| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹3.7 L+₹8,128 (2.23%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹3.8 L+₹12,996 (3.56%)Rejected-AOC NAI BASTI GALI NO 3 STATION ROAD POLICE CHOWKI PARICHHA JHANSI UTTAR PRADESH 284305 | JHANSI | UTTAR PRADESH | 284305 | L3 | Rejected-AOC L3 BIDDER |
Tender Value
₹3.3 L
EMD Value
₹6,500
Closing Date
5 May 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE OMC-III CTPS Parichha Jhansi
Office of SE OMC-III CTPS Parichha, Jhansi
Overhauling of station C and I System and instruments of SWAS, BTG and FO area in Unit 6 of 2x250 MW,CTPS, Parichha, Jhansi
2025_RVUNL_1025841_1
W-PAR/C/OMC3/CIMD1/6000007989
Open Tender
Power/Energy Projects/Products
Lump-sum
45 days
2x250MW, CTPS Parichha
Refer to tender documents
3 documents required · 3 mandatory
₹590
Refer to Tender Documents
₹6,500
10 Sept 2025
9 Apr 2025
8 May 2025
9 Apr 2025
5 May 2025
9 Apr 2025
9 Apr 2025 - 5 May 2025
Amount
Over Hauling of Electrical Actuator
Safely removal of electrical actuators from vales / damper, dismantling, complete overhauling / servicing, re-assembling and re-installation of the different make and various models of electrical actuators including limit switches and motor of various services, of the actuators installed in BTG,AHP&CW pump area.(Details scope of work given in annexure-1,Sl, no.1 to 11)
Overhauling & servicing C&I field instrument of BTG & FO Area.
Dismantling, cleaning, servicing, checking, testing, recalibration and re-commissioning of pressure transmitters, vacuum transmitter & flow transmitter and ensure working satisfactory.Change the transmitters (if defective)
Dismantling, cleaning, testing, recalibration and re-commissioning of pressure switch, DP switch and ensure working satisfactory. Change the switch (if defective)
Dismantling, cleaning, testing, recalibration and re-commissioning of pressure Gauges, temperature gauges, DP gauges and ensure working satisfactory.Change the pressure Gauges, temperature gauges, DP gauges (if defective)
Dismantling, cleaning, testing, recalibration and re-commissioning of Level transmitter ensure working satisfactory. Change the Level transmitter (if defective)
Disconnection from site, cleaning, testing checking, repairing & re-commissioning of thermocouple / RTD s along with their compensating cables ensure working satisfactory. Change the thermocouple / RTD s along with their compensating cables (if defective).
Overhauling miscellaneous work
Replacement / Repairing of defective root / isolating valve of transmitter, gauges, presser switch, temp switch.
Cleaning, purging, repairing, and replacement of broken impulse lines
Overhauling of VMS system
(i) Checking, cleaning & calibration of vibration probes, cables and their related panels with cards etc. change the probe/cable/cards if found defective
Overhauling of SWAS system, Gas Analyzer, & Chemical dosing system
Steam & Water analysis (SWAS) system:- 1. Disconnecting, Cleaning, Checking, Repairing, Replacement of damaged spare parts, recalibration & re-commissioning of SWAS system. 2. The firm has to call the service engineer from OEM Forbes Marshall/Yokogawa during commissioning of the system. Details of equipment as below:-
Sample cooler
Rota meter
Regulating valve/Pr. Relief valve
Solenoid valve
Flow Switch
Temperature/ pressure gauges and switches
½ “ Sample & Cooling isolating valve
2NB isolating valve
Coolant Flow Indicator
Sample Filter
3- way ball valve
S.S. Tubing, connectors, fittings & wirings etc. of Primary, Secondary rack & wet penal .
Cat ion Exchange column (Dual type)
Conductivity cell, pH electrode & DO2 Sensor
Ph/ Conductivity flow through chamber
Ph, Conductivity, DO2, Silica, Hydrazine and Phosphate Analyzer/ Transmitter
Gas Analyzer:- 1. Disconnecting, cleaning, checking, repairing, replacement, of damaged spare parts, recalibration & re commissioning.2. The firm has to call the service engineer from OEM Forbes Marshall/Yokogawa during commissioning of the system. Details of equipment as below:-
Oxygen Analyzer
Convert unit
Detector unit
Calibration unit
Sox/Nox Analyzer
Probe assembly
Power supply unit
Micro processor controller
Co Analyzer
Transmitter/receiver unit
Power supply unit
Micro processor controller
Dust Monitor
Transmitter/receiver unit
Power supply unit
Micro processor controller
Blower unit
Monitor unit
Hydrogen purity analyzer
Transmitter/receiver unit
Calibration unit
Hydrazine, Phosphate, & Ammonia Dosing system: Disconnecting, cleaning, repairing, replacement, of damaged spare parts, recalibration & re commissioning of following:
Control panel equipment & Electronics stroke control card
Temp/Pressure Gauges
Level switches
Level gauge
M/S A.K.CONSTRUCTION (BID ID -5166872)
M/S INSTRUMENT CARE GROUP (BID ID -5167127)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .