Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC beingL1 | |
| 2 | L2₹5.6 L+₹20,691 (3.83%)Rejected-Finance 121004 | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹6.0 L+₹64,041 (11.9%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
11 Jul 2024, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
MAINT AND REPAIR TO CAPACITOR PANELS, RENEWAL OF EARTHING SYSTEM OTHER ALLIED WORKS AT AFAC UNDER AGE (I) (AF) COIMBATORE.
2024_MES_660157_1
8987_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
Class-E category-b (i)(see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF COIMBATORE
₹11,000
Yes
4 Sept 2024
15 Jun 2024
15 Jul 2024
15 Jun 2024
11 Jul 2024
29 Jun 2024
15 Jun 2024 - 28 Jun 2024
Amount
M&L for repair/servicing of capacitor panel 25 KVAR/30 KVAR/50 KVAR and carry out repairs such as dismantling of power contactros, auxillary contactors, CT Coil, checking the HRC fuse and replacement if any damaged, checking the control wiring and refixing all the components after proper servicing all as specified and as directed Note: Spare parts any required will be measured separately)
Supply only 10 KVAr capacitor duty contactors with built in surge suppressor. Make : L&T, Havells, Schneider, Legrand
Supply only 15 KVAr capacitor duty contactors with built in surge suppressor. Make : L&T, Havells, Schneider, Legrand
Supply only 33.3 KVAr capacitor duty contactors with built in surge suppressor. Make : L&T, Havells, Schneider, Legrand
Supply only 40 KVAr capacitor duty contactors with built in surge suppressor. Make : L&T, Havells, Schneider, Legrand
Supply only 20 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection complete. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 15 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 10 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 7.5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 4 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 3 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
Supply only 2 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S
M&L for servicing of LT Panel board double door with canopy by cleaning with blower/replacement of lugs if any, replacemenmt of burned out copper wiring if any, cleaning and tightening of MCCB terminal connections, rectifying the loose connections, repairing or easing of door locking arrangement including hinges all as specified and as directed.
Supply and fix MCCB four pole 160A, 36 KA, 415 V, adjustable type of existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed. Make: C&S /Siements/Indo asian/Havells /Schnieder
Supply and fix MCCB four pole 200A, 36 KA, 415 V, adjustable type of existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed. Make: C&S /Siemens/Indo asian/Havells /Schnieder
Supply and fix MCCB four pole 250A 36 KA 415 V, adjustable type of existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed. Make: C&S /Siements/Indo asian/Havells /Schnieder
Supply and fix MCCB four pole 630A, 50 KA 415 V, adjustable type of existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed. Make: C&S /Siements/Indo asian/Havells /Schnieder
Supply and fix MCCB 3 pole 25-100 Amps, 16 KA, 415 V, fixed type of existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed. Make: C&S /Siements/Indo asian/Havells /Schnieder
S&F 415 V 10 KA 'C' Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCB's all as directed. Make: C&S/Siemens/Indo asian/Havells/Schnieder
All as per Item No 20 here-in-before but TPN 16 to 32 Amp capacity
All as per Item No 20 here-in-before but TPN 40 to 100 Amp capacity
S&F 415 V 10 KA 'B' Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCB's all as directed. Make: C&S/Siemens/Indo asian/Havells/Schnieder
All as per Item No 23 here-in-before but TPN/FP 16 to 32 Amp capacity
All as per Item No 23 here-in-before but TPN 40 to 100 Amp capacity
Disconnecting the electric supply from the existing LT Panel/Transformer/LT poles and meggering the LT under ground cable any type & size for its IR value and ensuring the servicebility by LT megger, locating the faults by cable fault locating insturment suitable to locate and pin point faults in LT cables for any distance and reconnect the LT cable including jointing the cable at fault location with straight through cable jointing kit heat shrinkable type for 1100 volts grade cable with jointing material and accessories, cutting the bitumin road, Excavation in trenches nexc, 1.5m wide and not exc 1.5m deep and getting out complete in hard/dense soil for taking out and making good of disturbed surfaces as per existing finish all as specified and as directed. Note : Cable Joint kit will be measured and paid seperately.
Supply and fixing for straight through cable jointing kit heat shrinkable type joint for 1100 volts grade cable complete with jointing material and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured aluminium conductor cable for the size 70 to 150 sqmm all as specified and directed. Make - Raychem, M seal, Denson, 3M etc
Supply and fixing for straight through cable jointing kit heat shrinkable type joint for 1100 volts grade cable complete with jointing material and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured aluminium conductor cable for the size 185 to 240 sqmm all as specified and directed. Make - Raychem, M seal, Denson, 3M etc
Supply and fixing in replacement of power contactor type ML-1 25 Amp, 3 pahse 415 Volts complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-1 32 Amp, 3 pahse 415 Volts complete all as specified and directed
Supply and fixing in replacement of power contactor type ML-1 40 Amp, 3 pahse 415 Volts complete all as specified and directed
M&L in replacement of panel mounting single phase preventor relay, 3 phase, 415 volts complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 13 -21 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 20 -32 amp complete all as specified and directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 28-42 amp complete all as specified and as directed
S&F in replacement Timer (ST-100) switch complete all as specified and directed
S&F in replacement of panel mounted LED phase indication lamp (Red,yellow,Blue ,Green colour) operating voltage 220 to 240 volts suitable for fixing in the LT panel all as specified and as directed. Make L&T/AE/Simens or equivalent
S&F in repair ON / Off switch push type for motor starter panel complete
S&F in repair digital type voltage & amp meter 415 Volts, 3 Phase incl connection for LT panel complete.
Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of aluminium paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays etc all as specified and as directed.
Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of Synthetic enamel paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays etc all as specified and as directed.
Neptune Engineers and Builders
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .