Loading…
Loading…
Tender Value
₹53.6 L
EMD Value
₹1.1 L
Closing Date
1 Sept 2026, 3:00 pm4d left
EE,ELD-9,DDA
EE,ELD-9,DDA
SITC of street lights on the service lane from Helipad to Pansali Chowk at Sector -31 and 32 road,Rohini.
2026_DDA_923759_1
23/EE/ELD-9/DDA/NIT/ 2026-27
Open Tender
Electrical Works
Works
45 days
ROHINI
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹1.1 L
27 Aug 2026
27 Aug 2026
2 Sept 2026
27 Aug 2026
1 Sept 2026
27 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Octagonal Steel Pole Supplying, installation, testing and commissioning of hot dip galvanized octagonal steel pole of 9 Mtr. height and made of 3 mm thick sheet, having bottom 155 mm OAF & top 70 mm OAF, hot dip galvanized M.S base plate of size 260 mm x 260 mm x 16 mm thick, single overhang bracket made of 3.60 mm thick hot dip galvanized M.S. pipe with 1.5 Mtr. long tube of suitable dia to accommodate the pole & fittings, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. GI Sleeve on connector box made out of 3mm thick MS sheet 250 mm wide duly welded with existing connector box cover of pole complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:-
(a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.
(b) 4 nos. 40 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet.
(i) 16 sq mm conductor – 4 nos and short links 5-nos.
(ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire.
(c) 6 Amp SP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc.
(d) Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required. | - | Each | 20,635 | - |
| 1.1 | Foundation nuts & bolts | - | - | - | - |
| 2 | Providing and laying in position, M25 reinforced cement concrete foundation of size 500mm long x 500mm wide and 1400 mm deep i/c excavation of earth, refilling, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1500 mm long (approx.)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2000 mm long (approx.)-8 Nos. (With approx. 150 mm spacing) i/c centering & shuttering as required, positioning of foundation bolts 4 nos. M-24x750mm long foundation bolt of L Type (100 mm bend & 750 mm straight), 150 mm top threaded portion of bolt shall be galvanized and rest portion shall be coated with Red oxide to avoid corrosion & G.I nuts (EN 8-grade) with 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 260 mm x 260 mm x 3 mm thick shall be supplied manufactured from the original pole manufacturing company only for casting of foundations and providing 63 mm (OD) 2 Nos. DWC pipe 1 mtr long approx. each for cable entry and exit etc complete as required. | - | Set | 10,304 | - |
| 2.1 | Lighting Fixture | - | - | - | - |
| 3Supplying, installation, Testing & Commissioning of following wattage Street light LED fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >70 , under voltage and overvoltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 3.1 | 120 Watt | - | Each | 4,066 | - |
| 3.2 | Wiring from pole control box to light fitting(s) | - | - | - | - |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor Single core cable in the existing surface/recessed steel/PVC conduit/ Pole as required.
a) 3 x 1.5 Sq.mm | - | Mtr. | 104 | - |
| 4.1 | Cables & cable laying | - | - | - | - |
| 5Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.19 MB
BOQ_970734.xls
BOQ • 0.32 MB
NIT23.pdf
Tender Documents • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].