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
M&L for Vitrified Ceramic coloured tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed of CM 1:6 and pointed in white or coloured cement to match etc. including dismantling existing tiles complete all as directed.
S & F in repairs, vitreous china squatting pan, 'orissa' pattern of size 580x440mm white, with integral foot rests including concrete bedding & inc. CI 'P' trap, 100mm, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (reinforced) of any descritpion complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs etc including necessary form work and set in CM 1:6, complete all as specified and as directed by Engr-in-Charge. Note:- Reinforcement will be measured and paid seperately
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster or cement lime plaster of any description including racking out joints and hacking for key and scrubbing down with water etc. complete all as specified and as directed by Engr-in-Charge.
M& L for rendering 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finsished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on surfaces of walls, complete all as specified and as directed by Engr-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments, complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete type B- 0, 1:2:4 (12.5mm graded aggregate) for coping or chamfered on edges, complete all as specified and as directed by Engr-in-Charge.
Demolition of precast concrete block masonry, built in cement mortar incl all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete Type C1, 1:3:6 (16 mm graded aggr) solid block masonry exc 10 cm in width and set in CM 1:6, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mm bore, complete all as specified and as directed by Engr-in-Charge.
S&F 15mm bore Bib taps fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engr-in-Charge.
S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified, complete all as specified and as directed by Engineer-in-Charge. (Make : Jaguar)
S&F in repair vitreous china EWC white including flush pipe, seat cover etc, including connection to drain (or out going pipe) and to flushing pipe anti syphonage pipes etc complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 15mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 20mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc.
S&F 20mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc.
NEWS CONSTRUCTIONS
B AND H CONSTRUCTIONS
VACON INFRASTRUCTURES
G SATISH REDDY AND CO
SAI RUPA CONSTRUCTIONS
BHEEMRAO PATIL CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .