Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-Finance MALANGPORA MALANGPORA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-Finance Accepted being L1 bidder. | |
| 2 | L2₹16.9 L+₹2.5 L (17.2%)Rejected-Finance | L2 | Rejected-Finance Rejected being othan than L1 bidder. | |
| 3 | L3₹17.2 L+₹2.8 L (19.7%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance Rejected being othan than L1 bidder. | |
| 4 | L4₹18.0 L+₹3.6 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being othan than L1 bidder. |
| Sl No | Description | Qty | Unit | M/S BASHIR AHMAD AND SONS L3 | MS Ghulam Hassan and Sons L2 | M/S ABBAS M. ENTERPRISES L4 | BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Cleaning and make it functioning sewage system by removing of all types of blockages from soil waste/rain water pipes, CI waste pipes, blockages of Toilets/bathrooms/WHB of bldgs upto G+2 storey height or in trenches, sewage line of any dia including junction of manholes of any description, man holes and septic tanks of any size and depth upto the last manhole to septic tanks of central sewage system to keep smooth functioning without any blockage of any description and in any situation with manually or some mechanically processes for all locations under GE (AF) Awantipur all as specified , by providing one safaiwala per day including all necessary tools and plants like bamboos, iron rod, bucket, rope, ladder etc .Contractor or rep of contractor has to attend sub-division on a daily basis to collect the complaints. complaints should be resolve within 24 Hrs without fail. | 11 | Per Month | 20,000 ₹2,20,000 | 700 ₹7,700 Lowest | 13,500 ₹1,48,500 | 8,000 ₹88,000 |
| 2.00 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft/loose soil, complete all as specified and as directed. | 40 | Cum | 100 ₹4,000 | 150 ₹6,000 | 100 ₹4,000 | 40 ₹1,600 Lowest |
| 3.00 | All as per item no 02 here in above but exceeding 1.5 deep and not exceeding 3m deep complete all as specified an directed. | 2 | Cum | 150 ₹300 | 140 ₹280 | 110 ₹220 | 40 ₹80 Lowest |
| 4.00 | Demolition of cement concrete (unreinforced) as in bed to drain pipes of any description and in any position, complete all as specified and as directed.
Note :- Demolition of of SGSW pipes of any dia shall be included in this items and shall be measured as solid. | 12.07 | Cum | 50 ₹603.75 Lowest | 200 ₹2,415 | 250 ₹3,018.75 | 170 ₹2,052.75 |
| 5.00 | M&L for Concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in plain cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed. | 150 | RM | 50 ₹7,500 Lowest | 200 ₹30,000 | 200 ₹30,000 | 90 ₹13,500 |
| 6.00 | M&L for Concrete bed to 200mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in Plain cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed. | 80 | RM | 50 ₹4,000 Lowest | 230 ₹18,400 | 400 ₹32,000 | 170 ₹13,600 |
| 7.00 | Supply and fixing for double wall corrugated HDPE non pressure pipe suitable for sewage/ waste etc of size DN/ID 150mm, dim 195mm and wall thick e4 min-1.5mm and e5 min-1.00mm all as per IS16098 (part-2), including jointing rings and necessary machinery to joint the sewers in-situ in trenches, including preparation of internal surface complete all as specified and directed .
Note:- Excavation and earth work including return filling shall be measured and paid separately. | 150 | RM | 550 ₹82,500 | 470 ₹70,500 | 450 ₹67,500 | 380 ₹57,000 Lowest |
| 8.00 | Supply and fixing for double wall corrugated HDPE non pressure pipe suitable for sewage/ waste etc of size DN/ID 200mm, dim 195mm and wall thick e4 min-1.5mm and e5 min-1.00mm all as per IS16098 (part-2), including jointing rings and necessary machinery to joint the sewers in-situ in trenches, including preparation of internal surface complete all as specified and directed .
Note:- Excavation and earth work including return filling shall be measured and paid separately. | 80 | RM | 600 ₹48,000 | 500 ₹40,000 | 450 ₹36,000 | 280 ₹22,400 Lowest |
| 9.00 | Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed. | 31.5 | Cum | 5 ₹157.5 Lowest | 50 ₹1,575 | 50 ₹1,575 | 20 ₹630 |
| 10.00 | Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre high from the starting point, complete all as specified and as directed. | 10.5 | Cum | 5 ₹52.5 Lowest | 50 ₹525 | 65 ₹682.5 | 50 ₹525 |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
24 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
REPAIR / REPLACEMENT / CLEANING OF SEWAGE LINES, SEPTIC TANKS, SOAKAGE WELLS, DRAINS AND ALLIED WORKS AT 8FBSU, AF AWANTIPUR
2026_MES_786562_1
GE (AF) AWA-38/2026-27
Open Tender
Civil Works
Item Rate
330 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹60,000
Yes
29 Oct 2026
27 Aug 2026
26 Sept 2026
27 Aug 2026
24 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning and make it functioning sewage system by removing of all types of blockages from soil waste/rain water pipes, CI waste pipes, blockages of Toilets/bathrooms/WHB of bldgs upto G+2 storey height or in trenches, sewage line of any dia including junction of manholes of any description, man holes and septic tanks of any size and depth upto the last manhole to septic tanks of central sewage system to keep smooth functioning without any blockage of any description and in any situation with manually or some mechanically processes for all locations under GE (AF) Awantipur all as specified , by providing one safaiwala per day including all necessary tools and plants like bamboos, iron rod, bucket, rope, ladder etc .Contractor or rep of contractor has to attend sub-division on a daily basis to collect the complaints. complaints should be resolve within 24 Hrs without fail. | 11 | Per Month | - | - |
| - | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft/loose soil, complete all as specified and as directed. | 40 | Cum | - | - |
| - | All as per item no 02 here in above but exceeding 1.5 deep and not exceeding 3m deep complete all as specified an directed. | 2 | Cum | - | - |
| - | Demolition of cement concrete (unreinforced) as in bed to drain pipes of any description and in any position, complete all as specified and as directed.
Note :- Demolition of of SGSW pipes of any dia shall be included in this items and shall be measured as solid. | 12.08 | Cum | - | - |
| - | M&L for Concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in plain cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed. | 150 | RM | - | - |
| - | M&L for Concrete bed to 200mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in Plain cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed. | 80 | RM | - | - |
| - | Supply and fixing for double wall corrugated HDPE non pressure pipe suitable for sewage/ waste etc of size DN/ID 150mm, dim 195mm and wall thick e4 min-1.5mm and e5 min-1.00mm all as per IS16098 (part-2), including jointing rings and necessary machinery to joint the sewers in-situ in trenches, including preparation of internal surface complete all as specified and directed .
Note:- Excavation and earth work including return filling shall be measured and paid separately. | 150 | RM | 4 | ₹600 |
| - | Supply and fixing for double wall corrugated HDPE non pressure pipe suitable for sewage/ waste etc of size DN/ID 200mm, dim 195mm and wall thick e4 min-1.5mm and e5 min-1.00mm all as per IS16098 (part-2), including jointing rings and necessary machinery to joint the sewers in-situ in trenches, including preparation of internal surface complete all as specified and directed .
Note:- Excavation and earth work including return filling shall be measured and paid separately. | 80 | RM | 4 | ₹320 |
| - | Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed. | 31.5 | Cum | 5 | ₹157.5 |
| - | Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre high from the starting point, complete all as specified and as directed. | 10.5 | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
tender38.pdf
Tender Documents • 2.03 MB
BOQ_881450.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .