Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-2₹92.4 L+₹19.7 L (21.3%)Accepted-AOC | L-2 | Accepted-AOC Accept | |
| 2 | L-1₹92.4 LRejected-AOC | L-1 | Rejected-AOC Reject |
Tender Value
₹95 L
EMD Value
₹1 L
Closing Date
1 Jun 2024, 1:00 pmClosed
SE EDC-1 AGRA
B-690 Kamla Nagar Agra
For Strengthening the protection system of electrical infrastructure at various 33/11 KV S/s nd other assocaites works in Buisness Plan 2024-25 on Semi Turn Key Basis under EDC-1 Agra.
2024_DVVNL_923009_2
92/EDCA/2023-24
Open Tender
Electrical Works
Piece-work
90 days
B-690 Kamla Nagar Agra
As Per Tender Documents
2 documents required · 2 mandatory
₹3,000
DVVNL
₹1 L
16 Feb 2025
22 May 2024
1 Jun 2024
22 May 2024
1 Jun 2024
22 May 2024
Part-A (Supply of Material) 33 KV Isolator Alu. Lug/Clamp
Battery Charger Standard Make
battery Stand holding Clamp Standard Make
Battery Charger with Battery Set Standard make
33 KV CT Connectinhg Clamp
11 KV VCB CT 600/300/5 Amp Standard Make
Fire Extingisher with Stand
11 KV Jointing Kit outdoor 3x300 sqmm Standard Make
11 KV Vaccum Interputer Standard Make
11 KV Spout
33 KV Line Breaker
Silica Gel
Megar mechanical Type 500 V of Reputed Make
Breather for 5/8/10 MVA power T/F Standard Make
Fuse Wire 8/14/16 SWG
Crimping Tool Standard Make
Battery Cell 2 V Standard Make Standard Make
Buccoz relay for 5/8/10 MVA Powre T/F Standard Make
Part-B (Erection work) Cartiage of 11 KV 3x300 sqmm XLPE Cable, Control Cable 2x2.5, 4x2.5 & 6x2.5 sqmm & service cable for VCB & Control Panel from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of 33 KV CT 200/100/1-1A, 33 KV CT 400/200/1-1A & 33 KV CT 600/100/1-1A & from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of 33 KV PT & 11 KV PT, Steel structure for PT from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of 33 KV VCB 800 Amp. from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of 33 KV VCB 1250 Amp. from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of 11 KV VCB I/C 200/100/5 & 11 KV VCB O/G 200/100/5 from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of Fresh Oil for Power T/F from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of Oil Seal for Power T/F from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70Kms.)
Cartiage of Line Material from Store Center Agra to work of site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-70Kms.) Line material viz. Aerial bunch conductor/Weasal conductor/Dog/ Rabbit, G.I. earth wire, cross arm, angle, channel, insulators, Arrestor, clamps, Dist. Box, and other required material, if required in Estimate/Package.
Bore Earthing of 5 MVA & 10 MVA Power T/F and control panel by digging machine depth of 250 ft. below as per RESPO Norms.
for the work of Chemical Earthing for 33 KV Breakers with all structure as per RESPO Manual.(All material provided by the contractor at his own cost)
for the work of Chemical Earthing for 11 KV VCB as per RESPO Manual.(All material provided by the contractor at his own cost)
For the work of making Plinth Foundation for 33 KV VCB as per Site requirment and RESPO NOrms (All material provided by the contractor at his own cost)
Earthing of 5/8/10 MVA Power transformer by maintenance free Earthing Electrods (Chemical) by digging pits 6" dia upto 3mtr. deep including inserting pipe in pipe technology concept involve two mild steel pipes one inserted inside. One inserted inside the other of size- 1- Inner pipe dia 50mm. 2- Outer pipe dia 100mm and length of the both pipe shall be 3000 mm. The M.S.pipe shall be ISI mark of class B as per IS 1239. Thickness of the pipe shall be 12 SWG. The empty space in the pipe shall be filled with the specially developed crystalline material conductive mixture such as copper and aluminimum powder, conductive carbon and bonding material etc. mixed in diffrent proportions. Conductive mixture contents shall be 70 % carbon powder & 30% metal powder preferably pure copper or aluminum material along with the required quantity of bonding materials. Granule size of the carbon & metal powder shall be 100 mesh. The mixture if forced (pressurized) inside the earth electrode in empty space of inner pipe & in empty space between the inner & outer pipe of the earth electrode, in paste form and after solidification of the same the bottom end cap as well as top end cap is provided. The mixture shall be pressed by machine in the pipe. Precaution shall be taken so as no air gap inside the pipe while pressing. The back fill compound (earth enhancment material ) shall be superior conductive material that improves earthing effectiveness especially in areas of poor conductivity such as rocky ground, sandy soil & areas of moisture varation. It may contain conductive cement (20%) graphite carbon powder(50%), hydrous aluminum siliacate (10%), Sodium montmorillonite (20%) etc. it shall be placed around earth electrode in the earth pit to improve the conductive of earth electrode & ground contact area. Mild steel electro galavanized Flat 50x6 mm shall welded to earth electrode pips & connected with Trasnformer netural / body as below with the hlep of steel nut & bolt or through welding as per site requirment to 80mm GI pipe and filling of chemical mixutre around the GI pipe upto 3 mtr. including making of chamber & connecting the top of the inserted pipe and transformer body / neutral through M.S.flat 50x6mm with the help of nut & bolt or through welding and making a main hole of size 2'×2' and covering the same by a stone pad for the purpose of poring water for moisture. Body Earthing of Transformers, Neutral Earthing of Transformers.
Fixing of earthing rod as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
Filling of 11 KV 3x300 sqmm outdoor Jointing Kit and making connection as per direction of supervising engineer.
Installlation & Commissioning of 33 KV CT & 400/200/1-1A complete work as per RESPO Manual.
Installlation & Commissioning of 33 KV CT 200/100/1-1A complete work as per RESPO Manual.
Installlation & Commissioning of 33 KV CT & 600/200/1-1A complete work as per RESPO Manual.
Installlation & Commissioning of 33 KV P.T. with steel structure complete work as per RESPO Manual.
Installlation & Commissioning 11 KV CTR 600/300/5 Amp complete work as per RESPO Manual.
Installation of 33 KV VCB 800 Amp & 1250 Amp in proper alignment and direction and jointing of earthing strips with help of gas welding and making cable connection including shifting dragging with all other associated works.
INSTALLATION OF 33 KV BUS ISOLATOR :- Assembling and installation of bus isolator on the isolator structure Adjusting of operating machanism in proper alignment so as to ensure smooth operation of the same in case of line isolator proper operating of earth links shall be ensured. The work includes fabrication for proper fixing if required.
INSTALLATION OF 33 KV LIGHTENING ARRESTORS :- Assembling and installation / mounting of lightening arrestors on the L.A structure / Terminal Gentry complete with making earth connection (seprate) and line connection . The work includes providing & fabrication of 3 Nos. M.S Plates of size 300×450mm, 10 mm thick for placing lightening arrestors.
INSTALLATION OF 33 KV POST INSULATORS. Installation of post insulator on the structure. The work also includes providing & fabrication of 3 Nos. M.S Plate of size 300×450mm. 10 mm. thick for placing post insulator.
Centrifusing and filteration of 5/8/10 MVA Power T/F at destination S/S including testing of T/F oil to give BDV value not less than 60 KV when tested with 2.5 mm gap electrode. including opening of radiators, conservator tank & other accessories as required and drain out T/F oil in drums & unloading at destination place & fitting of radiator, conservator tank & other accessories and filling of T/F oil safely. & all T&P, crane, Trolla etc as required is to be arranged by the contractor at his own cost.
Fixing of 33 KV Control Panel for Single T/F as per RESPO Manual.
Fixing of 33 KV Control Panel for Double T/F as per RESPO Manual.
Installation & Energization of Battery set & Charger of Standard make and as per RESPO Norms
Laying of control cable 2x2.5 sqmm as per site requirment and RESPO Norms.
Laying of control cable 4x2.5 sqmm as per site requirment and RESPO Norms.
Laying of control cable 6x2.5 sqmm as per site requirment and RESPO Norms.
Laying of Service Cable for VCB and Control Panel as per site requirment and RESPO Norms.
Laying of 11 KV 3x300 sqmm XLPE cable in trench with making loop (at a distance of approx. 4 mtr.) laying of bricks (18 nos. in one meter), filling of sand in trench then laying earth and its levelling and rammuring etc., complete work as RESSPO norms.
Fixing of 33 KV Remote Operating System Control Panel for Single T/F as per RESPO Manual.
Fixing of 33 KV Remote Operating System Control Panel for Double T/F as per RESPO Manual.
For the work of Stopping oil Leakage of Power T/Fs :- Opening/disassembling of Power T/F all 11 KV and 33 KV jumpers/cables of the said converters, removing the top cover by opening the nutbolts of the top cover with the help of a crane, opening the conservator tanks of the power converters and separating them from the converters, oil of the power converters as required. Removing the level and carefully filling it in the drums, changing the cork sheets of the tanks, changing the packing (rubber) of 11 KV and 33 KV bushings, changing the packing of oil tanks and changing the packing of radiator bulbs, faulty HT and LT roads of the transformers. Replacement of damaged HT bushings and LT bushings of converters, replacement of worksheet and packing of converters, reinstalling top plate, radiator and conservative tank etc. in proper place efficiently, carefully pouring oil back into the tanks of converters and closing them tightly again. Cleaning of 11 KV and 33 KV bushings, reconnection of all 11 KV and 33 KV jumpers/cables of transformers after completing the above work, etc.
General overhauling/Refitting of operating Mechanism of circuit breaker /associated Equipement as required (tripping leaver, charging leaver, inter lock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop, set screw, spindle, lock nut, Trip roller coil assembly release roller, ratechet, coil pot, main toggle, Tripping plunger, operating springs, Trip Coils etc)
Removal and Cartiage of old & Used Material (33 VCB- 02, Scrap Iron-200 KG & Isolator scrap-60KG). (Apprx 00-70 KM)
Gowri Associates (BID ID -4352250)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .