Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹42.7 L+₹3.8 L (9.68%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹47.0 L+₹8.1 L (20.7%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹57.9 L+₹19.0 L (48.7%)Rejected-AOC | L4 | Rejected-AOC Not being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS/RECTIFICATION OF DAY TO DAY COMPLAINTS OF EXTERNAL WATER SUPPLY SYSTEM INCLUDING REPAIR/ REPLACEMENT OF CI/DI/GI/PPR PIPE LINE NETWORK, SLUICE VALVES, VALVE PIT CHAMBERS AND MISC REPAIRS IN E/M INSTALLATIONS INCLUDING CLEANING OF UG SUMPS,
2021_MES_445776_2
GE(U)/SEC/TOKEN/12 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹96,000
Yes
18 Sept 2021
3 Jul 2021
19 Jul 2021
5 Jul 2021
17 Jul 2021
5 Jul 2021
Amount
Repair/rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation,cutting of hard standing , returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 1 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 4 above but for GI tubing 40 mm bore to 50 mm bore.
Attending compaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION ( MARRIED / OTM/ single / multi story building ) , IDENTIFY THE FAULTS including rectification by taking down of existing GI/PPR tubing up to 80 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed.
Notes for Sl item No 1 to 6 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work above 1 CUM mesured and paid separately under relivent items . j) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. (k) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Rectification of lekages in pumping /delivery lines (GI/CI/DI/PPR/MS) of size 80 mm to 100 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and Lead joint , necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Rectification of lekages in pumping /delivery lines(MS/CI/DI/PPR) of size 150 mm to 400 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints,filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
M&L for attending break down of water supply pipe line at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads and repairs to GI/CI/DI/PPR/MS water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil, PCC, RCC, hard rock etc by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed including making good of disturbed surfaces. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, GI/DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up/down steel tubing laid in trenches, on wall/in floor/in plinth protection of bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Refixing of old steel tubing and connection in new or old position including cutting threads if required , fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia Notes for item No 14.01 to 14.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including , cutting threads if required , fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia Notes for item No 16.01 to 16.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
32 mm dia
63 mm dia
110 mm dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
110 mm dia Notes for item No 19.01 to 19.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings. Make : SFMC/WETFLOW/SAFE.
32 mm dia
63 mm dia
110 mm dia Notes for item No 21.01 to 21.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Make : SFMC/WETFLOW/SAFE.
32 mm dia
63 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position including segregation of serviceable pipes and keep in safe custody for reuse complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia Notes for item No 24.01 to 24.06 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm dia Notes for item No 25.01 to 25.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Hex Nipple
All as per item No 27 above but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per item No 27 above but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per item No 27 above but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40mm x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
Reducer Socket 40mm x 20 mm
Reducer elbow 40mm x 20mm
All as per item No 27 above but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Socket 50mm x 40mm.
Reducer Socket 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
Hex Nipple
All as per item No 27 above but for 80 mm bore.
Union
All equal Tee
Socket
Reducer Socket 80mm x 50mm.
Reducer Socket 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Hex Nipple
All as per item No 27 above but for 100 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Socket 100mm x 80mm.
Reducer Socket 100mm x 50mm.
Reducer Socket 100mm x 40mm.
Elbow
Reducer elbow 100mm x 80mm
Reducer elbow 100mm x 50mm
Reducer elbow 100mm x 40mm
Reducer tee 100mm x 100mm x 80mm
Reducer tee 100mm x 100mm x 50mm
Reducer tee 100mm x 100mm x 40mm
Hex Nipple
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
65mm dia bore. Note for Sl item No 34.01 to 34.06, Make : Zoloto /Kartar
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and flynut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for Arresting leakages of sluice valves by replacing Gland packing, gland bush, gland falange, nutbolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed for the following sizes:- Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland falange, nutbolts, gasket, packing materia etc as required to arrest the leakages.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm Dia
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 34 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm Dia
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
400 mm dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K506, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
150 mm Dia
200 mm Dia
300 mm Dia
S&F, connecting and testing in repair of Cast Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, K517, PN-1.6 both ends flanged etc including jointing materials of following sizes complete all as specified and directed.
65 mm Dia
150 mm Dia
S&F, connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
50 mm Dia
65 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F, connecting and testing in repair of Cast Iron double orifice kinetic Air Valve ISI Marked IS : 14845 type DK in PN 1.0 flanged end K541 with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as per specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
M&L for Construction of new PCC solid Masonry valve chamber of size 1500 X 1500 X 1500 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for cleaning of under mentioned RCC over head reservoir, under ground sump/semi under ground sump of any size and any height of staging by using mechanical means and scientific cleaning by carrying out the following stages of cleaning process for disinfection of surfaces:- (i) Cleaning of all external surfaces with hot water and Odor removal. (ii) The inner surface of the walls and ceilings of the tank shall be cleaned with high pressure jet pump after dewatering in the tank. (iii) After thorough cleaning of the tank, removal of algae calcination and other dust particles with high pressure including hot water treatement @ 50 degree centigrade. (iv) Vacum cleaning and sludge shall be removed by using pump and the sludge has to be disposed off at a places as directed. (v) After removing the sludge from tank, the floor and inner surfaces of the tank shall be cleaned by using an industrial vaccum cleaner and the tank shall be made fully dust free and disinfection with bio-degradable chemical/anti bacterial spray and surfaces to be proven non toxic. (vi) After complete treatment is carried out, writing "capacity of tank, date of cleaning and due date of cleaning" AND NAME OF OFFICE on walls as specified and as directed.
Over Head Reservoir capacity 50000 Gallon at MAP JCOs, ORs Md Accn, ABC Line Md Accn, 54 DOU, Safilguda Pump House I & II, RAMC Pump house.
Over Head Reservoir capacity 250000 Gallon at BMH Line.
Under Ground Sump capacity 35000 to 50000 Gallon at 36 JCO Md Accn.
Under Ground Sump capacity BETWEEN 2500 TO 35000 Gallon at 54 DOU, Thapper Stadium, Safilguda Pump House No-I & II, GLPH & AOC Record.
Under Ground Sump capacity 150000 Gallon at RAMC Pump House.
Under Ground Sump capacity 500000 Gallon at GLPH.
Notes for item Nos 49.01 to 49.06 :- (i) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted deemed to be include all safety precautions which shall be taken while working on RCC over head tank /underground sump and contractor or his authorised Engineer shall be available during execution of the job. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/diesel shall not be provided by the MES. (iv) Contractor will not be allowed more than one day to do the work inside of the each OH Tank / UG Sump to prevent interruption of water supply to the users.
Supply only for Bleaching powder grade-I, ISI marked (each bag of 25 Kgs) for using in UG sump & over head tanks at the locations of RAMC Pump House, GLPH, for purifying drinking water complete all as specified and deoposited in store yard of AGE E/M II as directed. Make :- Grasim/Lion/Shaktiman Notes :- (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed at various installation of AGE E/M No II. (ii) The quoted rate is deemed to be included complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost. (iii) Supplier must provide alongwith materials, "Certificate of compliance/Test certificate" in original indicating batch No, date of manufacturing and quantity supplied.
S&F, connecting and testing in repair of Gun Metal (Bronze)/brass non return (Reflux) valves etc including jointing materials of sizes 50 mm complete all as specified and directed.
Supply and fixing of DOL Starter suitable for upto 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp. Make : L&T cat part No CS90947 or equivalent of Havells/CG complete all as specified and as directed.
Supply and fixing of single phase preventer suitable for upto 7.5 HP motor. Make : L&T cat part No CS94824DOOO or equivalent of Havell/CG complete all as specified and as directed.
M&L for replacement of PVC insulated, submersible electric cables of 2.5 Sqmm 3 core with stranded copper conductor, 1100 volts laid in bore well including jointing and testing complete all as specified and directed.
Supply and fixing SFMC PP-R Pipe fittings and accessories 32 mm bore, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Reducer Socket 32 x 25 mm
Socket
All equal Tee
Union
Gate Valve
All as item No 55 above but 63 mm bore :-
Reducer Socket 63 x 32 mm
Socket
All equal Tee
Reducer Tee 63 x 63 x 32 mm
Union
Gate Valve
All as item No 55 above but 110 mm bore :-
Reducer Socket 110 x 63 mm
Socket
All equal Tee
Reducer Tee 110 x 110 x 63 mm
Supply and installation CPRI approved pump starter electric control panel board, for out door use, single door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size 50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 32 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCB 3 pole, 10 KA c curve 415 Volts, 32Amps - 01 No (b) DOL starter in sheet enclosure type MK-1, Motor rating AC-3 duty, 415 Volt, 50 Hz sutable of 7.5 HP, relay max rang 15-25 Amps - 01 No (c) Single Phase Preventor Relay type Sz5 (6wire), 415 Volts - 01 No
Supply, fabrication, installation connection and testing of Feeder Pillar box outdoor type of size 1.2 m (L) x 0.6 m (W) x 1.5 m (H) (totally enclosed type) with canopy made out of 3.15 mm thick CRCA sheet with copper busbar of capacity 300 Amps with colour sleeve (RYB & N) = 04 No's with suitable size of PVC copper conductor thimbles glands for connections with angle iron 40 x 40 x 6 mm frame work allround having double hinged double door shutters on front and back with MS sliding bolts - 250 mm long for locking arrangement. The base of the feeder box shall be provided at 0.60 m above the ground level 4 Nos angle iron legs made from angle iron 50 x 50 x 6 mm shall be embedded on PCC 1:2:4 type B1 300 x 300 x 300 mm with depth below the ground level. The feeder pillar box shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete internally & externally including disconnecting/taking out old existing unsv FP box complete all as specified and directed.
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, TO CROSS WATER PIPE LINE UP TO 200 mm dia in any length including jointing materials and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed INCLUDING MAKING GOOD OF DISTURBED SURFACES. NOTE: PIPE WILL BE MEASURED AND PAID SEPARATELY UNDER RELIVENT ITEMS
M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping & platering of valve chamber complete all as directed
Supply, fixing, testing the digital water level indicator of 19mm size digital display including 4 core 0.5 Sqmm size cable of required length. The device circuit housed in high impact polysterene moulded box with nylon moulded connection strips. The level system is a resistance transducer which is unaffected by corrosion and other contents available in water. The whole unit is electronically controlled and the upper level & lower level alarm indications made by highly sensitive micro switches. The upper & lower level is pre adjusted as per required & alarm is activated at these level one minute auto off alarm. The complete units will be in two parts, each parts will be housed in MS CRCA sheet box separately (one at tank and second at pump house) and proper powder coating paint with locking arrangements as in repairs complete all as specified and directed.
Supply and replace MCB SPN 20 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TPN 32 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TP 32 Amps in starter panel board c Curve 10 KA complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for FILLING / FOOTHPATH/ ROAD complete all as directed
M&L for replacement of existing water level indicator in OHT of any size , capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support , PCC ,display board ,indicator/pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed. (All area undeb AGE E/m -II) Note : Quoted rates are inclusive of all arrangement required for the above.
M&L for replacement of existing water level indicator in UG Sump of any size , capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support , PCC ,display board ,indicator/pointer , necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping /cleaning complete all as directed .
Supply and fixing of anodised aluminium frame and aluminium grill for ventilators / Vent Cowl of RCC OHT ( Average height 30 m ) , partitions etc with one or more rebates including joining cleat for fixing etc including cleats and rubber gaskets complete all as required for fixing as specified and directed in cluding dismentling old one. Note: Quoted rated inclusive of all arrangements required for fixing of Aluminium frame incliding necessary gusket , necessary scaffolding as required for fixing of the frame
M&L for Wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of staples size of the mesh 20 mm complete al as required for fixing at Aliminium frame complete all as specified and directed including dismantling old one.
M&L for painting of raising main, distribution, wash out and overflow pipes on over head tank with suitable colour coding of pipe dia 100 to 200 mm by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of raising main, distribution, wash out, pumping /delivery and overflow pipes on underground sump with suitable colour coding of pipe dia 100 to 300 mm by using synthetic enamelled paint first grade after scrapping /cleaning
Repairing of Sluice valves raising / non raising types after dismentling the same by replacing stem , gate/ disc , stuffing box,Seat, Gland packing, gland bush, gland falange, nutbolts, gasket, packing material, threading , welding as required for proper functioning of Sluice valves complete all as directed. Note: Quoted rates inclusive of all the materials mentioned above like stem , gate/ disc , Seat stuffing box Gland packing, gland bush, gland falange, nutbolts, gasket, packing materia etc as required for proper functioning of the valves
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
Supply only sodium Hypochlorite having 12%-15% available chlorine content in liquid from for water treatment (Drinking water and swimming pool) packed in 50 kgs drum complete all as specified and as directed. Make : M/S SHREE RAYALASEEMA Hi STRENGTH HIYPO LTD (PURI CHLOR), ALTOC-GP of M/s DECLIBAC TECH PVT LTD, POTTER AND WATTS, BRIOZINGngements as in repairs complete all as specified and directed.
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 100 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required , bends welding and cutting etc as required for fixing of pipe .
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 150 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts complete all as specified and directed. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size as required , bends,welding and cutting etc as required for fixing of pipe .
Supply and lay MS black tubing ERW welded including specials , having outside dia of 212 mm and 6 mm thick ISI marked conforming to IS 3589 - 2001 with plain ends complete including connecting of MS pipes and specials by welding, leak testing of pipe line laid in trenches / floors / walls / ducts complete all as specified and as directed by the Engineer-in-charge. Note: Quoted rate is inclusive of supply and fixing of flange of suitable size, bends as required , welding and cutting etc as required for fixing of pipe .
Supply and lay MS black tubing ERW welded , having outside dia of 314 mm and 7 mm thick ISI marked conforming to IS 3589 - 2001 with plain ends complete including connecting of MS pipes and specials by welding, leak testing of pipe line laid in trenches / floors / walls / ducts complete all as specified and as directed by the Engineer-in-charge. Note: Quoted rate is inclusive of supply and fixing of flange and bends of suitable size as required , welding and cutting etc as required for fixing of pipe .
Supply only calcium Hypochlorite having 60%-70% available chlorine content in granular from (calcium based granular disinfectant) for water treatment (Drinking water and swimming pool) packed in 45 Kgs/50 kgs each drum complete all as specified and as directed. Make : M/S SHREE RAYALASEEMA Hi STRENGTH HIYPO LTD (PURI CHLOR), ALTOC-GP of M/s DECLIBAC TECH PVT LTD, POTTER AND WATTS,
Core cutting / drilling of Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia incuding necessary mechinaries complete all as specified and directed
Supply and replace 90 degree long threaded bend suitable for 20 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for 25 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for 40 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for50 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for 65 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for 80 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree long threaded bend suitable for 100 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree Double flanged bend suitable for 100 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree Double flanged bend suitable for 80 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree Double flanged bend suitable for 65 mm dia medium grade Gi pipe complete all as specifed and directred
Supply and replace 90 degree Double flanged bend suitable for 50 mm dia medium grade Gi pipe complete all as specifed and directred
M/S AKSHATHA ENTERPRISES
Srinivash Engineers
Haasith constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .