Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹25.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.3 L+₹1.8 L (7.04%)Rejected-Finance | ₹27.3 L+₹1.8 L (7.04%) | L2 | Rejected-Finance Quoted amount is more than L1 |
| 3 | L3₹30.3 L+₹4.8 L (19.0%)Rejected-Finance | ₹30.3 L+₹4.8 L (19.0%) | L3 | Rejected-Finance Quoted amount is more than L1 |
| 4 | L4₹34.8 L+₹9.4 L (36.7%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹34.8 L+₹9.4 L (36.7%) | L4 | Rejected-Finance Quoted amount is more than L1 |
| 5 | L5₹41.0 L+₹15.5 L (60.8%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | ₹41.0 L+₹15.5 L (60.8%) | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Nov 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/REPLACEMENT OF ELECTRICAL FITTINGS AND FIXTURE INCLUDING REWIRING AND CONNECTED E/M WORK SERVICE FOR MH NAMKUM UNDER GE RANCHI
2022_MES_556495_1
8400/1158/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹60,000
Yes
1 Dec 2022
8 Oct 2022
5 Nov 2022
9 Oct 2022
3 Nov 2022
22 Oct 2022
Amount
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for re use to be measured separetly including making good the disturbed portion/surface. Complete all as specified and directed.
M&L point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with conceled Conduit with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick modular plate incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly all as specified and directed . (Note - Modular cover plate of any module with all fittings are included in point wiring.) Make- Havells/Anchor/Finolex
All as per item No 2 above but for one 3/5 pin socket 5 Amp on independent board.with 1.5 sqmm wire with 1.5 sqmm earth wire
All as per item No 2 above but for one 3/5 pin socket 5 Amp on same board, with 1.5 sqmm wire with 1.5 sqmm earth wire
All as per item No 2 above but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm complete all as specified and directed.
S&F switch piano flush type/Bell push, 5 Amps, single pole one way, complete all as specified and directed. (Make : Anchor/Havells/ABB ( ISI marked)
S&F socket 5 pins, 6 Amp, flush type piano (multi purpose) complete all as specified and directed. (Make : Anchor/Havells/ABB ( ISI marked)
S&F Socket 15 Amps flush type 230 Volts , AC complete all as specified and directed. (Make : Anchor/Havells/ABB ISI marked)
S&F switch 15 Amps flush type 230 Volts , AC complete all as specified and directed. (Make : Anchor/Havells/ABB ( ISI marked)
S&F switch socket combination 5 pins, 6 Amp, flush type piano (multi purpose) complete all as specified and directed, (Make : Anchor/Havells/ABB ( ISI marked)
S&F switch socket combination 5 pins, 6 Amp, flush type piano (multi purpose) alongwith top plug 5 Amps complete all as specified and directed, (Make : Anchor/Havells/ABB ( ISI marked)
S&F switch Socket 15 Amps flush type 230 Volts , AC complete all as specified and directed. (Make : Anchor/Havells/ABB ( ISI marked)
S&F switch Socket 15 Amps flush type 230 Volts along with top plug 15 Amps, AC complete all as specified and directed.(Make : Anchor/Havells/ABB ( ISI marked)
Supply & fixing switch modular type (ISI marked confirming to IS 3854:1997), single pole, one way 10 Amp , 240 Volts complete all as specified & directed.
Supply & fixing switch modular type (ISI marked confirming to IS 3854:1997)), single pole, one way 15/16 Amp 240 Volts complete all as specified & directed.
Supply & fixing socket modular type (ISI marked) confirming to IS 1293:2005, single pole, 6 Amps 2 pin/ 3 pin, 240 Volts complete all as specified & directed. .
Supply & fixing socket modular type (ISI marked) confirming to IS 1293:2005, single pole, 6/16 Amps twin 3 pin power socket ,240 Volts complete all as specified & directed.
Supply & fixing 5 step fan regulator modular type (ISI marked confirming to IS 3854:1997)), single pole, 240 Volts complete all as specified & directed
Supply & fixing Bell push modular type (ISI marked confirming to IS 3854:1997)), single pole, 5/6 Amp , 240 Volts complete all as specified & directed
Supply & fixing 5 step fan regulator single pole, 240 Volts complete all as specified & directed. Make- Anchor/Havells
M&L point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with PVC casing caping with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated modular plate incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly complete all as specified and directed Make- Havells/Anchor/Finolex
All as per item No 21 above but for one 3/5 pin socket 5 Amp on independent board.with 1.5sqmmwire with 1.5 sqmm earth wire complete all as specified and directed.
All as per item No 21 above but for one 3/5 pin socket 5 Amp on same board, with 1.5 sqmm earth wire complete all as specified and directed.
All as per item No 21 above but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm complete all as specified and directed.
S&F Ding Dong door bell complete .(Make : Anchor/Havells/ABB(marked)
S&F ceiling rose, surface backlite, 65x50mm, three terminals, Make : Anchor ISI marked.(Make : Anchor/Havells/ABB ( ISI marked) complete all as specified and directed
S&F LED bulkhead 10W with IP 65 protection 240V Make- Crompton Havells Phillips complete all as specified and directed
S&F LED Mirror Light 10 Watt with diffuser, Decorative type,complete all as specifed & directed. Make :-Crompton /Phillips/ Havells
S&F LED bulb 10 Watt suitable for angle lamp holder base B-22 230V ,complete all as specifed & directed. Make :-Crompton or equivalent in Phillips/ Havells
S&F 20W LED 6000K (4’) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, optics diffused, complete all as directed. CA Number, Two years Warranty End date and Phone number of Contractor to be endoresed in the item Make : Phillips Havells/Bajaj
S&F 36W LED 6000K (2X2) panel light mounted white powder coated luminaire screwless design , complete all as directed by Engineer-in-Charge.Make : Havells or equivalent in Crompton/ Phillips/Havells
S & F decorative wall mounting chrome finish 6W LED fitting along with wiring and electric connection including all necessary fixing arrangement on wall/ceiling complete all as specified and directed Make : Havells /Philips/Bajaj.
Dismantling and taking down existing unserviceable submain wiring from batten/conduit of any size and making good to disturbed surfaces to match the existing surfaces. Complete all as specified and directed
M&L submain wiring with 2X6.0 SQMM+1X6.0SQMM earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty in concealed conduit including taking down old wiring all accessories complete all as specified and directed. Make- Havells/Finolex/Polycab
Dismantling and taking down existing unserviceable cable of any size and making good to disturbed surfaces to match the existing surfaces. Complete all as specified and directed
S & Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed & directed. Make- Polycab/Havells/Finolex
S & Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed & directed.Make- Polycab/Havells/Finolex/CCI
S & Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed & directed.Make- Polycab/Havells/Finolex
Taking down unservicable main switches MCB's DB's etc any type and capacity including making good the disturbed surfaces to match the existing . Complete all as specified and directed
S & F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 10 ways.Make:-Havells / Legrand / L&T . Complete all as specified and directed.
All as per item No 40 above but 8 ways complete all as specified and directed
All as per item No 40 above but 4 ways complete all as specified and directed
S&F MCB SPN 32 to 63Amps 415V incl all termnials, fitting etc complete all as specified and directed. Make:-Havells / Legrand / L&T .
S&F MCB SP 06 to 40 Amps 415V incl all termnials, fitting etc complete all as specified and directed. Make:-Havells / Legrand / L&T .
S&F MCB TPN 40 to 63 Amps 415V incl all termnials, fitting etc complete all as specified and directed. Make:-Havells / Legrand / L&T .
S&F Distribution board 4 way TP&N double door are fitted with Bus Bars, Neutral Links, Blanking Plates, Suitable for FP MCCB. Complete all as specified and directed. Make:-Havells / Legrand / L&T
S&F CRCA sheet metal enclosure double door, outdoor type suitable size including single phase Energy meter Fixed with cable terminals incl 3 nos HDPE gland fixed on pole/wall/panel/where direction by Engr in charge with clamp nuts,bolts, PCC along with new waterproof wooden box etc complete all as directed. Make:-Indoasian/Havells / HPL / L&T
Taking down old burnt electric single phase meter of any type, submitting it to MES Store and S&F CRCA sheet metal enclosure double door, outdoor type suitable size including single phase Energy meter Fixed with cable terminals incl 3 nos HDPE gland fixed on pole/wall/panel/where direction by Engr in charge with clamp nuts,bolts, PCC along with new water proof wooden box etc complete all as directed. Make:-Indoasian/Havells / HPL / L&T .
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 15mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I. Note :(a)Three photos covering the steps involved in installation with the electrode plate be atttached witht the bills for payments. (b) The item should be connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
M/S Sahib N Sahiba Enterprises
Commercial Electric Co.
india trading company
BHARATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .