Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
2 Mar 2026, 3:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Provision of CCTV facility in 10 goods sheds over Solapur division
SUR-C-WKS-CCTV-GDS-SHED
SUR-C-WKS-CCTV-GDS-SHED
Open
6 Months
Solapur, Maharashtra
₹0
₹2.2 L
6 Feb 2026
6 Feb 2026
16 Feb 2026
01-Provision of CCTV facility in 10 goods sheds over Solapur division
Supply of wall mount 6U Rack Enclosures Networking/ Server Rack with power strip 01 5A socket 06 no. & MCB, Depth of the Rack: Upto 600mm, Transparent Toughened Glass used in front door, CRCA Steel rear door, with Secure Locks, Support cable entry from top or bottom, with fan tray and two nos. fans suitable for outdoor installation (IP 68 rated) make: Valrack/ Dyanamic Rack/ Digilink/ similar, Inspection: Consignee
Supply of STP (shielded Twisted Pair) CAT-6 cable, the cable should be compliant to EIA/TIA 568 B/C standards from D-Link, Finolex., Lucent or DAX Make (1Box-305 mtrs) (Inspection by Consignee)
Supply of FR CAT-6 UTP Cable suitable for 10 BASE-T/100BASETX/and 1000BASE- T(Gigabit Ethernet). Make: DLINK/ AMP/ Avaya/ Krone/ Bestnet/ Ambernet Inspection: Consignee
Supply of CAT-6 UTP RJ-45 patch cord (5mtr long) twisted stranded cable terminated 04 with RJ45 modular plugs at both the ends. TIA/EIA-568-C.2 standard,Insulation Material : High Density Polyethylene, Outer Jacket: FR-PVC,Conductor diameter: 24 to 26 AWG,Conductor Metal : Bare Copper, Make D-Link/Similar, Inspection: Consignee.
Supply of Gigabit Ethernet Media Converter Single Mode Single Fiber, SM, Sc, 1310 05 nm, Transmission Type: 10/100/1000MFDX/HDX, Wavelength: Single mode: 1310/1550nm up to 20Km, Power Supply: External 1A,+5VDC, Connector: UTP: RJ-45 connector, Optical: SC connector (Single Fiber), with all accessories like power adaptor, make: JT Optics /Digisol/ TPLink / similar. Inspection: Consignee
Supply of FRLS power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable asper IS-694:2010 or latest, make :Havells /Polycab /Finolex/Similar. Inspection:Consignee
Supply of 8 ports Gigabit Managed PoE+ Layer 2 Access 19 inch rack mountable switch with two Gigabit SFP ports duly OEM loaded from Cisco or HP or Juniper or Extreme. (Inspection by Consignee)
Supply of (cable nails) 12mm dia wire fastener circle cable clips with metal nail, set of 100nos. Make: Hi-plast or ssimilar. Inspection: Consignee.
Supply of 1KVA Online UPS with min. 30 minute back up along with 03 Nos.12v/26Ah external battery (Quanta/ Exide) with terminal & accessories set. Model: Liebert GTXMT + CX1KVA (800W) UPS, Make: Emerson Liebert (Vertiev)/ APC/ Numeric. Inspection: Consignee.
Supply & fixing of Round PVC Passive Networking Flexible Pipe, 01- inch Dia, Zig Zag Outer Surface Pattern, Round Shape, with ISI Mark, make: Dutron/ TMT Plus/ similar Inspection: Consignee.
Supply of flame retardent PVC conduit pipe (lSl Mark), 25mmx1.5mm, This includes all required fixing materials such as screws, nut & bolts, washers, clamps, elbow, Tee, etc. make: Anchor/ AKG/ Precision/ Polycab/ similar Inspection: Consignee.
Running, laying of power cable/ data cable/ cat-6 cable through pvc pipes as per site engineer's instruction. All fixing material to be arranged by contractor.
Supply of Fire-retardant and corrosion-free 25x25/32/38 MM PVC Casing Capping, make Pressfit /PRESTO/ SGI/ similar, Inspection:Consignee.
Fixing of PVC conduit pipe on wall, bridges, platform shed complete with 'U' clamps and necessary fixture screws etc as per route given by site engineer of Railways.
Supply of 2 MP EXIR VF Bullet Network Camera, Image Sensor : 1/2.7" Progressive Scan CMOS, Resolution : 1920 x 1080, Lens Type : Fixed lens, 2.8/4 mm, Aperture: F2.0, IR Range : Up to 30 m, video Resolution : 1920 x 1080, Video Compression : Main stream :H.265 +/ H.265/H.264+/ H.264, Sub-stream :H.265 /H.264/ MJPEG, Audio ompression :G.711/ G.722.1/ 15 G.726/MP2L2/ PCM, Basic Event : Motion detection, video tampering alarm, exception (illegal login), Image Enhancement : BLC, 3D DNR, Day/Night Switch : Day/ Night / Auto/Schedule, Protocols : TCP/IP,ICMP, HTTP, HTTPS, FTP,DHCP, DNS, RTP, RTSP, RTCP, NTP, IGMP, QoS, UDP, API : ONVIF (PROFILE S,PROFILE G), ISAPI, SDK, Communication Interface : 1 RJ45 self-adaptive Ethernet port, Audio : 1 audio input (built-in microphone), mono sound, Power Supply :12 VDC 5.5 mm coaxial power plug;PoE,IP66, Built-in microphone, make: Hi vision/CP Plus, model: Hikvision DS-2CD1023G0- IU/ Similar.Inspection: Consignee.
Supply of 2MP IP Dome Camera, Image Sensor : 1/2.7" Progressive Scan CMOS, Day & Night : IR cut filter, Digital Noise Reduction : 3D DNR, Focal Length : 2.8/4mm fixed lens, Aperture :F2.0, Focus :Fixed, IR Range : Up to 30 m, Video Compression : Main stream :H.265 +/H.265/H.264+/H.264, Max. Resolution : 1920 x 1080@ 30fps,communication Interface : 1 16 RJ4510M/100M self-adaptive Ethernet port, Audio : 1 audio input (built-in microphone),mono sound, Audio Compression:G.711/G.722.1/G.726/MP2L2/PCM, Power Supply : 12 VDC, 5.5 mm coaxial power plug PoE, IP67, IP66 Built-in microphone, Basic Event : Motion detection, video tampering alarm, exception (illegal login),Image Enhancement : BLC, 3D DNR, Day/Night Switch :Day /Night/ Auto/ Schedule, make: Hikvision/CP PLUS/similar, model: HikvisionDS-2CD1323G0-IU/similar, Inspection:Consignee.
Supply of 8 Channels DVR/NVR with 4K(3840 x 2160), IP video input : 8-chIncoming band width : 80 Mbps, Outgoing bandwidth : 160 Mbps, HDMI output resolution : 4K (3840 x 2160)/30Hz, VGA output e solution : 1920 x 1080/60Hz,Audio output : 1-ch, RCA, Decoding format: 17 H.265/H.265+/H.264/H.264+/MPEG4,Recording resolution : 8MP, Synchronous playback : 8-ch, Capability : 2-ch @ 4K,SATA : 2 SATA interfaces, Capacity : Up to6TB capacity for each HDD, Network interface : 1, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, USB interface : Front panel: 1 x USB 2.0; Rear panel: 1 x USB 3.0, Alarm in/out : 4/1,Power supply : 12 VDC, Make: Hikvision/CPPLUS/similar, Model: Hikvision DS-7P08NI-K2/ equivalent. Inspection: Consignee
Supply of 16 Channels NVR with 4K (3840x 2160), H.265/ H.265+/ H.264/ H.264+/ MPEG4 video formats, Connectable to the third-party network cameras, Recording at up to 8 MP resolution, HDMI and VGA independent outputs, HDMI Video output at up to 4K (3840 x 2160) 18 resolution, Up to 2 SATA interfaces connectable for recording and backup, 1 self-adaptive 10 M/100 M/ 1000 Mbps network interface, Connectable to IP cameras from Hikvision and the recording, playing back, and backing up of VCA alarms, Centralized management of IP cameras, including configuration, information import/export, real-time information display, two-way audio, upgrade, etc., IP video input : 16-ch, Incoming bandwidth : 160 Mbps, Outgoing bandwidth : 160 Mbps, Audio output : 1-ch,RCA, Decoding format : H.265/H.265 +/H.264/H.264 +/MPEG4, Synchronous playback : 16-ch, Capability :2-ch @ 8 MP (25fps), SATA : 2 SATA interfaces, Capacity : Up to 6 TB capacity for each HDD, Two-way audio : 1-ch, RCA (2.0 Vp-p, 1k), Network interface : 1, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, USB interface : Front panel: 1 x USB 2.0; Rear panel: 1 x USB3.0 Alarm in/out : 4/1, model: HikvisionDS-7616NI-K2/similar, make: Hikvision/ CPPLUS/ similar, Inspection: Consignee.
Supply of Professional Large Format Display, Size 138 cm Wi-FI Screen Share Hot Spot Screen Brand: LG or NEC or Sony or Samsung with 3 years onsite warranty and interfacing equipment for IPIS system at the station under installation.
Supply of 4TB Windows Surveillance Hard Disk, RAM Size: 4 GB, Memory Type: DDR3 SDRAM, Hard Drive Size: 4TB, Hard Drive Interface: Serial ATA, Rotational Speed:5400 RPM, Wattage: 5 Watts, Make:Toshiba/ WD/ Seagate. Inspection:Consignee.
Installation, testing, commissioning of CCTV System & fixing of camera, at various locations as per instruction of site engineer.
Supply of Permanent Lubricated HDPE Telecom duct of size 50/42mm and 22 accessories as per latest specification TEC GRNo.GR/TX/CDS-008/03/ March11 with latest amendment for OFC cable of size 24/6 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources.(Inspection by Consignee)
Laying of HDPE duct in trench and its protective work as per direction of site engineer.
Supply of GI pipe, inner dia.100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA, JINDAL/ ZENITH BIRLA make. (Inspection by Consignee)
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Over head laying of 6-core OFC cable including clamping along the wall/fob structure as per instruction site engineer.
Supply, Transporting and installation of concrete (RCC) route indicators at intervals 27 of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC.In case of Telecom quad cable joint locations it shall be painted with RED colour. (Inspection by Consignee)
Supply of Optic Fibre Cable 6 Core (Singlemode) armoured, as per TEC Spec. TEC/GR/OFC02/03.Sep.2003 or latest, Make: Finoles cables/ Usha martin/ Sterlite/ Vindya Telelinks/ West coast/ Birla Cables, Inspection: Consignee.
Supply of 12 port LIU, 19 in chrack mountable as per following specification: a) It should have12 SP type ports for termination of SM optical fibres. b) It should be rack mountable with 29 1U height. c) It should be equipped with front managed saddle for jumper/patch cord management. d) It should have12 SC termination. e) It should be equipped with adequate nos.of splicing trays to splice 12fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex make.(Inspection by Consignee)
Installation & commissioning of 12 port LIU with all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. as per requirement. The splice trays shall be placed and secured into the LIU after licing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions.
Supply of optic fiber pigtails for termination of OFC cables with following specification: 31 a) It shall be single mode SC/SC type with push pull mechanism or as per site requirement and fully compliance with latest industry standard. b) It shall have length of 2 Meters at least. c) It shall have SC connector at one end and other shall be loose for splicing. d) It should be of reputed make D-Link or 3M or Digilink or Molex.(Inspection by Consignee)
Splicing/ dropping/termination of each fiber/ pigtail in LIU/IO box/ terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the 32 already fixed LIU. iii) Each of the fibre shall be spliced with a pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber /pigtail shall be properly marked with necessary ferrules/ tags.vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers. viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records.
Maintenance free earth as per RDSO/SPN/197/2008 or latest consisting of: (1) Copper 33 bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sqmm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO
Installation of unit earth as per RDSO/SPN/197/Ver 1 or latest,to construct earthing of </= 1Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of 34 earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor.
Supply & Installation of Router with all accessories (Technical specification as per attached annexure-A). Inspection: Consignee.
Excavation of trench in all kinds of soil (1.0mtr. Depth 300 mm width) and refilling of the trench without Bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. This work includes clearing of route from bushes etc, covering of cable 36 laid in trench by loose soil for a layer of 50mm thickness approximately. Note: Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in aspan of 100 mtr. of shorter lengths along the cable run, minimum depth will be taken for that particular stretch for payment. Prior permission should be taken before laying of cable if the depth of trenching isless than 1.0 Mtr. Inspection: Consignee.
Boring under Metalled Road/Railway track for crossing of Telecom cables. Boring to be done for crossing road/rail at 1.5 mtr depth & after boring min. 2/4" dia G.I pipes are to be inserted & cable to be laid through the pipes.
Cutting of all types of Roads/ platforms preparatory to trenching and excavation to 38 depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.
Where ever depth of 0.5 m cable trench is not feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
of High throughput LAN extenders as per RDSO specification. (Inspection by Consignee)
Supply & installation of independent iron (galvanized) structure post (100 mm) of min. 15 feet in length including water proof protecting arrangement with canopy for cctv including painting & erection. Inspection: Consignee
Provision of application software for Android and iOS devices to monitor the operation of these GS services round the clock with necessary client license of 100 user for operational life of the CCTV system.
"Supply, Installation, Testing & commissioning of Full HD Resolution PTZ (Pan, Tilt, Zoom) IP Colour Camera with varifocal lenses along with housing and mount with all accessories as per RDSO specification No. RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection by RDSO. "
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SURTENDERDOCFORCCTVINGOODSSHED06.02.2026.pdf SUR TENDER DOC FOR CCTV
ATTACHMENT
GCC-2022-uptoACS10_2.pdf
ATTACHMENT
SURTENDERDOCFORCCTVINGOODSSHED06.02.2026.pdf
ATTACHMENT
GCC-April2022_merged20.05.2024.pdf
ATTACHMENT
Download all tender documents and submit your bid