Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC NH 148 B NEAR BABA GHISARAM FILLING STATION VILLAGE PALI MAHENDERGARH 123029 | MAHENDERGARH | MAHENDERGARH | HARYANA | 123029 | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 Cr+₹29.3 L (18.7%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹1.9 Cr+₹29.3 L (18.7%) | L2 | Rejected-Finance L2 |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
26 Aug 2022, 5:00 pmClosed
Executive Engineer Elect. Div PWD B and R Hisar
Executive Engineer Elect. Div PWD B and R Hisar
CONSTRUCTION OF ADDITIONAL ADMINISTRATIVE BLOCK IN MINI SECTT. COMPLEX AT BHIWANI (PDG. E.I INTERNAL ONLY)
2022_HRY_233833_1
Elect-GGN/Elect-HSR/100344
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹3.4 L
10 Nov 2022
12 Aug 2022
29 Aug 2022
12 Aug 2022
26 Aug 2022
12 Aug 2022
Amount
Copper Wiring in with Modular Switches in MS Conduits (HSR 23.2) Wiring for Light/Fan/Call bell point with modular type switch/socket and GI box, Modular type face plate etc. in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. (HSR 23.2.1) Group C (HSr 23.1.1.3)
Wiring for Twin control light point with 2 Nos. 2 way, 5 amp. modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe.(HSR 23.2.2) Group C (HSR 23.2.2.3)
Wiring in MS conduit system for 3 pin 5 amp. plug point by using 2 no. 1.5 sqmm FRLS copper wire and 1 No. 1.5 Sqmm FRLS Copper wire including providing 1 no. 5/6 Amp 3/5 pim modular type socket and 1 no. 5/6 Amp Modular type switch required GI Box, Modular face plate etc. complete as required.(HSR 23.2.4) Group C (HSR 23.2.4.3)
Wiring in MS conduit system for 3 pin 15 amp. plug point by using 2 no. 4 sqmm FRLS copper wire and 1 No. 4 Sqmm FRLS copper wire for earthing, including providing 1 no. 15/16 Amp 3/6 pin Modular socket and 1 no. 15/16 Amp Modular switch required GI Box, Modular face plate etc complete as required (HSR 23.2.5) Group C (HSR 23.2.5.3)
Supply and Erection of MS conduit pipe 1.6 mm thick, ISI marked surface / recessed in slab / wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. (HSR 23.6.6) M S Pipe of 20 mm dia (HSR 23.6.6.1)
M S Pipe of 25 mm dia. (HSR 23.6.6.2)
Supply and erection of PVC Conduit ISI mmarked (Medium) recessd in wall/ceiling etc. including the cost of PVC bends, inspectyion boxes, iron hooks and cement concerete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR 23.7.6) PVC pipe of 25 mm dia (HSR 23.7.6.2)
Supply and erection of 10.5 cm dia MS Fan box including 8 mm dia 30 cm long MS road made into suitable suspension hook and erected in RCC slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respect. (HSR 23.8.10) 1 & 2 Modeules including combined plate for telephone and data. (HSr 23.8.10.1)
3 Modules (HSR 23.8.10.2)
4 Modules (HSR 23.8.10.3)
6 Modules (HSR 23.8.10.4)
8 Modules (HSr 23.8.10.5)
12 Modules (HSr 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.(HSR 23.8.11) Call bell 220/230 volts musical type (HSR 23.8.11.6)
Bakelite angle / straight button holder large size. (HSR 23.8.11.2)
Bell Push (HSR 23.8.11.6)
Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)
Telephone Socket outlet modular type (HSr 23.8.11.8).
Erection of Exhaust fan in existing opening, complete with necessary earthing of Fan including carriage from PWD store to the site of work. (HSR 23.9)
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.(HSR 23.20)
MCCB, Distribution Boards, MCB's, RCCB's, Change Over etc. (HSR 23.22) Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.1) TRIPLE POLE MCCB 16 to 100 Amp (HSR 23.22.1.3)
TRIPLE POLE MCCB 125 to 160 Amp (HSR 23.22.1.4)
TRIPLE POLE MCCB 200 to 250 Amp (HSR 23.22.1.5)
Supply and erection of sheet steel enclosures 1pole/ 2 pole/4 pole including providing SP/DP/TP/FP MCB on wall/on existing pedestal complete with necessary connections etc, :- (HSR 23.22.3) SPN or DP enclosure Suitable for DPMCB (HSR 23.22.3.2)
Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.4) TPN DB Horizontal type Double Door 8 way (8 incoming and 3 phase * 8 outgoing) (HSR 23.22.4.7)
Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections (HSR 23.22.5) 6 Amp. to 32 Amp. Single Pole (HSR 23.22.5.1)
6 amp. to 32 amp Double POLE (HSR 23.22.5.3)
40 Amp. to 63 Amp. MCB's Triple Pole (HSR 23.22.5.6)
6 Amp. to 32 Amp. MCB's Four Pole (HSR 23.22.5.7)
40 Amp. to 63 Amp. MCB's Four Pole (HSR 23.22.5.8)
Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVc conduit as required (HSR 23.23.9)
Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVc conduit as required (HSR 23.23.10)
Load Bank 8 way 400 A (HSR 23.24.4.4)
Earthing and Lightening Arrestor (HSR 24.1) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. (but without charcoal or coke and salt) as required (HSR 24.1.1)
Extra for using salt and charcoal/coke for earth electrode as required. (HSR 24.1.2)
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) complete as required. (HSR 24.1.3)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. (HSR 24.1.5)
Supplying and Laying 25mm x 3mm G.I. Strip in 40mm dia GI pipe as/from earth electrode including soldering etc. as required.(HSR 24.1.7)
Providing and laying earth connections from earth electrode with 4.00 mm dia GI wire in 15 mm dia GI pipe from earth electrode as required. (HSR 24.1.11)
Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. stapples of same size.(HSR 24.1.14)
Laying of underground cable in pipe /existing open/closed tench tc as required:- (HSR 24.2.4) 185 sqmm to 240 sqmm 3 to 3½ Core (HSR 24.2.4.4)
300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.5)
Laying of underground cable in pipe /existing open/closed tench tc as required:- (HSR 24.2.4) 50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.4.3)
S/E of mark double walled corrugated (DWC) HDPE pipe10 Kg./Cm2 laid 0.75 mtr. below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work. (HSR 24.5.2) DWC/HDPE pipe 63/50 mm outer dia / inner dia. (HSR 24.5.2.3)
DWC/HDPE pipe 90/75 mm outer dia/inner dia. (HSR 24.5.2.4)
DWC/HDPE pipe 120/105 mm outer dia/ inner dia. (HSR 24.5.2.5)
DWC/HDPE pipe 145/123 mm outer dia/ inner dia. (HSR 24.5.2.6)
Non Schedule items:- Supply & erection of M.S. Box made of 16 Gauge of size d 8" x 10" x 4" covered with3 mm thick bakelite sheet white colour of ISI Mark fixed by means of 4 Nos. brass screws with cost of 1 No. 15 Amp. multi socket of ISI Mark and 15 Amp. switch and 3 Nos. 5 Amp. multi-socket with 5 Amp. switches of ISI Mark including fixing the M.S. Box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work.
Non Schedule items:- S/E of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfation of Engineer-in-Charge of the work. 70 Sqmm 3.5 Core Cable (Ard)
120 Sqmm 3.5 Core Cable (Ard)
185 Sqmm 3.5 Core Cable (Ard)
300 Sqmm 3.5 Core Cable (Ard)
Non Schedule items:- Supply and erection of PVC unsheathed (ISI Marked) copper conductor cable 1100 V grade in pipe of suitable size excluding cost and erection of pipe but,including connections etc.with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 1.5 Sqmm
Non Schedule items:- Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 250 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. 8-Way
Non Schedule items:- Supply / erection/ Testing / commissioning of 800 amp 4 pole 50 KA ACB EDO (Electrical draw out type) with microprocessor based release for over current, short circuit & earth fault in existing LT panel including labour charges complete in all respect upto the entire satisfaction of the Engineer-in Charge of the work.
Non Schedule items:- Supply and erection of Air insulated compact rising main having enclosure made up of 1.6 mm GI sheet duly powder coated, 4P aluminium bus bars in convenient section with spot of F insulator at suitable distance suitable for 415 V 50Hz AC including fire barriers, bracket and two runs of external aluminium earthing(Consider current density of 130 amp. P/Sqcm complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 200 A/10KA
Non Schedule items:- Supply and erection of End feed unit Box with provision MCCB(Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 200 Amp.
Non Schedule items:- Supply and erection of TPN Tap Boxes with 4 Pole MCCB 25 KA (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 125 Amp.
Non Schedule items:- Supply of Sandwich Rising Mains of 4 Pole (3 Ph 4 Wire system) of Aluminium busbars with integral G.I. housing as earth, Bus Trunking enclosure shall be made of 1.6mm thick Electro Galvanized GI sheet, degree of protection IP54, multi layer insulation of Class-F, Temperature rise as per IEC 61439 - 1&6. Including 2 runs of external Aluminium earthing, End cover, Vertical supports, Spring Hanger, Rigid Hanger & Two plug in point provision at every floor (Consider Current Density 130A/Sqmm) (Consider current density of 130 amp. P/Sqcm complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp.
Non Schedule items:- Supply and erection of End feed unit Box with provision MCCB for Sandwich Rising Mains (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp.
Non Schedule items:- Supply and erection of TPN Tap Boxes with 4 Pole MCCB 25 KA for Sandwich Rising Mains (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 125 Amp.
Non Schedule items:- Supply and erection of suitable MCCB designed for Compact Air Insulated rising main and sandwich rising main complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp. 4P 50 M.P. MCCB
1600 Amp. 4P 50 M.P. MCCB
M/s JSB Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .