| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-Finance 90 E B C ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-Finance Offer lowest bid therefore provisional order issued | |
| 2 | L2₹24.6 L+₹3.5 L (16.8%)Rejected-Finance 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹24.9 L+₹3.8 L (18.1%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹25.0 L+₹3.9 L (18.7%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L4 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
20 Aug 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNHED PW DTE
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Up gradation of IB 3 Ward in to 35 bedded CCU of ID BG Hospital Kolkata E I Work
2021_WBPWD_338567_1
WBPWD/EE/KNHED/NIQ-70/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹50,000
Yes
25 Aug 2021
2 Aug 2021
23 Aug 2021
4 Aug 2021
20 Aug 2021
4 Aug 2021
120 days
Amount
Supplying and delivery of 1.1 KV grade 4 core 50 sqmm armoured Alminium XLPE cable on wall as per G.S. (Make: Gloster/Havells/Polycab)
Laying of 4 core 50 sqmm cable with suitable size GI wire.
Supply and fixing compression type gland For 50 sqmm 4core complete with brass gland brass ring and rubber ring for dust and moisture proof entry of XLPE/PVC armoured cable.
Finishing the end of following XLPE/PVC armoured cables bycrimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials For 50 sqmm 4core
Supplying and fixing double door 8 way Vertical TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(as per Make: Legrand/L&T AU/ABB/ Siemens ) INCOMING- Supplying and fixing 415 V, 250A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection -1No.(Make:Legrand) OUTGOING- Supplying and fixing 240V 63A TP MCB of Breaking capacity 10kA & C characteristics on 1din rail of existing DBs and necessary connection-8 nos. .(Make: Legrand/L&T/Siemens)
Supplying and fixing 415V 6/10A, 8 way TPN MCBDB (Legrand/L&T AU make) comprising with of 1no. 63A FP Isolator and 24 nos, (6- 32)A SP MCB with cable end box double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 230V 6/10A, 2+10 way SPN MCBDB (Make: Legrand) comprising of 1no. 40A DP Isolator & 10nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supplying & fixing double door SPN MCB Distribution board with IP-42/43 protection , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter comnnection with sutiable size of copper wire and neutral link & provision for earthing attachment 2+8 way Enclosure (607711) make- Legrand / L&T
Supplying & fixing double door SPN MCB Distribution board with IP-42/43 protection , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter comnnection with sutiable size of copper wire and neutral link & provision for earthing attachment 2+4 way Enclosure (607710) make- Legrand / L&T
S&F (10" x 8 " ) MS Board (Loop Box) with single door system deep 5 inch. With 1 no. channel for 4 pole MCB insulation on wall including necessary interconnection complete
S & F of 240/415 V, 63 A 4pole MCB isolator on din rail of existing DBs & necessary connection ( make- Legrand, / L&T
Cost of iron clamp 8"x12" x1' for laying PVC conduit over the existing laying cable on wall as per GS
Supply & fixing of 3 ph timer for controlling 1 no. 3-ph A.C. MC(consealed split) of size 11.00 Tr. Consisting of the following a) 14 inch. X 12 inch x 6 inch. -double door MS Box b) Astronomical Timer , -999 hrs. (make-Siemens/L&T ) , Cat No. 7PV07321AV20) , C) 4P MCB 415V/63A-1 NO.(make-Siemens/L&T) , Cat no. 5TL44327RC , d) 4P Isolator 1no.(make-Siemens/L&T) , Cat no. 5TL13320 , e) 4 pole power cotactor of required rating -2 no. (make-Siemens/L&T) , Cat no. MNX701597076 type , f) DB locking arrangement must be there , g) 6A MCB , h) Push bottom ON/OFF switch indivisual outer side of DB (There must be bypass mechanism and indication for ON/OFF by indicating lamp of the AC m/c unit attached to it )(For double Air-Conditioner Machine )
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 200x50x1.25mm (18SWG)
Distn. Wiring in 1.1 Kv gr. Single core stranded ‘FR’ PVC insulated & unsheathed cu. wire (Approved make RR Cable/Polycab/Finolex) in 20/32/40 mm size PVC rigid conduit ‘FR (precession) incl. necy. Fitting as reqd. a) 2 x1.5 sqmm + 1x 1.5sqmm for ECC
b) 2 x2.5 sqmm + 1x 1.5sqmm for ECC
c) 2 x 4 sqmm + 1 x 2.5 sqmm for ECC
d) 2 x 6 sqmm + 1 x 4sqmm for ECC
e) 4 x 6 sqmm + 2 x 4 sqmm for ECC
f) 4 x16 sqmm + 2 x 10 sqmm for ECC
g) 4x 35 sqmm + 2 x 16 sqmm for ECC
Finishing end of copper wire and PVC/Al cable of the fol;owing sizes by crimping method as per GS a) 35 sqmm
b) 16 sqmm
c) 10 sqmm
d) 6 sqmm
e) 4 sqmm
f) 2.5 sqmm
g) 1.5 sqmm
S & F indoor 18 Watt Round type LED Fittings complete on false celing with necy. Connetion asper direction of EIC.(Make Philips cat no-D395BLED200S-3000PSRWH /Crompton Greaves )
Supply of 1420 rpm 240V AC Heavy duty 12’’ Exhaust Fan (Make : EPC/CG/Cinni)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S&F separate plug board of size 175 x 100 x 65 mm M.S. Box comprising with 2 Nos. 250 V 5 pin 6A plug socket with 2 Nos. 6A piano key type switch(Anchor /Vinay Make) and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S & F 240V, 3 nos. 16A Plug socket ( Anchor,black) & 3 nos. 6A plug socket ( Anchor,black) with separate 3 nos. 16A Piano key type switch( Anchor,black) & 3 nos. 6A Piano key type switch (Anchor,black),240V LED indicator( colour- Green, make -L&T, cat no-EPLR240A) & 16A switch type SP MCB (legrand / havells) on sheet metal switch board embedded in wall incl. S & F 415 mm x 200 mm x 65 mm MS (16SWG ) Switch board and bakelite top cover ( Blue) of 3 mm thick by brass screws after making housing for switch by cutting bakelite cover and making necy connection for CU. wire as required.( For UPS board)
S&F 415V, 63A TPN On load front operated change over with SS enclosure (Make : L&T, Cat. No. CO106300SOO) on angle iron frame on wall fixed for heavy type GI Z clamp with fastner incl. S&F 3 nos. DIN type HRC fuse with S&F special type 2 nos. SS Cable end box (16 SWG) of suitable size for incoming & outgoing cable fixed at both end of SFU with nut, bolt & washer etc. incl. powder coated painting as per direction of EIC
S & F 220 V 32A SP MCB ( Legrand, C - Curve), 32A, 2P+E (Make: L&T,cat no DBMPS332SD) Industrial plug & socket including 32A industrial top ( make- L&T, cat no- MPS332P) on conceal wall at negative presure motor with necy. Connection as per GS
S&F 415V, 250A TPN SFU with SS enclosure (Make : L&T, Cat. No. SK90489) on angle iron frame on wall incl. S&F 3 nos. DIN type HRC fuse with S&F special type 2 nos. SS Cable end box (16 SWG) of suitable size for incoming & outgoing cable fixed at both end of SFU with nut, bolt & washer etc. incl. powder coated painting as per direction of EIC
Supply & fixinng 240 V, interval timer for exhaust fan consistung ON/OFF toggle switch, indicator, 4 way connector & 2 hrs ON & 30 minits off condition fixed in 7 '' x 4'' wooden board including s & f wooden board as per direction of EIC. (Elektra)
S & F of 415V, 100 A 4Pole battery terminal/stud with nut,bolt & washer etc. as per direction of EIC.
Supply & instaallation 20 KVA (input 3PH /OutPut 3 Ph) Full Load PF: 0.9 true on line -Double Conversion IGBT Based Modular UPS System With External isolation Transformer & 30 Mins SMF Battery Back-up ,Power Cabinet With 3 nos of 6.66 KVA or 2 nos. of 10 KVA Module to be equiped with ambient temperature
Input Voltage :-380-415 V ,O/P Voltage -380-415 V .Input Frequency :-50 Hz +/-0.1%in free runing & +/-4% in Sync , Wave Form :-Sinusoidal. Minimum Backup at Rated Load - 30 Min ,Over Load :110% for 10 Min, 125% for 4 Minute .
Rippel:less than 2% ;Inverefficiency :>93% ,Battery 12 V Total VAH 18720 (or As Suitabel minimum 30 min Battery Back at rated Load) SMF Battery (VRLA) - Make-Exide/Amar Raja(Quanta) with minimum 2 years warranty;
Input/Output Terminal Conection :3P + N + PE Connection . Protection:-Input/Output over Voltage ,under voltage,singel phase protection ,DC High under/over voltage ,Battery Charging Over Current ,Output Over load/Short Circuit Oveer temp.
Ups autoon on Mains recovery ,Audio alarm mains fail , Battery Low,pre Alarm Inverter trip ; METERING:-LCD Display for input/Output -Voltage, Frequeency ,Current,battery Voltage & Current
Switch gear :-MCB/MCCB for input ,Battery ,Output Manual Bypass Switch ; Noise Level :<75 Db at 1 mtr distance ;Protection Degree:-IP 21;Cooling -Forced Air ; Standard Warranty :-2 years on site repair or replacement ,
Standard Warranty :- 2 years on site repair or replacement,Start up service ,Make-Numeric/AVO/APC/Emmersion
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
SILICON SOFTWARE
M/s Singh Electrical Works
Electromech Engineers Co-Operative Society Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .