| 1 | L1₹12.7 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹15.0 L+₹1.3 L (9.66%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹17.3 L+₹3.7 L (27.0%)Rejected-Finance 10 WARD NO 18 PLOT NO 34 KAMDENU FURNTIURE SIKAR RAJASTHAN 332025 | SIKAR | RAJASTHAN | 332025 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹19.9 L+₹6.2 L (45.5%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹20.9 L+₹7.2 L (52.9%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/s Prakash Enterprises L2 | Vijeta Solutions L4 | OMVIN ENTERPRISES LLP L1 | Ruchi enterprises L3 | ACR ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed by Engr-in-Charge. | 763 | Per Point | 2 ₹1,526 Lowest | 30 ₹22,890 | 10 ₹7,630 | 9 ₹6,867 | 30 ₹22,890 |
| 2.00 | M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
Note:- All accessories likes modular top cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. | 89 | Per Point | 300 ₹26,700 | 296 ₹26,344 Lowest | 300 ₹26,700 | 300 ₹26,700 | 450 ₹40,050 |
| 3.00 | All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge. | 80 | Per Point | 300 ₹24,000 | 295 ₹23,600 Lowest | 300 ₹24,000 | 300 ₹24,000 | 450 ₹36,000 |
| 4.00 | All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge. | 30 | Per Point | 100 ₹3,000 Lowest | 185 ₹5,550 | 100 ₹3,000 Lowest | 200 ₹6,000 | 100 ₹3,000 Lowest |
| 5.00 | All as per ser items No. 2.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge. | 1 | Per Point | 250 ₹250 | 254 ₹254 | 350 ₹350 | 200 ₹200 Lowest | 470 ₹470 |
| 6.00 | All as per ser items No. 2.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge. | 20 | Per Point | 300 ₹6,000 Lowest | 455 ₹9,100 | 400 ₹8,000 | 300 ₹6,000 Lowest | 550 ₹11,000 |
| 7.00 | M and L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/fan/exhaust point controlled by one, one way switch 06 Amps complete all as specified and directed by Engr-in-Charge.
Note - All accessories likes modular top cover plate, Metal flush box, screws, as applicable will be included in quoted rates. | 140 | Per Point | 300 ₹42,000 Lowest | 325 ₹45,500 | 300 ₹42,000 Lowest | 300 ₹42,000 Lowest | 400 ₹56,000 |
| 8.00 | All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge. | 45 | Per Point | 300 ₹13,500 Lowest | 325 ₹14,625 | 300 ₹13,500 Lowest | 300 ₹13,500 Lowest | 400 ₹18,000 |
| 9.00 | All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge. | 55 | Per Point | 100 ₹5,500 Lowest | 225 ₹12,375 | 100 ₹5,500 Lowest | 300 ₹16,500 | 100 ₹5,500 Lowest |
| 10.00 | All as per ser items No. 7.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge. | 90 | Per Point | 300 ₹27,000 Lowest | 375 ₹33,750 | 350 ₹31,500 | 300 ₹27,000 Lowest | 500 ₹45,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Jul 2025, 6:00 pmClosed
GE E/M RR HOSPITAL, DELHI CANTT-10
GE E/M RR HOSPITAL, DELHI CANTT-10
REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION and CONNECTED WKS SUCH AS SUBMAIN, MCBS, DBS AT COY AREA UNDER GE E/M RR HOSPITAL DELHI CANTT-10
2025_MES_713288_1
GE/H/T-17/ 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSPITAL, DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSPITAL, DELHI CANTT-10
₹50,000
Yes
29 Aug 2025
9 Jun 2025
9 Jul 2025
9 Jun 2025
7 Jul 2025
23 Jun 2025
Amount
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed by Engr-in-Charge.
M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge. Note:- All accessories likes modular top cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
M and L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/fan/exhaust point controlled by one, one way switch 06 Amps complete all as specified and directed by Engr-in-Charge. Note - All accessories likes modular top cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 7.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in PVC casing & caping including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box flush/surface mounted, modular white cover plate with frame, blanking plate, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as specified and directed by Engr-in-Charge. Note - All accessories likes modular top cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per ser items No. 11.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 11.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 11.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 11.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Switch 1 way 16 A, 1 Module, Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Socket 6 / 16 A - 2/3 Pin combined 2 module,Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Switch 1 way 6 /10 A, 1 Module,Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module, Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of modular switch, 06 amps two way,SP,one module 230 volts AC,Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular fan regulator 4 step type, 100W 2 Module complete all as specified and directed by Engr-in-Charge.
S & F in repair of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top 15/16 Amp, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc,complete all as specified and directed by Engr-in-Charge.
S & F in replacement in repair of surface/wall mounted 20W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The electronic driver used shall have a power factor ≥0.90 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV complete all as specified and directed by Engr-in-Charge.
S & F in replacement in repair of surface/wall mounted 36W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The electronic driver used shall have a power factor ≥0.90 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV complete all as specified and directed by Engr-in-Charge.
S & F in replacement in repair of LED Lamp Round shape 12 watt, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply of surface/wall mounted 10W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.90 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of recessed 36 W LED 2X2 panel backlit type only. Luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting in office areas. The LEDs used should have CRI ≥ 80 and CCT 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire system efficacy of ≥ 120 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs. The electronic driver used shall have a power factor ≥0.90 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 3.5KV complete all as specified and directed by Engr-in-Charge.
Supply and fix Building security light with high efficient high power LED street light 35 watt with inbuilt daylight sensor which switches ON/OFF automatically in the absence/presence of sunlight with lens with pressure die cast aluminium housing and enclosed with toghened glass IP-66, and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc including bracket suitable for fittings, clamps, fasteners and all other fixing accessories complete all as specified and directed by Engr-in Charge.
Taking down sub main 4/6 Sqmm complete all as specified and directed by Engr-in-Charge.
M&L in replacement Sub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
M&L in replacement Sub main wiring concealed with 6 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 6 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
Supply and fix in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recessed on wall, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as specified and directed by Engr-in-Charge.
All as per item ser no 33.00 here-in-before but 8 Way Distribution board complete all as specified and directed by Engr-in-Charge.
All as per item ser no 33.00 but 4 Way Distribution board complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recesses on wall, VTPN 12 way, 240 volts with bus bar rating 415 Amps, dust and vermin proof suitable for incorporation of MCCBs 4 pole, MCB TPN and MCBs etc and making all necessary connections complete all as specified and directed by Engr-in-Charge.
All as per srl item no 36.00 here in before but of VTPN 08 way type complete all as specified and directed by Engr-in-Charge.
M&L in replacement MCB 6 to 32 Amp, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB, SPN type of 40 to 63 amps capacity, 240V, 10 KA with all connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB, SP type of 40 amps capacity, 240V, 10 KA with all connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 415V,4 pole 160 Amps, 36 kA, adjustable with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement in repair of electronic tamper proof meter of cap 10 to 60 Amp, connection of incoming wire and outgoing connection with wire of proper colour code of 6 sqmm upto DB and sealing the meter with sealing wire & sealing lead and depositing the same into MES Storeyard complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.50 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.75 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 1.00 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 2.50 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 4.00 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Plug Top 15 Amps, 3 Pin complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Electric bell, Ding-Dong type, AC 230 Volts, Single Phase complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Wall light 1x35W GLS/ 1x5W LED of premium quality dimmable lamp of base - GU10 having versatile lighting option complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Wall decorative light 3x5W LED of premium quality dimmable lamp of inbuild LED base having versatile lighting option complete all as specified and directed by Engr-in-Charge.
M/s Prakash Enterprises (BID ID -3339159)
Ruchi enterprises (BID ID -3340628)
Vijeta Solutions (BID ID -3337463)
ACR ENTERPRISES (BID ID -3340316)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .