Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC | ₹6.7 Cr | L1 | Accepted-AOC LOWEST BIDDER. |
| 2 | L2₹7.1 Cr+₹40.5 L (6.00%)Rejected-AOC | ₹7.1 Cr+₹40.5 L (6.00%) | L2 | Rejected-AOC NOT LOWEST BIDDER. |
| 3 | L3₹7.2 Cr+₹48.5 L (7.20%)Rejected-AOC | ₹7.2 Cr+₹48.5 L (7.20%) | L3 | Rejected-AOC NOT LOWEST BIDDER. |
| 4 | L4₹7.6 Cr+₹83.5 L (12.4%)Rejected-AOC | ₹7.6 Cr+₹83.5 L (12.4%) | L4 | Rejected-AOC NOT LOWEST BIDDER. |
| 5 | L5₹8.5 Cr+₹1.8 Cr (26.8%)Rejected-AOC | ₹8.5 Cr+₹1.8 Cr (26.8%) | L5 | Rejected-AOC NOT LOWEST BIDDER. |
Tender Value
₹6.0 Cr
EMD Value
₹6.3 L
Closing Date
24 Aug 2020, 6:00 pmClosed
CHIEF ENGINEER AF NAGPUR
HQ CHIEF ENGINEER AF, VAYUSENA NAGAR, NAGPUR 440007
PROVISION OF MD ACCN FOR DSC AT 24 ED under AGE(I) AF MANAURI
2020_MES_360080_2
CA NO.CE(AF)/NGP/MAN/ OF 2020-21 800123/E8
Open Tender
Civil Works
Lump-sum
540 days
AGE I AF MANAURI
Class A cat a i
8 documents required · 8 mandatory
₹3,000
AGE I AF MANAURI
₹6.3 L
Yes
4 Sept 2020
23 Jul 2020
26 Aug 2020
23 Jul 2020
24 Aug 2020
10 Aug 2020
24 Jul 2020 - 3 Aug 2020
Amount
Lumpsum price worked out by the contractor for “BUILDINGS AND STRUCTURES” as listed in Sch 'A' part I above/below the lumpsum price of Rs. 39,212,800.00 as inserted by MES for Sch ‘A’ part I on srl page No. 29.
Lumpsum price worked out by the contractor for “SITE CLEARANCE/ EARTHWORK” as listed in Sch '‘A” part II above/below the lumpsum price of Rs. 2,93,947.45 as inserted by MES for Sch ‘A’ part II on srl page No.30.
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Sch '‘A” part III above/below the lumpsum price of Rs. 4,50,997.60 as inserted by MES for Sch ‘A’ part III on srl page No.31(R).
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Sch '‘A” part IV above/below the lumpsum price of Rs. 2,13,397.30 as inserted by MES for Sch ‘A’ part IV on srl page No.32.
Lumpsum price worked out by the contractor for “ROAD/PATH/HARDSTANDING & CULVERT" as listed in Sch ‘A” part V representing above/below the lumpsum price of Rs. 5,52,635.83 inserted by MES for Sch ‘A’ Part V on srl page No.34.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY" as listed in Sch ‘A” part VI representing above/below the lumpsum price of Rs. 1,97,094.00 inserted by MES for Sch ‘A’ Part VI on srl page No.35
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY" as listed in Sch ‘A” part VII representing above/below the lumpsum price of Rs. 7,31,101.40 inserted by MES for Sch ‘A’ Part VII on srl page No.38(R)
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Sch ‘A” part VIII representing above / below the lumpsum price of Rs.1,89,526.93 as inserted by MES for Sch ‘A’ Part VIII on srl page No.40
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” part IX representing above / below the lumpsum price of Rs.11,67,545.53 as inserted by MES for Sch ‘A’ Part IX on srl page No.41
Lumpsum price worked out by the contractor for “SOLAR WATER HEATER” as listed in Sch ‘A” part X representing above / below the lumpsum price of Rs.1113968.80 as inserted by MES for Sch ‘A’ Part X on srl page No.42
SCH 'A' PART XI(MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Sch 'A' Part-II.
(A) INTERNAL ELECTRIFICATION
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC FRLS insulated sheathed copper stranded conductor cable run in and including concealed in wall/ceiling/floor.PVC conduit not less than 20 mm as per IS 9537 Part III with all fitings such as bends,tee,junction boxes,etc of suitable size including 1.5 sqmm PVC (FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes of thickness not less than1.6 with surface laminated sheet suitable for housing switches,sockets fan regulators etc complete all as specified and directed.
One light point controlled by one switch.
One light point controlled by two 2-way switch.
One fan (ceiling/exhaust) point controlled by one switch.
One bell/buzzer point controlled by one push button.
One 3 pin 5 Amp switch socket outlet point on independent board.
One 3 pin 5 Amp socket on same board.
All as per item No 1 hereinbefore but for socket outlet 3 pin 15 Amps on independent board with cable size of 2.5 sqmm and earth continuity conductor cable of size 2.5 sqmm complete all as specified and directed by Engg-in-Charge. Note item No. 1 & 2 :- (i) Necessary PVC rigid junction boxes for identifying junctions as required on site directed by Engg-in-charge for point wiring work with PVC dummy plates shall be deemed to included on the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductors. (iii) The wiring shall be done strictly by following proper colour code, using red, yellow & blue for phase, black for neutral and green for earth.
Supply and fixing surface & wall mounted LED fitting 4' (feet) long with extruded aluminium housing and robust construction 18W to 20W, system lumen (NOM) not less than 1800, complete with electronic driver, suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 KV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing surface & wall mounted LED fitting with extruded aluminium housing and robust construction 9/10W, system lumen (NOM) not less than 900, complete with electronic driver, suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 KV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing decorative wall bracket light fitting LED 10/12 watt made up of high grade engineering plastic material system lumens (NOM) not less than 900, suitable for 180 to 240volts AC inputs, colour Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing building security LED light 25W aesthetically designed IP65 protection complied to IEC 60598 and IS 10322, system lumen (NOM) not less than 2500, high power LED cool day white, with integral driver, pressure die cast aluminium body including reduced glare, impact resistance, polycarbonate cover complete with suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements like street light bracket made out of GI pipe 32mm dia medium grade, 2 sets of clamps nut bolts, washer etc complete with all accessories all as specified and directed
Supply and fix ceiling fan 1200 mm sweep single phase 230 V 50 Hz , white in colour copper wound including condensor, connector, canopy, down rod, clamps, etc complete with all acessories internally pre wired and including connecting up with flexible copper conductor cable of suitable size complete as per BEE standard 5 star rating ISI marked,all as specified and directed by Engg-in-charge, Make : Havells model no. XP-390 /CG Cat No. Empower 50 series/Bajaj cat no. 250803 .
S& F Metal exhaust fan 300 mm sweep with louvers, Trans Air 12'' grey complete with connection including making hole, plastering etc, making good with the existing wall for fixing of exhaust fan and all as specified and as directed by engineer-in-charge.Make: Crompton :BAJAJ cat no. 70001 /USHA Model No.TURBOLDEXHFANBBB-GGREY.
S& F exhaust fan 225 mm sweep with louvers Trans Air 9'' grey complete with connection including making hole, plastering etc, making good with the existing wall for fixing of exhaust fan and all as specified and as directed by engineer-in-charge.Make: BAJAJ cat no. 70001 /USHA Model No.TURBOLDEXHFANBBB-GGREY.
Supply, Installation, Testing & commissioning of indoor type, wall mounted (with bolt & nuts) meter cabinet as per manufacturing design but not less than of size 1.5 x 0.9 x0.2 m and made out of 2 mm thick CRCA MS sheet with double door having glass window for viewing KWH meter . All door should have neaprene rubber gasket and locking arrangements.The cabinet shall be painted both internally and externally with powder coated paint (shade RAL 7032 SIEMENS GREY). The cabinet shall be dust and vermin proof with degree of protection IP-52. The cabinet shall be comprising with the following accessories.
(a) Four pole MCCB, 200 Amps with breaking capacity of 16 KA having adjustable thermal and fixed magnetic release. (b) Aluminium bus-bars for 3 phase & neutral of current carrying capacity upto 200 Amps dully mounted on FRP/DMC insulators and necessary drilling for connectors and duly covered with heat shrinkable PVC sleeves of standard colour code. (c) KWH meter , 1 phase, 2 wire, accuracy class : 1.0, confirming with IS 13779, current carrying capacity 10-60 Amps, 240 volts, 50 Hz LCD display with backlight, sure resistant and tamper proof with magnetic shielding, indication for power on, Current reversal and reset backups suitable for optic port/ RS 232 port. (11 Nos) (L&T/HPL/Secure) (d) MCB SPN 32 Amps 10 KA- 11 Nos. (e) MCB SPN 10 Amps- 02 Nos (1 for security lights & staircase & 1 for spare) (f) Anolag type timer upto 16 Amps capacity single phase 230 volts for building security lights. (h) Internal wiring of meters/MCB/Cable connector shall be carried out with 10 sqmm copper condector unsheathed, multi stranded PVC insulated, 1100 volt grade single core cable of standard colour code for phase & neutral including necessary lugs/nuts/bolts washers etc. (j) LED phase indicating lamps (RYB) with control MCB (SP-2 Amps) - 3 Nos.
Supply, Installation, Testing & commissioning of indoor type, wall mounted (with bolt & nuts) meter cabinet as per manufacturing design but not less than of size 1.0 x 0.9 x 0.2 mtr and made out of 2 mm thick CRCA MS sheet with double door having glass window for viewing KWH meter. All door should have neaprene rubber gasket and locking arrangements.The cabinet shall be painted both internally and externally with powder coated paint (shade RAL 7032 SIEMENS GREY). The cabinet shall be dust and vermin proof with degree of protection IP-52. The cabinet shall be comprising with the following accessories.
(a) Four pole MCCB, 100 Amps with breaking capacity of 16 KA having adjustable thermal and fixed magnetic release. (b) Aluminium bus-bars for 3 phase & neutral of current carring capacity upto 200 Amps dully mounted on FRP/DMC insulators and necessary drilling for connectors and duly covered with heat shrinkable PVC sleeves of standard colour code. (c) Single phase KWH meter 2 wire, accuracy class : 1.0, confirmation with IS 13779, current carrying capacity 10-60 Amps, 240 volts, 50 Hz LCD display with backlight, sure resistant and tamper proof with magnetic shielding, indication for power on, Current reversal and reset backups suitable for optic port/ RS 232 port. (07 Nos) (L&T/HPL/Secure) (d) MCB SPN 32 Amps 10 KA- 07 Nos. (e) MCB SPN 10 Amps- 02 Nos (1 for security lights & staircase & 1 for spare) (f) Anolag type timer upto 16 Amps capacity single phase 230 volts for building security lights. (h) Internal wiring of meters/MCB/Cable connector shall be carried out with 10 sqmm copper condector unsheathed, multi stranded PVC insulated, 1100 volt grade single core cable of standard colour code for phase & neutral including necessary lugs/nuts/bolts washers etc. (j) LED phase indicating lamps (RYB) with control MCB (SP-2 Amps) - 3 Nos.
S & F MCB SPN 10 to 16 Amps breaking capacity 10 KA C series single phase 240 volts including making connection complete all as specified and directed by Engg-in-Charge. . Make ; Leagrand cat no. 408609 to 408617 / L & T cat No. AU10SS0163C to AU10SS0323C/
S & F MCB SP 6 to 10 Amps breaking capacity 10 ka B series single phase 240 volts including making connection complete all as specified and directed by Engg-in-Charge. Make : L&T Cat Part No AU10Q10063B to AU10Q10203B/ Legrand cat no 408587 to 408597 / Havells.Cat No. DHMGCSPF006-032.
Supply and Fix SMC Meter enclosure, single piece mounted without joints concealed metal hinges mounting screws fitted from inside metal hardware for wire seal, Adequate space for meter and cut-outs, Metal body, wide range for different applications, Lightweight, yet strong, weatherproof,, shockproof , free from pilferage, Maintenance-free of size 250x250x155 mm, with Single phase KWH meter 2 wire, Accuracy class : 1.0, confirmation with IS 13779, current carrying capacity 10-60 Amps, 240 volts , 50 Hz LCD display with backlight, sure resistant and tamper proof with magnetic shielding, for power on, current reversal and reset backups suitable for optical port/RS 232 port (07 Nos) (L&T/HPL/Secure).
S & F LED bulb adore 3 watt B22 CDL Lamp, Make : Havells Code No. LHLDERUEMD9X003/Bajaj/Wipro.
M & L for sub main wiring (concealed) complete for with Two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:-Same size wire shall be used for phase, neutral & earth conductors. (ii) The wiring shall be done strictly by following proper color code, using red, yellow & blue for phase, black for neutral and green for earth.
M&L for Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to galvanized earth lead 4 mm dia GI wire by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B2, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 5 of SSR Pt-I 1991 specification. Note :- (i) The excess requirement (if more than 7.5 Mtr) of copper strip and their joints for connecting upto the test point will be measured and paid separately) (ii) The excavation exceeds if any of the Ser Item No 1 above will be deemed to be included in the item rate.
(B) EXTERNAL WATER SUPPLY
M&L fitting for DI pipe in size up to 150 mm dia of bore conforming to IS 9523-2000 socket/spigot socketed pipe such as bends(any type radius and angle ) tapers any type (straight, bend increasing , decreasing or double socket etc.)T- pieces, single branch Y junction, double branch cross (all socket or socket and spigot)reducer n required length, collar cap and plug etc with cutting /welding/jointing/bolting etc.all site work and directed
supply, laid in trench , jointing and testing of ductile iron pipe in size 100 mm dia of bore with spigot and socket ends, centrifugally cast, class K-9 in any length conforming to IS 8329-2000 with required jointing and fittings material such as rubber packing, nut and bolts along with two nos. of washers etc minimum hydrostatic test pressures as per IS complete all as specified and directed. Note:- (i) Manufacturer and site test certificates shall be deposited by contractor for office record (ii) Quoted rate shall be included cost of route indicator fixed on 10 Mtr interval made by GI angle in size 40 X40 X 6 mm length 40 cm above ground level and 20 cm grouting in PCC foundation minimum, route marking on 6'' dia (inches) round plate welding on
Supply and fixing of cast iron sluice valve 100 mm bore heavy duty both ends flanged class PN-1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top ,nut, bolt, washer including 3 mm rubber gasket joint etc.complete all as specified and directed.
Supply and fixing of cast iron sluice valve 80 mm bore heavy duty both ends flanged class PN-1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top ,nut, bolt, washer including 3 mm rubber gasket joint etc.complete all as specified and directed.
M&L brick masonry valve pit chamber including necessary excavation earth work, one brick thick wall in CM 1:4 on 100 mm thick PCC 1:4:8 type D-2 (40 mm graded aggregate ) as n foundation and 15 mm thick rendering in cement mortar (1:4) internally ,externally up to 15 cm below GL providing valve pit cover made of 3 mm thick MS sheet/plate , welded with 40X40X6 mm angle iron frame fixed on top of valve pit by means of hold fast 150 mm on, embedded in PCC 1:2:4 type B-1 (20 mm graded aggregate) block of size 230x200x100 mm and provision of hinges ,handle and locking arrangement painting in two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer all as directed with internal dimensions as under:-
(a) 900x900x900 mm (internal dimension for sluice valve)
(b) 600x600x600 mm (internal dimension for gate valve)
(C) EXTERNAL ELECTRIC SUPPLY
Supply, Installation, Commissioning and testing of Transformer capacity 160KVA outdoor type 11/0.433KV step down 3 phase, 50Hz AC copper wound oil immersed, naturally air cooled external cooling tubes, off load tap changer on HT side to vary secondary voltage 4 Nos. with steps of 2.5% from +2.5% to (-) 5% and confirming to IS-1180(Part-I) 2014 level 3 / IS - 2026, ISI marked BEE star rated and for oil IS-335-1993 temperature rising 40 degree centigrade in winding & 35degree centigrade in oil when measured by the resistance method after continues full load run & at ambient temperature of 40 degree centigrade, comprising all as under:- Note: (i) Quoted rate shall be included cost of initially oil filling and RCC plinth foundation in standard size as per IS or IE rule (minimum 2.1 x 2.1 Mtrs in 1 Mtr height with stair step) complete.
(ii) Material & labour for cutting welding jointing to angle iron for making post and struts in fencing in given size for fencing to transformer/bracing cross arms support clamp back plates fabricated from structural steel section including nut bolts washer bending hot cold drilling holes etc all as site required in any shape incl painting in two coats using syenthetic enamelled paint over one coat of red oxide one as finishing complete all as directed. (a) One cable HT end box (Primary side) consisting of Three Nos porcelain / any other suitable makes by OEM bushings complete with nut & washers etc (b) One cable LT end box (Secondary side) consisting of Four Nos porcelain / any other suitable makes by OEM bushings complete with nut & washers, cable gland etc (c) Oil conservator with filter type. (d) Dehydrating breather with connecting pipe, first fill of dehydrating agent. (e) Thermometer pocket with thermometer dial size 100 mm dia. (f) Rating plate. (g) Terminal marking plates. (h) Oil level gauge. (j) Oil drains & filter valve. (k) Lifting lugs. (l) Four plain rollers. (m) Oil filter plug with connection complete. (n) Extra bushing for neutral out side the cable box for providing independent earthing. (o) Oil filling hole with cap. (p) first filling of oil.
M&L for Expulsion type drop out fuse unit suitable for installation in 50 Hz, 11kV distribution system, rated voltage shall be 12kV and rated current shall be 100 Amps, breaking capacity shall be 8kA(asymmetrical), the cut out shall be confirm to as per IS 9385(part-I to part-III)complete all as specified and directed.
Supply, fabrication, installation, connecting testing and commissioning of LT Panel outdoor cubical compartment type factory made (CPRI approved) manufacturer , of suitable compact size made out of CRCA sheet 3 mm thick for load bearing portion and 2 mm for compartment, both side open able locking arrangement double door TP and Half Neutral aluminium bus bar 400Amps rated equal size sleeve insulated in colour coding mounting on heat shrinkable insulator, CT in suitable rating for domestic load, confirming to related IS and IE instruction, totally enclosed dust, weather & vermin proof, powder coated shade No RAL 7032 after washed with RR-10 chemical for rust with iron angle of size 50x50x6 mm mounting on foundation minimum 45cm above the normal ground level with lifting hook and provision for making earth connection, internal connection shall be made using copper strip in proper rating complete with comprising as under:-
Note: - (i) Quoted rate shall be including brick/cement work for foundation. (ii) Drawing shall be approved by Deptt before placing the order. (TFR main LT Panel) (a) MCCB 4 pole 250 Amps 36 kA with adjustable thermal and magnetic releases-01 No (as Main incomer) (b) MCCB 4 pole 63 Amps 16 kA with adjustable thermal and magnetic releases 01 No. (c) MCB SPN40Amps, 10kA -02Nos (1+1Spare) (d) Three phase LED indicator in RYB colours with switch - 01 Set. (e) Digital Multi function meter in suitable rating for voltage up to 500 Volt, Current 250 Amps rating ISI mark - 01 No. (f) MCCB 4 pole 100 Amps, 16 kA with adjustable thermal and magnetic relay-(3+1as stand by).
Supply & Fix MCCB FP 250 Amps, 36kA having adjustable thermal and fix magnet duly enclosed in sheet metal enclosure made of 3mm thick front openable door having sufficient space for termination of LT UG cable size of 3.5 core 120sqmm duly fix on frame made out of angle iron of size 50x50x6mm at the height of 75cm above Ground Level and 30cm below GL grouted in PCC of type C1 (1:3:6) complete all as specified and directed.
Material and labour of cutting to path/road/drain/hard standing in specified depth for laying horizontally accorsing the light grade GI tube in size 80mm for mechanical protection to cable incl making good to disturbed surfaces matching with existing surface area complete all directed.
Supply fixing connecting of LED street light fitting 45 Watts with pressure die cast aluminium housing warm white luminaries confirming IP 65 protection including GI Pipe bracket made out by 25/40 mm dia 1.2 mtrs long bend in 120 degree fixed by GI strip clamp made by 40x6mm strip with nut bolt and washer complete all as specified and directed.
Supply and fix cable junction box 200 X160 X 98 mm in size made out of thermoplastic sheet having IP 65 protection for out door installation fixed with 4 way Bakelite cable terminals with one MCB SP 6 Amps to be fixed inside the box including 03 Nos polymide gland with check nut (M-32 - 3 Nos) fixed on pole with flat iron clamps of size 25 x 3 mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as directed by Engineer-in-charge . Make : Hensel Cat No. K 8250 / Sintex
M&L for earthing galvanised iron earth plate of size 600x600x6 mm thick buried directly in ground not less than 2.25 mtrs below normal ground level. Earth plate packed on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI earth strip of size 32x6 mm thick soldered and rivetted to earth plate. GIearth strip will be protected by using 50 mm bore light grade GI pipe earth plate to top edge and watering GI pipe 20 mm dia medium grade 2.5 mtr long with funnel wire mesh etc. necessary earth/brick and PCC work disposal of surplus soil to a distance not less than 50 mtr chamber of PCC (1:4:8) type D2 using 40 mm graded stone aggregate, coping shall be PCC (1:3:6) type C1 using 20 mm graded stone aggregate, RCC pit cover 50 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate, reinforced with 8 mm MS bar at 80 mm C/C both way in lieu of CI pit cover and angle iron frame, flame funnel wire mess testing on completion all as specified and shown in electrical plate No 3 of MES SSR part-1 2009 complete.(TFR-04, GOD-02, LT panel-02, Four pole Structure -02, Lightning Arrester-02)
(D) SEWAGE DISPOSAL
RCC Septic tank 100 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users with UPFLOW FILTER complete all as specified and directed.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 4.5 M effective depth complete all as specified and directed.
C RAMAIAH PROPRIETOR ENGINEERS GOVT CONTRACTORS CIVIL
MD BUILDER
B.K.ASSOCIATES
M/s NSA Engineering Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .