Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.5 L+₹84,350 (5.75%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.9 L+₹2.2 L (15.3%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹20.7 L+₹6.1 L (41.4%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SRINAGAR
GE AF SRINAGAR 190007
REPAIR / REPLACEMENT OF EXISTING DISTRIBUTION SYSTEM AND OTHER MISC WORKS AT DOMESTIC AREA UNDER AOR OF GE (AF) SRINAGAR.
2021_MES_461631_1
GE (AF) - 29/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF SRINAGAR
₹40,000
Yes
21 Sept 2021
20 Jul 2021
20 Aug 2021
20 Jul 2021
19 Aug 2021
6 Aug 2021
60 days
Amount
Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M depth and getting out for laying of underground cable etc in any type of soil complete all as specified and directed Engineer-in-Charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing of excavated soil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed Engineer-in-Charge.
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100 mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm complete all as specified and directed by Engineer- in-Charge. Note:- Only punned thickness shall be measured and paid.
S&F 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
S&F 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
Taking out carefully unserviceable LT under ground cable of sizes 16 Sqmm, 2 core from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
Taking out carefully unserviceable LT under ground cable of sizes 16 Sqmm, 4 core from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
Taking out carefully unserviceable LT under ground cable of sizes 25 Sqmm, 3.5 core from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
Taking out carefully unserviceable LT under ground cable of sizes 50 Sqmm, 3.5 core from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
Taking out carefully unserviceable LT under ground cable of sizes 70 Sqmm, 3.5 core from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade of following size laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
16 Sqmm, 2 core
16 Sqmm, 4 core
25 Sqmm, 3.5 core
50 Sqmm, 3.5 core
70 Sqmm, 3.5 core
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Laying Only of bricks retrieved from items no. 9.00 to 13.00 here-in-before laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Supply, installation testing & commissioning CPRI approved LT panel board cubical type of size 1.5 x 0.6 x 1.2 Metre suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork complete comprising of following including taking out the old unserviceable panel complete all as specified and as directed by Engineer-in-Charge.
Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Supply, installation testing & commissioning CPRI approved Feeder piller box of size 75 cm x 60cm x 45 cm, out door type ‘factory made’ CPRI Approved, made out from 3.15 mm CRCA Sheet supported with legs of 45 cm long made of iron angle 25 mm x 25 mm x 4mm thick, with 04 No's aluminium bus bar of 500 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement including MCCB 250 Amps 35 kA 415 Volts 50 Hz with adjustable thermal and magnetic setting and provn for incoming and outgoing cables with glands including spray painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, including dismantling of old panel complete all as specified and directed by Engineer-in-Charge.
Note: Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Taking down unserviceable light fitting any type from Pole / wall or any other location any capacity ,any height, any situation, repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts, replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing / re-hanging the same after repair in existing location or other location (as directed) and testing complete all as specified and directed by Engineer-in-Charge. Note:- (i) Spares required for repair will be measured and paid separately as supply only vide item No 20 to 23 here-in-after. (ii) Necessary T & P like ladder / Boom Vehicle, tools etc as required for taking down & fixing of Street light shall be provided by contractor without any extra cost of department.
Supply only LED driver of capacity 30 / 45 Watt as per sample for 240 volts complete all as specified and directed Engineer-in-Charge.
Supply only LED driver of capacity 50/60 Watt as per sample for 240 volts complete all as specified and directed Engineer-in-Charge.
Supply only LED driver of capacity 100 Watt as per sample for 240 volts complete all as specified and directed Engineer-in-Charge.
Supply only LED driver of capacity 150 Watt as per sample for 240 volts complete all as specified and directed Engineer-in-Charge.
S&F in repairs LED street Light fitting 45 Watt, system efficiency not less than 110 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
M&L for preparation of old painted steel surface of LT feeder pillar Box, 440 Volts, 3 phase of any size / location and applying two coats of synthetic enamel paint complete all as specified and directed Engineer-in-Charge.
M&L for Sub main wiring for connecting street light fitting from junction box with two single core, PVC insulated, (ISI marked) , unsheathed, 1100 volts grade, 2.5 sqmm multistranded copper conductor cable drawn into and including suitable size PVC conduit 20 mm dia ISI marked medium grade with all accessories and including one single core, 2.5 sqmm PVC insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire including taking down old pipe & cable complete all as directed & specified. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply, installation testing & commissioning bus bar chamber, factory made, weather and vermin proof having size 200 x 250 x 80 mm made out of 3.15 mm thick CRCA sheet, comprising of MCB SP 10A, C curve 10 KA breaking capacity 01 No's, 16 Amp 230 volt rated aluminium bus bar with mounting rail fixed on porcelein insulator, making holes on strips for connecting cables and fixing of bus bar chamber on street light pole with and including MS clamp of size 25 x 5mm including nut, bolts washers duly painted with 2 coats of enamel paint over a coat of red oxide primer including taking down old bus bar chamber, all as specified and directed.
Supply and fix in repair LED, post top lantern, 20 Watt, 230 volts AC, out door type, with decorative post 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp fixed over existing pole complete
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground, surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 150mm on all side, earth plate connected to galvanized steel strip of size 25 mm x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, light grade, and 32 mm bore galvanised iron light grade pipe for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), including funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Supply only LT insulation Tape of size 25 mm x 25 meter
Supply only insulation Tape of size 15 mm x 100 meter suitable for 11000V
Supply only aluminium thimble of size 10sqmm
Supply only aluminium thimble of size 16sqmm
Supply only aluminium thimble of size 25sqmm
Supply only aluminium thimble of size 35sqmm
Supply only aluminium thimble of size 50sqmm
Supply only aluminium thimble of size 70sqmm
Supply only aluminium thimble of size 95sqmm
Supply only aluminium thimble of size 120sqmm
Supply only aluminium thimble of size 150sqmm
Supply only aluminium thimble of size 185sqmm
Supply only aluminium thimble of size 240sqmm
Supply only aluminium thimble of size 300sqmm
S&F in repair timer distribution board with analog time switches complete of rating 65 Amps 3 pole 230 Volts 415 volt including taking down existing complete all as specified and directed by Engr in charge. Make :- Indoasian Cat part No. TL065ABO or equivalent cat No of Make C&S / HPL / Havells
M&L for painting of steel tubular poles of hight 7 to 7.50 meter above GL with cross arms and bracings with two coat of aluminium paint painting, including 30 cm wide black & white alternate strips up to 1.5 metre above from ground level with synthetic enamel paint incl numbering of the pole complete all as specified and directed.
Restretching / re fixing the existing LT OH / Lines ACSR conductor of any type and size including disconnecting binding wire on insulator, rebinding properly to avoid tension / fitting bending of poles, complete all as specified and directed by Engrr-in-Charge. Note:- Each line of conductor will be measured & paid separately.
Dismantling old u/s insulators of sizes, any type from pole.
Supply & fix pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers nand one galvanised nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix disc type, porcelain, vitreous white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 145 mm height, 255 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.
Supply & fix shakle type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 100 mm height, 115 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge.
Supply and fix in repair stay assembly for LT pole complete with accessories as shown in Electrical Plate No 1 (Dia of stay rod 16 mm) complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation footing / mass concrete etc.
S&F in repair MCCB 4 pole 415 volts microprocessor release type 400 amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 pole 415 volts microprocessor release type 630 amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 pole 415 volts microprocessor release type 250 amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 pole 415 volts microprocessor release type 160 amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair MCCB 4 pole 415 volts fixed type 100 amps with breaking capacity 16 KA, complete all as specified and directed.
S&F in repair MCCB 4 pole 415 volts fixed type 63 amps with breaking capacity 16 KA, complete all as specified and directed.
M/S LATIF AHMAD MIR
M/S TARIQ AHMAD SHEIKH
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .