| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹34.0 L+₹2.9 L (9.25%)Rejected-Finance B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹37.6 L+₹6.5 L (20.9%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L-3 | Rejected-Finance other than the lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical CONDITIONS NOT COMPILED WITH | |
| 5 | Rejected-Technical | - | Rejected-Technical CONDITIONS NOT COMPILED WITH |
| Sl No | Description | Qty | Unit | SAMEER ELECTRICAL SUPPLIER L2 | PRAGATI ELECTRICALS AND ELECTRONICS L3 | MODI CORPORATION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Periodical & preventive maintenance of (quarterly basis) including repair, renewal/ replacement of defective parts of mechanical laundry and complete check by appropriate instrument such as open and refitted gears, ball bearing, cleaning stem pipe lines & valves etc mechanical laundry to wash, dry and ironing for an average load of various types of solid linen and including following equipments/machinery for 149 BEDS at MH BHOPAL complete all as specified and directed.
Details of plant and equipments are as follows: -
(i) Fully computerized Washing Machine, Washer Extractor, 45 Kg Capacity per charge, with High spin Extraction feature (with inbuilt Hydro Extractor) steam Heated, -01 No.
(ii) Fully computerized Washing Machine, Washer Extractor, 20 Kg Capacity per charge, with High spin Extraction feature (with inbuilt Hydro Extractor) steam Heated- 01 No.
(iii) Sluicing Machine, 20 Kg capacity per charge, with High Spin Extraction feature (With inbuilt Hydro Extractor) with G force not less than 300. -02 No.
(iv) Drying Tumbler, 30 Kg cap per charge, Steam Heated through stainless steel steam coils and aluminium fins. - 02 No.
(v) Flat work Ironer, single Roller, Chest Heated through steam with air suspended ironing chest, pneumatic lowering rising and lowering adjustable pressure 180 Degree contact angle. - 01 No.
(vi) Wash linen trolley (for wet/dry linens) made out of Stainless-Steel tubes & Stainless-Steel cladding. Size: 1000 mm X 800 mm X 800mm.
(vii) Shelf trolley made of stainless-steel size 1400 mm (w) X 700 mm (d) X 1900 mm (h) mm with castor wheel - 04 Nos.
(viii) Single sink (1 person operated) microprocessor based manual shrub station size 40"" (L) X 24"" (W) X 48"" (H) made of stainless steel-304 grade operated on 230 V AC 50 Hz complete -01 No.
(ix) Mobile table with stainless steel top and shelfs of size 1330 mm (w) X 900 mm (d) X 1000 mm (h) with castor wheel - 04 Nos.
(x) Single sink stainless steel scrubbing station complete. | 4 | Per Quarter | 15,000 ₹60,000 Lowest | 20,300 ₹81,200 | 24,000 ₹96,000 |
| 1.01Item 1.00 contd/…. Scope of periodical and preventive maintenance includes the following: - (i) To check the alignment of all machineries and rectify if necessary. (ii) To check and correct the weight arrangement of each machine and adjustment it by the microprocessor card. (iii) Oiling and greasing of each machine by mechanical method like adjustment of pressure pump etc. (iv) Check all electric connections to each equipments/machines and rectify if necessary. (v) Cleaning, oiling and servicing tank of capacity 1000 litres - 01 No. (vi) To check and re-fixing of single rolling chest for steam with air suspended iron chest. (vii) Check and calibrate Vacuum Ironing Table, Size of the table 4' x 2.5' with imported steam iron and fittings. -03 Nos. (viii) Check Hand iron for pressing the clothes, 6.5 Kg weight 1 'rWJ capacity suitable for 230 V, Single phase, 50 HZ AC -01 No. (ix) Through check of Air compressor capable of delivering 6 kg/cm² compressed air at delivery point with tank capacity 150 litre - 01 No. (x) Checking of Compressor air supply pipe lines complete. -01 Job. (xi) Water softening plant suitable to deliver 1000 litres per hour soft water having hardness of less than 5 PPM including all accessories as required complete - 01 No. Note: - Other conditions (i) The tenderer shall provide one technician/site engineer along with necessary staff and requisite T&P quarterly for inspection of plant and to rectify faults for smooth functioning of the mechanical laundry plant. (ii) The minor part required during periodical maintenance for smooth functioning of mech laundry should be included in the unit rate quoted by the tenderer. (iii) The major part should be replaced (only if required) and measured & paid separately. | ||||||
| 2.00 | Periodical maintenance (Quarterly basis) Boiler of make Thermax capable of generating steam 400 Kg per hour at 100DC having reverse of fuel technology steam output at safety valve set pressure of 10.5 Kg per square centimetre, LDO/HSD operated fixed complete at MH Bhopal complete all as specified and directed.
The purpose of the annual service contract is to:
(i) Ensure SMOOTH operation of system / Ensure up time.
(ii) Corrections in Operation & Maintenance Practices to explore the chances of Operating Cost Reduction.
(iii) Check the possibility of operation cost reduction by modifications. Efficiency optimization improvement.
(iv) To get the Maximum out of Annual Maintenance of the System.
(v) Better planning for Spares/consumable Stocking to avoid the delay at the time of break down,
though as authorized franchisee of Thermax, we are maintaining sufficient quantity of spares in our Bhopal Go down.
(vi) 100% availability of the unit for the service run.
Scope of ANNUAL SERVICE CONTRACT: The ANNUAL SERVICE CONTRACT for the Softener Plants shall be offered in 6: 6:1 i.e., six visits of one day each for the once in two months (General Check-up), Six visits breakdown (on demand), one visit for over hauling. | 4 | Per Quarter | 8,500 ₹34,000 Lowest | 10,300 ₹41,200 | 15,500 ₹62,000 |
| 2.01Item 2.00 contd/…. Details of the work description during visit is as under Once in two months Visits: This shall be a “1 DAY VISIT” once in two months during which the following activities shall be carried out: (i) Overall Survey of the Installation. (ii) Check number of streams & flows etc. (iii) Check Inlet/Outlet parameters, Flow rates." "(iv) Intermediate quality parameters. (v) Evaluation of available Instrumentation. (vi) Log books details. (vii) Specific Problems if any. BREAK DOWN Visit: Three visits are planned for break down. If more visits are paid for attending break down, they will be adjusted with once in two months visits. (i) Learn the detail background of the problem on the phone prior to the B/d visit. (ii) Identify and resolve the problem immediately, if possible, through guidance or arrest the Symptoms. (iii) Identify problem. (iv) Root Cause analysis. (v) Rectify the problem at root cause. (vi) Equipment put back in action. (vii) Inform customer nature of breakdown / malfunctioning, cause of the problem and the solution. (viii) Also inform the customer about the action taken / to be taken. (ix) Inform customer about the action to be taken to avoid repetition of problems. (x) Track breakdown, component failures. (xi) Unit put back in to operation. OVERHAULING Visit: This shall be OVERHAULING visit once in year for the period of 1-2 days maximum depending on the size of the unit. EXCLUSIONS FROM ANNUAL SERVICE CONTRACT (i) Any Spares Supply if required. (ii) Any Chemicals, lubricants, consumables etc. if required. (iii) Detailed Analysis of Influent & Outlet Effluent if required. We will do standard analysis by which we can optimize the unit and check the performance, like TDS, pH, TH, Talk, Cl, etc. (iv) Facilities for Inspection & Checking if required. Note :- The tenderer shall provide one technician/site engineer along with necessary staff and requisite T&P for inspection of plant on daily basis and to rectify faults for smooth functioning of the steam boiler. | ||||||
| 3.00Replacement of broken/burnt out spare part (only if required):- | ||||||
| 3.01 | Supply only Door gaskets for washing machines | 3 | Each | 1,200 ₹3,600 | 1,580 ₹4,740 | 500 ₹1,500 Lowest |
| 3.02 | Supply only Air solenoid valve | 3 | Each | 2,000 ₹6,000 | 330 ₹990 Lowest | 800 ₹2,400 |
| 3.03 | Supply only Reverse forward timer | 2 | Each | 1,100 ₹2,200 Lowest | 1,140 ₹2,280 | 1,400 ₹2,800 |
| 3.04 | Supply only Grease | 3 | Kg | 150 ₹450 | 153 ₹459 | 120 ₹360 Lowest |
| 3.05 | Supply only Oil for machine suitable to existing one | 1 | Litres | 250 ₹250 | 268 ₹268 | 200 ₹200 Lowest |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Nov 2025, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR MAINTENANCE OF AC PLANTS, AHUs, CERTAIN SUMMER APPLIANCES, WALKING COOLER, TOWER ACs, MORTUARY BODY CABINET AND FIREFIGHTING SYSTEM, NURSE CALLING BELLS, FIRE ALARM SYSTEM, MECH LAUNDARY, SOFTNER PLANT, DG SETS AND MISC ITEMS AT MH BHOPAL UNDE
2025_MES_735646_1
84105/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹82,000
Yes
27 Dec 2025
16 Oct 2025
8 Nov 2025
16 Oct 2025
6 Nov 2025
31 Oct 2025
16 Oct 2025 - 31 Oct 2025
Amount
Periodical & preventive maintenance of (quarterly basis) including repair, renewal/ replacement of defective parts of mechanical laundry and complete check by appropriate instrument such as open and refitted gears, ball bearing, cleaning stem pipe lines & valves etc mechanical laundry to wash, dry and ironing for an average load of various types of solid linen and including following equipments/machinery for 149 BEDS at MH BHOPAL complete all as specified and directed. Details of plant and equipments are as follows: - (i) Fully computerized Washing Machine, Washer Extractor, 45 Kg Capacity per charge, with High spin Extraction feature (with inbuilt Hydro Extractor) steam Heated, -01 No. (ii) Fully computerized Washing Machine, Washer Extractor, 20 Kg Capacity per charge, with High spin Extraction feature (with inbuilt Hydro Extractor) steam Heated- 01 No. (iii) Sluicing Machine, 20 Kg capacity per charge, with High Spin Extraction feature (With inbuilt Hydro Extractor) with G force not less than 300. -02 No. (iv) Drying Tumbler, 30 Kg cap per charge, Steam Heated through stainless steel steam coils and aluminium fins. - 02 No. (v) Flat work Ironer, single Roller, Chest Heated through steam with air suspended ironing chest, pneumatic lowering rising and lowering adjustable pressure 180 Degree contact angle. - 01 No. (vi) Wash linen trolley (for wet/dry linens) made out of Stainless-Steel tubes & Stainless-Steel cladding. Size: 1000 mm X 800 mm X 800mm. (vii) Shelf trolley made of stainless-steel size 1400 mm (w) X 700 mm (d) X 1900 mm (h) mm with castor wheel - 04 Nos. (viii) Single sink (1 person operated) microprocessor based manual shrub station size 40"" (L) X 24"" (W) X 48"" (H) made of stainless steel-304 grade operated on 230 V AC 50 Hz complete -01 No. (ix) Mobile table with stainless steel top and shelfs of size 1330 mm (w) X 900 mm (d) X 1000 mm (h) with castor wheel - 04 Nos. (x) Single sink stainless steel scrubbing station complete.
Item 1.00 contd/…. Scope of periodical and preventive maintenance includes the following: - (i) To check the alignment of all machineries and rectify if necessary. (ii) To check and correct the weight arrangement of each machine and adjustment it by the microprocessor card. (iii) Oiling and greasing of each machine by mechanical method like adjustment of pressure pump etc. (iv) Check all electric connections to each equipments/machines and rectify if necessary. (v) Cleaning, oiling and servicing tank of capacity 1000 litres - 01 No. (vi) To check and re-fixing of single rolling chest for steam with air suspended iron chest. (vii) Check and calibrate Vacuum Ironing Table, Size of the table 4' x 2.5' with imported steam iron and fittings. -03 Nos. (viii) Check Hand iron for pressing the clothes, 6.5 Kg weight 1 'rWJ capacity suitable for 230 V, Single phase, 50 HZ AC -01 No. (ix) Through check of Air compressor capable of delivering 6 kg/cm² compressed air at delivery point with tank capacity 150 litre - 01 No. (x) Checking of Compressor air supply pipe lines complete. -01 Job. (xi) Water softening plant suitable to deliver 1000 litres per hour soft water having hardness of less than 5 PPM including all accessories as required complete - 01 No. Note: - Other conditions (i) The tenderer shall provide one technician/site engineer along with necessary staff and requisite T&P quarterly for inspection of plant and to rectify faults for smooth functioning of the mechanical laundry plant. (ii) The minor part required during periodical maintenance for smooth functioning of mech laundry should be included in the unit rate quoted by the tenderer. (iii) The major part should be replaced (only if required) and measured & paid separately.
Periodical maintenance (Quarterly basis) Boiler of make Thermax capable of generating steam 400 Kg per hour at 100DC having reverse of fuel technology steam output at safety valve set pressure of 10.5 Kg per square centimetre, LDO/HSD operated fixed complete at MH Bhopal complete all as specified and directed. The purpose of the annual service contract is to: (i) Ensure SMOOTH operation of system / Ensure up time. (ii) Corrections in Operation & Maintenance Practices to explore the chances of Operating Cost Reduction. (iii) Check the possibility of operation cost reduction by modifications. Efficiency optimization improvement. (iv) To get the Maximum out of Annual Maintenance of the System. (v) Better planning for Spares/consumable Stocking to avoid the delay at the time of break down, though as authorized franchisee of Thermax, we are maintaining sufficient quantity of spares in our Bhopal Go down. (vi) 100% availability of the unit for the service run. Scope of ANNUAL SERVICE CONTRACT: The ANNUAL SERVICE CONTRACT for the Softener Plants shall be offered in 6: 6:1 i.e., six visits of one day each for the once in two months (General Check-up), Six visits breakdown (on demand), one visit for over hauling.
Item 2.00 contd/…. Details of the work description during visit is as under Once in two months Visits: This shall be a “1 DAY VISIT” once in two months during which the following activities shall be carried out: (i) Overall Survey of the Installation. (ii) Check number of streams & flows etc. (iii) Check Inlet/Outlet parameters, Flow rates." "(iv) Intermediate quality parameters. (v) Evaluation of available Instrumentation. (vi) Log books details. (vii) Specific Problems if any. BREAK DOWN Visit: Three visits are planned for break down. If more visits are paid for attending break down, they will be adjusted with once in two months visits. (i) Learn the detail background of the problem on the phone prior to the B/d visit. (ii) Identify and resolve the problem immediately, if possible, through guidance or arrest the Symptoms. (iii) Identify problem. (iv) Root Cause analysis. (v) Rectify the problem at root cause. (vi) Equipment put back in action. (vii) Inform customer nature of breakdown / malfunctioning, cause of the problem and the solution. (viii) Also inform the customer about the action taken / to be taken. (ix) Inform customer about the action to be taken to avoid repetition of problems. (x) Track breakdown, component failures. (xi) Unit put back in to operation. OVERHAULING Visit: This shall be OVERHAULING visit once in year for the period of 1-2 days maximum depending on the size of the unit. EXCLUSIONS FROM ANNUAL SERVICE CONTRACT (i) Any Spares Supply if required. (ii) Any Chemicals, lubricants, consumables etc. if required. (iii) Detailed Analysis of Influent & Outlet Effluent if required. We will do standard analysis by which we can optimize the unit and check the performance, like TDS, pH, TH, Talk, Cl, etc. (iv) Facilities for Inspection & Checking if required. Note :- The tenderer shall provide one technician/site engineer along with necessary staff and requisite T&P for inspection of plant on daily basis and to rectify faults for smooth functioning of the steam boiler.
Replacement of broken/burnt out spare part (only if required):-
Supply only Door gaskets for washing machines
Supply only Air solenoid valve
Supply only Reverse forward timer
Supply only Grease
Supply only Oil for machine suitable to existing one
Supply only 36 Amp on load Auto Contactor 3 pole/4 pole as per existing one
S & F 25 mm Stainless steel pipe of each 06 Rm length set grade 304 seamless pipe or as per existing size for steam circulation as per existing one including taking down existing one complete all as specified and directed.
S & F 15 mm Stainless steel pipe set grade 304 seamless pipe or as per existing size for steam circulation as per existing one including taking down existing one complete all as specified and directed.
S & F Bush as per existing one including taking down existing one complete all as specified and directed
S & Fix pulley as per existing one including taking down existing one complete all as specified and directed
S & F valve of size 65 mm including its actuator motor as per existing one including taking down existing one complete all as specified and directed
M& L for servicing repairing of Motors including rewinding of capacity 5 to 7.5 HP s per existing one including taking down existing one complete all as specified and directed Note:- Replacement of following spares (only if required):-
M &L for servicing of water softner plant installed at MH Bhopal including dismantling existing system and descaling with chemical etc complete all as specified and directed and
Supply only PLC for Softner plant as per existing one
LDPE Tank 80 litre of Make :- Thermax
Chemical for descaling Max clean 0.5 Make; - Thermax
Salt for softener
Multiport valve 20NB as per sample
Resin for softner plant suitable to existing one
Valve globe- gm-thd-3/4” bspt
Valve globe- gm-thd-1” bspt
Supply and fix Butterfly valve of size 80mm
S & F in repalcement miniature circuit breakers (MCB), four pole with four protected pole (FP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete including taking down existing one complete all as specified and directed.
S & F miniature circuit breakers (MCB), four pole with four protected pole (FP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 including taking down existing one complete all as specified and as directed.
Servicing and repairing of RO/water purifier/Aquaguard of any make and capacity upto 20 Ltr/hr (quaterly basis) including servicing, repair, renewal/ replacement of complete filters including replacement of pre filter and defective spare parts if required to make it functional are deemed to inclusive of quoted rate, complete all as specified and directed. Qty of RO/Aquaguard/Water purifier of any make - 01 Job (Total 16 Nos of RO).
Periodical/Preventive maintenance as per recommended by (Quarterly basis) walk in cooler of make :- Blue Star of size 8' x 8' x 8' for preserving life saving medicine and medical stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 1 TR/12000 BT U/Hr (one working and other standby) including repair of short circuit/damaged wiring ,maintenance of cold room panel,front display Controller, Temperature control panel, Servicing of Indoor/outdoor unit including gas charging complete. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer should quote the rate including oiling,greasing & minor spare parts as required.
Periodical/Preventive maintenance as per recommended by (Quarterly basis) of walk in cooler of make :- Blue Star of size 15' x 12' x 10' for preserving vegetable/meat stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 5 TR/60000 BT U/Hr (one working and other standby) including repair of short circuit/damaged wiring , wiring ,Servicing of Indoor/outdoor unit,Repair of cold room panel,front display controller,Temperature control panel including gas charging complete. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shuold quote the rate including oiling,greasing & minor spare parts as required.
Replacement of broken/burnt out spare part (only if required):-
Repair/Replacement of Compressor for outdoor unit no 1 Model RUAHO6024CS / RUAHOP1514.
Repair of PCB including replacement of PCB Component
Replacement of PCB as per existing one complete all as specified and directed
Repair of blower fan heavy duty of size 650mm sweep including rewinding of motor etc or as per site requirement.
Periodical maintenance (Quarterly basis) of Mortuary cabinate for two body of make :- Blue star ,230 volt single phase, 50 hz with roof mounted refrigeration system of capacity 6000 BTU/H, temperature range from 2 degree C to 6 degree C , complete with 1 piece stainless steel tray with handle including addressing any breakdown of machines and repair of short circuit/damaged wiring ,Servicing and cleaning of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM/recommended by OEM/ Experience techinicains only. 2. Tenderer shuold quote the rate including oiling,greasing & minor spare parts as required. 3. Two Body single cabinet - 04 Nos shall be measured as 1 Job.
S & Fix compressor as per existing one including taking down existing one complete all as specified and directed. (Model of existing compressor is KCJ513)
S & Fix microprocessor temperature controller with digital display including toggle switch and ON/OFF indicator as per existing one complete all as specified and directed
Repair/Maint and servicing of Air Curtain with adjustable loures with electric motor single phase 230 volts AC, 50 hz with maximum velocity 10-11 Amps (1000mm width). Air speed 20M/S of Make Cecon modle No C1-042 including repair of short circuit/damaged wiring,servicing, repair/replacement of defective parts if required complete all as specified and directed.
Periodical maintenance (Qtrly basis) of Tower AC of capacity 4 TR 05 Nos & 2 TR 01 Nos ,415 volt three phase, 50 Hz for operating on R-32 refrigerant,Servicing of Indoor/outdoor unit excluding gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only. 2. Tenderer shuold quote the rate including oiling, greasing & minor spare parts as required. 3. Servicing of 4 TR-05 Nos and 2Tr-01 Nos shall be measured as 01 Job
Material and labour for taking down window type Air Conditioner of 1.5 TR / 2.0 TR, cleaning completely of cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water and refixing at same location with complete testing complete all as specified and directed.
M&L for dismantling covers of out-door and in-door units of split type Air Conditioner of capacity 1.0TR/1.5TR/2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, re-fixing the covers in same position complete all as specified and directed.
M&L for carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging as per existing and and transporting & carrying out T&P required at site for the following capacity of ACs, water coolers, refrigerators & deepfreezers complete all as specified and directed. Note :- The rate under mentioned items included for transpotation of AC to & from work shop as approved by Engr -In -Charge.
Window type AC of capacity up to 2.0 TR
Split type AC of capacity up to 2.0 TR.
Refrigerator of capacity 175 ltrs to 300 ltr
Water cooler of capacity 40 Ltr to 80 ltrs
Deepfreezer of capacity upto 410 ltrs
M&L for taking out of condensing coil fan motor from the AC unit, dismantling, cutting burnt coils, cleaning and rewinding using supper enameled copper wire of existing size and gauge including replacement of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as specified and directed for the following :-
Window type AC of capacity 1.0 TR/1.5TR/2.0 TR
Split type AC of capacity 1.0 TR/1.5TR/2.0 TR
Water cooler of capacity 40 Ltr to 120 ltrs
Deepfreezer of capacity upto 410 ltrs
Labour, tools & mechinaries for collecting the complaints of various wards/departments etc pertains to split/window type ACs/Tower AC/Water cooler/Deep Freezer/Regrigerator of any capacity/make from concern JE E/M and attendending these at site to asses the actual fault after opening of ACs inclding water leakage repair and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE complete all as specified and directed. (Spare parts shall be measured and paid separately under following items as supply only) Note :- The rate under mentioned items included for transpotation of any type of ACs to & from work shop as approved by Engr -In -Charge.
Supply only Running capacitor 50 mfd
Supply only Running Capacitor 4/6 mfd
Supply only Coppr capillary Tube as per existing size.
Supply only Filter strainer
Supply only Air filter made of plastic frame and nylon net
Supply only indoor unit Temparature censor for split type AC
Supply only outdoor unit temparature censor for split type AC.
Supply only Running capacitor 50 Mfd + 6 Mfd up to 2 ton split type AC
Supply only Blower motor for window/Split Type AC upto 2 Ton capacity as per existing
Supply only Remote suitable for window/Split AC
Supply only Front grill for window AC as per existing
Supply only PCB Board for Window/split type AC
Supply only PCB Board for Dual type inverter split AC
Supply only Rubber bushing for blower motor
Supply only Swing motor for split type AC of capacity 1.0 TR/1.5TR/2.0TR.
Supply only Display assembly for spilit type AC
Supply only Sensor for Indoor unit.
Supply only Copper tube cooling/condensor coil 5/8 inch with proper insulation
Supply only Copper tube cooling/condensor coil 1/2 inch with proper insulation
Supply only Copper tube cooling/condensor coil 1/4 inch with proper insulation
Supply only Fan blade set as per existing
Supply only Fan motor 1/5 HP, single phase, 240 volts (as per existing)
Supply only Fan capacitor of capacity 3/4/5 mfd, 230 volt, ISI marked .
Supply only Pencil battery for ACs remotes of size AAA, 1.5 V (Set of two)
S & F in replacement hermitically sealed / Rotary type compressor of Capacity 1.5/2.0 TR as per requirement at site for Window/Split Air conditioner complete all as specified and directed.
Removing the unserviceable compressor sealed unit of any make from water cooler capacity 40/80 liters after cutting copper tubing without any damage to existing parts and S & F for replacing new compressor with reconditioned compressor of same make with erection of compressor on base with suitable capillary, filter, etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing, etc including testing for smooth functioning complete all as specified and as directed.
M&L for removing the condenser fan motor from water cooler of 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
S&F in repairs Plastic fan blade suitable for water cooler of capacity 40/80 Litres complete all as specified and as directed.
S&F in repairs thermostate suitable for water cooler of any capacity complete all as specified and as directed.
M&L for servicing of Deep freezer of capacity upto 410 ltrs of any make, checking / testing all parts for its serviceability, oiling / greasing of condenser motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and as directed.
S&F in repairs condensing coil suitable for Deep freezer of capacity upto 410 ltrs complete all as specified and as directed.
M & L for shifting of air conditioner split type of any make from its original position to another position with and including making good of existing surface/wall etc and making new drilling in walls and fixing factory made outdoor unit stand etc and and required electric work after disconencting the same if required , locking of gas and vacumming of coil while installation complete all as specified and directed. Note:- Copper tube and Outdoor unit stand shall be paid and meausred seperately
S & F Starting relay suitable for 1.0 /1.5 /2.0 TR compressor. Make: HI-tech/Classic or as per recommended by manufacturer or equivalent as approved by GE.
Charging of refrigerant gas R-22/R-32 in window / split type air conditioners 1.5 / 2.0 TR / Mortury cabinet/ Tower AC's/Walk in cooler/Desert Cooler etc at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
Charging of refrigerant gas R-134a for deep freezer /refrigerator/water cooler /Central AC Plant at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/MES store yard after repairing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
M&L for cutting and removing unserviceable freezer unit of refrigerator capacity 165 to 310 litres of any make, and S&F new freezer unit with door and chiller tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and as directed.
S&F in repairs thermostat suitable for refrigerator 165 to 310 liters capacity complete all as specified and as directed.
S&F in replacement of 3 Pole Ax Control contactor (3 NO + 1 NC), AC 415 V, 50 Hz , 3 phase of Control panel complete all as specified and directed. [Make-Siemens/ABB Model N31E ** 1SBH141001R31 /L&T or equivalent as approved by GE.]
S&F in replacement 3 Pole Ax conatctor 32 Amp AC3 , (1 NO ) AC 415 V, 50 Hz , 3 phase for contractor of Control panel complete all as specified and directed. [Make-Siemens/ABB Model AX32-30-10 /L&T or equivalent as approved by GE.]
S&F in replacement 3 Pole Ax conatctor 09 Amp AC3 , (1 NO ) AC 415 V, 50 Hz , 3 phase for contractor of Control panel complete all as specified and directed. [Make-Siemens/ABB Model AX09-30-10 /L&T or equivalent as approved by GE.]
S & F Front mounted single pole add-on blocks 1 NC complete all as specified and directed. [Make-Siemens/ABB Model CA5 -01/L&T or equivalent as approved by GE.]
S&F in replacement MCCB of control panel, 50 KA breaking capcity, 3 phase , 4 Pole AC , 320-400 range with Ics=Icu 100% and adjustable Thermal Magnetic Protection as per site requirement complete all as specified and directed.
S&F in replacement MCCB of control panel, 25 KA breaking capcity, 3 phase, 3 Pole AC , 100 A with Ics=Icu 100% and adjustable Thermal Magnetic Protection range as per site requirement complete all as specified and directed.
S & F in repalcement of Automatic Air vent valve of Brass 1/2 inch with suitable to operating 10 Bar pressure complete all as specified and directed.
S&F in replacement Stop valves of 15mm dia , cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed or new position complete all as specified and directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 2000 litres capacity hoisted and fixed in position including provision of tank nipples 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed.
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 25mm thickness of insulation complete all as specified and directed and including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Removing the unserviceable compressor sealed unit of refrigerator of capacity 165 to 310 liters of any make and M&L for replacing the compressor with new compressor of same make & model complete, installing in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including testing for smooth functioning complete all as specified and as directed.
M&L for taking out fan motor single phase 230 Volts, 1400 RPM, 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and as directed.
S&F in repairs desert cooler motor of three speed, ISI marked, 1400 RPM, single phase,copper wounded motor with ring, side legs, necessary bolts and nuts of capacity 1/8 HP complete all as specified and as directed. Make - Usha/C&G/Khaithan or equivalen as approved by GE.
S&F body of 22 gauge suitable for coolers of capacity 18 Guage with water tank complete all as specified and as directed.
S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 4000 Cum / hrs capacity desert cooler complete all as specified and as directed.
S&F in repairs front grill / louvers to desert cooler made out from 0.8 mm thick GI sheet suitable for 5000 /4000 Cum / hrs capacity desert cooler of any make complete all as specified and as directed..
S&F in repairs PVC flexible pipe 16 mm outer dia with bends for desert cooler complete with PVC elbow complete all as specified and as directed.
S&F in repairs wood pad (Set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as specified and as directed.
S&F in repairs sumbersible pump 230 Volts, 1/60 HP, ISI Marked for desert cooler including pump support plate fabricated with 0.4 mm thick GI sheet with fixing screws, nuts and bolts complete all as specified and as directed. [Make : Khaitan/Polar/GEC or equivalent as approved by GE]
S&F in repairs capacitor 4 MFD for fan motor of desert cooler complete all as specified and as directed.
S&F in repairs iron fan blade powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and as directed.
Repair & comprehensive maintenance of DG sets of make of capaciy 750 KVA which include replacement of worn out spares such as fuel filter, oil filter, lubricating oil hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nut bolts, washers etc of DG sets complete all as specified and directed. (Note :- Spares shall be mesured & paid separetely)
Supply only following spare parts for 750 KVA of Make:- Kirloskar complete all as specified and directed:-
Primary and secondary Fuel Filter
Lubricating Oil Filter
Hose Pipe Set
Descaling, Cleaning and brazing as necessitated to plug leakages, dismantling and taking down radiator assy from engine of any capacity for repairs including transporting of the radiator (if required) of capacity 750 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re-fixing after repairs including replacement of worn out nut bolts, washers, etc; and testing complete all as specified and directed. (Note :- Coolant shall be measured & paid separetely)
Dismantling and removing fuel injection pump from DG set for repairs including re-calibration, including cleaning of its nozzels replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified and directed for 750 KVA capacity DG set.
Supply only Lubrication Oil 15 W 40 complete all as specified and directed.
Supply only Lubrication Oil 20 W 40 complete all as specified and directed.
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc; all as necessitated complete all as specified and directed. Note:- All additional spares as required will be measured and paid seperately.
Supply only battery lead, single core copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends complete all as specified and directed.
Supply only Fan belts as per sample for DG of capacity 750 KVA complete all as specified and directed.
Supply only water pump suitable for 750 KVA DG set complete all as specified and directed.
S & F in replacement of S.D. Valve for 750 KVA DG set complete all as specified and directed.
Supply only Coolant additive concentrate pack of 10 Ltr suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
Supply only air filter outer & inner element for 750 KVA DG set as per sample complete all as specified and directed.
M&L in replacement maintenance free lead acid battery 12 volt, 180 AH with minium 36 months warranty) of complete all as specified and directed.
Supply in repair Battery terminal heavy duty brass with nut & bolts complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down existing one complete all as specified and directed.
M & L for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed 2x1.5 sq. mm + 1x1.5 sq. mm earth wire ® in PVC conduit including taking down existing one complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (Socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M & L for point wiring of One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size in PVC Casing caping complete all as pecified and directed
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade, etc. complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
M & l for replacement of microprocessor based main control panel of 10 zones having provision of indicator for fire alarm, fire, fault,open/short earth circuit complete.
M & L for replacement of Zonal Indicator panel for fire alarm system zonal panel of upto 6 zone having provision for indicator fire,fault, open/short earth circuit dulyinterfaced with main control panel complete all as specified and directed Model SD-1165.
M & L for replacement of Repeater Panel for fire alarm system repeator panel of mann control panel having provision of Audio Video indicators for fire, fault, open/short circuit duly interfaced with main control panel complete all as specified and directed.
M& L for replacement of Multi criteria heat cum smoke detector complete all as specified and directed.
M & L for replacement of response indicator for fire alarm system made of 1.6mm thick CRCA sheet having dual Red LED indicator complete all as specified and directed.
M & L for replacement of Siren for fire alarm system complete all as specified and directed.
M & L for replacement of copper conductor multi stranded armoured cable fixed on wall/ceiling with proper saddles/spacers of size 2 Core 1.5 Sqmm complete all as specified and directed.
M & L for replacement of Zone cards suitable to existing system complete all as specified and directed.
M & L for repalcement of Lead acid battery 12 V 7Ah complete all as specified and directed
S & F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt
S & F in repair 15 Amp 3 pin Top complete all as soecified and directed
Taking down of Solar water heating system of 100 ltrs per day capacity from its position after disconnecting water connections, and refixing /reassembling in position after carrying out servicing to the existing system and repairs and testing complete all as specified and directed. Note:- (a) Rate quoted by the contractor deemed to be included making good of missing nuts, bolts, washers, screws etc to make it full functional. (b) Descalling/desludging, cleaning and washing of solar panels, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required. (c) Painting to staging, solar panel frames, hot water tank frame with a coat of synthetic enamel paint including necessary preparation of surfaces complete. (d) Any other materials/parts need to be replaced by contractor and will be measured and paid seperately.
M & L for replacement of float cum boost charger for DG set battery suitable to existing one including taking down existing one complete all as specified and directed.
S&F in replacement AHU filter of size 610mm x 610mm x 50mm, efficiency - 90% down to micron and EU-4, size and CFM shall be as per site requirement complete all as specified and directed.
S&F in replacement AHU filter of size 350x610x50mm, efficiency - 90% down to micron and EU-4, size and CFM shall be as per site requirement complete all as specified and directed.
Taking out the filter from AHU up to 12000 CFM, cleaning the cooling coil with suitable chemical and jet of water pressure with pump and remove all the scales and foreign materials deposited in side coil followed with air pressure to sweep up all the paticles and ensure thorough flow of air over the cooling coil and refixing the air filter after cleaning complete all as specified and directed.
S & F in replacement of finned air double tube of capacity 3KW, total length 36" long, single phase 230 volt, 50 Hz suitable for AHUs complete all as specified and directed.
S&F in replacement AHU filter of size 305mm x 305mm x 50mm, efficiency - 90% down to micron and EU-4, size and CFM shall be as per site requirement complete all as specified and directed.
S & F in replacement strip heater element SP, 220 V, 50 Hz, 2 KW capacity, length 1.5' to 2.0' and as per site requirement including wiring and connection complete all as specified and directed.
S & F in replacement strip heater element SP, 220 V, 50 Hz, 3 KW capacity, length 1.5' to 2.0' and as per site requirement including wiring and connection complete all as specified and directed.
M & L for servicing of Primary & secondary pump and remove all dirt, rust of shaft impellor by machinery work etc. of capacity 7.5 HP and gland packing, studs and nut bolts with bushes with two coats of paints after primer on angle on which motor fixed etc. as required at the site complete all as specified and directed.
M & L for cleaning of condensing coil of AHU & valve with chemical solution by pressure pump with specific pressure for removal of dirt and scale deposited in pipe, solution to be recommended by OEM including supply and installation of double tube air heater 3 kW (Make Daspass) - 08 Nos with thermostat and make it functional from troubleshooting of humidity complete all as specified and directed.
Supplying and fixing of transformer 220 V AC to 24 V AC, AT140B1024 Class 2 PRI-1-COM, 2-208V,3-240V, 60 Hz, 0.22A SEC.-4-5 24VAC, 40 VA complete all as specified and directed.
Supply and fix of AHU actuator 24 V 50 Hz 6 VA Class 2 ML7420A8088-SBE065 Size DN 65/45/55 flow accuracy 4% 3/4 '' Stroke 1.0 min as per existing one complete all as specified and directed.
Supplying and fixing of AHU thermostate as per existing one complete all as specified and directed.
Supply and fix in repairs high efficiency particulate air filter (HEPA), flange type, anodised aluminium frame, filter media of micro glass fiber having water repellent property, Efficiency: 99.97% down to 0.3 micron, temperature resistance upto 1200C, humidity resistance upto 100% RH, minimum 1000 CFM air flow, including bag filter of size 610 mm X 610 mm X 305 mm complete all as specified and directed.
Supply and fix in repairs high efficiency particulate air filter (HEPA), flange type, anodised aluminium frame, filter media of micro glass fiber having water repellent property, Efficiency: 99.97% down to 0.3 micron, temperature resistance upto 1200C, humidity resistance upto 100% RH, minimum 500 CFM air flow, including bag filter of size 305 mm X 610 mm X 305 mm complete all as specified and directed.
Supply and fix in repairs high efficiency particulate air filter (HEPA), mini pleat box type, anodised aluminium frame, filter media of micro glass fiber having water repellent property, Efficiency: 99.97% down to 0.3 micron, temperature resistance upto 1200C, humidity resistance upto 100% RH, minimum 1000 CFM air flow, size 610 mm X 1219 mm X 90 mm complete all as specified and directed.
Supply and fix in repairs high efficiency particulate air filter (HEPA), mini pleat box type, anodised aluminium frame, filter media of micro glass fiber having water repellent property, Efficiency: 99.97% down to 0.3 micron, temperature resistance upto 1200C, humidity resistance upto 100% RH, minimum 750 CFM air flow, size 610 mm X 915 mm X 69 mm complete all as specified and directed.
S&F in replacement AHU blower shaft upto 12000 CFM, hollow or solid made out of high speed steel, including dismantling from existing AHU motor and its electric connection etc machine work up to required dia and length, making slot, key and hole and renewal of backet bearings as per site requirement and testing complete all as specified and directed.
M&L for pumping down/locking the existing refrigerant gas in separate cylinder immediately after end of season and at the starting of season carry out pressure leak test by nitrozen gas of the system of AC plant 3 X 250 TR for leak proof valve joint, seal other connected controls, flaries etc including identify & rectify of leak defects and maintaining constant pressure of 160lbs on low side and 200lbs at high side atleast 24 hrs complete all as specified and directed. Note : Topping up of Refrigerant R134a shall be measured and paid seperately
S&F in replacement thermostate programmable digital temperature control device for cut off in preset Cool/Hot conditions as per the sample complete all as specified and directed.
M & L for complete descaling of condenser, evaporator unit of chiller, Make: Voltas, Model No. ACEGWFXR2501MLS1, 250 TR by disconnecting from the system, cleaning by descaling solution as recommended OEM, cleaning condenser tube by nylon brush & mild steel rod of suitable size, replacement of rubber joints and unserviceable nut bolts including repair of leakage tube if any complete all as specified and as directed. Note: - Whole process of De-scaling should be done by Voltas Refrigerator Mechanics (OEM). Arrangement of required T & P e.g., pump, tube, descaling solution, etc shall be provided by the contractor.
Supply only compressor oil grade CP 120 and of specifications as existing at the site.
Supply only Oil Return Filter 3/8 and of specifications as existing at the site.
Supply only Slide Valve O Ring and of specifications as existing at the site
Supply only Oil filter dryer core of both refrigerant circuit and of specifications as existing at the site
Supply only Water Differential Switch and of specifications as existing at the site
Supply only MCS EVX Controller and of specifications as existing at the site
Supply only Suction Pressure Transducer and of specifications as existing at the site
Supply only Industrial type temperature sensor of evaporator entering, condenser entering and evaporation leaving discharge temp for chiller with complete pipe fittings of existing type and connected fittings and of specifications as existing at the site
Supply only Unloading Plunger and of specifications as existing at the site
Supply only Oil filter of both refrigerant circuit and of specifications as existing at the site
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size 80MM dia complete all as specified and directed.
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size 100MM dia complete all as specified and directed.
S & F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 65 mm as per IS 13095: 1991 complete all as specified and as directed.
S & F in repairs butterfly valve cast iron, PN 1.6, class 125, nominal size 50 mm as per IS 13095: 1991 complete all as specified and as directed.
Supply and installation in repair of 200 mm cast iron Y-type strainer flange ends with fittings (GI Nut Bolts, gasket etc) etc. complete all as specified and as directed.
Taking out old wornout mechanical oil seal of compressor at coupling end and replacing it with the recommended by OEM make, checking for no leakage of oil/gas, testing and commissioning to the entire satisfaction of Engineer in Charge complete all as specified and directed.. Note - Gas & Oil required to be charged after replacement of mechanical oil seal shall measured and paid seperately.
Taking out old defective burnout motor of capacity 25 HP, 3 phase, 440V, 50Hz from foundation and transfer it to workshop for rewinding with super eneamelled copper wire of existing size & guage and replacement of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning including required lathework if required complete all as specified and directed.
All as per serial item no. 124 but for motor of capacity 20HP complete all as specified and directed.
All as per serial item no. 124 but for motor of capacity 15HP complete all as specified and directed.
All as per serial item no. 124 but for motor of capacity 10HP complete all as specified and directed.
All as per serial item no. 124 but for motor of capacity 7.5HP complete all as specified and directed.
All as per serial item no. 124 but for motor of capacity 5HP complete all as specified and directed.
S & F in replacement fuses HRC cylindrical type model No. 3NA7260.OPC fuses of rating 400 Amps LT panel of AC plant complete all as specified and directed.
S&F in replacement 'C' Cash heater for compressor of make as per existing one complete all as specified and directed.
S&F in replacement of volume control air damper for AHU duct of modle No VCB ALCG manual type complete all as specified and directed.
S&F in replacement Phase Failure Relay with Under & Over Voltage setting of the LT panel of AC plant, 415 V, 50 Hz, 3 phase complete all as specified and directed.
S&F in replacement Phase Failure Relay with Under & Over voltage setting (Variable), Neutral Fail Indication, Auto / Manual Reset, Fixed Trip Time / Power ON Delay, OV/UV adjustable, 94V + 4V Unbalance of the LT panel of AC plant, 415 V, 50 Hz, 3 phase complete all as specified and directed.
S&F in replacement MCB of the LT panel of AC plant , 63 Amps, 3 pole, C- curve, AC , 415 V, 50 Hz, 3 phase, c-curve complete all as specified and directed.
S&F in replacement MCB of the LT panel of AC plant , 40 Amps, 3 pole, C- curve, AC , 415 V, 50 Hz, 3 phase, c-curve complete all as specified and directed.
S&F in replacement contractor of compressor control panel 3 phase, AC , 415 V not less than AC1 175A and AC3 140A all as per site requirement complete all as specified and directed.
S&F in replacement contractor of compressor control panel 3 phase, AC , 415 V not less than AC1 250A and AC3 205A all as per site requirement complete all as specified and directed. [Make-Siemens suitable to existing Model: 3TS53 and equivalent to 3TS5322-0A.1-8K /L&T/Hager or equivalent as approved by GE.]
Servicing/repair maintenace of AHU Control panels 33 Nos /Compressor Control panel 03 /Condensor Control panel 03/Cooling tower Motor control panel 03 Nos/ Secondary motor Control panel -03 etc complete all as specified and directed:- Scope of work shall be comprising following activities:- (a) Troubleshooting and finding of fault of control panel installed at AC Plant room/AHU room /outside AHU etc, Servicing and maintenace/repairs and replacement of defective components/ spare parts of control panels including checking of all accessories contactors, timers, relays VMR etc. installed at AC Plant room/AHU room /outside AHU. (b) Reports of healthyness and its related issued which is required to be rectify to all the systems to be mailed to AGE/JE on every visit. (c) To attend break down maintenance immediately and replacement of unservicable spare parts within 24 hours as required at site as directed by AGE/JE. (d) All components/spare parts replaced shall be measured and paid seperatly as mentioned in schedule and minor spare parts that is Aluminium/copper lugs/thibles/screws/nut bolt etc/crimping to wires etc deemed to be included in the unit rate quoted in item.
S&F in replacement thermal overload relay of range 24-32A, for control panel Type -Direct Mounting on contactors complete all as specified and directed.
S&F in replacement magnetic solenoid coil assembly complete with harness of compressor Loading circuit, Single phase, 6 to 18 Bar complete all as specified and directed.
S&F in replacement magnetic solenoid Coil 220 volts AC supply all as per sample complete all as specified and directed.
Supply & Fix phase indication lamps LED type with the colour code as per existing complete all as specified and directed.
S & F in replacement V-belt for AHU motor with the make and size as required and as per sample complete all as specified and directed.
Supply and fix cooling tower digital temerature sensor as per existing one complete all as specified and directed
Material and labour for servicing and rewinding of capacity 10 HP motor of Cooling tower motor complete all as specified and directed
S & F in replacement Transducer PT3-30 BAR of compressor with harness all as per site requirement complete all as specified and directed. [Make: - Voltas (PIN: M5186-10198P-030BG Model: M5 186-10198P-030BG) or equivalent as approved by GE.]
M & L for servicing of chiller / condensing pump & remove the all dirt, rust of shaft impellor by machinery work etc of capacity 25 HP and gland packing, studs and nut bolts with bushes with two coats of paints after primer on angle on which motor fixed etc as required at site complete all as specified and directed.
M & L for Air leakage testing on AHU Duct from one end to other end if any rectified immediately by repairing/welding complete all as specified and directed.
S & Fix recatngular type HVAC system canvas duct connector including Zip for open and close to check temperature of supply duct /return air duct of 200mm long suitable to existing system complete all as specified and directed.
S & F in replacement micro process computerised mother board plc controller suitable for Central AC Plant 250 TR Panel of Make: (MCS MAGNUM) FOR Voltas Chiller complete all as specified and as directed.
S & F Variable frequency drive (VFD) of 18.5 KW (25 HP) 50 Hz complete all as specified and directed.
Cleaning the cooling tower by cleaning chemical 1039XL,1031XL and applying wire brush, solvent by removing the deposited impurities such as silt, dust particles mud, sand inside the dome and around the fills, on wire mesh, main shaft etc and other connected items complete all as specified and directed.
S & F in replacement sprinkler of cooling tower of central AC Plant of cap 250 TR of Make as per the site or as per approved complete all as specified and directed.
S & F in repairs PVC fins in cooling tower, size 600 mm X 300 mm X 150 mm, honeycomb type, made of virgin PVC, to be installed in cooling tower for central AC Plant of capacity 250 TR of make as per site requirement or as per approved complete all as specified and directed.
S & F repairing and servicing including rewinding of CT motor of cooling tower of central AC Plant of capacity 2 X 250 TR of make as per site requirement or as per sample complete all as specified and directed.
S& fixing industrial thermometer -20 to 50o C & 0 to 1200 F for chilled water and return water pipe line complete all as specified and directed
S& fixing dial type of 100mm dia pressure guage for chilled water and return water pipe line as per existing one complete all as specified and directed
S&F in replacement AHU filter of size 580mm x 580mm x 50mm, efficiency - 90% down to micron and EU-4, size and CFM shall be as per site requirement complete all as specified and directed.
SAMEER ELECTRICAL SUPPLIER (BID ID -3468625)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3468512)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
84105TenderDocuments.pdf
Tender Documents • 1.16 MB
BOQ_823769.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .