Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC VILL NUTAN PALLY AMMUNITION ROAD PO PS BUD BUD DIST BURDWAN PIN 713403 WB | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L1 | Accepted-AOC ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹27.0 L+₹57,095 (2.16%)Rejected-AOC ANURAGPUR PO PANAGARH BAZAR DIST BURDWAN WEST BENGAL 713 148 | PANAGARH BAZAR | BURDWAN | WEST BENGAL | 713148 | L2 | Rejected-AOC HIGHER BID VALUE | |
| 3 | L3₹27.2 L+₹81,645 (3.09%)Rejected-AOC | L3 | Rejected-AOC HIGHER BID VALUE | |
| 4 | L4₹28.8 L+₹2.4 L (9.06%)Rejected-AOC | L4 | Rejected-AOC HIGHER BID VALUE | |
| 5 | L5₹29.5 L+₹3.1 L (11.9%)Rejected-AOC MONIRAMPUR DASPARA P O BARRACKPORE | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 743101 | L5 | Rejected-AOC HIGHER BID VALUE |
Tender Value
₹44.7 L
EMD Value
₹89,420
Closing Date
19 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
REPAIR / CLEANING OF SEWAGE LINES, DRAINS, CLEANING OF SEPTIC TANKS SOAKAGE WELLS AND OTHER MISC B/R WORKS OF ALL UNITS IN RESTRICTED AND UNRESTRICTED AREA OF AGE B/R-II UNDER GE PANAGARH
2022_MES_564103_1
8826/E8
Open Tender
Civil Works
Item Rate
270 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹89,420
Yes
18 Jan 2023
19 Nov 2022
21 Dec 2022
19 Nov 2022
19 Dec 2022
5 Dec 2022
Amount
Cleaning and desilting of sewge lines upto 150mm dia and depth up to 1.50m, cleaning the lines by manual roding/mechanically jet pumps/sewage cleaning mechenie and flushing out by means of pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary, removing silt sludge etc, sprilinkling bleaching powder on the silt to avoid smell including all precautionery and saftey measures, such as saftey belts, ligthing arrangement face mask glouse etc and removing the same ( silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulation of civil authorities and flushing the sewerage lines with fresh water etc., complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 1.00 here-in-before but dia 150mm to 300mm, complete all as specified and as directed.
All as per Item No. 1.00 here-in-before but dia 300mm to 600mm, complete all as specified and as directed.
Attending day to day complaints for cleaning of localaised blokage from floor/nahni trap, soil, waste pipe, WC etc. up to including 1st man hole and removing sludge/waste up to 50m distance and burning the same in pit, complete all as specified and as directed.
Cleaning and desilting of manholes by means of manual/mechanical jet pumps/sewer cleaning machine, depth not exceeding 1.50m and pumping out/removing liquid wasteage and plugging the end sewer pipes or diverting the flow in to drains if necessary removing silt, sludge etc, sprinkiling bleaching powder on the silt to avoid bad smell including all precautionery and saftey arrangement such as face mask gloves etc. and removing the same ( silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MD land all as per existing rules and regulation of civil authorities and flushing the sewage lines with fresh water etc., complete all as specified and as directed by Engineer-in-Charge measures, such as saftey belts.
All as per Item No. 5.00 here-in-before but depth of man hole exc 1.5m and n.exc 3.0m, complete all as specified and as directed.
M&L for cleaning of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content fom the septic tank/soakage pit by using honeysucker mechnical method including flushing with fresh water and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab, complete all as specified and as directed.
For Sl Item No. 1.00 to 7.00 above contractor shall adhere : Note : The Contractor shall estimate the no of manpower as per requirement of blockage clearance with consultation of GE/AGE. The contractor should provide manpower accordingly.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for cesspits, manholes etc, and getting out in soft/loose soil even in foul position complete all as specified and directed.
All as per Item No. 8.00 here-in-before but in any type of soil mentioned here-in-above but depth 1.5m but not exceeding 3.00m, complete all as specified and as directed.
All as per Item No. 8.00 here-in-before but in hard/dense soil mentioned here-in-above but depth exc 3.0m but not exceeding 4.50m, complete all as specified and as directed.
Returning, filling in and including spreading, leveling, watering & well ramming in layers n.exceeding 25 cm in soft/loose soil, complete all as specified and as directed.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in soft/loose soil, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness (above or below ground level), complete all as specified and as directed.
Demolition of reinforced cement concrete as in cover slabs of manhole or septic tank, soak pit and walls, basement walls and in foundation, complete all as specified and as directed.
Demolition and breaking up drain pipes of internal dia 150mm (SGSW/PVC/RCC etc.) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 150m, complete all as directed by Engr-inCharge.
All as per Item No. 15.00 here-in-before but internal dia of pipe 300mm, complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 15.00 here-in-before but internal dia of pipe 450mm, complete all as directed by Engineer-in-Charge.
Supply and laying UPVC Eco drain Hi-tech pipe drainage sewer system pipe bearing 160 mm dia minimum 4mm thick incluing jointing with coupler, bend tee as per site requirement complete laid in trenches or floors, complete all as specified and as directed. Note : Necessary PCC haunching/benching/packing shall be measured and paid separately.
M&L for Reinforced concrete pipes, class NP2, dia 300mm laid and jointed complete with collars, complete all as specified and as directed.
M&L for Reinforced concrete pipes, class NP2, dia 450mm laid and jointed complete with collars, complete all as specified and as directed.
M&L for Concrete bed to 150 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 using 40mm graded stone aggregate, complete all as specified and as directed.
All as per Item No. 21.00 here-in-before but internal dia of pipe 300 mm, complete all as specified and as directed.
All as per Item No. 21.00 here-in-before but internal dia of pipe 450 mm, complete all as specified and as directed.
Demolition of brick work built in cement mortar for cracked wall of manholes, septic tank, soak pit etc. in foul position, complete all as specified and as directed.
M&L for brick work with fly ash bricks straight curved on plan exceeding 6m mean radius for manholes/septic tank/soak well etc./ in sewer works with old size bricks in Cement Mortar (1:4), complete all as specified and as directed.
All as per Item No. 25.00 here-in-before but except Fly ash bricks, complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete for bottom of manhole, complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel and drain, complete all as specified and as directed.
Taking down cement plaster from inside/outside of existing septic tank/manholes etc. incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises, complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) inside and outside brick wall of manhole /septic tank /concrete surfaces even and smooth with out using extra cement, complete all as specified and as directed.
M&L for Setting coat of 3mm thick of CM (1:2), trowelled to even and smooth finish over rendering 15mm thick in CM 1:4 on fair faces of brick work finished surface even & smooth with using water proofing compound @ 2%, complete all as specified and as directed.
Supply only integral waterproofing compound.
M&L for providing RCC precast cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) as in cover slab for manhole and similar article with plain face set in cement mortar (1:4), complete all as specified and as directed.
S&F SFRC (Steel Fibre Reinforced Concrete) Manhole Cover with Frame, Shape round/square, (40 to 50 Kg approx ) set at the top of the manhole at site complete as per manufacturer instruction and as directed by Engineer-in-Charge.
M&L for mild steel TMT bar 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia, complete all as specified & as directed by Engineer-in-Charge.
M&L for mild steel TMT bar 6mm to 8 mm dia, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia, complete all as specified & as directed by Engineer-in-Charge.
M&L for RCC type B-1 (1:2:4) (using 20 mm graded aggregate) providing RCC slab supported in wall beams and column and simillar works, complete all as specified and as directed.
Taking down soil/waste/ rain water pipes (any size or pattern), including all fittings and removal off the site, complete all as specified and as directed.
S&F in repair's 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with clamps and jointed, complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 39.00 here-in-before but 75 mm bore, complete all as speified and as directed.
S&F in repair's 110mm bore PVC (SWR) bends any radius, complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 41.00 here-in-before but with access door.
S&F in repair's 110 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door, complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door, complete all as specified and as directed.
S&F PVC (SWR) reducers of 110 mm bore, complete all as specified and as directed.
All as per Item No. 45.00 here-in-before but 75 mm bore.
S&F 110 mm PVC (SWR) branch piece, single Y equal or unequal, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) bends with rubber ring joints fixed to wall and jointed complete, all as specified and as directed by Engineer-in-Charge.
All as per Item No. 48.00 here-in-before but with acees door.
S&F in repair's 75 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door, complete all as specified and as directed.
S&F in repair's 75 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch pipe Y junction single equal or unequal with access door, complete all as specified and as directed.
S&F 110mm bore PVC(SWR) vent Cowl, complete all as specified and as directed.
S&F 75mm bore PVC(SWR) vent Cowl, complete all as specified and as directed.
M&L for 1st quality joints free non skid ceramic colour tiles 7 to 8mm thick (square/rectangular) area of each tiles exc. 0.11 sqm but n. exc 0.18 sqm of approved colour as in floors etc set and joined in neat cement slurry over 15mm thick sreed bed of cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Material and labour for glazed ceramic colour tiles 350X250x 7mm thick as in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 10mm thick rendering in cement mortar 1:3 all as specified and directed by Engineer-in-Charge incl Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor for levelling course, complete all as specified and directed by Engineer-in-Charge.
S&F in repair's Water Closet Vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and to flushing pipe, antisyphonage connection pipe etc complete making good disturb surface with existing finish of floor all as specified & as directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan, pedestal pattern Pedestal pan and trap(excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc and including seat and cover for pedestal pan, complete all as specified and as directed.
S&F in repair's 10 litres capacity PVC low level flushing cistern complete with all fittings, complete all as specified and directed by Engineer-in-Charge.
S&F in repair's flush pipe of 32 mm dia polyethylene of low or high density of PVC for low level cistern, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete type B0(1:2:4) using 12.5mm graded stone aggregate as in benching, bed block, coping of manhole, complete all as specified and directed by Engineer-in-Charge.
Extra for fair finish drain or channel to any girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc., complete all as specified and as directed by Engineer-in-Charge.
Demolition of PCC in any description and in any position or otherwise specified, complete all as specified and as directed.
M&L for PCC type E-2 1:5:10 (using 40mm graded aggregate) as in filling of sunken floor, complete all as specified and as directed.
M&L for 10 mm thick cement plastering in cement mortar (1:3) finishing even and smooth without using extra cement mixed with WPC, complete all as specified and as directed.
M&L for (a) providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementious composite compound coating of make as pproved in technical instruction 5/2003 (b) First layer of slurry of cement @ 0.500 Kg/Sqm mixed with acrylc based polymer modified cemmentious compounds @ 0.250 Kg/Sqm. This layer will be allowed to cure for 4 hours. (c) Second slurry of cement @ 0.500 kg/Sqm mixed with acrylic based polymer modified cementious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cur for 4 hours followed with water curing for 48 hours.
S&F 32 mm dia GI spout light grade for sunken portion, complete all as directed at site.
S&F in repair's grating square or round 150mm size of PTMT (minimum 100 gms), complete all as specified and as directed.
Supply & Fix in repair's CP health faucet with 1.50m long tube & hook, complete all as specified and as directed.
Cutting all plant/trees growth at top of roof and outer surface of walls/sanitary/water supply pipe lines pouring of acid on the root removed area and cleaning of surfaces and making good in CM 1:4 or PCC 1:2:4 type B0 using 12,5 graded stone aggregate and finishing the surface smooth including removing all algae and waste materials (the raye is inclusive of formwork/scaffolding required too reach the area of vegitation growth and removing debries to distance n. exc 50m, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 15mm dia bore steel tubing and connection including cleaning for refixing or remove to store, complete all as specified and as directed.
S&F 15 mm dia bore steel tubing medium grade and connection, complete all as specified and as directed.
All as per Item No. 73.00 here-in-before but fixing only.
M&L for joining / sealing the joints of PVC pipe collar, band, tee eyc with PVC solvent cement or equivalent to prevent the leakage through the respective joints, complete all as specified & as directed by Engineer in Charge for 110mm bore pipe.
M&L for cement concrete Type B0 (1:2:4 ) using 12.5mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge, complete all as specified and as directed by Engineer-in-Charge.
M&L for Mild steel work such as Bands, straps, supports or stays for rainwater, ventilating pipes, handmade clamps, hold fasts and similar small articles conforming to Fe-410-0 or Fe-310-0, complete all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in plith protection, complete all as specified and as directed by Engineer-in-Charge.
Schedule of Credit
UNIQUE ENTERPRISE
M/S MADAN MOHAN KAKAR
Jaibalaji Enterprise
M/S MODERN CONSTRUCTION
M/S JK TRADING
ROY ENTERPRISE
Hooghly Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .