Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.3 L+₹4.1 L (14.4%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹34.7 L+₹6.5 L (22.9%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹36.3 L+₹8.1 L (28.7%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Cat b(i) ,hence Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Mar 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/MAINTENANCE OF DG SETS, AMF PANELS, ALONG WITH FIRE FIGHTING AND OTHER E/M EQUIPMENTS AT KALINA AND COTTON GREEN ,MADH ISLAND AREA UNDER AFS MUMBAI AND REPAIR /REPLACEMENT OF STREET LIGHT AND OTHER MISC WORKS AT AFS MADHISLAND UNDERGE AF THANE
2022_MES_508011_1
8148/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹80,000
Yes
9 May 2022
14 Feb 2022
15 Mar 2022
14 Feb 2022
14 Mar 2022
2 Mar 2022
14 Feb 2022 - 2 Mar 2022
Amount
Annual Maintenance Contract for DG Set 250 KVA, Make - Crompton Greaves, through authorised service agency of OEM , Location :(DG SET -1, Near Library Area AFS Madh) complete all as directed by Engineer-in-Charge Note :- Spares required for above maint will be measured and paid separately under relevent items and the AMC involving the following scope of works :- (I) Scope of works :- (a) Check the sample of coolent concentration (b) Check the fan belt for tension and replace if needed. (c ) Check exhaust condensate drain and remove any debris or dust. (d) Examine the charge level of batteryand check for any loose connection and de-scale carbon deposits if any on terminals and application petroleum jelly. (e) Check the air cleaner components and clean the dirt with air pressure. (f) Check and adjust the voltage level of the battery charger.(g) Drain out the water from the container of the bottom of the filter housing and fuel tank. (h) Check the control panel wiring, Instrumentation, contacts fuses, etc. (j) Check the specific gravity of battery every month and condition of Plates once in three months. (k) Check the serviceability of safety controls of Engine.(l) Checking of all electricalconnectons for its proper tightness. (m) Check AVR connections & power cable connections for tightness. (n) Check RPM/Frequency and adjust it. (o) Checking of Load balancing of alternator/AMF panel output (p) Check the condition wire breaded / nonbreaded hoses of engine. (II) In addition to above the following checks will be carried out by contractor in six monthly :- (a) Replace the fuel filter and oil filter. (b) Clean the crank case breather.(c) Check the radiator hoses.
Srl Item No 1.01 Contd../- (III) In addition to above the following checks will be carried out by contractor annually :- (a) Greasing of Alternator Bearing (b) Cleaning the diesel tank. (c) Check the installation. (d) Checking of exhaust back pressure. (e) Checking of temperature of exhaust. (f) Check the performance of radiator. (IV) Unit rates quoted shall be inclusive of the following : (a) Checking of all rotary and stationery parts of engine and adjust/repair the defects as required for satisfactory running of DG set. (b) Cleaning and refitting the air cleaner. (c) Cleaning of fuel filter assembly and replacement of filter element along with rubber 'O' ring. (d) Replacement of 'V' belt for driving radiator fan/ water Pump/Battery charger alternator with proper adjustment. Repair to nozzle by replacement plunger & spring valves. Replacement of high pressure stainless steel tubing not less than 1 m length from FIP to nozzle including Benjoo bolts, copper washer etc. Replacement of upper gasket kit. (e) Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure. (f) Drain out the lub oil and refill new oil after proper cleaning. (g) Checking and adjustment of tappet clearance. Note :- (i) In case of any breakdown service engineer shall attend the break down immediately and make the DG Set Serviceable within 24 working hrs. (ii) Repair, if any must be carried by Contractor through authorised workshop of original manufacturer and Payment will be made to the contractor on Produce of Original Manufacturer's Bills/vouchers.
Ditto --all as per item No -1 here-in-before but for 125 KVA DG Sets Make:- Kirloskar ( Power House DG -1) complete all as directed by Engineer-in-Charge
Ditto --all as per item No -1 here-in-before but for 125 KVA DG Sets Make:- Kirloskar ( Power House DG-2) complete all as directed by Engineer-in-Charge
Ditto --all as per item No -1 here-in-before but for 82.5 KVA DG Sets Make:- Kirloskar ( AFNET SUB station DG -1) complete all as directed by Engineer-in-Charge
Ditto --all as per item No -1 here-in-before but for 82.5 KVA DG Sets Make:- Kirloskar ( AFNET SUB station DG-2) complete all as directed by Engineer-in-Charge
Ditto --all as per item No -1 here-in-before but for 62.5 KVA DG Set Make:-Crompton Greaves, ( Near SMC Hall station DG -1 ) complete all as directed by Engineer-in-Charge
Draining out the old sludgs oil from the DG set and replace with new oil as recommended by Mfg complete all as directed by Engineer-in-Charge. NOTE : Draining out of Oil shall be done twice in year each time reffiling/Top up )
Supply and fixing for Industrial Battery of 12 Volt,180 AH capacity suitable for 82.5 to 250 KVA DG Sets heavy duty, 25 plates includidng removing existing unserviceable battery from existing places and cleaning of battery terminals and clamps properly and refixed and reconnected complete all as directed by Engineer-in-Charge.
Servicing of AMF Panel suitable for 12.5 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs all as directed by Engineer in Charge. NOTE :- Spare parts shall be measured and paid sepretely in resppective item of this schedule if required.
Supply only for LED type Indicator indication lamps R,Y,B) complete all as directed by Engineer-in-Charge
Supply only for Push Buttons with element complete all as directed by Engineer-in-Charge Make : L&T or Telimechanic
Supply only for Control relay 9/11 pin 12 /24 volt DC of suitable for 62.5 KVA to 125 KVA DG Set complete all as directed by Engineer-in-Charge.
Supply only for AMF controler for 250 KVA complete all as directed by Engineer-in-Charge Make : Greaves Crompton
Supply only for CT of ratio upto 150 / 5 10 VA burdan complete all as directed by Engineer-in-Charge Make:- AE/NIPPON
Supply only for HRC fuse 200 Amp complete all as directed by Engineer-in-Charge. Make : L&T/SEIMENS
Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 4 sq mm for control wiring complete all as directed by Engineer-in-Charge
Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 2.5 sq mm for control wiring complete all as directed by Engineer-in-Charge.
Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 1.5 sq mm for control wiring complete all as directed by Engineer-in-Charge.
Material and Labour in repairs of Temperature gauge complete all as directed by Engineer-in-Charge.
Supply only for Oil Pressure Guage 0-10 Bar complete all as directed by Engineer-in-Charge.
Supply only for Digital Frequency meter complete all as directed by Engineer-in-Charge.
Supply only for DC Volt meter 0 to 20 volt complete all as directed by Engineer-in-Charge
Supply only for DC Ammeter 0 to 20 Amp complete all as directed by Engineer-in-Charge.
Supply only for Excitation coil for 250 KVA DG set complete all as directed by Engineer-in-Charge.
Supply only for AVR card for 125 KVA DG set complete all as directed by Engineer-in-Charge.
Supply only for AVR card for 82.5 KVA DG setcomplete all as directed by Engr-in-charge.
Supply only for AVR card for 62.5 KVA DG set complete all as directed by Engineer-in-Charge.
Material and Labour for servicing of Turbo charger including Replacemnt of Turbo charger kit for capacity 250KVA /125 KVA/82.5KVA/62.5KVA complete all as directed by Engineer-in-Charge.
Material and Labour in Servicing of Self Starter 24 Volt DC for 250 KVA DG Set, dissmantling complete,& replacement of solenoid field coils. cleaning the cummutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as directed by Engr-in-charge.
Ditto all as per item No 11.00 here-in- before but for capacity 125 KVA DG set complete all as directed by Engr-in-charge.
Ditto all as per item No 11.00 here-in- before but for capacity 82.5 to 62.5 KVA DG set complete all as directed by Engr-in-charge. .
S&F, in repairs , self starter 12 volt DC for 62.5 to 82.5 KVA DG set including all accessories complete all as directed by Engr-in-charge.
Material and Labour for in repairs of Feed Pump for Aquastic DG set for capacity 62.5 to 82.5 KVA complete all as directed by Engr-in-charge. Make -Kirloskar
Dis-connecting the alternator from the engine of capacity 250 KVA by removing the coupling & outgoing cable transporting the alternator to authorized maintenance service center for repairsCleaning the armature, applying one coat of varnish and heating and assembling the alternator at workshop and testing at NO load, transporting the same to the site , re-connecting the alternator to the engine after proper alignment including testing and commissioning complete all as directed by the Engr-in-Charge.
Ditto all as per item No 16.00 here-in- before but for 125/ 82.5 KVA DG Sets complete all as directed by Engr-in-charge..
Draining out the Water from engine of capacity 250KVA the radiator , dis-mantling the leaking radiator assembly from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leakages, transporting the same to the site and re-fixing and testing complete in the presence of Engr-in-charge.
Ditto all as per item No 18.00 here-in- before but for 125 / 82.5 KVA DG Set complete all as directed by Engr-in-charge.
Material and Labour in taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zink primer for out side silencer pipe & providing self adjestive Asbasto Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of syenthetic enameled paint for expose portation of exhaustcomplete all as directed by Engr-in-charge..
Material and Labour scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint of approved shade and writing of MES/SM No on the set all as directed of capacity 250/125/82.5/62.5 KVA complete all as directed by Engr-in-charge..
Supply olny solenoid Switch 12 Volt DC complete all as directed by Engr-in-charge. Make: Kirloskar
Supply only Battery terminal Heavy duty made of brass with nut and bolt including washers suitable for 12 volt DC battary complete all as directed by Engr-in-charge.
Supply only Radiator Hose pipe as per existing set for 62.4/82.5 KVA complete all as directed by Engr-in-charge.
Supply only Door hinges assembly for Aquastic DG set complete all as directed by Engr-in-charge.
Supply only Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC complete all as directed by Engr-in-charge.
Supply only Ignition Switch for capacity up to 250,125,82.5 KVA DG set complete all as directed by Engr-in-charge...
Supply only solenoid Switch 24 Volt DC for 125/250 KVA DG Set as per existing complete all as directed by Engr-in-charge.
Supply only Coolant premix as manufafacture recommendations and required for top up for Accostic DG set complete all as directed by Engr-in-charge.
Supply only refilling of distilled water for top up battary 12 volt DC complete all as directed by Engr-in-charge.
Supply only Air Filter inside & out side for capacity 250 KVA DG Set complete all as directed by Engr-in-charge.
Supply only Primary Fuel Filter for capacity 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Secondray Fuel Filter for capacity 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Lubricating Oil Filter for capacity 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Fuel pipes with benjo bolt and washers.For capacity 250 KVA DG set complete all as directed by Engr-in-charge.
Supply ony V- Belt as per existing size for capacity 250 KV DG set complete all as directed by Engr-in-charge.
Supply only Air Filter inside & out side for capacity up to 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Primary Fuel Filter for capacity up to 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Lubricating Oil Filter for capacity up to 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Primary Fuel Filter for capacity for 62.5/82.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only Secondary fuel filter for capacity for 62.5/82.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only lubricating Oil Filter for capacity 62.5/82.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only super by pass oil filter for 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Fuel pipes for capacity up to 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Vee Belt as per existing size for capacity up to 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only fuel governing controler for 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Coolant hose set suitable for 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Coolant hose set suitable for 125 KVA DG set complete all as directed by Engr-in-charge.
Supply only Coolant hose set suitable for 82.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only Coolant hose set suitable for 62.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only Fuel hose set suitable for 250 KVA DG set complete all as directed by Engr-in-charge.
Supply only Fuel hose set suitable for 82.5 KVA DG set complete all as directed by Engr-in-charge.
Supply only Fuel hose set suitable for 62.5 KVA DG set complete all as directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dence soil complete all as specified and directed .
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
Supply spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand all as specified.
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches and relaying after cable laying in trenches all as specified and directed
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection all as directed by Engineer – in – Charge.
Dismantling and Taking down L.T. under ground armored PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed.
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed.
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 25 sq mm 3.5 Core complete all as specified and directed.
Supply and fixing in repairs/Replacement of of the undermentioned items to be incorporated in street light fittings complete all as specified and directed by Engineer-in-charge
(a) LED Driver for 1 x 45 watt LED street light complete of make -Crompton/Bajaj/Havells or as per sample.
(b) LED Driver for 1 x 60 watt LED street light complete of make -Crompton/Bajaj/Havells or as per sample.
(c) LED Driver for 1 x100 watt LED flood light complete of make -Crompton/Bajaj/Havells or as per sample.
(d) LED Driver for 1 x200 watt LED flood light complete of make -Crompton/Bajaj/Havells or as per sample.
Supply and fix in repairs LED street light fittings 60 Watts Pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make Crompton Cat No. LSTN-60-CDL or equivalent of make Bajaj / Havellscomplete all as specified and as directed
Supply and fix in repairs LED street light fittings 30 Watts Pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make Crompton Cat No. LSTN-30-CDL or equivalent of make Bajaj / Havellscomplete all as specified and as directed
S&F copper cable flexible PVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engr-in-Charge
Supply & Fix in Replacement of GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clamp of size 40x5 mm with necessary nut bolts & washers and applying two coats of synthetic enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed.
Material and Labour for painting of steel tubular pole 9 mtr long with one coat of aluminium paint including preparation old surface with scrapping of steel tubular poles Including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed.
Material and Labour for painting of Pre-stressed concrete pole 9 mtr long with one coat of white colour weatherproof snowsum paint including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed.
Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA, etc including suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directed Make :- SINTEX / NATIONAL / NATRAJ.
Material and Labour for cement concrete Type C2 1:3:6 (40 mm graded aggregate of 150 mm thickness in foundation filling and mass concrete for filling of road cutting and making good for disturbed surfaces complete all as specified and directed by Engr-in-charge.
Material and labour for lowering of LED light fiitings mounting ring 20 Mtr to 30 Mtrs height carefully with help of highly skilled electrician and labours to mannually/electrically, Servicing Repair and replacement of spares of forward/reverse operation induction motor 3 phase 415 volts 2 HP capacity including greasing and oiling. Servicing of forward/reverse operation Gear box including greasing and oiling, dismantling and taking chain of motor to gear box, takindown unserviceable LED Light fittings and replacement of Suitable drivers of existing capacity/ Make its serviceable,supply and replace wire rope for lift side for suitable gauges/size,replacement of time with power contactor three phese 415 volts AC 32 Amps capacity, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places complete all as pspecified and directed by Engineer-in-charge
Supply only LED flood light fitting 200 Watts Pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make or equivalent of make Bajaj / Havellscomplete all as specified and as directed
AMC for DG Set 82.5 KVA, Make - Kirloskar, through authorised service agency of OEM , Location : Two Nos at Kalina AFNET Note :- Spares required for above maint will be measured and paid separately under relevent items and the AMC involving the following scope of works :- (A) Scope of work :- (a) Ckeck the sample of coolent concentration (b) Check the fan belt for tension and replace if needed. (c ) Check exhaust condensate drain and remove any debris or dust. (d) Examine the charge level of batteryand check for any loose connection and de-scale carbon deposits if any on terminals and application jelly. (e) Check the air cleaner componenets and clean the dirt with air pressure. (f) Check and adjust the voltage level of the battery charger. (g) Drain out the water from the container of the bottom of the filter housing and fuel tank. (h) Check the control panel wiring, Instrumentation, contacts fuses, etc. (j) Check the specific gravity of battery every month and condition of Plates once in three months. (k) Check the serviceability of safety controlls of Engine. (l) Checking fo all electricalconnectons for its proper tightness. (m) Check AVR connections & power cable connections for tightness. (n) Check RPM/Frequency and adjust it. (o) Checking of Load balancing of alternator/AMF panel output (p) Check the condition wire breaded / nonbreaded hoses of engine. (q) Replace the fuel filter and oil filter. (r) Clean the crank case breather. (s ) Check the radiator hoses. (t) Greasing of Alternator Bearing (u) Cleaning the diesel tank.(v) Check the installation. (w) Checking of exhaust back pressure. (x) Checking of temperature of exhaust. (y) Check the performance of radiator. (B) Unit rates quoted shall be inclusive of the following : (a) Checking of all rotary and stationery parts of engine and adjust/repair the defects as required for satisfactory running of DG set. (b) Cleaning and refitting the air cleaner.
Srl Item No 77.01 Contd../- (c) Cleaning of fuel filter assembly and replacement of filter element along with rubber 'O' ring. (d) Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure. (e) Drain out the lub oil and refill new oil after proper cleaning. Note :- (i) DHPP required for testing will be supplied by the Department under sch 'B' for free for filling. (v) In case of any breakdown service engineer shall attend the break down immediately and make the DG Set Serviceable within 24 working hrs. (ii) Repair, if any must be carried by Contractor through authorised workshop of original manufacturer and Payment will be made to the contractor on Produce of Original Manufacturer's Bills/vouchers.
All as per ser item No 77.01 here- in- before but for DG Set 75 KVA, qty - 04 Nos make:- Kirloskar , Location : LOS 765 & AFNET CG
All as per ser item No 77.01 here- in- before but for DG Set 63 KVA, qty - 02 Nos make:- Kirloskar , Location : SNCO's Mess & Sion Phase-i
All as per ser item No. 77.01 here- in- before but for DG Set 40 KVA, qty - 03 Nos make:- Kirloskar , Location : Kalina Campus & 121 HF
All as per ser item No. 77.01 here- in- before but for DG Set 30 KVA qty - 01 No make:- Kirloskar , Location : DSC Mess, Santacruz
All as per ser item No. 77.01 here- in- before but for DG Set 25 KVA qty - 01 No make:- Kirloskar , Location : CG PH
All as per ser item No. 77.01 here- in- before but for DG Set 15 KVA qty 3 Nos make:- Kirloskar , Location : LOS, Kalina Campus & cg
Draining out the old slugs oil from the DG set and replace with new oil as recommended by Mfg. NOTE : Draining out of Oil shall be done twice in year each time reffiling/Top up will be measured & paid seperataly.
Disconnecting old unserviceable battery 12 Volts DC upto 180 AH from Engine & transporting to work shop for refilling electrolite, distilled water, checking of sp gravity complete & initial charging of the battery for 48 hours min, transporting back to site , reconnecting up complete all as directed by EIC at site
Servicing of AMF Panel suitable for 15 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs all as directed by Engineer in Charge. NOTE :- Spare parts shall be measured and paid sepretely in respective item of this schedule if required.
M&L for in replacement MCB SP 6 amp AC/DC
M&L for in replacement LED type Indicator
M&L for in replacement Control relay 9/11 pin 12 /24 volt DC Make : PLA/AMRON
M&L for in replacement Micro processor unit for automatic and manual function as specified Make : Narendra Electrical /Kirloskar.
M&L for in replacement Contactor four pole 165 amp coil voltage 230 volt AC Make : TELE MECHANIC (C&S) /SCHNIDER/HPL
M&L for in replacement Contactor Type ML-4. Make:- L&T
M&L for in replacement Contactor Type ML-2. Make:- L&T
M&L for in replacement Change over switch four pole 63 Amp including reconnecting of existing incming & outgoing cables with proper brass glands & lugs. Make : STANDARD/HAVELLS/HPL
M&L for in replacement Change over switch 100 Amp four pole as par existing Make : STANDARD/HAVELLS/HP
Supply and fix in repairs onload change over switch complete in sheet steel enclosure and connecting up, mounting on wall / floor of rating 100 Amps TPN 415 Volts
M&L for in replacement MCB type change over switch four pole 63 Amp . Make : STANDARD/HAVELLS/HP
M&L for in replacement CT of ratio upto 150 / 5 10 VA burdan Make:- AE/NIPPON
Servicing of DG Manual Panel suitable for 15 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, replacement of control fuses / MCBs all as directed by Engineer in Charge. NOTE :- Spare parts shall be measured and paid sepretely in resppective item of this schedule if required.
M&L for in replacement Fault Indicator Control Relay Model No SU 01 of RB Electronics of Kirloskar
M&L for in replacement Fault Indicator Control Relay Model No KRB 101 of RB Electronics of Kirloskar
M&L for in replacement Temperature gauge
M&L for in replacement Oil Pressure Guage 0-10 Bar
M&L for in replacement Digital Frequency meter Make -NIPPON/CONSVER
M&L for in replacement DC Volt meter 0 to 30 volt
M&L for in replacement DC ammeter 0 to 2 amp
N&L for in replacement Excitation coil for 75 KVA DG SET
M&L for in replacement AVR card for 75 KVA DG SET
M&L for in replacement AVR card for 15 KVA DG SET
M&L for Servicing of Self Starter 12/24 Volt DC for 75KVA DG Set, dismantling complete,& replacement of solenoid field coils. cleaning the cummutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as directed by Engineer-in-charge
Ditto as Srl Item No 112.00 above but for capacity for 15 KVA DG SET
M&L for in replacement self starter 12 volt DC for 75 KVA DG SET including all accessories completeall as directed by Make : LUCAS
M&L for in replacement self starter 12 volt DC for 15 to 40 KVA DG SET including all accessories completeall as directed by Make : LUCAS
M&L for in replacement oil Feed Pump for Aquastic DG SET for capacity 15 to 75 KVA Make -KIRLOSKAR
M&L for in replacement alternetor for battary charging 12/24 volt DC complete with all accessories Make : LUCAS
Draining out the Water from the radiator, dis-mantling the leaking radiator assembly complete from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leaks, transporting the same to the site and re-fixing and testing complete in the presence of Engineer-in-charge. for Capacity 75 KVA
Ditto as Srl Item No 118.00 above but for 15 to 25 KVA DG Set.
M&L for Taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zink primer for out side silencer pipe & providing self adjestive Asbasto Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of syenthetic enameled paint for expose portation of exhaust; all as directed.
M & L for scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint over a coat of red oxide of approved shade and sign writing of SM / MES No on the set all as directed of capacity 75 KVA
Ditto as Srl Item No 121.00 above but for 15 KVA to 40 KVA DG Set.
M&L for in replacement solenoid Switch 12 Volt DC. Make: LUCAS
M&L for in replacement Stopping relay 24 volt DC. Make:- Lucas
M&L for in replacement Anti - Vibrating Pad suitable for 15 to 40 kVA DG Set.. Make:- LOVE JOY/DON LOP
M&L for in replacement Ignition Switch for capacity up to 75 KVA DG SET.
M&L for Coolant as required for top up. Make : MAX Supar Cool for Accostic DG SET.
M&L for Refilling of distilled water for top up battery 12 volt DC.
M&L in replacement Fuel pipes with benjo bolt and washers.For capacity 75 KV DG SET.
M&L for in replacement Heavy duty Battery terminal for 12 volt DC battary.
M&L for in replacement Radiator Hose pipe as per existing Set of 2
M&L for inreplacmennt Door Lock Assembly with key for Acauastic DG SET.
M&L for in replacement Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC
M&L for in replacement Solenoid coil for capacityy up to 75 KVA DG SET. Make:- Kirloskar
M&L for in replacement Rubber Coupling with nut bolt & washer in between Alternator& Engin & up to 75 KVA DG SET
M&L for in replacement Battery lead with lug as per existing length & size for capacity up to 75 KVA DG SET
M&L in replacement Air Filter inside & out side for capacity 15 kVA to 75 KVAR DG SET
M&L in replacement Primary Fuel Filter for capacity 75 KV DG SET.
M&L in replacement Secondray Fuel Filter for capacity 75 KV DG SET.
M&L in replacement Lubricating Oil Filter for capacity 75 KV DG SET.
M&L in replacement V- Belt as per existing size for capacity 75 KV DG SET
M&L in replacement Diesel pipe PVC Flexible up to 12 mm for capacity 75 KV DG SET.
M&L in replacement Air Filter inside & out side for capacity up to 40 KV DG SET.
M&L in replacement Primary Fuel Filterfor capacity up to 40 KV DG SET.
M&L in replacement Secondray Fuel Filter for capacity up to 40 KV DG SET.
M&L in replacement Lubricating Oil Filterfor capacityy up to 40 KV DG SET.
M&L in replacement Fuel pipes with benjo bolt and washers. For capacity up to 40 KV DG Set
M&L in replacment V- Belt as per existing size for capacity 15 to 40 KV DG SET
M&L in replacement Diesel pipe PVC Flexible up to 12 mm for capacity up to 40 KV DG Set.
M&L PVC / FRP chequered plates 10 mm and over cut to shape, square / notched ( ordinary and counter sunk , forming holes without any attachment in Quality 'A' all as specified by Engineer-in-Charge Make : Sintex
M & L for testing of APFC panel for proper functioning in manual & auto mode,re-wiring the burnt out wires, and replacing the unserviceable spares and testing complete all as directed by engineer-in-charge. NOTE :- Spares like power capacitors, load managers, push button, contactors, ammeter, voltmeter, MCBs will be measured and paid seperatly under respective item of sch'A'
M&L for replace to acoustic canopy of size appx 3 mtr X 1.2 Mtr X 1.5 mtr of 75 kVA DG set incl painting matching with the existing color code and coushion pads complete all as specified and directed by Engr-in-Charge
Ditto as per Srl Item No 152.00 above but of size appx 2 mtr X 1.2 Mtr X 1.5 mtr of 15 kVA DG set incl painting matching with the existing color code and coushion pads complete all as specified and directed by Engr-in-Charge
M & L in replacement of Genset controller for 75 KVA
M & L in replacement Voltage Monitoring Relay(VMR)
M & L in replacement OEN Relay
M & L in replacement Timer for controlling voltage shifting from no load to full load complete all as specified and directed by Engr-in-charge
M & L in replacement water pump of capacity 75 KVA for DG set
M & L in replacement water pump of capacity 30 KVA for DG set
M & L in replacement Coolant Hose set for 75 KVA
M & L in replacement Coolant Hose set for 30 KVA- 40 KVA
M & L in replacement Fuel hose set for 75 KVA
M & L in replacement Fuel hose set for 30 KVA-40 KVA
M & L in replacement Air filter element for 75KVA
M & L in replacement Air filter element for 30 KVA- 40 KVA
Atharva Enterprises
PHOENIX ELEVATOR INDIA PRIVATE LIMITED
M/s Bhagirathi Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .