Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹16.5 L+₹2.1 L (14.2%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹16.8 L+₹2.4 L (16.4%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹17.0 L+₹2.6 L (17.9%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹17.4 L+₹3.0 L (20.7%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
25 Mar 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
PROVISION OF TILING IN SF MD ACCN (10 DUS) AT ANUJ VIHAR PROVISION OF WATER TANKS IN ORs LIVING ACCN IN IHQ ARMY CAMP AND PROVISION OF FALSE CEILING IN DINNING HALL OF ORI AT IHQ OF MoD (ARMY) CAMP UNDER AGE B/R-1 (S) OF GE (SOUTH) DELHI CANTT-10
2021_MES_426118_1
GE/DS-81/2020-21
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹36,000
Yes
3 May 2021
26 Feb 2021
27 Mar 2021
26 Feb 2021
25 Mar 2021
11 Mar 2021
27 Feb 2021 - 10 Mar 2021
Amount
M&L for roughning sufaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc brushing neat cement slury @ 3Kg of cement per Sqm complete all as specified and directed by Engineer-in-charge.
M&L for Screed bed or bedding layer of cement mortar 20 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-charge.
M&L for 10 mm thick rendering on wall in (cement mortar 1:4 )on fair faces of brick work or concrete surfaces complete all as specified and directed by Engineer-in-charge.
M&L for vitrified double charge ceramic tiles 10mm thick (square/ rectangular) policed area of each tiles exc 0.42 Sqm and n.exc 1.00 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement grout to match complete all as specified and directed by Engineer-in-charge.
All same as per item No 5 here in before but as in skirting
Taking down shutter of any description exc 1 Sqm and n. exc 2 Sqm ( refixing in same opening ) after cutting the bottom rail at requiared size complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing treatment , washing down and stopping of distempered and painted surfaces and old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing treatment , washing down and stopping of distempered and painted surfaces and old plastered surfaces of ceiling and applying two coats of distemper oil emulsion, white or tinted over complete all as specified and directed by Engineer-in-charge.
M&L for preparing of old painted surfaces of wood or wood based materials of any description over 10 cm width or girth and applying on coat of synethic enamel paint on wooden surfaces complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polythene water storage tanks of capacity 5000 ltrs (cylindrical / vertical with closed top) white ,triple layer construction, ISI marked , hoisted & fixed in position complete all as specified and directed by Engineer-in-charge. . Make:- Sintex/ Rotex/ Polywell
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
S&F 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (minimum weight 142gms) complete all as specified and directed by Engineer-in-charge. Make :- Prayag/ Polytuff
S&F galvanised iron tank nipple 15mm bore suitable for HDPE water tank complete all as specified and directed by Engineer-in-charge. (Make- Unik or equivalent as approved by GE.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in (Cement mortar 1:4) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in coping and benching etc including necessary form work complete all as specified and directed by Engineer-in-charge.
Providing & fixing false ceiling with semi perforated 12 mm thick micro tegular edged at all heights with GRG (glass fiber reinforced Gypsum ) false ceiling tiles of size 595/X595 of approved texture design and patter having moisture contain less than 2%, humidity resistance of 99%, NCR 0.50 to 0.75 as per IS 8225, 1987, non combustible as per BS 475 ( Part -IV1970 and light code description unit rate No 429 SUB HEAD 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85 % minimum to laid in true horizontal level suspended on interlocking metal T grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanized @ 120 gms per sqm including both side comprising of main T runner of size 15X 32 mm of length of 3000 mm , cross T of size 15 X 32 mm of length 1200 mm and secondary intermediate crass T of size 15 X 32 of length of 600 mm to form grid module of size 600 X 600 mm suspended from ceiling using galvanized metal sheet item (galvanized @ 80 per sqm ie 50 mm long 8 mm outer dia meter M-6 , fasteners , 6 mm dia fully threaded hanger rod up to 1000 mm length and L shape level adjusters of size 85 X 25 galvanized iron perimeter wall angle of size 24 X24 X 0.40 mm of length 3000 mm to be fixed on perimeter of wall / partition with the help of plastic rawl pluhs at 450 mm centre to centre and 40 mm long dry wall screw . The work shall be carried out as per specification drg and as per direction of Engr-in-Charge. Make : - Diamond Ceiling/ Gypcore/ Maruti Gypsum/ Shera.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Vipul Construction
M/S.M.S.Devi.Const.Co
verma enterprises
Som Nath Kakkar
SABHARWAL CONSTRUCTION CO.
ramveer Singh
M/S GOPAL JEE SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .