Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹20.4 L+₹89,604.97 (4.59%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹20.7 L+₹1.2 L (6.13%)Rejected-Finance 00 VPO SALWAN 132046 | KARNAL | HARYANA | 132046 | L3 | Rejected-Finance Rejected |
Tender Value
₹21.2 L
EMD Value
₹42,366
Closing Date
30 Apr 2026, 5:00 pmClosed
Sh Jai Dev Sharma
Municipal Committee Assandh
Repair of harijan community centre in ward no 1 Assandh (Only for L and C Society Ltd)
2026_HRY_517398_1
2026531BD157 9B24 42EC 9899 9A95C80AF70C313ULB
Open Tender
Civil Works
Works
140 days
Assandh
2 documents required · 2 mandatory
₹1,000
Yes
₹42,366
Yes
13 May 2026
24 Apr 2026
1 May 2026
24 Apr 2026
30 Apr 2026
24 Apr 2026
24 Apr 2026 - 26 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate] | - | cum | 1,863 | - |
| 2 | [10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate] | - | Sqm | 987 | - |
| 3 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] | - | Sqm | 113 | - |
| 4 | [11.57]Providing and laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. [Through Rate] | - | Sqm | 68 | - |
| 5 | [11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] | - | Sqm | 138 | - |
| 6 | [13.3.2.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb [Through Rate] | - | Metre | 364 | - |
| 7 | [23.1.2.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate] | - | Each | 876 | - |
| 8 | [23.1.3.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe, without separate control switch Group B [Through Rate] | - | Each | 405 | - |
| 9 | [23.1.4.3]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 4.3. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group C [Through Rate] | - | Each | 1,277 | - |
| 10 | [23.22.1.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.2. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 100 to 125 Amp, 25 Ka [Through Rate] | - | Each | 2,195 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_596270.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .