Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.3 L+₹2.7 L (8.45%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | L2 | Rejected-Finance not lowest | |
| 3 | L3₹42.0 L+₹10.4 L (32.9%)Rejected-Finance | L3 | Rejected-Finance not lowest | |
| 4 | L4₹44.9 L+₹13.3 L (42.2%)Rejected-Finance | L4 | Rejected-Finance not lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
31 Dec 2019, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINT OF DISTRIBUTION/ POWER TRANSFORMER, LT/HT UG CABLES/OH LINES, REPAIRS TO HT/LT SWITCHGEAR, CAPACITOR BANKS, AT DMRL, DLRL AND CONNECTED AREA, KANCHANBAGH, HYDERABAD
2019_MES_303372_1
GE I KBAGH TOKEN 72 OF 2019 2020
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
16 Jan 2020
3 Dec 2019
6 Jan 2020
3 Dec 2019
31 Dec 2019
17 Dec 2019
3 Dec 2019 - 10 Dec 2019
Amount
Disconnection of all Primery/Secondary connection of the defective transformer up to 625 KVA capacity and 11/ 0.433 KV out door / indoor any make taking down / out from plinth / pole / platform with the help of crane and transporting the same carefully to workshop for repair and bringing back and install, with all connections as directed, after repair in its existing position, including testing and commissioning, complete all as directed.
M&L for Making Primery/Secondary coil with insulating copper wire of required gauge, craft paper, cotton tape, HT/LT insulation as per specification of old transformer including making of coil as required for various capacity of transformer complete all as directed.
S&F in repairs of HT bushing including metal parts and washer complete for any make of plinth/pole mounted transformer upto 625 KVA capacity complete all as directed..
S&F in repairs LT rod / studs for up to 625 KVA transformer made of brass with nut and washers, Insulator and fittings etc as per size and shape of original complete all as directed.
S&F in repairs Gasket set for upto 625 KVA, for top of transformer or conservator tank after decanning upto required level of oil complete all as directed.
S&F in repairs air breather any type up to 625 KVA transformer complete with filled silica gel complete all as directed.
Supply and filling of transformer oil in transformer mounted on plinth/pole including testing complete all as directed. Make:- SERVO / POWER OIL
Dehydration including filtration cleaning of transformer oil in transformer indoor / outdoor type at different locations of DRDO Township, DMRL, DLRL, DSC and ANURAG area by centrifusion machine having minimum capacity 1000 to 30000 ltrs / hr including testing oil before and after dehydration for each complete all as directed.
S&F in repairs Silica gel complete all as directed.
Opening of the 11 KV / 0.433 KV transformer up to 625 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of leaked cork seal with insulator or LT/HT bush (which is unserviceable) complete from the shell and making connections again of LT/HT bush to avoid leakage of oil refilling back to existing oil into the transformer, complete testing & commissioning complete all as directed. Note : HT/LT bush will be measured and paid separately under relevant item and cork seal with insulator is deemed to be included in quoted rate.
M&L for opening the top of Transformer upto 625 KVA for renewal of jumper (with brazing or welding) with new copper wire of existing size after removal of burnt out jumpering including decanning of oil upto required level for completing the work and testing the tranformer after completing the work, all as directed.
M&L for cable end termination, heat shrinkable, outdoor type, suitable for 3 core 120 to 185 Sqmm HT, 11 KV cable with necessary lugs complete all as directed.. Make :- REYCHEM/ DENSON/ MSEAL
M&L for cable end termination, heat shrinkable, outdoor type, suitable for 3 core 240 to 300 Sqmm HT, 11 KV cable with necessary lugs complete all as directed.. Make :- REYCHEM/ DENSON/ MSEAL
M&L for Cable jointing kit for 1.1 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as directed.
M&L for Cable jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as directed.
M&L for Cable jointing kit for 1.1 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm complete all as directed.
M&L for Cable jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete all as directed. Make for Srl item Nos 12 to 19 :- REYCHEM/ DENSON/3M
Replacement of Jumpers 11 KV of any size after removing unserviceable insulation and providing new insulation tape/pipe of required length and colour, lugs, nuts and bolts and connecting complete all as directed.
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 100Amps 8 way with necessary connecting arrangement like clamp, angle iron, nut and bolts complete all as directed
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 200Amps 6 way with necessary connecting arrangement like clamp, angle iron, nut and bolts complete all as directed
Cutting and trimming of trees, branches of any girth and any size touching to overhead lines and clearing 1.5 mtr length on both side of OH line with in a span 7mtrs each, disposing the same to a distance exc 50 m and n.exc 250 m for clearing the site complete all as directed. Note: Charges for safety measures deemed tobe included and proper power shut down to be taken while carrying out the work
Servicing of 11 KV AB switches upto 400Amps by dismantling & overhauling and re-assembling, testing & commissioning complete all as directed. Note: Cost of washer's and bolts required for replacement is deemed to be included in the quoted rate and Male/female contacts shall be measured and paid separately under relevant items.
Supply only Male contacts suitable for 11 KV Air Break switch complete all as directed..
Supply only Female contacts suitable for 11 KV Air Break switch complete all as directed..
S&F MCCB 100 Amps, 16 KA, 4 pole, 415 volts, 50 HZ alongwith MCCB enclosure including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections complete all as directed.. Make : HAVELLS / L&T /Schnieder And The above item shall be executed immediately as emergency task on as and when required basis.
S&F MCCB 250 Amps, 35 KA, 4 pole, 415 volts, 50 HZ alongwith MCCB enclosure including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections complete all as directed.. Make : HAVELLS / L&T /Schneider and the above item shall be executed immediately as emergency task as and when required basis.
Supply&Fixing basic all purpose surface and wall mounted 4', 18 W LED batten with polycarbonate housing & integrated electronic driver along with necessary connections, copper cable complete all as directed.. Make: Havells cat no. LHEXBQP7IN1W018 or eqlt in CG/PHILIPS
Supply&Fixing basic all purpose surface and wall mounted 2',9w LED batten with polycarbonate housing & integrated electronic driver along with necessary connections,copper cable complete all as directed. Make: Havells cat no. LHEXBQP5IN1W009 or eqlt in CG/PHILIPS
M&L for spray painting of capacity 100 KVA transformer pole mounted / plinth mounted at site and applying two coat of synthetic enameled Smoke grey shade paint after removing all dust,paint scales & rust paint shall confirm to IS 2032 including marking of transformer capacity with stencil letter with black or white paint and Font and Size of letter shall be directed by Engr-in-Charge, complete all as directed. Note: For ourtdoor transformer, 3 coats of white wash to plinth is deemed to be include in the quoted rate.
All as per srl item No.31 here-in-before but for 160-200KVA capacity transformer
All as per srl item No.31 here-in-before but for 250- 400KVA capacity transformer
All as per srl item No.31 here-in-before but for 500KVA capacity transformer
All as per srl item No.31 here-in-before but for 500-1000 KVA capacity transfomer
S&F in repair electronic ballast suitable for 1x36/40W FTL complete all as directed. Make: CG/BAJAJ/WIPRO
S&F in repair Fluorescent tube (T-8) 4 feet length,36/40w complete all as directed. Make:CG/Wipro/Surya
Supply and fixing of bollard light on ground including necessary incoming and outgoing cable connections, excavation, earth work and necessary PCC work for foundation with provision of suitable size of nut bolts complete all as directed.. Make:Havells Cat No.CORALPT35LED757PSYMTOPC or Techno Commercialiy equivalent in Philips/CG.
Supply and fixing of post top light pole mounted including necessary incoming and ougoing cable connections, excavation, earth work and PCC work for foundation with provision of suitable size of nuts & bolts complete all as directed. Make: Havells Cat No.CONEBL8WLED757PSYMTOPC or Techno Commercially equivalent in Philips/CG.
S&F 3 phase, DOL starter up to 7.5HP capacity with sheet steel Enclosure connecting and testing including taking down existing unserviceable DOL starter with enclosure complete all as directed.. Model MK1 cat No SS96254 of L&T
S&F in repairs Chiller Sensor suitable for upto 35 TR capacity Chiller unit. Make: Voltas / Blue star or Techno Commercially equivalent approved by GE.
S&F in repairs Chiller Sensor suitable for above 35 TR capacity and upto 55 TR Chiller unit. Make: Voltas / Blue star or Techno Commercially equivalent approved by GE.
S&F in repairs Chiller Sensor suitable for above 55 TR capacity and upto 110 TR Chiller unit. Make:Voltas / Blue star or Techno Commercially equivalent approved by GE.
S&F including testing and commissining for Scroll type Compressor unit suitable for 15 TR Package type plant, thermally protected, Max.system test pressure low/high side : 25 bar(g) / 31.9 bar (g), Maximum differential test pressure : 24 bar, 3 Phase,with working voltage of 380-400V, 50 Hz complete with all necessary fittings, including dismantling existing unserviceable compressor and Seperate from existing refrigerant & Electrical line, including brazing, leak testing cable connections with lugs complete all as directed. Make : Danfoss.
Opening the compressor of Voltas make 5H 40 model Dx type from its installed position by arranging dummy plates to suction and discharge lines, dismantling and removing of all internal parts, cleaning, overhauling and replacing worn out nuts, bolts, washers, springs, gaskets, shaft seal, ‘O’ rings etc., reassembling back all the internal parts, removing of dummy plates, oil charging, pressure testing, charging gas, testing and commissioning complete all as directed.. Note :- Replacement of spares, Oil & Gas shall be measured and paid separately under the relevant items of this schedule.
Remetalling/ grinding of crank shaft of Voltas make 5H 40 model Dx type compressor on the lathe including polishing and re-fixing back of compressor complete all as directed.
Supply only Shaft seal assembly of Voltas make 5H 40 Model Dx type compressor including system pumping down complete all as directed..
Supply only of main bearing pump end of Voltas make 5H 40 model Dx type compressor complete all as directed..
Supply only following items suitable for Voltas 5H 40 Dx type compressor complete all as directed. Make: OEM
Piston assembly.
Connecting rod assembly.
Suction reed set (Set of 02 Nos).
Discharge reed set (Set of 02 Nos).
Oil ring set (Set of 2 Nos).
Oil pump gear wheel set (Set of 02 Nos).
Cylinder liner.
Set of piston pins.
Compression ring set (Set of 2 Nos).
Half Section Bearing ( Set of 02)
Draining out the old compressor oil from various compressors and supplying, filling/ top up of compressor oil complete all as directed. Make: FREEZOL 68/ FREEZOL F-57
Replacement of the burnt out unserviceble loading, unloading coil of Voltas 5 H 40 model compressor and testing for proper functioning complete all as directed. Make :- ACCEL/VOLTAS.
Supply, erect, Testing & Commissioning of numerical directional Over Current & Earth fault relay Model Micom P111, complete control wiring with material, Programming/setting/calibration including software of relays required and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay. Make- Schneider or Techno Commercially equivalent ABB/L&T/Semiens
Supply, erect, Testing & Commissioning of numerical directional Over Current & Earth fault relay Model Micom P123, complete control wiring with material, Programming/setting/calibration including software of relays required and necessary addition/alternation of panel alongwith dismantling of old unserviceable relay complete all as directed Make- Schneider or Techno Commercially equivalent ABB/L&T/Semiens
S&F LED 2'x2' type recess mounted luminaire 24 Watt, Lumen Output -6500 lm , with Drive, connector block, complete with all accessories internally pre-wired including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting and connecting testing complete fixed on false ceiling complete all as directed Make:- Phillips/ CG /Wipro
S&F LED Street light fitting with IP66 type protection, 90W, CCT (K) not less than 5700, 50 Hz and housing epoxy powder coated die casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounting suitable for 40-60mm outer dia of pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as directed. Make:- Phillips/ CG /Wipro
Supply & Fixing LED fitting.indoor type 35W (4'), 230v Energy efficient, Recess/ Surface mounted, with Drive, connecter block. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as directed. Make:- Phillips/ CG /Wipro
S&F Garden light fitting with Pressure die-cast powder coated housing with PC diffuser, efficient high output, COB LED for Garden, Pathway etc. lighting.IP 66 protection and all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed Make- Crompton /Philips/wipro
S&F in repairs Power Contactor A95-30 complete all as directed. Make - ABB/C&S
S&F in repairs 3 phase, ML 1.5F Fully automatic Star Delta up to 12.5HP capacity with sheet steel Enclosure connecting and testing complete all as directed. Make- L&T/ABB/C&S
S&F for cable end termination, heat shrinkable, outdoor type, suitable for 3 core x 50 to 95 Sqmm HT, 11 KV cable with necessary lugs complete all as directed. Make :- REYCHEM/ DENSON/ MSEAL
S&F for HT 11 KV, Air Break Switch,Gang operated,Triple pole, mechanically operated, mounted on insulator and steel frame ,with oprating mechanism worked from ground level suitable for 11KV supply and current rating upto 400Amps. Make :- JAIPURIA/ VIDHUT
S&F 11 KV Grade, Lightning arresters expulsion type complete (Set of Three) with all fittings, transmission class,11000 Volts discharge capacity 65KA complete all as directed..
M&L in repairs for renewal of earth chambers of PCC 1:3:6 type C1 and 40 mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT Bars at 140 mm c/c both ways including replacement funnel with mesh and takingout unserviceable earth chamber complete all as specified and directed.
M&L for A/C Plant inspection and fault rectification carried out by OEM for releasing out locking other major problem & faults (faults either software problem or hard ware) including providing new software if software not working properly with all necessary tools and machines. Note :- Transportation & loading / unloading charges including chargers for hiring of machines and equipments are deemed to be included in quoted rates.
Supply & filling of refrigerant gas R-22 upto required level complete all as specified and directed. Make- MAFRON/FREON
Inspection of defective cable laid in various locations of DMRL, DLRL, DRDO Township and Anurag to locate the fault using cable fault Locator machine complete all as directed.
Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phase and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 4 Pole 125 Amps 25KA -03 No. (as Outgoing) (c) MCCB 4 Pole 100 Amps 16KA -03 Nos (connected-02 & Spare-01) (as Outgoing) Make of MCCB:- C&S/Havells
Material and Labour for maintenance free ring earth with four Nos single earth pits each pit consisting of two Nos copper coated steel rods of size 17mm dia joined with compression couplers (Total length 360cm long after joining), filled all around with 10 Kgs of earth enhancing compound, 25 Kgs of backfill compound, interconnecting the pits with 25mm x 3mm copper strip/ tape with exothermic welding and connecting up to the ring with 50 Sqmm single core multistranded PVC insulated copper wire (7 Mtr) upto equipment room and terminating the wire/ strip with 25 mm x 6mm, 300 mm long copper Busbar fixed on wall with insualtor support. Note : (i) The ring main earth resistantce shall be 0.5 Ohms , (ii) Rate Deemed to be inclusive of one PCC inspection pit of size 30cm x 30cm x 30cm depth and RCC cover placed on main pit.
S&F submersible Pump Controller MU-G10 DOL Starter suitable for submersible pump of capacity 7-5 to 10 HP, in sheet Enclosure type MU-G and replacement of existing old & rusted angle iron frme with new angle iron frame pedestal, type made out of 2mm thick MS Sheet with 50 x 50 x 6mm thick angle - 02 nos Legs, duly embedded in ground with PCC cubes and other end welded to panel board including taking down unserviceable starter complete all as directed . Make :- L&T Model : SS95983
S&F submersible Pump Controller MUG-G15 Fully Automatic Star-Delta Starter suitable for submersible pump of capacity 12.5 HP to 15 HP, in sheet Enclosure type MU-G15 and replacement of existing old & rusted angle iron frme with new angle iron frame, pedestal type made out of 2mm thick MS Sheet with 50 x 50 x 6mm thick angle - 02 nos Legs, duly embedded in ground with PCC cubes and other end welded to panel board including taking down unserviceable starter complete all as directed. Make :- L&T Model : CS94091
M&L for Inspection and servicing of OLTC of transformer of capacity 1.5 MVA and checking the electrical/manual operation of tap changer mechanism, check the integrity of the active components /contact surface mating for all tap positions, voltage ratio test for all tap position etc., including cleaning of the OLTC complete all as directed. Note : The Contrator shall be responsible for correct servicing of the OLTC and servicing to be done through OEM of OLTC.
Supply and filing the Refrigerant Gas R- 134A complete all as directed.
Evacuation of gas from 30TR package/ Central type System and leak testing the system by giving the dry nitrogen by separating the low side /high side of the system and arresting the leaks including replacement of Teflon seating of the all refrigerant line, suction/discharge valves of compressor, gland package of all angle valves flaring off and charging complete all as directed.. Note :- Gas shall be measured and paid separately under relevant items of this schedule
S&F in repairs liquid line filter dryer suitable for up to 35 TR capacity Compressor unit complete all as directed .
S&f including testing and commissining for scroll type compressor unit suitable for 12 TR package type plant, compatiable to R-22/R-134a refrigerent, thermally protected, Max system test pressure low/high side: 25 bar(g)/31.9 bar (g), Maximum differential test pressure : 28 bar, 3 phase, with working voltage of 460-400V+10%, 50 Hz, full laod amp 35A, nomial flow rate : 43.4 m3h, RPM : 2900 tr/Min complete with all necessary fittings, including dismantling existing unserviceable compressor and seperate from existing refrigerant & electrical line, including brazing, leak testing, cable connections with lugs complete all as directed Make: Model CSHA150K of Trane Make or equivalent in Denfoss/Indfoss
M/S GDR CONSTRUCTIONS
vvcenterprises
Shreshta Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .