Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC ADMITTED | |
| 2 | L2₹10.4 L+₹61,015.40 (6.23%)Accepted-AOC | L2 | Accepted-AOC ADMITTED | |
| 3 | L3₹10.7 L+₹89,085 (9.10%)Accepted-AOC | L3 | Accepted-AOC ADMITTED | |
| 4 | L4₹10.7 L+₹95,721 (9.78%)Accepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L4 | Accepted-AOC ADMITTED | |
| 5 | L5₹11.0 L+₹1.2 L (12.7%)Accepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L5 | Accepted-AOC ADMITTED |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
21 Oct 2020, 6:00 pmClosed
GE(A) Barmer
Military Engineer Services Garrison Engineer Army Jalipa Mil Stn Post box No 53 Barmer 344001
REPAIR MAINTENANCE OF STREET LIGHT, SECURITY LIGHT, HIGH MAST LIGHT, LIGHTNING PROTECTION, VOLTAGE STABILIZER AND ITS CONNECTED ITEMS AT JALIPA MIL STN ZONE A AND B AND ASCON NODES UNDER GE (A) BARMER
2020_MES_379999_1
GE(A)/BMR-22 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
GE(A) Barmer
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹20,000
Yes
31 Mar 2021
23 Sept 2020
24 Oct 2020
23 Sept 2020
21 Oct 2020
7 Oct 2020
Amount
Disconnecting and taking down old unserviceable 70/80/125/150 watt SV / MH / MV lamp street light fittings with brackets fixed on HT/LT poles, repairing after cleaning and replacing the un-serviceable parts like Ballast / choke, starters, ignitors, capacitors, holders, lamp etc and refixing / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : - (i) Parts replaced like ballasts / chokes, starters, ignitors, capacitors, holders, lamps, etc shall be measured and paid for as "Supply only" here-in-after. (ii) Cost of replacement of wornout wire of the fittings and connections as per existing size of conductor of the each fittings shall deemed to be included in the rate quoted of this item.
Supply only electronic Ignitor suitable for HPMV/ HPSV /MH fitting of 70/80/125/150 watt
Supply only copper ballast/choke with copper winding for street light fitting of HPSV/MH 150 watt.
Supply only copper ballast/choke with copper winding for street light fitting of HPSV/MH 70 watt.
Supply only MH tubular lamp for street light fitting of 150 watt.
Supply only MH lamp double ended for street light fitting 70 watt
Supply only lamp holder assembly as per existing make suitable for HPSV/MH fitting up to 400 watt
Disconnecting and taking down old unserviceable LED street light fittings with brackets fixed on HT/LT/Street light poles, repairing after cleaning and replacing the un-serviceable parts and refixing / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : -(i) Parts replaced shall be measured and paid for as "Supply only" here-in-after. (ii) Cost of replacement of wornout wire of the fittings and connections as per existing size of conductor of the each fittings shall deemed to be included in the rate quoted of this item.
Supply only Driver for LED 25 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 45 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 60 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 90 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 100 Watt Make :- Bajaj / Havells / CG
Supply only surge protector for LED 25 to 90 Watt Make :- Bajaj / Havells / CG
Disconnecting and taking down LED integrated solar light of make Axxon tech of capacity 12 W to 24W street light fittings with brackets fixed on HT/LT poles, repairing after cleaning and replacing the un-serviceable parts like solar charge controller, sensor, Lithium battery etc., and refixing / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : - (i) Parts replaced like solar charge controller, sensor, Lithium battery etc .,shall be measured and paid for as "Supply only" here-in-after. (ii) Cost of replacement of wornout wire of the fittings and connections as per existing size of conductor of the each fittings shall deemed to be included in the rate quoted of this item.
Supply only solar charge controller 5 Amp for 12 W to 16 W for integrated solar street light Make :- Axxon -12WSCC or equivalent in Philips / C&S
Supply only solar charge controller 10 Amp for 24 W for integrated solar street light Make :- Axxon -24WSCC or equivalent in Philips / C&S
Supply only PIR motion sensor for 170uA for solar street light 12 W to 24 W Make :- Axxon / Philips / C&S
Supply only lithium Ion Battery 11.1V/15.4 AH ( 210mmX70X40mm) for 12W Make :- Axxon / Philips / C&S
Supply only lithium Ion Battery 11.1V/19.8 AH ( 210mmX70X40mm) for 16W Make :- Axxon / Philips / C&S
Supply only lithium Ion Battery 11.1V/ 28.6 AH ( 210mmX70X40mm) for 24W Make :- Axxon / Philips / C&S
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 40 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 40 - CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 45 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 45- CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 60 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 60 - CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of integral compact wide beam 100W LED flood light fiiting, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting and connected with two runs of 2.50 sqmm multi-strand copper flexible wire including taking down unserviceable flood light fitting complete all as specified and as directed. Make : Havells Cat Part No. JETAIRISFLS100WLED757APNBLTG or techno commercially equivalent model of make Bajaj/Philips/CG
Supply, fix ,connecting and testing of Lithium base Energy Efficient integrated solar street light 16 watt in FRP body encases solar PV panel 30/35wp monocrystalline,lithium battery 11.1/12.8V,19.8 AH with built in BMS, High brightness W-LED(120-160 1m / watt) lamp,CRI 80,color temperature 6500K, Micro controller based charge controller cum driver with automatic dimming function,dusk to down operation,LUX output 30-35 (from 5-6 mtr height),working temperature (-)10°c to (+)55°c,weight 8-9 Kg with adjustable MS clamp suitable for pole/wall mounting protection from short circuit, overload,reverse polarity and battery protections including taking down unserviceable light fitting complete all as specified and as directed. Make : Axxon - AXN - 16 watt or techno commercially equivalent model of make Bajaj/Philips/CG
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in deep for foundation of pole, laying of cable etc, and getting out in any type of soil complete all as specified and as directed .
Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and as directed.
Supply and spreading tibba sand in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply and laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1by using 20mm graded crushed stone aggregate as in padestal coping of pole including necessary form work complete all as specified and as directed.
Supply, laying, jointing and testing PVC insulated,unsheathed,multi-stranded,two core,aluminium conductor cable 4.00 sqmm in two runs through and including 25 mm dia PVC rigid conduit with all fixing acessories laid in trenches not exc 30 cm in depth including necessary excavation and earth work in any type of soil or fixed to pole / wall and taking down old unserviceable cable and conduit complete all as specified and as directed. Note :- Two runs of two core 4 sqmm cable and one run of PVC conduit shall be measured as one unit length for the purpose of measurement.
Supply, laying, jointing and testing PVC insulated,unsheathed,multi-stranded, two core, aluminium conductor cable 6.00 sqmm in two runs through and including 25 mm dia PVC rigid conduit with all fixing acessories laid in trenches not exc 30 cm in depth including necessary excavation and earth work in any type of soil or fixed to pole / wall and taking down old unserviceable cable and conduit complete all as specified and as directed. Note :- Two runs of two core 6 sqmm cable and one run of PVC conduit shall be measured as one unit length for the purpose of measurement.
S&F in repair street light brackets made out of 25mm dia light grade GI tubing, bent to shape length not less than 1.20 metre fixed with suitable size of clamps, nuts, bolts etc all as required at site, complete all as specified and as directed. Note :- The cost of Clamps, nut bolts etc shall be included in the rate quoted.
S&F in repair street light brackets made out of 40mm dia light grade GI tubing, bent to shape length not less than 1.20 metre fixed with suitable size of clamps, nuts, bolts etc all as required at site, complete all as specified and as directed. Note :- The cost of Clamps, nut bolts etc shall be included in the rate quoted.
Taking out existing LT under ground cable 1100 volts grade PVC insulated PVC Sheathed armoured aluminium conductor of any size from trenches / ducts / pipe, on wall, poles and removing unserviceable cable from the site complete all as specified and directed .
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Taking down carefully from roof / wall of the building loose / hanging / de-shaped, aluminium / copper strips of any size and type including unserviceable insulators etc complete all as specified and as directed.
Refixing of serviceable aluminium strips of any size as obtained from taking down including supply and fix poecelin insulators of 15 BMD size 'T' type placed not more than 50 cm apart with screws/nut bolts etc complete all as specified and as directed.
S&F aluminium strip 25mm x 3.15 mm with saddles and fixing screws etc on roof and down conductor above ground level complete all as specified and as directed.
S&F in repair single pointed aluminium rod 12 mm dia and 300 mm long fixed with the roof in and including all fittings, fixtures and PCC 1:2:4 type B-1 block of size 100mmx100mm x100mm complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32mm x6mm thick by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. Note :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate, reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate no 3 of MES SSR Part-I. (ii) Item includes the cost of GI pipe up to 7.50m for protection of earth wire/strip. (iii) Item includes the cost of earth lead wire/strip up to7.50m (iv) PCC pit shall be provided at least 500 mm away from the existing pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Inspection and checking the defect of servo controlled voltage stabilizer 3 phase in put voltage 300-480 volts, output voltage 415+1% volt of capacity 75 KVA by visiting the installations at baytu,shiv,shayani,and chotain ascon Nodes complete all as specified and as directed Note: -(i) Parts replaced shall be measured and paid for as "Supply and fix in repairs" here-in-after. (ii)Normally visit at each Ascon unit for every 30 Days and in emergency breakdown with in 24 hours to be attended.
Inspection and checking the defect of servo controlled voltage stabilizer 3 phase in put voltage 300-480 volts, output voltage 415+1% volt of capacity 50 KVA by visiting the installations at DUND and KKB ascon Nodes complete all as specified and as directed Note: -(i) Parts replaced shall be measured and paid for as "Supply and fix in repairs" here-in-after. (ii) Normally visit at each Ascon unit for every 30 Days and in emergency breakdown with in 24 hours to be attended.
S & F in repairs controlled card for 75 KVA voltage stabilizer complete all as specified and as directed.
S & F in repairs controlled card for 50 KVA voltage stabilizer complete all as specified and as directed.
S & F in repairs Voltmeter 0-500 volts digital type square 96mm flush type complete all as specified and as directed.
S & F in repairs Ampremeter 0-50 Amps digital/Sqaure 96x 96mm flush type complete all as specified and as directed.
S & F in repairs switch for Auto/manual operation complete all as specified and as directed.
S & F in repairs CT's suitable for Ampere meter 150/10A ratio complete all as specified and as directed.
S & F in repairs CT's suitable for Ampere meter 100/5A ratio complete all as specified and as directed.
S & F in repairs LT Contactor ML-6 complete all as specified and as directed.
S & F in repairs LT Contactor ML-4 complete all as specified and as directed.
S & F in repairs servo motor complete all as specified and as directed.
S & F in repairs ON/OFF Load push button switch complete all as specified and as directed.
S & F in repairs Carbon bush suitable for 75/50 KVA complete all as specified and as directed.
Repair /Replacement of wiring of panel board of stabilizer with standard copper wire of suitable size including lugs/thimble and making connection and testing etc complete all as specified and as directed.
Repairs to High Mast light fittings of 60 to 100 watt,230/240 volts of any make, including taking down existing fittings from pole (15 Mtr height) and refixing the same in same position after replacement of unserviceable/defective parts of the fittings as required to make the fittings in smooth serviceable condition and testing complete all as specified and as directed.
Godara Construction and General Suppliers
M.D. CONSTRUCTION CO.
National Rewinding Works
Rasam Engg Co.
SOHANLAL MOHTTA
m/s jogaram sujaram
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .