Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC 5 9 35 HAZARHAT KALITALALANE HOWRAH 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | L1 | Accepted-AOC Quoted lowest bid | |
| 2 | Not Admitted-Finance 0 BHOLA BABU H B ROAD BHARALUMUKH MACHKOWA GUWAHATI KAMRUP ASSAM 781009 | KAMRUP METRO | ASSAM | 781009 | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹5.2 L
EMD Value
₹10,450
Closing Date
12 Jan 2022, 2:30 pmClosed
CEO HDA
Office of the Chief Executive Officer Haldia Development Authority City Centre P.O. Debhog Haldia 721657 Dist Purba Medinipur
Supply Installation Testing and Commissioning of 12 Mtr Mini Mast (2 Nos) with LED Flood lights for area illumination of Paikpari Rural Hospital campus at Kolaghat under Kolaghat Panchayet Samity
2021_HDA_357934_1
09/HDA/EC ELECT/2021 2022
Open Tender
Electrical Work/ Equipment
Item Rate
90 days
Haldia
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,450
Haldia
11 Feb 2022
28 Dec 2021
17 Jan 2022
28 Dec 2021
12 Jan 2022
3 Jan 2022
30 Dec 2021
Items
Supply & delivery of LED Flood light of following specification: a) 150 W for each set (Maximum). b) System Efficacy of the Luminaries should have minimum 15000 lumens. c) The fixture shall have Ingress Protection of IP 66 Rating for both for Optical & Electrical Compartments. d) Luminaries should consist of Universal Voltage Driver to handle wide operating voltage range from 130-270V AC and frequency range of 50+/-3% Hz. e) Driver shall have high efficiency and have inbuilt safety features like over voltage , short circuit , over load , thermal protection and reverse polarity protection. f) Luminaries should be powder coated and housed in a single piece Pressure die cast non-corrosive Aluminium alloy enclosure with optimal fins for Heat Sink Mechanism. g) Rated Operating Temperature should be 0 deg to +55 deg C with a relative humidity of 10-95% RH. h) Luminaries shall have five (5) years replacement warranty period from actual date of completion of work including driver/control gear, LED etc. (Make & Model No.: Bajaj-BJFL 150W LED White/ Havells-JETAVALOURFL 150W LED 757 PINTNALTG/ Crompton-LFLN-150-CDL/60-M/ Philips- BVP 192 LED 160 CW NB FG PSU GR).
Supply, delivery including transportation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal/polygonal Mini-mast (single section) with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 6 nos. of non integral flood light fittings (with luminaries mounting plate and provision of passing wire) along with G I nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. The rate should include testing at your works, all taxes and delivery the materials at site. (Make:UTKARSH INDIA LTD/TRANSRAIL LIGHTING LIMITED/BAJAJ ELECTRICALS LTD).
Erection, Testing and Commissioning of the Mini Mast 12 Mtr. with modern engineering practice (Excluding the cost of RCC foundation).
Supply and fixing of SPMCB "B" Curve 1 Amp with ISI marked to be placed on a din channel of Pole and supply and fixing of Terminal connector at the suitable location of the pole.
Supply and fixing of Pole numbering Sticker (5" X 3") at the street light pole.
Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire wiyh the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole).
Supply and delivery of 1.1 KV grade 4 C X 16 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1 with latest amendment if any. The cable should have ISI mark
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/tubular Pole, feeder pillar box etc.
Laying of GI pipe by Jack push method through micro tunneling 2-3M deep under black top surface with excavation of double earth pit 1400×600×3000 mm on hard soil, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe)
Supply, Delivery, Installation including foundation of Feeder Pillar Box of size 1000 X 1000 X 400 mm made of 4 mm thick CRCA steel sheet with zinc powder coated outdoor type with top canopy, sides having lovers for ventilation, double door, provision for installation of Single-Phase Meter at right side of the feeder pillar & one DP Main Switch as per direction of engineer-in-charge. Supply and Installation of suitable CCMS (Centralized Control and Monitoring System) in the above Feeder Pillar Box inclusive of transportation, loading/ unloading, P&F, Handling, etc., with Micro process based controlled system with necessary MCB's, MCCB, timer, contactor, connectors and provision for energy meter etc., complete for finished item of work and as per Specifications.
Fixing only Flood light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
Connection of luminaries with 3C X 4 Sqmm PVC insulated FR copper conductor through 12 mtr. Mini Mast from looping box to light fittings as required.
RCC Foundation for 12mtr high mast as per the enclosed drawing and details schedule.
Connecting the equipments to earth bus bar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (ii) No. 6 SWG.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (2.8 sqm per panel x 1+1.54sqm mini mast x 2).
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. (2.8 sqm per panel x 1+1.54sqm mini mast x 2). Two coats.
Laying of one No. cable upto 35 Sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed, for looping cable.
Laying only Cable upto 50 sq.mm through existing RCC/Hume/ GI /HDPE Pipe/open masonry trench for single, 2, 3, 3½ & 4 core
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i) 4 core X 16 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. i) 4 core X 16 sqmm
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Earthing with 50 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, For Soft Soil.
Excavation of soil for installation of Earth Electrode and filling & ramming. (1Cu mtr. X3).
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. DP 10Amps
Providing and fixing typical citizen information board constructed with BFS, PCC, 250 mm & 125 mm brick wall (1:4) with necessary 15 mm thick plastering (1:4) & rule pointing, including supply & fixing of white marble stone (1100mm X 800mm X 18mm) with black colour engraved lettering as per the enclosed drawing.
Supply of HDPE pipe conforming to IS-4984-1985(Dia) [PE-63], 6Kg/Sq.cm(Working Pressure), 50 mm Dia.
Labour for fitting and fixing high density poly-ethilene pipes or P.V.C pipes for below ground work including cost of jointing materials paints etc fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the coast of masonary or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the site engineer-in-charge (Payment will be made on centre line measurement of the total pipeline including specials) (for 50 mm dia).
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .