Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹26.5 L+₹2.3 L (9.39%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹27.9 L+₹3.7 L (15.2%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L3 | Rejected-Finance Rejected being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in cate b(ii) | |
| 5 | Rejected-Technical 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | - | Rejected-Technical Not enlisted in cate b(ii) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Oct 2023, 6:00 pmClosed
GE (AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/ MAINTENANCE OF HT DISTRIBUTION SYSTEM, TRANSFORMER AND ASSOCIATED SERVICES AT AF STATION UNDER GE (AF) CHABUA
2023_MES_620967_1
520/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹50,000
Yes
18 Nov 2023
29 Sept 2023
23 Oct 2023
29 Sept 2023
20 Oct 2023
13 Oct 2023
29 Sept 2023 - 6 Oct 2023
Amount
Disconnecting HT supply and taking out trolley of 11 KV VCB of any make and type and servicing of VCB, cleaning isolating contacts, moving parts, removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components and replacement of all unserviceable spares as required and all as directed, inserting in trolley, testing commissioning and putting on the supply on load complete all as directed. Note:- (i) Spares as required for replacement will be of the same company as per existing make or as recommended by the OEM (ii) Cost of spares will be measured and paid separately under relevant items. (iii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape etc
Supply only mechanical Castle interlock assembly with Key suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge.
Supply only Closing coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model and directed by Engr-in-Charge.
Supply only tripping coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model and directed by Engr-in-Charge.
Supply only fixed contact block suitable for 11 KV VCB for rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge.
Supply only 11 KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model and directed by Engr-in-Charge.
Supply only moving contact block suitable for 11 KV VCB as per existing make and model and directed by Engr-in-Charge.
Supply only vacuum interrupter type (4 inch dia) suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge
Supply only tripping push button suitable for 11KV VCB of rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge.
Supply only limit switch suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge.
Supply only charging motor suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model and directed by Engr-in-Charge.
Supply only 11KV,110 V digital volt meter (1 Phase) suitable for 11 KV VCB of rating 400/630/800 amps complete all as specified and directed.
Supply only digital amp meter (1 Phase) suitable for 11 VCB of rating 400/630/800 amps complete all as specified and directed.
Supply only Relay suitable for 11 KV VCB of rating 400/630/800 amps complete all as specified and directed.
Supply only Relay suitable for 33 KV control panel complete all as specified and directed.
Supply only single unit resin cast type current Transformer of rating 11 KV, ratio 50-25/5-5A, burden 5P10 for protection an 10VA for metering complete all as specified and directed.
Supply only single unit resin cast type potential Transformer of rating 11 KV, ratio 11KV/ √3/110V/√3 burden 100VA, pistol type complete all as specified and directed.
M&L for spray painting of transformer preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor/outdoor type capacity 63 KVA to 160 KVA to match with existing colour complete all as specified and directed.
All as per ser item No 18 above here-in-before but capacity of 200 KVA to 315 KVA complete all as specified and directed.
All as per ser item No 18 above here-in-before but capacity of 500 KVA to 630 KVA complete all as specified and directed.
M&L for painting on old painted surface of HT panels by brushing/cleaning stains & grease spots with thinner and sand paper and painting the cleaned surface with synthetic enamel paint (Light grey) Shade No 631 or as approved by the Engr-in-charge to achieve good finish by applying two coats of paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc with white paint on newly painted surfaces details as given by Engr-in-charge.
Supply, laying in trenches/through pipes under road, floor/on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 3.0 Core 95 Sqmm including taking down old unserviceable cable complete all as specified and directed.
Attending of 33/11 KV HT breakdown and finding the fault in transformers, VCBs, HT UG cables, CTs, PTs, lighting arrestor, insulator etc by highly skilled mechanic to replace any spares related breakdown complete all as specified and directed at site. (a) Spars will be paid separately under relative items.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for rewinding of HT/LV coils of transformer by using proper size super enamelled copper wire suitable for working voltage 11 KV/0.433 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed. Note:- (i) Oil filtration, supply of new oil will be measured separately. (ii) All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. (iii) The rate for taking out, refixing after repair, both side transportation, lifting/unloading of voltage stabilizer/ isolation transformer by crane/manual should be deemed to include in the rate quoted.
M&L for rewinding of existing 11/0.433 KV, HV/LV coils of tranaformer, removing unserviceable material, reinsulation with new insulated materials three layer complete and re-winding as per existing size of core of transformer including varnishing etc complete all as specified and directed.
Dehydration of HV/EHV grade transformer oil (On line/off line) to achieve dielectric strength upto 60KV for EHV grade and upto 40 KV for HV grade, complete all as specified and directed. Note:- Centrifuging Machine with all T&P & testing equipment required for dehydration to be arranged by the contractor.
Supply and filling, transformer oil EHV grade as per IS-335 of 1993 Part-II for top up/replacement as per direction by Engr-in-Charge.
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fixing in repair steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-55 (11 meter long) complete all as specified and directed. Note:- Earthwork and PCC shall be measured and paid separately under respective items.
Excavating in trenches nexc 1.5m wide and nexc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches in soft/loose soil nexc 1.5m wide and exc 1.50 m but nexc 3.0m in depth for foundation or shafts, wells cesspit, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers nexc 25cm complete all as specified and directed.
Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, levelling, well ramming completed all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers complete all as directed.
Supply and stringing in repair ACSR conductor of any size for HT/LT over head line including fixing to insulators with proper size of binding wire complete all as specified and directed
All as per item 39 but GI wire of 4 mm dia complete all as specified and directed.
M&L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer, complete all as directed.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings to poles & the like etc including weathering, slightly rounded or chamfered angles and throating as complete all as specified and directed.
Supply and fix in repair 33 KV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
Supply and fix in repair 11 kV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
M&L in repair triple pole mechanical operated, mounted on insulator with operating mechanism worked from ground level for current rating 400 amps suitable for 33000 volts complete all as specified and directed.
M&L in repair triple pole mechanical operated, mounted on insulator with operating mechanism worked from ground level for current rating 400 amps suitable for 11000 volts complete all as specified and directed.
M&L in repairs drop out fuse single pole suitable for 33000 volts grade complete all as specified and directed.
M&L in repairs drop out fuse single pole suitable for 11000 volts grade upto 50 amps complete all as specified and directed.
M&L for replacement of pin type insulator porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for working pressure 33000 volts grade complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green single disc assy for tension with tension clamps for conductors, working pressure 33000 volts complete all as specified and directed.
M&L for replacement of pin type insulator porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for working pressure 11000 volts grade complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green single disc assy for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply and fix in replacement tap changer assembly of 11/0.433 KV transformer 500 to 750 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
Supply and fix in replacement tap changer assembly of 11/0.433 KV transformer 200 to 315 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
Supply and fix in replacement tap changer assembly of 11/0.433 KV transformer 63 to 160 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
S&F in repairs bushing with brass stud, packing, nut, washers etc on primary side suitable for 7.5 MVA power transformer, primary side complete all as specified and directed.
S&F in repairs bushing with brass stud, packing, nut, washers etc on secondary side suitable for 7.5 MVA power transformer, secondary side complete all as specified and directed.
S&F in repairs bushing with brass stud, packing, nut, bolt, washers etc on HT side suitable for 500 KVA to 630 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & F in repairs bushing with brass stud, packing, nut, bolt, washers etc on HT side suitable for 200 KVA to 315 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & F in repairs bushing with brass stud, packing, nut, bolt, washers etc on HT side suitable for 63 KVA to 160 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & F in repairs bushing with brass stud, packing, nut, bolt, washers etc on LT side suitable for 500 KVA to 630 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & F in repairs bushing with brass stud, packing, nut, bolt, washers etc on LT side suitable for 200 KVA to 315 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & F in repairs bushing with brass stud, packing, nut, bolt, washers etc on LT side suitable for 63 KVA to 160 KVA 11000/433V, distribution transformer complete all as specified and directed.
S & f in repair Transformer top cover gasket/cock sheet suitable for 500 KVA to 630 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 200 KVA to 315 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 63 KVA to 160 KVA transformer complete all as specified and directed at site.
Supply and fixing in replacement of heavy duty breather assembly of capacity 0.5 kg with silica gel crystal for transformer of any capacity complete all as specified.
Supply and filling silica gel crystal in to breather assembly for transformer of any capacity complete all as specified and directed at site.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore pipe.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 50 mm bore pipe.
Supply and fixing, in replacement of MCB, DP, 240 Volts, 5 to 40 Amps, 10 KA, AC/DC complete all as specified and directed.
Supply and fixing, in repair of 33 KV current transformer out door type of ratio 200-100/5 complete all as specified and directed.
Supply and fixing, in replacement of 33 KV potential transformer out door type of ratio 200-100/5 complete all as specified and directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unsv earthing complete all as specified and as directed. NOTES:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for earthing complete with copper earth plate electrode 60 x 60 cm x 3.15 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including copper earth strip of size 20 x 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unsv one complete all as specified and as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Disconnecting of defective transformer up to 630 KVA and lifting of transformer on vehicle and transportation to workshop/factory, after repair again lifting of transformer on vehicle and transportation from workshop/factory to AF Stn Chabua and reinstalled at site and testing, commissioning upto entire satisfaction of Engineer-in-Charge. Note:- Spare parts/rewinding will be measured and paid separately.
Supply and fix in repair of LED indication lamp for VCB control panel complete all as specified and directed at site.
STANDARD ELECTRIC WINDERS
M/s HALDER ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .