Loading…
Loading…
Tender Value
₹12.7 Cr
EMD Value
₹7.9 L
Closing Date
5 Jan 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SNT/C/SDAH
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 1.5 V/N crores or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: GCC April 2022 13 (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender .
Similar Nature of Work "Electronic Interlocking Work {Indoor or (Indoor + Outdoor)} And /Or Panel Interlocking Work {Indoor or (Indoor+ Outdoor)} And /Or Route Relay Interlocking Work {Indoor or (Indoor+ Outdoor)}".
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electronic Interlocking work at Godda Station in Connection with LHB maintenance depot work and Godda-Pirpainti New line work in Malda Division of Eastern Railway.
SANDT-CON-SDAH-04-2025~ER
SANDT-CON-SDAH-04-2025
Open
Works - General
6 Months
Kolkata, West Bengal
₹0
₹7.9 L
5 Jan 2026
12 Dec 2025
22 Dec 2025
480 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 8,25,12,519 | ||
| Per Functional Vital Bit | 399.00 | — | — | ||
| Design, manufacture and supply of Electronic Interlocking (EI) system complete with architecture of EI at Godda Station(Distributed = Central+1 EI Hut and VDU size=65 inch) , ..... (d)Supply of Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as recommended by OEM. # - Break-up of cards are not to be submitted as per latest guidelines of Railway Board. Complete description of schedule is available at Pt. 4.3 of Special Condition of Contracts of tender Documents. For Station with routes more than 50 and less than 200 routes | — | — | — | 2,87,42,364 | |
| — | 1.00 | — | — | ||
| Installation, wiring, testing (FAT & SAT) and commissioning of EI System with 'Hot Standby' architecture as supplied above item-100101/2/3. It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional.Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time.Note: EI Annexure at pt. No. 4.3 as given in Special Conditions of Contract is to be followed during execution of this item. | — | — | — | 5,96,262 | |
| — | 1.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Alteration involving modification in up to 10 routes. | — | — | — | 17,44,012 | |
| — | 1.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Alteration involving modification from 11 up to 20 routes. | — | — | — | 26,99,619 | |
| — | 2.00 | — | — | ||
| Supply of portable work station to run along with EI configuration tools, data input, simulation and functional testing, diagnostics and trouble shooting and commissioning of EI System. It also includes supply of Laser Printer (Only branded). The minimum configuration of workstation should be Intel i5 with 8 GB RAM,500 GB HDD and 15 inches LED display of standard make such as Dell/HP/Lenovo or Equivalent with required softwares as mentioned above and compatible ports to connect with EI. Detailed Technical Specifications should be attached with the tender document by Tendering authority. Inspection: Consignee. | — | — | — | 1,65,836 | |
| — | 1.00 | — | — | ||
| Maintenance supervision of Electronics Interlocking equipment for one years from the date of expiry of free maintenance period as per conditions of contract, as per the details given in special condition of contract agreement, as per the latest guidelines of PCSTE, and provision mentioned in Signal Engineering Manual. All the records are to be maintained as per latest circulars prevailing in the Division. During maintenance at least two expert personnel from the firm should be available at the station round the clock. NOTE-This item will be operated separately and will not restrict closure of contract. Separate bank guarantee will be submitted for this schedule item if require. | — | — | — | 2,34,164 | |
| Man-Days | 60.00 | — | — | ||
| Training of Railway Personnel by OEM for installation, Commissioning, Testing, troubleshooting & making changes in application data and logics by railway officials to suit yard modification done at later stage including documentation. (Hard copies of training material/ course modules to be given to each participant). | — | — | — | 1,74,060 | |
| — | 1.00 | — | — | ||
| Supply, Installation, wiring, testing and commissioning of embedded fan less PC with VDU for control terminal/maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest .Note: (i) Technical requirements & size(65inch) of VDU shall be mentioned in the tender document. | — | — | — | 2,69,001 | |
| — | 1.00 | — | — | ||
| Supply of maintainer's furniture of Godrej make or superior and each set consist of(i) executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no.(iii) visitor chair seat & back cushion with high density foam with plastic PVC handle capsule type painted back-03 nos. | — | — | — | 23,528 | |
| — | 1.00 | — | — | ||
| Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents for alteration work. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD). Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways, then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings.It also includes preparation and supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets photo copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel, VDU Diagram,Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of design and completion documents for a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). | — | — | — | 58,797 | |
| — | 2.00 | — | — | ||
| Supply of Micro Processor based Data Logger System with 1024 digital and 32 analog inputs with DOT Matrix Printer,80 COL as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes supply of leased line MODEM and other interfacing cards, if required for networking of Data logger. This also includes supply of one no. composite computer and printer table (Godrej work station table or similar) for keeping processor module workstation and one number Godrej operator chair Model PCH7001 or similar. Note: (1) Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway. (2) Exceptional reports are to be generated by a computer connected to datalogger at the station and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. Manufacturing date of datalogger/RTU and printer should be of current year at the time of supply. Inspection: RDSO for Datalogger. Inspection: Consignee for Printer & other items. | — | — | — | 9,92,466 | |
| — | 2.00 | — | — | ||
| Supply of 24V power supply with Charger as per RDSO Spec. No. IRS-S-93/96B with Amdt.1 or latest with battery backup of 80AH capacity for data logger. Material to be procured from RDSO's approved source only. Inspection: -By RDSO. | — | — | — | 63,274 | |
| — | 2.00 | — | — | ||
| Supply of Dual Leased Modem internal card to fit in central processing unit rack for networking of data logger system of other stations. Each set shall comprise of one pair of modem and shall have data compatibility 1TUV 21, V2, V22 BITS, V23V23A, B V25 BITS, V32, V32 BITS V42, V42 BITS, suitable to work in either ofc media or microwave or quad cable. Inspection: By Consignee. | — | — | — | 48,866 | |
| — | 2.00 | — | — | ||
| Installation, wiring, testing & commissioning of Micro Processor based Data Logger System with 1024 digital and 32 analog inputs as per RDSO Spec. No. IRS (S) 99/2006 or latest. It cover complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & DG sets, ELD, IPS, UFSBI, BI interlinking and networking of Data logger. All material required for wiring, networking, power supply monitoring, door-locking arrangement etc. will be supplied by contractor. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway.Networking of data logger includes extraction of data report from Control room. Exceptional reports are to be generated by a computer connected to datalogger at the station and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC/AUTO/EI Huts and it will be extended by contractor up to location of data logger by using CAT- 5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre- Commissioning checklist (circulated by RDSO) with the OEM representative. Datalogger to be validated and commissioned before simulation test and put in network, validation statement should be jointly signed by railway engineer (open line), railway engineer (construction) & OEM'S engineer before simulation test with name, designation and date. Payment for this item will be released only after submission of duly signed pre-commissioning checklist of data logger in standard RDSO format, joint signature of validation statement. OEM'S engineer will also impart training to rly staff at site for proper functioning /working and applications of data logger.For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC/AUTO/EI Huts and it will be extended by contractor up to location of data logger by using CAT-5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre- Commissioning checklist (circulated by RDSO) with the OEM representative. Datalogger to be validated and commissioned before simulation test and put in network, validation statement should be jointly signed by railway engineer (open line), railway engineer (construction) & OEM'S engineer before simulation test with name, designation and date. Payment for this item will be released only after submission of duly signed pre-commissioning checklist of data logger in standard RDSO format, joint signature of validation statement. OEM'S engineer will also impart training to rly staff at site for proper functioning /working and applications of data logger.Inspection: Consignee. | — | — | — | 1,03,752 | |
| — | 2.00 | — | — | ||
| Supply of Failure Analysis System (FAS) with Fault Analysis Software (Datalogger Analyser) consisting of a PC (Make- Dell /HP or Equivalent) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The minimum specification should be as given core i7 or higher version processor (speed 3.2 GHZ, 4 MB cache memory),8 GB RAM,2TB HDD or Higher, Two front and four rear USB port,1 Serial & 1 Parallel Port,1VGA Port,21'' LED Colour Monitor (HP/DELL or equivalent) or Bigger Size, Sound Card with Speaker,1000 MBPS Network Card, Keyboard, Optical Mouse,10/100 T Lan Card, Combo Drive, Microsoft Windows 10 Licensed OS with Licensed (Antivirus, MS Office etc.),UPS 750 VA with 30 Minutes minimum backup (APC/ Microtek or Equivalent), LaserJet Printer(HP Pro 1108 or superior).Inspection: Consignee | — | — | — | 2,33,108 | |
| — | 2.00 | — | — | ||
| Supply of T-Networking equipments suitable for Networking to the existing Data Logger equipments. This includes supply of all equipment / accessories required for the purpose e.g. modems and network accessories. Inspection: Consignee. | — | — | — | 45,974 | |
| — | 2.00 | — | — | ||
| Commissioning of T-Networking suitable for Networking to the existing Data Logger equipments. This includes supply of all equipment / accessories required for the purpose. Inspection: Consignee. | — | — | — | 12,196 | |
| — | 1.00 | — | — | ||
| Modification/ upgradation, validation and alteration of data logger as per site engineer. This includes changes of NMDL software etc. Also data logger to be interfaced with PI/ EI equipment keeping at relay room. This work includes validation, wiring, etc. For this work necessary wire from relay to tag block & from tag block to data logger and tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms and to be inspected by consignee. | — | — | — | 49,160 | |
| — | 100.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn. No. IRS: S-34 & S-23 with Amdt. up to date or latest. The interlocking code for this unit shall be "ABCDE".Inspection authority:- RDSO | — | — | — | 3,76,900 | |
| — | 200.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn. No. IRS: S-34 & S-23 with Amdt. up to date as applicable or latest. The interlocking code for this unit shall be "ABCDF".Inspection authority:- RDSO | — | — | — | 7,47,400 | |
| — | 50.00 | — | — | ||
| Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn. No. IRS: S-34 & S-23with Amdt. up to date as applicable or latest. The interlocking code for this unit shall be "ABDEG". Inspection authority:- RDSO | — | — | — | 2,85,900 | |
| — | 90.00 | — | — | ||
| Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1 and RDSO Specn.No.IRS:S-34 & S-23 with Amdt. up to date as applicable or latest. The interlocking code for this unit shall be "ABDHK". Inspection authority:- RDSO | — | — | — | 4,42,080 | |
| — | 30.00 | — | — | ||
| Track Relay QBAT, AC immunized, 2F-2B contacts, 9 ohms. Complete with plug board, retaining clip & connectors as per RDSO/SPN/84 Ver 2.0 or latest. The interlocking code for this unit shall be "ABEJX".Inspection authority:- RDSO | — | — | — | 1,96,620 | |
| — | 250.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No. IRS - S-24, S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH". Inspection authority:- RDSO | — | — | — | 9,61,250 | |
| — | 50.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.RDSO IRS - S-24, S-23 and S-60 with amdt. up to date as applicable or latest. The interlocking code for this unit shall be "ABDFH". Inspection authority:- RDSO | — | — | — | 2,00,350 | |
| — | 20.00 | — | — | ||
| Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 939A & 966(Appendix F2) and RDSO Specn. No. IRS S-34 S-23 with amdt. up to date as applicable or latest with latest amdt. or latest. The interlocking code for this unit shall be "FGHKX". Inspection authority:- RDSO | — | — | — | 76,300 | |
| — | 50.00 | — | — | ||
| Q-Series Neutral Line Relay (QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn. No. IRS S-34 S- 23 & S 60 with amdt. up to date as applicable or latest. The interlocking code for this unit shall be "ABDEJ".Inspection authority:- RDSO | — | — | — | 2,61,500 | |
| — | 120.00 | — | — | ||
| Contactor Unit (QBCA1 Type), 24 V DC, 2F(HD)/4B or 2F(HD)2F-4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 with amdt. up to date as applicable or latest. The interlocking code for this unit shall be "BCEJK" or "DEHJX". Inspection authority:- RDSO | — | — | — | 8,21,040 | |
| — | 50.00 | — | — | ||
| Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized with different ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S-60 IRS S:46.Inspection authority:- For bare relay -RDSO, for key lock housing- consignee | — | — | — | 4,01,750 | |
| — | 140.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO | — | — | — | 6,85,160 | |
| — | 200.00 | — | — | ||
| Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be supplied & issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. This item is to be used for only Alterations in any EI/PI/RRI.Inspection: Consignee. | — | — | — | 2,600 | |
| — | 5.00 | — | — | ||
| Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago / Phoenix/Similar) , scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. Supply. Inspection: (i) RITES if value of item in work more than 5 lakhs. (ii)Consignee if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 2,24,620 | |
| — | 5.00 | — | — | ||
| Installation and execution of Cable termination rack as above. | — | — | — | 28,950 | |
| — | 400.00 | — | — | ||
| Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only. Inspection: RDSO. 1 WAY,DRG.NO.23741A, ALT-4. | — | — | — | 31,200 | |
| — | 1600.00 | — | — | ||
| Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only. Inspection: RDSO. 6 WAY, DRG.NO.23756, ALT-3. | — | — | — | 7,76,000 | |
| — | 600.00 | — | — | ||
| Supply of fuse block (PBT) to spec.no.IRS-S-75/2006(REV-2) OR LATEST,DRG.NO.SA- 23748 with fuse inserts cartridge, non-deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: -RDSO. Fuse, non- deteriorating(2A/6A/10A/16A) type, cylindrical(IRS-S-78/92) [quantity as per site requirement] | — | — | — | 36,600 | |
| — | 300.00 | — | — | ||
| Supply of fuse block (PBT) to spec.no.IRS-S-75/2006(REV-2) OR LATEST,DRG.NO.SA- 23748 with fuse inserts cartridge, non-deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: -RDSO.Fuse Base. | — | — | — | 53,400 | |
| — | 4000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. In-charge of the work. Inspection: Consignee. | — | — | — | 36,000 | |
| — | 1500.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 82,500 | |
| — | 250.00 | — | — | ||
| Supply of End plate 2.5mm/0.091 in thick as per site requirement. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 2,500 | |
| — | 100.00 | — | — | ||
| Supply of End Stopper 10mm/0.0394 in width as per site requirement. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 1,000 | |
| — | 50.00 | — | — | ||
| Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 5,450 | |
| — | 200.00 | — | — | ||
| Supply of Markers strip. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 3,200 | |
| — | 3000.00 | — | — | ||
| Supply of Disconnect Terminal Block, screw less type, 2-wire front entry (One in-put & One out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 1,68,000 | |
| — | 200.00 | — | — | ||
| Supply of shorting link (jumper) (part no - 283-402 or similar), suitable for 0.2 to 16 sq.mm terminal block 283-901 or similar. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 400 | |
| — | 200.00 | — | — | ||
| Supply of Fuse terminal block with LED indication up to 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004 (without fuse).Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 37,800 | |
| — | 200.00 | — | — | ||
| Supply of Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 9,000 | |
| — | 2.00 | — | — | ||
| Supply of Fuse auto changeover system for use in Railway Signalling System as per RDSO/SPN/209/2012 Ver.2.0 with latest amendments. One Automatic Changeover Unit comprise 32 nos. of external Non Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Inspection:(i) RDSO/RITES: if value of item in work more than 5 lakhs(ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 71,848 | |
| — | 2.00 | — | — | ||
| Supply of Fuse auto changeover system for use in Railway Signalling System as per RDSO/SPN/209/2012 Ver.2.0 with latest amendments or latest. One Automatic changeover Unit comprise 24 nos. of external Non Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signalling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. Inspection: (i) RDSO/RITES: if value of item in work more than 5 lakhs(ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 82,976 | |
| — | 4.00 | — | — | ||
| Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible.Inspection: Consignee | — | — | — | 37,924 | |
| — | 50.00 | — | — | ||
| Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]. Note: - wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. | — | — | — | 13,500 | |
| — | 2.00 | — | — | ||
| Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re-arrangement of DC-DC converters by OEM of IPS. Up to 6 Lines Station | — | — | — | 2,63,030 | |
| — | 2.00 | — | — | ||
| Ladder alteration work- Alteration Work | — | — | — | 1,39,648 | |
| — | 8.00 | — | — | ||
| Dismantling of Microlock rack, relay rack , cable termination rack of existing relay room and equipments of existing panel room & power room etc. | — | — | — | 52,968 | |
| — | 10.00 | — | — | ||
| Supply of IPS DC-DC converter 24-32V DC, 5 Amp /10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/3 Amp/5 Amp as per specification No. RDSO/SPN/165/2012, version-3.0 or latest. Make: Make: M/s. Statcon Ltd./ M/s. HBL Ltd./M/s. Amararaja Ltd. Or Other RDSO approved make, compatible for the IPS make specified by Purchaser. | — | — | — | 2,43,510 | |
| — | 110.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc.Inspection: RDSO 2V, 80 AH | — | — | — | 3,93,140 | |
| — | 60.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc.Inspection:2V, 300AH | — | — | — | 4,23,720 | |
| — | 110.00 | — | — | ||
| Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack.Inspection: Consignee.2V 80AH | — | — | — | 40,370 | |
| — | 60.00 | — | — | ||
| Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack. Inspection: Consignee.2V 300AH/ 500 AH | — | — | — | 59,220 | |
| — | 100.00 | — | — | ||
| Supply and laying of 70 sq.mm PVC insulated flexible tinned electrolytic copper down conductor placed in a metallic / PVC protective covering wherever exposed to human intervention including saddles and all accessories as required. Supply material inspection by consignee. | — | — | — | 1,36,200 | |
| — | 100.00 | — | — | ||
| Supply & laying of 25x3 mm pure electrolytic copper tape through suitable CLASS-'B' GI pipe for loop Earthing and bonding as per site requirement. Supply material inspection by consignee. | — | — | — | 1,37,700 | |
| — | 25.00 | — | — | ||
| Supply of Point JB fitted with 18 nos. 1-way terminal block confirming to IRS-S-75/91 (AMD-2) OR LATEST, DRG. NO. SA-23741A with 3 no. of 40 mm bore G I PIPE 600 mm long as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources. Inspection-Consignee. | — | — | — | 1,03,500 | |
| — | 20.00 | — | — | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E. Rly. drawing number, Sl. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below: - 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve- BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement- BS/29/727 with ALT-1. Amdt. and alt. up to date if any. Inspection: by RITES [for value of material above Rs. 5.0 lakhs. Inspection by Consignee for value of material below than Rs 5.0 lakh] Turn Out | — | — | — | 1,34,320 | |
| — | 4.00 | — | — | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E. Rly. drawing number, Sl. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below: - 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve- BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement- BS/29/727 with ALT-1. Amdt. and alt. up to date if any. Inspection: by RITES [for value of material above Rs. 5.0 lakhs. Inspection by Consignee for value of material below than Rs 5.0 lakh] Trap | — | — | — | 23,000 | |
| — | 22.00 | — | — | ||
| Supply of Electric Point machine IRS type 220 mm throw, high thrust (AC immunity 160V AC), non trailable to operate on 110V, DC complete with Lock and Detector slides, Cable Termination Box and clamp lock 60 Kg. confirming to IRS: S 24/2002 & Assy. Drg. No. RDSO-S/11000 & For Motor IRS: S 37/82. (items to be procured through stores).Inspection: RDSO. | — | — | — | 28,85,630 | |
| — | 22.00 | — | — | ||
| Installation of electric point machines on MS plate fixed on wooden/ concrete sleepers complete with fixing of junction boxes, ground connections including smithy works involved, insulation of MS plate on which the point machine is to be fixed from the gauge tie plate involving riveting/welding of angle cleats, installation of point JB, termination adjustment for operation of points by crank handle, painting and lettering as required including wiring, testing and commissioning. Note: MS plate/flat/angle /angle cleats, paints, bolts & nuts and washers of sizes as required for fixing the point machine shall be supplied by the contractor except point machine. | — | — | — | 2,28,954 | |
| — | 22.00 | — | — | ||
| Point insulation Complete set as per RDSO/SPN/168/2005 forPoint insulation Complete set as per RDSO/SPN/168/2005 for 1.Switch bracket 'D' bracket insulation for IRS point machine - One set comprises of (a)Side plate LH to Drg.No.S-3266 - 1 No. (b)Side plate RH to Drg.No.S-3265 - 1 No. (c)Insulating bush to Drg.No.S-3199 - 4 Nos. (d) Insulating washer to Drg.No.S- 8640 - 4 Nos., 2. Split-Stretcher bar 2.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T- 10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T- 10371 - 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos& 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 27,104 | |
| — | 22.00 | — | — | ||
| Gauge Tie plate insulation as per RDSO/SPN/168/2005 as per RDSO drg. No: T- 10372Alt2, T- 10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and as per RDSO/SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 8,030 | |
| — | 3.00 | — | — | ||
| Dismantling of existing point fittings, drilling of holes in stock rail/tongue rail/ gauge tie plate, re arrangement and refixing of existing electrical detector and installation of IRS 24/2002 with latest Amdt. point machine on MS plate fixed on wooden/concrete sleepers complete with fixing of point JB ground connections including smithy job for welding & termination & wiring of point machine, adjustment and testing as per technical specification and dismantling of all new fittings excluding point machine and marking with paint for future and transportation up to railway's store. | — | — | — | 24,885 | |
| — | 10.00 | — | — | ||
| Installation, wiring and testing of electrical key transmitter for crank handle arrangement, siding control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for crank handle interlocking arrangement siding control as per yard diagram, approved circuit diagram and specn.no. IRS-S-21/01(LATEST) AND IRS-S-23(LATEST),DRG.NO.SA-22601 (ADV)ALT.2. [key combination will be intimated by site engineer] Supply. Inspection : RDSO. | — | — | — | 73,450 | |
| — | 10.00 | — | — | ||
| Installation, wiring and testing of electrical key transmitter for crank handle arrangement, siding control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for crank handle interlocking arrangement siding control as per yard diagram, approved circuit diagram and specn.no. IRS-S-21/01(LATEST) AND IRS-S-23(LATEST),DRG.NO.SA-22601 (ADV)ALT.2. [key combination will be intimated by site engineer] Execution. | — | — | — | 67,960 | |
| — | 22.00 | — | — | ||
| Supply of GI bend pipe, 'B' class, 50mm dia. for cable entry in point machines, along with required fixing arrangements as per standard practice on Eastern Railway. Inspection: Consignee. | — | — | — | 57,486 | |
| — | 3.00 | — | — | ||
| Dismantling of point machine with ground connection including point JB. | — | — | — | 3,507 | |
| — | 35.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: Consignee | — | — | — | 5,985 | |
| — | 10.00 | — | — | ||
| Installation wiring, testing and commissioning of single rail dc track circuit (TRACK CIRCUIT BEYOND 200 MTRS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering (double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | — | — | — | 32,590 | |
| — | 15.00 | — | — | ||
| Installation wiring, testing and commissioning of single rail dc track circuit (SHORT LENGTH TRACK CIRCUIT UPTO 200 MTS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering (double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | — | — | — | 48,660 | |
| — | 10.00 | — | — | ||
| Installation, wiring, testing & commissioning of track circuit involving points & crossings as per track circuiting plan, track battery charging and installation including drilling 9/32" hole on rails; fixing of bonding(double) with 8 SWG soft GI wire, insulation of stretcher bars (leading & following), gauge / crossing tie plates involving cutting and riveting/welding of angle clit, split stretcher bars, fixing of track lead junction box, rail connector with GI wire, track jumpering (double) with supporting arrangement for holding termination of track lead wires, including series jumpers, jumper wire terminals, track feed set(track chargers, resistance, fuses, battery etc.) As per approved IYD for point zone track circuit. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | — | — | — | 33,480 | |
| — | 140.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) made from FRP material including brass bolts and hylum board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakelite terminal block fitted horizontally : each bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long along with two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come along with holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied along with TLJB. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 4,98,960 | |
| — | 40.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn. No.IRS: S-65/83 (Amnd. 1) or latest. Inspection: RDSO. | — | — | — | 2,06,040 | |
| — | 1000.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee. | — | — | — | 4,000 | |
| — | 400.00 | — | — | ||
| Supply of GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding. Inspection: Consignee | — | — | — | 4,800 | |
| — | 100.00 | — | — | ||
| Provision/Installation of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia. holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee. | — | — | — | 18,000 | |
| — | 50.00 | — | — | ||
| Supply, Transportation, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchaser & Track Section as per SIP uploaded with the tender, complete with all accessories, cable required with each track device & Card viz., Axle Detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to be supplied along with the system), Reset unit, Relay unit, Event logger & Diagnostic terminals etc. required for different Detection Points & Track Sections as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest as per Annexure(A, B & C.) | — | — | — | 1,71,27,900 | |
| — | 1.00 | — | — | ||
| Supply of Tools Kit for High frequency Digital Axle Counter Multi section. This includes Supply of Service test panel including meter for test of track equipment, tools for mounting and adjustment of track equipment and standard jig for drilling holes in rail. It should be as per Principal manufacturers (OEM) recommended list adequate for installation, day to day maintenance, and adjustment of indoor and outdoor gears. This shall also include kit for making and drilling of holes on rail. Note: (1) this also includes supply of cross talk measuring set as per RDSO SPEC. TC 45-88 or latest, dB meter for measuring attenuation loss & 500v insulation tester, dummy wheel, torque wrench (2) multimeter should be pure sine wave digital multimeter make Fluke Model 287/ Rishabh Model 28s. Each measuring tools & equipments to be supplied with OEM'S test certificate/ guarantee certificate (as applicable). Detail Specification of tools kit are provided in tender document. Inspection: Consignee. | — | — | — | 1,13,319 | |
| — | 1.00 | — | — | ||
| Supply of Portable operator console for onsite programming of Axle Counters as per technical requirement given in tender document. Inspection: Consignee. | — | — | — | 76,514 | |
| — | 1.00 | — | — | ||
| Supply of Block Panel BPAC (Block Proving with digital axle counter) using UFSBI as per specification IRS: S-105/2012 Ver.0 with latest amendment for Single Line operation. NOTE: One set will include equipments required for one complete Single Line Block Section except DAC. This includes Relay, Relay Base, Retaining clip & connectors to be supplied by the contractor along with the UFSBI. Inspection: RDSO. | — | — | — | 9,88,361 | |
| — | 1.00 | — | — | ||
| Supply of Automatic Media changeover system of Modem working on redundant channel for data transmission on OFC/Quad/ microwave radio, for seamless operation of UFSBI over multiple media. Inspection: Consignee. | — | — | — | 35,182 | |
| — | 1.00 | — | — | ||
| Supply of Modem for UFSBI for use with secondary media OFC/Quad. The modem shall be complete with existing system as per RDSO/SPN/147/2005 with amendment -1 or latest. Inspection: Consignee. | — | — | — | 68,461 | |
| — | 2.00 | — | — | ||
| Installation and commissioning of modem & media change over as above. Note: all required materials for execution to be supplied by the contractor. | — | — | — | 37,092 | |
| — | 1.00 | — | — | ||
| Installation, Testing & commissioning of Block proving by Axle Counter (BPAC) including UFSBI equipment as per standard practice & directive of engineer in charge and as per OEM guidelines.Inspection: Consignee. | — | — | — | 72,276 | |
| — | 2.00 | — | — | ||
| Supply of hand operated track drilling machine for bonding hole. Inspection: Consignee | — | — | — | 12,058 | |
| — | 100.00 | — | — | ||
| Supply of Drill bit 9/32" (7.14MM). IS:5099/83 AND 5101/69 OR LATEST. Inspection: Consignee | — | — | — | 5,100 | |
| — | 4.00 | — | — | ||
| Rail joint insulation thermoplastic polyurethane moulded 52 kg rail complete to SA- 22101(ALT-6) with latest alteration and to suit specification no. RDSO/SPN/168/2005 REV.2 with amdt up to date if any(without metal parts). Firm's offer: item description: IRJ TPU 52 KGS as per DRG NO SA 22101 consisting (1) channel , DRG NO S 2213 - 4 NOS. (2) end post, DRG NO S 22105 - 1 NO. (3) INS. PLATE, DEG NO S 22106 - 4 NOS. (4) INS. BUSH, DRG NO S 22109 - 8 NOS. & SPEC. NO. RDSO/SPN/168/2005. Inspection: Consignee. | — | — | — | 2,664 | |
| — | 10.00 | — | — | ||
| Rail joint insulation thermoplastic polyurethane moulded 60 kg Rail complete to drg no SA- 22171(Alt-2)(with latest alteration if any)and as per specification no RDSO/SPN/168/2005, Rev.2 , with amdt. up to date if any (Without metal parts). Firm's Offer: ITEM DESCRIPTION: (1) CHANNEL, DRG NO S 22173 - 4 NOS (2) END POST, DRG NO S 22175 - 1 NO. (3) INS. PLATE, DRG NO S 22176 - 4 NOS (4) INS BUSH, DRG NO S 22179 - 8 NOS.& SPEC. NO. RDSO/SPN/168/2005. Inspection: Consignee. | — | — | — | 7,260 | |
| — | 100.00 | — | — | ||
| Supply & installation of polymer positive temperature coefficient device (PPTC) resettable fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHEM, BOURNS,LITTLE FUSE,FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs.". Inspection: Consignee. | — | — | — | 7,900 | |
| — | 40.00 | — | — | ||
| Supply & installation of 'C' class surge protection arrangement at feed end DC Track Ckt Specn no. As follows: - voltage 230 V AC rated voltage 350V AC DIS. CAP 10KA TO 20 KA TIME 100 MILI second protection 1.2V degree protection IP.20 TEC-61643-1. Inspection : by consignee. | — | — | — | 53,840 | |
| — | 10.00 | — | — | ||
| Releasing of existing TLJB and its accessories. | — | — | — | 7,480 | |
| — | 10.00 | — | — | ||
| Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO RED Aspect | — | — | — | 83,620 | |
| — | 10.00 | — | — | ||
| Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO YELLOW Aspect | — | — | — | 83,870 | |
| — | 6.00 | — | — | ||
| Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO GREEN Aspect | — | — | — | 56,628 | |
| — | 20.00 | — | — | ||
| Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/153/2011 (Rev.4.1) or latest. Inspection: RDSO. LED for Route Aspect | — | — | — | 1,09,560 | |
| — | 40.00 | — | — | ||
| Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/153/2011 (Rev.4.1) or latest. Inspection: RDSO. LED for Shunt Signal Aspect | — | — | — | 2,27,000 | |
| — | 3.00 | — | — | ||
| Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/153/2011 (Rev.4.1) or latest. Inspection: RDSO. LED for Calling ON Signal Aspect | — | — | — | 20,490 | |
| — | 3.00 | — | — | ||
| Supply of colour light signal post 4.6 mtrs. and ladder 4.5 mtrs. with bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA-23153/ADV/AIT-1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured from approved list of firms for manufacturer & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 47,850 | |
| — | 2.00 | — | — | ||
| Supply of colour light signal post 3.6 mtr and ladder 3.5 mtr with bases for ladder & post as per RDSO SPEC. NO. IRS: S-6-81 (or latest) and DRG. NO. SA-23150 (ADV), ALT-1 (OR LATEST). CLS base as per DRG. NO. S-2011/M (OR LATEST). Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 31,454 | |
| — | 2.00 | — | — | ||
| Installation, erection and wiring of CLS unit (including post, base, ladder etc.), LED unit including paying out of tail cable from location box and Earthing of CLS [LED type]. This includes supply of CLS unit 2 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 23003/A (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note: - installation, erection & wiring of signalling unit includes led signal lightening unit including current regulator. this also includes protection of unit from rain water. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 39,126 | |
| — | 2.00 | — | — | ||
| Installation, erection and wiring of CLS unit (including post, base, ladder etc.), LED unit including paying out of tail cable from location box and Earthing of CLS [LED type]. This includes supply of CLS unit 2 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 23003/A (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note: - installation, erection & wiring of signalling unit includes led signal lightening unit including current regulator. this also includes protection of unit from rain water. Execution | — | — | — | 4,176 | |
| — | 3.00 | — | — | ||
| Installation, erection and wiring of CLS unit(including post, base, ladder etc.),LED unit including paying out of tail cable from location box and earthing of CLS [LED type]. This includes supply of CLS unit 3 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 24622 (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note :- signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 74,451 | |
| — | 3.00 | — | — | ||
| Installation, erection and wiring of CLS unit(including post, base, ladder etc.),LED unit including paying out of tail cable from location box and earthing of CLS [LED type]. This includes supply of CLS unit 3 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 24622 (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.Note :- signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Execution | — | — | — | 7,314 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of CLS unit(including post, base, ladder etc.),LED unit including paying out of tail cable from location box and Earthing of CLS [LED type]. This includes supply of CLS unit 4 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 24661 (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note :- signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 24,819 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of CLS unit(including post, base, ladder etc.),LED unit including paying out of tail cable from location box and Earthing of CLS [LED type]. This includes supply of CLS unit 4 aspect complete without lenses, lamps and signal transformer as per DRG.NO.SA 24661 (ADV) AND AS PER SPEC.NO.IRS/S-26/64. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note :- signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Execution | — | — | — | 2,733 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Supply of 1 WAY AS PER RDSO DRG. NO. SA-23401 (ADV)/ALT.2. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs.(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 19,843 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water Execution of 1 WAY AS PER RDSO DRG. NO. SA-23401 (ADV)/ ALT.2 | — | — | — | 806 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water Supply of 2 WAY AS PER RDSO DRG. NO. SA-23402 (ADV)/ ALT.2 Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs.(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 20,498 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water .Execution of 2 WAY AS PER RDSO DRG. NO. SA-23402 (ADV)/ ALT.2 | — | — | — | 1,247 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water Supply of 3 WAY AS PER RDSO DRG. NO. SA-23403 (ADV)/ ALT.2 Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 24,060 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of junction type route indicator [LED type]. This includes supply of junction type route indicator without lamp, lenses, signal transformer. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - signal unit should be compatible to 'LED' type. Note :- installation , erection & wiring of signalling unit includes led signal lightening unit including current regulator .this also includes protection of unit from rain water. Execution of 3 WAY AS PER RDSO DRG. NO. SA-23403 (ADV)/ ALT.2 | — | — | — | 1,895 | |
| — | 16.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit on the same post below the main signal as per technical specification. This includes supply of position light shunt signal unit without lenses, lamps, base, post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 88,704 | |
| — | 16.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit on the same post below the main signal as per technical specification. This includes supply of position light shunt signal unit without lenses, lamps, base, post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Only - Execution | — | — | — | 8,080 | |
| — | 10.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit as per technical specification. This includes supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 67,820 | |
| — | 14.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit as per technical specification. This includes supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Only - Execution | — | — | — | 7,028 | |
| — | 6.00 | — | — | ||
| Supply of Calling ON/ Guard Repeater Signal Unit with Brackets & Fixing accessories. Calling ON/ Guard Repeater Signal Unit shall conform to RDSO Drg no 24351(Adv) Alt1 suitable to LED Signal Lighting Unit. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 15,198 | |
| — | 6.00 | — | — | ||
| Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post including Guard Repeater Signal. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice. Inspection: Consignee. | — | — | — | 13,986 | |
| — | 1.00 | — | — | ||
| Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area. Inspection: Consignee. | — | — | — | 3,502 | |
| — | 6.00 | — | — | ||
| Casting, concreting and curing of foundation (1:3:6) and erection of SLB/BSLB/SB/WB/Stop board as per DRG. NO S&T/C/34 ( NKG ) all materials required for the work including cement, rail post etc. To be supplied by the contractor. This includes supply of SLB/BSLB/SB/WB/ Stop board as per RDSO DRG NO. SA-2375 (ADV.) ( WITH LATEST AMDT.) for SLB/BSLB and as per RDSO DRG NO. 7235/B ( WITH LATEST AMDT.) for SB/WB/Stop Board. Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 7,350 | |
| — | 6.00 | — | — | ||
| Casting, concreting and curing of foundation (1:3:6) and erection of SLB/BSLB/SB/WB/Stop board as per DRG. NO S&T/C/34 ( NKG ) all materials required for the work including cement, rail post etc. To be supplied by the contractor. This includes supply of SLB/BSLB/SB/WB/ Stop board as per RDSO DRG NO. SA-2375 (ADV.) ( WITH LATEST AMDT.) for SLB/BSLB and as per RDSO DRG NO. 7235/B ( WITH LATEST AMDT.) for SB/WB/Stop Board. Only- Execution | — | — | — | 34,320 | |
| — | 2.00 | — | — | ||
| Supply and installation of P/ C / G/ A/ AG marker (size 250mm dia circle) high intensity prismatic(TYPE-IV) retro reflective sheet over 2 mm thick aluminium sheet & letter will be screen printing (250 mm dia circle) as per drg. S&T/SDAH/SK-1383 and technical specification attached. This will include cost of all materials including fixing clamp required for this work. Inspection: - inspection by rites [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | — | — | — | 1,100 | |
| — | 22.00 | — | — | ||
| Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH/SK-1386 and as per standard practice. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 8,206 | |
| — | 2.00 | — | — | ||
| Supply of offset bracket for position light shunt signal (90mm outside Dia.) post with U clamps, nuts, washers complete as per RDSO DRG. NO.SA-23080/ADV/ALT-1 all drawings should be as per latest. Inspection: by consignee. | — | — | — | 4,082 | |
| — | 2.00 | — | — | ||
| Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete DRG. NO. SA-23080/ADV/ALT-1. RDSO SPEC. NO. IRS-S-10/78. Inspection: consignee. Note : Offset bracket has to be connected wherever necessary as per site engineer. | — | — | — | 5,026 | |
| — | 3.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). | — | — | — | 24,195 | |
| — | 16.00 | — | — | ||
| Casting, concreting and curing of foundation for Shunt signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanised bolts & nuts with washers, cement, sand, stone chips, etc. As per DRG. NO SK/5/95/NKG. | — | — | — | 65,392 | |
| — | 1.00 | — | — | ||
| Releasing of existing tail cables and drawl of new tail cables for colour light signals up to four aspects with or without route indicator, post type shunt signal and calling signals. Termination of new tail cables and wiring using wire PVC 3/0.75 mm copper as per latest RDSO spec. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals [Wire PVC 3/0.75 mm copper, paints and all other miscellaneous materials shall be supplied by the contractor. Wire to be procured from RDSO's approved source only]. Inspection- consignee. | — | — | — | 3,065 | |
| — | 3.00 | — | — | ||
| Dismantling of existing main signal including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part. | — | — | — | 3,654 | |
| — | 3.00 | — | — | ||
| Dismantling of existing Signal Foundation (up to ground level by hydraulic breaker). | — | — | — | 6,636 | |
| — | 1.00 | — | — | ||
| Supply of AC LED alpha or numeric route indicator for 1-19/A-R routes with complete housing with white LED as per specification IRS: S 66/84 Amdt.1 or latest and Drg. No. SA 23761(Adv.) or Latest. Lamp proving compatible with normal bulb type multi lamp route indicators. Input operating voltage 110V AC+/- 25%. Uniform intensity over entire operating range. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | — | — | — | 53,756 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of AC LED alpha or numeric route indicator with complete housing including necessary wiring connection with the main signal and dismantling of existing route indicator. Necessary signalling cable if required will be supplied by Railway. | — | — | — | 27,610 | |
| — | 14.00 | — | — | ||
| Installation & commissioning of sliding boom gate. This includes levelling, fixing of sliding boom with fixing of E-type lock, etc. Note : all materials to be supplied by the contractor except sliding boom gate and E-type lock. | — | — | — | 98,448 | |
| — | 10.00 | — | — | ||
| Installation of magneto / control telephone, annunciator with all accessories and dry cells (2 nos.). For each phone with wooden battery box. This includes supply of magneto telephones with all accessories including supply of 2 nos. Dry cell for each telephone with wooden battery box. (i) SPEC.FOR magneto telephone - IRS-TC-79/2000.AMD-1 OR LATEST.Execution. | — | — | — | 1,950 | |
| — | 10.00 | — | — | ||
| Supply of magneto telephone, desk type, spec. No IRS-TC-79/2000 AMDT. 1 or latest. Inspection: by consignee | — | — | — | 35,090 | |
| — | 2.00 | — | — | ||
| Supply and installation of housing cabinet of suitable dimensions to house VDU control terminal along with CPU, one set of input device (keyboard and mouse etc.), monitor and power supply arrangement. The detailed drawing of the cabinet along with placement of various equipments inside the cabinet shall be submitted by the tenderer and got approved by the Railway before supply. Technical requirement are attached herewith. Inspection: Consignee | — | — | — | 2,15,948 | |
| — | 6.00 | — | — | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | — | — | 17,412 | |
| — | 2.00 | — | — | ||
| Supply of Office Revolving Chair Godrej Make Model No.9U02R Bravo or Similar of reputed brand. Inspection: Consignee | — | — | — | 18,064 | |
| — | 2.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | — | — | 25,772 | |
| — | 2.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee | — | — | — | 34,326 | |
| — | 1.00 | — | — | ||
| Supply of Panel cum Block Instrument table complete as per approved drawing. It includes any modification to it if required by Engineer-in-charge at site. Inspection: Consignee | — | — | — | 35,573 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient No. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient No. of programmable relay control for controlling AHU's, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 1,24,758 | |
| — | 15.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Probe type bimetallic Heat Sensor/Fixed cum ROR 90 degree with required module to be communicated with main fire Alarm Panel as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 1,04,190 | |
| — | 15.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy.should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 46,830 | |
| — | 8.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Analogue Addressable Manual Call Point with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 30,000 | |
| — | 150.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 1,24,500 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver. 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 88,520 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Air Sampling Type detector shall use LASER type. This type of detector shall use piping or tubing distribution network that shall run from the detector to the area as to be protected. It should be supplied with required module & Power supply unit complete as a system with all accessories like pipes, Sampling points etc. as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 3,78,034 | |
| — | 6.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 49,650 | |
| — | 400.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of FRLS unarmoured / armoured cable(2Cx1.5 sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 45,200 | |
| — | 16.00 | — | — | ||
| Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30)° to (50)° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy. (ii) Consignee if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 82,816 | |
| — | 1.00 | — | — | ||
| Releasing of existing block instrument and allied gadgets. | — | — | — | 782 | |
| — | 50.00 | — | — | ||
| Supply of full size apparatus case (Large) (as per DRAWING NO. RDSO/S-11500 OR GKP Type).This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500.Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy. (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 6,95,800 | |
| — | 50.00 | — | — | ||
| Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti-corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside.Inspection: Consignee | — | — | — | 1,76,600 | |
| — | 50.00 | — | — | ||
| Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee | — | — | — | 2,41,500 | |
| — | 10.00 | — | — | ||
| Supply of half size apparatus case (As per as per RDSO drawing No. RDSO/S-11507 OR GKP Type). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11507.Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy. (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy. | — | — | — | 78,600 | |
| — | 10.00 | — | — | ||
| Casting, concreting and curing of concrete foundation (in ratio 1:3:6), erection and installation of half size apparatus case (GKP type) Apparatus Case as per DRG.NO. RE/S&T/SIG/TENDER /SK/8/85 with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti-corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. Inspection: Consignee. | — | — | — | 31,050 | |
| — | 10.00 | — | — | ||
| Fixing, wiring of terminal strips, hylam strip, relays, fuses with base and supply and fixing of shelves for half apparatus case with termination earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO's approved firm and to be inspected by RDSO. [quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee. | — | — | — | 35,360 | |
| — | 30.00 | — | — | ||
| Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (note-balance quantity may be taken from Rly store if available).950 x 400 x 25 MM for full size location box . | — | — | — | 16,890 | |
| — | 10.00 | — | — | ||
| Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (note-balance quantity may be taken from Rly store if available).450 x 400 x 25 MM for half size location box . | — | — | — | 4,500 | |
| — | 25.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 1,34,250 | |
| — | 10.00 | — | — | ||
| Alteration/modification in the existing location boxes (Full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 27,820 | |
| — | 5.00 | — | — | ||
| Alteration/modification in the existing location boxes (Half size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 8,035 | |
| — | 10.00 | — | — | ||
| Dismantling of location box / RCC Goomty including all its accessories & concrete foundation. | — | — | — | 6,510 | |
| — | 10.00 | — | — | ||
| Shifting/lifting of location box to facilitate earthwork of Engg/Con. This includes filling with sand and plastering inside location box. | — | — | — | 27,590 | |
| — | 100.00 | — | — | ||
| Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside). | — | — | — | 26,000 | |
| — | 10.00 | — | — | ||
| Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Half Size. (Outside & inside) | — | — | — | 2,360 | |
| — | 100.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. | — | — | — | 76,200 | |
| — | 150.00 | — | — | ||
| Laying & Fixing of Medium class GI pipes 50/100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 14,700 | |
| — | 50.00 | — | — | ||
| Supply of Medium class GI pipes 50 mm dia (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends. | — | — | — | 20,200 | |
| — | 300.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non- flame propagating type in 6 meters straight length and of size 120 mm outer dia & 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O- Ring 2)Spacers,3)Tees,4)Bend,5)End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr. length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. | — | — | — | 2,04,000 | |
| — | 10.00 | — | — | ||
| Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Colour coding as per Eastern Railway policy to be followed. | — | — | — | 6,28,670 | |
| — | 10.00 | — | — | ||
| Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of mono-mode armoured OFC cable (24/48 fibres) through duct in trenches and as advised by site engineer. Note:- (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fibre from end to end . (2) before & after laying of optical fibre cable through duct, continuity test from end to end of each fibre to be made by the contractor to ensure availability of all 24/48 fibre duly certified by the site engineer. | — | — | — | 2,47,340 | |
| — | 6.00 | — | — | ||
| Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment or Latest in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources.. For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. | — | — | — | 5,17,452 | |
| — | 8.00 | — | — | ||
| Laying of HDPE duct in trench and its protective work as per direction of site engineer. | — | — | — | 49,136 | |
| — | 200.00 | — | — | ||
| Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Specn.No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II.(The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O- Ring 2) Spacers3) Tees4) Bend,5) End-cap DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. | — | — | — | 79,400 | |
| — | 200.00 | — | — | ||
| Placing of DWC HDPE/RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | — | — | — | 6,200 | |
| — | 10.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amdt. | — | — | — | 21,850 | |
| — | 10.00 | — | — | ||
| Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. | — | — | — | 9,560 | |
| — | 100.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of sites and boring for placing of 110 mm dia HDPE PIPE for crossing of S&T cables together a bridges/culvers, pucca road/crossing, boring trench shall be minimum 3 (three) meter below the river bed and 1(one) meter below the track/road/pucca road crossing area. This includes supply of accessories for HDPE pipes, including, cost of fuel and all other items etc. which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer. HDPE PIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Boring up to the length of 150 meters. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. | — | — | — | 1,80,400 | |
| — | 100.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of sites and boring for placing of 110 mm dia HDPE PIPE for crossing of S&T cables together a bridges/culvers, pucca road/crossing, boring trench shall be minimum 3 (three) meter below the river bed and 1(one) meter below the track/road/pucca road crossing area. This includes supply of accessories for HDPE pipes, including, cost of fuel and all other items etc. which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer. HDPE PIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Boring above the length of 150 meters. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. | — | — | — | 2,37,900 | |
| — | 500.00 | — | — | ||
| Laying of 6 quad/Signalling cable/Power Cable with nylon rope through 110 mm HDPE pipe and back filling of boring pit. | — | — | — | 4,000 | |
| — | 2000.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note:- cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. | — | — | — | 35,16,000 | |
| — | 100.00 | — | — | ||
| Mechanized drilling/micro tunnelling under important/busy metal / concrete road/railway track with supply & laying of G I pipe and pulling of cable through GI pipe . This includes re instatement of the surface to the original state. As per Site requirement. G.I. Pipe as per latest IS Spec. | — | — | — | 1,75,800 | |
| — | 200.00 | — | — | ||
| Repair of pucca roads to original state in level crossing area after cable laying. | — | — | — | 51,200 | |
| — | 200.00 | — | — | ||
| Supply, Transportation at site and Installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable marker is to be fabricated as per RDSO drawing No. RDSO/Cable Laying/020, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest as per Eastern Railway policy and Tect Circular. The fixing work is to be done as per extant practice of E. Rly. and as per Railway site supervisor. | — | — | — | 83,400 | |
| — | 1800.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4" of 1:2:4 concreting should be done.Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site.(b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | — | — | — | 4,41,000 | |
| — | 200.00 | — | — | ||
| Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. | — | — | — | 55,600 | |
| — | 200.00 | — | — | ||
| Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.1.2 mtr is not possible and it will be decided by site engineer/unit officer in-charge of work. | — | — | — | 99,400 | |
| — | 10.00 | — | — | ||
| Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | — | — | — | 66,740 | |
| — | 70000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 3,50,000 | |
| — | 50.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | — | — | — | 1,79,800 | |
| — | 100.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks, sand and cement to be supplied by the contractor. | — | — | — | 1,99,100 | |
| — | 5.00 | — | — | ||
| Supply of optic fibre splice closure (24/48 fibre) as per tec. Specification no. G/OJC- 02/01, March'99 with latest amendment or latest including all miscellaneous items and consumables for fibre splicing. Inspection:- by consignee. | — | — | — | 17,790 | |
| — | 10.00 | — | — | ||
| Jointing, terminating & splicing of 24/48 fibre optic fibre cable and fixing of termination box/FDF/placing of joint closures in the pit required at various locations including transportation of all the jointing & terminating materials from railway store to the work site and returning leftover materials to the railway store. | — | — | — | 1,06,250 | |
| — | 2.00 | — | — | ||
| Supply Wiring, installation, testing and commissioning of Earth Leakage Detector (12 nos. channel) as per RDSO specification no. RDSO/SPN/256/2002 or latest having 6-digit counter, 12 Channel bus bar voltage of 110V AC/DC and/or 60V/24V/12V DC measurement in 19" sub rack along with insulation resistance meter, remote indication & buzzer in ASM room at station. The tenderer should submit three years' warranty certificate along with supply of material. This includes supply of fuse terminal strip for incoming power supply wires. On job training at site will be given by OEM engineer for installation and maintenance of ELD. Inspection by RDSO. | — | — | — | 3,35,658 | |
| — | 10.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO. | — | — | — | 1,51,470 | |
| — | 10.00 | — | — | ||
| "Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness.Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee. | — | — | — | 65,790 | |
| — | 100.00 | — | — | ||
| Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I)- 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT(galvanized) of size 35 mm x 6 mm (SPEC.NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per DR. NO SI/TYP/097 or latest Eastern Railway Policy . Inspection: - BY RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | — | — | — | 1,49,600 | |
| — | 100.00 | — | — | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest). Inspection: - BY RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | — | — | — | 91,100 | |
| — | 100.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. | — | — | — | 1,16,100 | |
| — | 100.00 | — | — | ||
| Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. | — | — | — | 57,100 | |
| — | 1.00 | — | — | ||
| Supply of Digital Multimeter of Fluke 287 Industrial or Similar/ superior True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second .Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 44,064 | |
| — | 1.00 | — | — | ||
| Supply of Professional AC/DC clamp meter 3 ¾ digit , true RMS measurement, For Measurement of DC/AC currents up to 1000A, Voltage up to 600V, resistance up to 40 M and frequency up to 1 MHz with set of leads & carrying case. Model - DCM 39A or equivalent/ higher make Motwane / Stanlay /Fluke/Megger .Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 28,752 | |
| — | 2.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 4.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .