| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹50.0 LAccepted-AOC BAGHTOLI P S KHOWANG DIBRUGARH ASSAM PIN 785676 | DIBRUGARH | DIBRUGARH | ASSAM | 785676 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹53.6 L+₹3.6 L (7.11%)Rejected-AOC | L-2 | Rejected-AOC L - 2 Bidder | |
| 3 | L-3₹54.9 L+₹4.9 L (9.75%)Rejected-AOC | L-3 | Rejected-AOC L-3 Bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
27 Nov 2020, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal Secretary
O/o SKAC, Officers Colony By Lane - 3, P.O. C.R. Building, Dibrugarh - 3
Const. of Buuruli Hall and infrastructure dev. at Main Baithow Mandir, Dangori
2020_WPTBC_19290_1
SKAC-03/AO/2017-18/03/8420
Open Tender
Civil Construction Goods
Works
Borpathar, Dangori
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Principal Secretary, SKAC
₹50,000
8 Jan 2021
13 Nov 2020
3 Dec 2020
13 Nov 2020
27 Nov 2020
13 Nov 2020
13 Nov 2020 - 27 Nov 2020
180 days
Amount
CIVIL WORKS : BHURULI HALL
Earth work in excavation for foundation trenches of walls, retaining walls, footings of column steps septic tank etc. including refilling ( return filling) the quantity as necessary after completion of work breaking clods in return filling dressing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In Ordinary Soil
Earth sand filling in plinth in layers not more than 150mm thick necessary carriage watering ramming etc. complete as directed and specified including payment of land compensation forest Royality Sale Tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps walls brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In Prop 1 : 3 : 6
Plain cement concrete floor base in prop 1 : 3 : 6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary and curing etc. completed as directed. i) 35mm thick
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine. (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a Rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. Foundation footing, base of columns pile cap raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams grade beams etc. at or below ground level (ii) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee / L etc. having plane vertical face. (ii) Using 25mm thick plank
Providing brick soling in foundation and under floor with stone / best quality picked Jhama Brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (Protruding M.S. Rod / Tor Steel of column to be embedded in cement mortar and will be measured and paid separately). (A) 112 mm thick brick wall a) In cement mortar in Prop 1 : 4
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match th (a) Any shade or combination of shades using white cement.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Finishing Old / New wall with water proofing weather coat smooth anti – fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.
Supplying fitting and fixing in position reinforcement Bars conforming to relevant I S code for R C C work / R, B walling including straightening cleaning, cutting and bending to proper shapes and length as per details supplying and binding with 20 G annealed black wire and placing in position with proper blocks supports chairs spacers etc. complete (up to 1st floor level) details design complete. a) From Primary Producer : TATA / SAI / Esser Steel / Jindal / Shyam Steel/ RINL (ii) Super Ductile (SD) TMT Reinforcement Bars
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
b) with aqueous emulsion having concentration 1:499 with Premise 350 SC (Imidachloprid 30.5% SC) and water, i.e. 0.07% solution.
ELECTRICAL WORKS :
SOR 1.1 : -Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.1 : Short point up to 3.00 metre. length.
1.1.2 : Medium point up to 6.00 metre. Length.
1.1.3 : Long point up to 10.00 metre. Length.
SOR 1.2 : -Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.1 : Short point up to 3.00 metre. length.
1.2.2 : Medium point up to 6.00 metre. Length.
1.2.3 : Long point up to 10.00 metre. Length.
SOR 1.3 : -Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. 1.3.1 : Short point up to 3.00 metre. length.
1.3.2 : Medium point up to 6.00 metre. Length.
1.3.3 : Long point up to 10.00 metre. Length.
SOR SB1.8 : -Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts ( Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity. B 1.8.1 : With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in surface flat 19 mm casing system
SB 1.8.2 :With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in surface flat 19 mm ISI marked casing 'n' capping system
SOR SB1.9 : -Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts ( Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity. SB 1.9.1 : With 3 x 2.5 sq. mm. + earth continuity with 2x1.5 sq. mm. cable in surface flat 19mm ISI marked casing 'n' capping
SOR 16.2 : -Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.2.1 : B Series (Schneider MG, legrand, Hager make) 16.2.1.1 : 6 to 32A
SOR 15.2: -Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 : ABB, Schneider MG, legrand, Hager make) 15.2.1.4 : 12 way SPN double door
SOR 15.8: -Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1: ABB, Schneider MG, legrand, Hager make) 15.8.1.2: 6 way TPN (4+18) double door
SOR 11.11: -Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required.
SOR .11.29 Supplying and fixing of 150 mm dia (Nominal Size glass globe with anodized aluminium gallery as required.
SOR 22.2: Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free dual pipe technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
CIVIL WORKS : AKHOIFUTUA GHAR
Earth work in excavation for foundation trenches of walls, retaining walls, footings of column steps septic tank etc. including refilling ( return filling) the quantity as necessary after completion of work breaking clods in return filling dressing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level (a) In Ordinary Soil
Earth sand filling in plinth in layers not more than 150mm thick necessary carriage watering ramming etc. complete as directed and specified including payment of land compensation forest Royality Sale Tax and other duties and taxes as may be necessary (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Item No. 3 / 2.1.1 : Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps walls brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In Prop 1 : 3 : 6
Plain cement concrete floor base in prop 1 : 3 : 6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary and curing etc. completed as directed. i) 35mm thick
Providing and laying 25 mm thick damp proof course with cement concrete in prop 1 : 1 ½ : 3 with graded stone agg of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) using Mixer Machine (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a Rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in . Foundation footing, base of columns pile cap raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams grade beams etc. at or below ground level (ii) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee / L etc. having plane vertical face (ii) Using 25mm thick plank
Sides and soffits of beams beam hunching cantilever girders bressumers lintels and horizontal ties. (a) for depth not exceeding 1.0 m (ii) Using 25mm thick plank
Flat surfaces such as soffits of suspended floors roofs landing cantilever slabs chajjas balconies and the like (a) Floors etc. upto 200mm in thickness (ii) Using 25mm thick Plank
Providing brick soling in foundation and under floor with stone / best quality picked Jhama Brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (Protruding M.S. Rod / Tor Steel of column to be embedded in cement mortar and will be measured and paid separately) (A) 112 mm thick brick wall a) In cement mortar in Prop 1 : 4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match th (a) Any shade or combination of shades using white cement.
Providing VITRIFIED floor tiles of approved quality of specified size shape and thickness not less than 18mm on floors, skirting risers and treads of steps over 15mm thick base of cement mortar in prop 1 : 3 including cutting … completed as directed. A) ON FLOOR b) Executive Range Somany / Orient / Nitco / Varmora / VITA / Marbito make. i) Of size 800 mm X 800 mm and above
15mm thick cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises internal rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (b) In Cement Mortar 1 : 4
B) On fair side b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Providing and fixing in position suspended false ceiling using E – Grid (Exposed Ceiling Suspension 2430 System) of Gird size 600 mm X 600 mm / 1200 mm X 600 mm with main runner 38 X 24 mm cross tee 29 mm X 24 mm & wall angle 24 mm X 24 mm. Using 4mm / 6 mm thick High P…… Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade / make over a coat of cement primer before installing it on the Girt.. (A) Standard Ceilling of Everest Make or Equivalent as directed by the department. ii) Using 6 mm thick F.C. Board. FF celling
Providing pre painted galvanized Iron sheet roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately) TATA Blue scope / Dyna roof / Durako. (iv) 0.55 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.55 mm thick
Providing wood work in frame (Chowkaths) of Door Window C / Window and other similar works wrought, framed and fixed in position in contact with C.C. or brick masonry wall including supplying fitting and fixing with M.S. Hold fast (40 mm X 3 mm X 250 mm ) as per design embedded in cement concrete block in proportion 1 : 2 : 4 and with two coats of kiricide oiling to the timber faces in contact with C.C. and masonry as directed and specified. (b) With 1st Class Timber
: Providing fitting and fixing full paneled doors / windows including oxidized M.S. Butt Hinges (100mm X 75 mm X 3.55 mm) with necessary screws (other fittings to be measured and paid separately) B) With 1st Class Local Wood ii) 35mm thick
Providing fitting and fixing anodized aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant I.S specifications) and providing and fixing handles angle completed as directed. (b) 3 Track Sliding Window i) 6 mm clear glass
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concerete / mortar walls and ceiling both internal and external ) after removing all loosely adhering material from the wall surface with the help of emery stone, etc. completed as directed. (i) 1.5 mm thick
m) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. (i).Priming coat with distemper primer
(ii). Top coat
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Finishing Old / New wall with water proofing weather coat smooth anti – fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Supplying fitting and fixing in position reinforcement Bars conforming to relevant I S code for R C C work / R, B walling including straightening cleaning, cutting and bending to proper shapes and length as per details supplying and binding with 20 G annealed black wire and placing in position with proper blocks supports chairs spacers etc. complete (up to 1st floor level) details design complete. a) From Primary Producer : TATA / SAI / Esser Steel / Jindal / Shyam Steel/ RINL (ii) Super Ductile (SD) TMT Reinforcement Bars
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing and fixing stainless steel ( Grade 304) railing made of Hollow Tubes, Channels, Plates etc. including welding, grinding, buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer I – charge. (For Payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessoried such as nuts bolts, fasteners etc. will be considered)
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
b) with aqueous emulsion having concentration 1:499 with Premise 350 SC (Imidachloprid 30.5% SC) and water, i.e. 0.07% solution.
ALUMINIUM FITTINGS : Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished) a) Sliding door bolts i) 300mm x 16mm
ii) 250mm x 16mm
b) Tower bolts i) 300mm x 12mm
iii) 200mm x 12mm
c) Door handles iii) 150mm
m) Mortice lock vertical type iv) Aldrop with In built Lock-6 lever kadi tala(Godrej Make)
r) Curtain rod ii) 25mm x 2mm
t) Door stopper with rubber stopper
ELECTRICAL WORKS :
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point up to 6.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system . With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
SOR 16.2 : -Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.2.1 : B Series (Schneider MG, legrand, Hager make) 16.2.1.1 : 6 to 32A
SOR 15.2: -Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 : ABB, Schneider MG, legrand, Hager make) 15.2.1.4 : 12 way SPN double door
SOR 15.8: -Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1: ABB, Schneider MG, legrand, Hager make) 15.8.1.2: 6 way TPN (4+18) double door
SOR SB.8.49: -Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SOR 27.1: Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.6 - Standard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO mak
SOR 27.2: Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 27.2.1.3 - High Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), Ventil Air DX 250 mm sweep Louver type (Havells make)
SOR 11.11: -Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required.
SOR 22.2: Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free dual pipe technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Sleek Extruded Aluminium Channel type luminaries complete with ribbed extruded diffuser & aqua coloured flushed end caps and Electronic ballast / Channel type luminaries complete with bright aluminium reflector & decorative silver coloured end caps and Electronic ballast with 1 X 36 watt Fluorescent tube. (Crompton Greaves make) Model- DZL36EB DAZZLE with Super Saver Lamp/ DMLUR14EB SPARKLER with Power Lux Lamp or equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make.
CONST. OF PERIPHERIAL ROAD AT SITE.
Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.) a) from Private land
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (b)Using Grading II material
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (B) ADOPTING CROSS WISE DOUBLE ROW PLANTING METHOD (i) With Duranta
CONST. OF PAVILLION FOR DEVOTEES
Earth work in excavation for foundation trenches of walls, retaining walls, footings of column steps septic tank etc. including refilling ( return filling) the quantity as necessary after completion of work breaking clods in return filling dressing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level (a) In Ordinary Soil
Earth sand filling in plinth in layers not more than 150mm thick necessary carriage watering ramming etc. complete as directed and specified including payment of land compensation forest Royality Sale Tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps walls brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In Prop 1 : 3 : 6
Plain cement concrete floor base in prop 1 : 3 : 6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary and curing etc. completed as directed. i) 35mm thick
Providing and laying 25 mm thick damp proof course with cement concrete in prop 1 : 1 ½ : 3 with graded stone agg of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a Rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in . Foundation footing, base of columns pile cap raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams grade beams etc. at or below ground level (ii) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee / L etc. having plane vertical face (ii) Using 25mm thick plank
Sides and soffits of beams beam hunching cantilever girders bressumers lintels and horizontal ties. (a) for depth not exceedin (ii) Using 25mm thick plank
Providing brick soling in foundation and under floor with stone / best quality picked Jhama Brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dew (b) In proportion 1:4.
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match th (a) Any shade or combination of shades using white cement.
Providing VITRIFIED floor tiles of approved quality of specified size shape and thickness not less than 18mm on floors, skirting risers and treads of steps over 15mm thick base of cement mortar in prop 1 : 3 including cutting … completed as directed. A) ON FLOOR b) Executive Range Somany / Orient / Nitco / Varmora / VITA / Marbito make. i) Of size 800 mm X 800 mm and above
15mm thick cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises internal rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Providing and fixing in position suspended false ceiling using E – Grid (Exposed Ceiling Suspension 2430 System) of Gird size 600 mm X 600 mm / 1200 mm X 600 mm with main runner 38 X 24 mm cross tee 29 mm X 24 mm & wall angle 24 mm X 24 mm. Using 4mm / 6 mm thick High P…… Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade / make over a coat of cement primer before installing it on the Girt.. (A) Standard Ceilling of Everest Make or Equivalent as directed by the department. ii) Using 6 mm thick F.C. Board.
Providing pre painted galvanized Iron sheet roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately) TATA Blue scope / Dyna roof / Durako. (iv) 0.55 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.55 mm thick
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concerete / mortar walls and ceiling both internal and external ) after removing all loosely adhering material from the wall surface with the help of emery stone, etc. completed as directed. (i) 1.5 mm thick
Finishing Old / New wall with water proofing weather coat smooth anti – fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Supplying fitting and fixing in position reinforcement Bars conforming to relevant I S code for R C C work / R, B walling including straightening cleaning, cutting and bending to proper shapes and length as per details supplying and binding with 20 G annealed black wire and placing in position with proper blocks supports chairs spacers etc. complete (up to 1st floor level) details design complete. a) From Primary Producer : TATA / SAI / Esser Steel / Jindal / Shyam Steel/ RINL (ii) Super Ductile (SD) TMT Reinforcement Bars
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
b) with aqueous emulsion having concentration 1:499 with Premise 350 SC (Imidachloprid 30.5% SC) and water, i.e. 0.07% solution.
ELECTRICAL WORKS :
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Medium point up to 6.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts ( Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity. B 1.8.1 : With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in surface flat 19 mm casing system
SB 1.8.2 :With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in surface flat 19 mm ISI marked casing 'n' capping system
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts ( Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity. SB 1.9.1 : With 3 x 2.5 sq. mm. + earth continuity with 2x1.5 sq. mm. cable in surface flat 19mm ISI marked casing 'n' capping
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.2.1 : B Series (Schneider MG, legrand, Hager make) 16.2.1.1 : 6 to 32A
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 : ABB, Schneider MG, legrand, Hager make) 15.2.1.4 : 12 way SPN double door
Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.6 - Standard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO mak
Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required.
Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free dual pipe technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Sleek Extruded Aluminium Channel type luminaries complete with ribbed extruded diffuser & aqua coloured flushed end caps and Electronic ballast / Channel type luminaries complete with bright aluminium reflector & decorative silver coloured end caps and Electronic ballast with 1 X 36 watt Fluorescent tube. (Crompton Greaves make) Model- DZL36EB DAZZLE with Super Saver Lamp/ DMLUR14EB SPARKLER with Power Lux Lamp or equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make.
Niranjan Saikia
ABHIJIT SONOWAL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .