Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹46.6 L+₹2.7 L (6.16%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SRIRAM ELECTRICALS L1 | GPK ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00Assembling, installation, testing and commissioning of MCB DB enclosure already embedded in the wall including supply of Engraved Circuit Identification Plate and Danger Board as per the detailed specification for the following size of MCB DBs. (Refer Sec VI, Clause No.15.3). | |||||
| 1.10 | SPN, 12 Way Distribution Board | 75 | Nos. | 600 ₹45,000 Lowest | 850 ₹63,750 |
| 2.00Supply fixing testing and commissioning of the following RCCBs & MCBs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). | |||||
| 2.10 | RCCB DP 63A sensitivity 30mA, TYPE Hpi | 75 | Nos. | 5,200 ₹3,90,000 Lowest | 5,800 ₹4,35,000 |
| 2.20 | 6-32 Amps SP MCB (Type-C) | 670 | Nos. | 280 ₹1,87,600 | 275 ₹1,84,250 Lowest |
| 3.00Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7). | |||||
| 3.01 | One / Two Module (Suitable for 1 / 2 Module Box ) | 190 | Nos. | 95 ₹18,050 | 75 ₹14,250 Lowest |
| 3.02 | 3 Module. (Suitable for 3 Module Box) | 70 | Nos. | 110 ₹7,700 | 90 ₹6,300 Lowest |
| 3.03 | 4 Module. (Suitable for 4 Module Box) | 100 | Nos. | 125 ₹12,500 | 105 ₹10,500 Lowest |
| 3.04 | 6 Module.(Suitable for 6 Module Box) | 210 | Nos. | 170 ₹35,700 | 145 ₹30,450 Lowest |
Tender Value
₹42.4 L
EMD Value
₹84,800
Closing Date
26 Jan 2026, 3:00 pmClosed
Chief Engineer, CEG,GSO
Room No. 306, GSO Annex building, Kalpakkam - 603102
Electrical refurbishment of residential quarters for South PDPM Houses (Phase-2) in Kalpakkam Township
2025_GSO_891672_1
GSO/CTC/ESD/288/2025
Open Tender
Electrical Works
Item Rate
365 days
DAE Township, Kalpakkam
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹84,800
10 Feb 2026
30 Dec 2025
27 Jan 2026
30 Dec 2025
26 Jan 2026
16 Jan 2026
31 Dec 2025 - 13 Jan 2026
Assembling, installation, testing and commissioning of MCB DB enclosure already embedded in the wall including supply of Engraved Circuit Identification Plate and Danger Board as per the detailed specification for the following size of MCB DBs. (Refer Sec VI, Clause No.15.3).
SPN, 12 Way Distribution Board
Supply fixing testing and commissioning of the following RCCBs & MCBs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
RCCB DP 63A sensitivity 30mA, TYPE Hpi
6-32 Amps SP MCB (Type-C)
Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7).
Supply, installation, testing and commissioning of LED Lamps/ as per detailed specification and as directed by Engineer in Charge.
Supply, installation, testing and commissioning of 1 x 25 W, 4 feet LED Patten along with supply of necessary fabricated brackets to mount the light fitting and supply and fixing of 6 A, 240 V, 3 Plate, Ceiling rose as per detailed specification and as directed by Engineer in Charge.
Supply, transportation, installation, testing and Commissioning of Wall (surface) mounted 6 W Bulk Head luminaires. - Catalogue No : WT202W LED6S CW PSU S2 PC or equivalent and Lamp Type LED. (Refer Sec VI, Clause No.16.1).
Supply, installation, testing and commissioning of 6 A, 240 V, 3 Plate, Ceiling rose with PVC Junction Linker as per detailed Specification and as directed by Engineer-in-charge.
Supply and installation of 6 A, 230 V, Angle Lamp Holder along with PVC Junction Linker as per detailed Specification and as directed by Engineer in Charge.
Supply and installation of Electronic Calling Bell as per the detailed specification and as directed by Engineer in Charge.
Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of 3 Core, 1.0 Sq.mm PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2).
230 mm dia Medium duty, Double ball bearing exhaust fan
Supply, Installation, testing and commissioning of following sizes of ceiling Fans and safety steel rope with 3 Core, 1.5 Sq.mm flexible copper cable including earth connection. Supply and fixing of regulator is not included in the scope of this item. (Refer Sec VI, Clause No.17.1).
1200mm Sweep AC ceiling fan.
1400mm Sweep AC ceiling fan.
Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29)
32 x 12mm size of PVC Mini trunking
25 x 12 mm size of PVC Mini trunking
20 x 12 mm size of PVC Mini trunking
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
Wiring with 2 Runs of 6.0 Sq.mm Copper wires for Phase, Neutral and 2 Runs of 2.5 Sq.mm Copper wires for Earth from Energy Meter Distribution Boards to SPN Distribution Boards.
Wiring for Power Points with 2 Run of 4.0 Sq. mm Copper Wire for Phase, Neutral and 1 Run of 2.5 Sq.mm Copper Wire for Earth.
3 Runs of 2.5 Sq.mm Copper Wire for Phase, Neutral and Earth.
Wiring with 2 Runs of 1.5 Sq.mm for Phase, Neutral and 1 Run of 2.5 Sq.mm copper wires for Earth.
Wiring for Power Points with 1 Run of 4.0 Sq.mm Copper Wire.
Wiring for Light/Power Points with 1 Run of 2.5 Sq.mm Copper Wire.
Wiring for Light/Power Points with 1 Run of 1.5 Sq.mm Copper Wire.
Wiring and termination for Telephone point with 1 Run of 0.61 mm dia, 250 V grade PVC insulated, twin twisted, single pair, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking including of supply of Telephone wire. (Refer Sec VI, Clause No.18)
Wiring for Television point including supply of RG-6 Co-axial cable from terminal junction box to the TV point provided in the living hall in each Quarter in existing concealed PVC Rigid conduits/Casing & Capping including connecting the same to the socket. as per the detailed Specification. (Quantity indicated is running length of 1 Run of Wire), (Refer Sec VI, Clause No.18)
Supply and Installation of P3 grade laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification.
Supply and installation of 63 Amps, 500 Volts 4 way SS stud type Terminal block with DIN rail for mounting and as directed by the Engineer-in-Charge.
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)
3/3.5/4 Core upto 25 Sqmm
Relaying of one number 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches on walls, poles and through embedded pipes using the retrieved spacer & clamps as per the detailed specification. (Note: Cable will be supplied by department as free issue item) (Refer Sec VI, Clause No.6)
3/3.5/4C X Upto 25 Sqmm
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
4 Core x 10 Sqmm
Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately (Refer Sec VI, Clause No.10.6).
4C x 10/16 Sqmm Aluminium Cable
Assembling, testing and commissioning of flush mounting 20 Amps, 230 Volts, 2 Pin + Earth, 1 Phase Metal Clad Socket (AC Point) including supply of 1 No 20 Amps Single Pole MCB C Seires as per the detailed specification.
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
Title
General Information for guidance of tenderers
Schedule of Quantities
The schedule of quantities is to be read for the purpose of pricing in conjunction with the special conditions, general rules for the guidance of contractors, conditions of contract, specifications, scope of work (Section V), and General Specification (Section VI, VI MNC), drawings, schedule of supply of materials and the appendices for complete interpretation of this scope of work quantity wise.
The prices inserted in the schedule of quantities shall be inclusive of value of the work described including all cost and expenses, which may be required in and for the construction of the work described together with the general risks, liabilities and obligations not forth or implied in the documents on which the tender is to be based.
The quantities stated are to be considered approximate only and the unit prices entered in the schedule of quantities and prices shall apply only to the actual quantities measured in the completed work in accordance with the specifications.
Items of work described in brief are detailed under specification of Work.The scope of work will not be estimated from the brief description of this schedule.
Rate quoted must include all components required for meeting the specification and performance requirements of the item irrespective of whether they are specifically brought out in this schedule or not.
All the materials other than those shown in schedule of supply of materials in section VII are to be arranged by the contractor and his rates should account for the same.
Rates quoted for all items in this tender shall include cost of all materials. Department will not supply any materials other than materials stipulated in Section - VII of the tender and as such the rates quoted must be all inclusive.
If contractors need any clarification they are required to contact the ‘Head, CTC, GSO, Kalpakkam – 603 102, Chengalpattu district, Tamilnadu (Ph – 044 - 27481238 and 044-27480500 Extn. 84299,87345,85803,85532) during office hours.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.41 MB
GSOCTCESD288Annexure2to4.pdf
Tender Documents • 0.45 MB
GSOCTCESD288TechBidFormsACDFGH.xls
Tender Documents • 0.13 MB
BOQ_937228.xls
BOQ • 0.35 MB
GSOCTCESD288PartOne.pdf
Tender Documents • 3.51 MB
GSOCTCESD288TenderDrawings.pdf
Additional Documents • 1.18 MB
GSOCTCESD288SectionVI.pdf
Tender Documents • 7.35 MB
GSOCTCESD288FormOfAgt.pdf
Tender Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .