Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.9 CrAccepted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹22.9 Cr | L-1 | Accepted-Finance L-1 |
| 2 | L-2₹22.9 CrRejected-Finance ECIL ELECTRONICS CORPORATION OF INDIA LIMITED ECIL HYDERABAD TELANGANA 500062 | MEDCHAL MALKAJGIRI | TELANGANA | 500062 | ₹22.9 Cr | L-2 | Rejected-Finance L-2 |
Tender Value
Refer Docs
EMD Value
₹12.8 L
Closing Date
6 Jul 2020, 2:30 pmClosed
DGM(PJ-Contracts)
Indian Oil Corporation Limited (Pipelines Division) A-1, Udyog Marg, Sector-1, NOIDA (UP) 201 301, INDIA
Design, Supply, installation, testing, commissioning of SCADA, RTUs and Leak Detection System (LDS) along with integration of SCADA System with PLC based control system at various stations of PHBPL, PSHPL, 18in HBPL and Comprehensive AMC for 5 years
2020_PLHO_116030_1
PLCC/30in HBPL-PSHPL-18in HBPL/TI/20023
Open Tender
Instrumentation - All
365 days
Odisha, WB, Bihar, Jharkhand
Please refer Tender documents.
7 documents required · 7 mandatory
₹12.8 L
Yes
Noida
1 Oct 2020
28 Apr 2020
7 Jul 2020
28 Apr 2020
6 Jul 2020
18 May 2020
6 May 2020
Amount
SCADA_SYSTEM_SUPPLY_PHB_OD
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for SCC Locations
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Server Cabinet as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, Patch Chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet. Server cabinet is to be used for housing of the new machines.
Fully integrated infrastructure racks with dedicated cooling (with Cooling redundancy), management, fire suppression, cable management, dehumidifier and power distribution with atleast 65U usable space as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, patch chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet.
Software including one time license fee for the following
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
SCADA_SYSTEM_SERVICES_PHB_OD
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At SCCs
Conversion of Machine running for Control and F&G system from Physical to Virtual using Virtualization tool. (This excludes charges of moving of software licenses of the machine being moved, License related issues of the machine being moved shall be taken care by owner )
SCADA_SYSTEM_COMPOSITE_PHB_OD
INSTALLATION OF RTU PANEL as per Scope of work.
Steel structural works as per Scope of work.
DISMANTLING WORKS as per Scope of work.
SCADA_SYSTEM_SUPPLY_PHB_WB
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for SCC Locations
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Fully integrated infrastructure racks with dedicated cooling (with Cooling redundancy), management, fire suppression, cable management, dehumidifier and power distribution with atleast 65U usable space as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, patch chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet.
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
Instruments Supply
IR Based explosion proof & weather proof (Point type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.
Multisensor Detectors with relay output along with all mounting andother accessories for installation at BV-RTU locations as per the tender specifications.
Pressure Transmitters Remote Seal Type with cable glands Range max (0 to160 kg/cm2); Smart type; accuracy 0.075% or better Installation: Underground to process pipe. Transmitter: 2" pipe Mounted.
Temperature Transmitter with surface mounted duplex RTD, Weld pad and dual sensors & Cable glands, Range max (0 to 100 0C); Smart type; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted ; RTD in weldpad welded to process pipe surface for below ground installation.
SCADA_SYSTEM_SERVICES_PHB_WB
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At SCCs
Conversion of Machine running for Control and F&G system from Physical to Virtual using Virtualization tool. (This excludes charges of moving of software licenses of the machine being moved, License related issues of the machine being moved shall be taken care by owner )
SCADA_SYSTEM_COMPOSITE_PHB_WB
INSTALLATION OF RTU PANEL as per Scope of work.
Steel structural works as per Scope of work.
DISMANTLING WORKS as per Scope of work.
Installation, testing & commissioning of various types of detectors including supply and Laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building for integration of detectors with RTUs including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of detectors, material etc
Multi Sensor Detectors & isolators
SCADA_SYSTEM_SUPPLY_PHB_JH
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Instruments Supply
IR Based explosion proof & weather proof (Point type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.
Pressure Transmitters Remote Seal Type with cable glands Range max (0 to160 kg/cm2); Smart type; accuracy 0.075% or better Installation: Underground to process pipe. Transmitter: 2" pipe Mounted.
Temperature Transmitter with surface mounted duplex RTD, Weld pad and dual sensors & Cable glands, Range max (0 to 100 0C); Smart type; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted ; RTD in weldpad welded to process pipe surface for below ground installation.
SCADA_SYSTEM_COMPOSITE_PHB_JH
INSTALLATION OF RTU PANEL as per Scope of work.
Steel structural works as per Scope of work.
DISMANTLING WORKS as per Scope of work.
SCADA_SYSTEM_SUPPLY_PHB_BH
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for SCC Locations
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Fully integrated infrastructure racks with dedicated cooling (with Cooling redundancy), management, fire suppression, cable management, dehumidifier and power distribution with atleast 65U usable space as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, patch chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet.
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
Instruments Supply
IR Based explosion proof & weather proof (Point type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications.
Multisensor Detectors with relay output along with all mounting andother accessories for installation at BV-RTU locations as per the tender specifications.
Pressure Transmitters Remote Seal Type with cable glands Range max (0 to160 kg/cm2); Smart type; accuracy 0.075% or better Installation: Underground to process pipe. Transmitter: 2" pipe Mounted.
Temperature Transmitter with surface mounted duplex RTD, Weld pad and dual sensors & Cable glands, Range max (0 to 100 0C); Smart type; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted ; RTD in weldpad welded to process pipe surface for below ground installation.
Spares
Spare Host Server with OS and Virtualization and other associated softwares for SCC Locations
SCADA_SYSTEM_SERVICES_PHB_BH
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At SCCs
Conversion of Machine running for Control and F&G system from Physical to Virtual using Virtualization tool. (This excludes charges of moving of software licenses of the machine being moved, License related issues of the machine being moved shall be taken care by owner )
SCADA_SYSTEM_COMPOSITE_PHB_BH
INSTALLATION OF RTU PANEL as per Scope of work.
Steel structural works as per Scope of work.
DISMANTLING WORKS as per Scope of work.
Installation, testing & commissioning of various types of detectors including supply and Laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building for integration of detectors with RTUs including all mounting accessories for support, junction boxes etc. as per the approved scheme to complete the work in all respects inclusive of supply of all consumables,cost of all materials, labour, painting services etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includesinstallation of detectors, material etc
Multi Sensor Detectors & isolators
SCADA_SYSTEM_SUPPLY_PSH_OD
32 bit RTU for attended stations for interfacing of the control system with SCADA system c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant field interrogation power supply & DC-DC converters, Data Panel (wherever applicable), communication ports, serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc (RTU-CATEGORY-C)
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for BMCS Locations
Host Server with OS and Virtualization and other associated softwares for SCC Locations
VM Backup Server with OS and associated softwares for MMCS/BMCS
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
LED Display Unit (50" or above) as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 48 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-I) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
GPS Time Server for time synchronization of all MCS / SCC computers and control system computers as per the tender specifications.
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Fully integrated infrastructure racks with dedicated cooling (with Cooling redundancy), management, fire suppression, cable management, dehumidifier and power distribution with atleast 65U usable space as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, patch chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet.
Software including one time license fee for the following
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
Programming / ladder logic / testing software for Yokogawa make RTUs including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Network management System software for multisite networks having different IDs for a minimum of 1000 SNMP / ICMP ports (1 Set - 1 Software license with all components)
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
Spares
Spare Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications
Spare Host Server with OS and Virtualization and other associated softwares for BMCS Locations
Spare Host Server with OS and Virtualization and other associated softwares for SCC Locations
SCADA_SYSTEM_SERVICES_PSH_OD
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At MMCS/BMCS
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At MMCS/BMCS
At SCCs
Erection, testing & commissioning of Yokogawa make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
Installation, testing & commissioning of Application Server(s) at MMCS/BMCS locations with fine tuning and commissioning of Application Software for leak detection, pig tracking etc. including hardware / software complete as per tender specifications & configuration and acceptance by Owner for PHBPL, PSHPL and 18" HBPL. This includes labour, consumables, tools, services rendered etc.
BMCS location
SCADA_SYSTEM_SUPPLY_PSH_WB
32 bit RTU for attended stations for interfacing of the control system with SCADA system c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant field interrogation power supply & DC-DC converters, Data Panel (wherever applicable), communication ports, serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc (RTU-CATEGORY-C)
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for MMCS Locations
VM Backup Server with OS and associated softwares for MMCS/BMCS
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
LED Display Unit (50" or above) as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 48 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-I) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
GPS Time Server for time synchronization of all MCS / SCC computers and control system computers as per the tender specifications.
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Fully integrated infrastructure racks with dedicated cooling (with Cooling redundancy), management, fire suppression, cable management, dehumidifier and power distribution with atleast 65U usable space as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, patch chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet.
Software including one time license fee for the following
SCADA software for MMCS and BMCS with Clients software with minimum database tags of 90000 (including one time licence fee) etc. as per tender specification. Software for the SCADA Servers at MMCS and BMCS/ Client Servers / OPC Servers / Historian Servers / Web Servers / Backup Storage/SysLog server, Engineering Terminal, VM manager server etc. (as applicable for different stations). Software is to be supplied as "Set" and all required licences for different machines per station to be supplied under the "Set":
Redundant Main Master Control Station at Haldia, Backup Master at Paradip and Clients of Various systems at SCCs (Complete Software package for Hostservers including virtualization software as per software list mentioned in the tender document) (1set means software for all locations under PHBPL+PSHPL+18"HBPL)
"The SCADA software modules shall include but not limited to the following: • Data Acquisition • Alarm Processing • Event processing • Control Processing/ Commands • Data Display • Message Display • Overview Display • Trend generation as defined • Data Failure • Status Change Annunciation • Management information Report Generation • Man - Machine Interface • CP performance package • GPRS Software Module"
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
Programming / ladder logic / testing software for Yokogawa make RTUs including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Supply of new Pipeline Application Software (PAS)/Upgradation of existing PAS software into 2+1 configuration and Moving the same to Virtualized Environment including supply of new Apps Clients & one time license fee etc. in hot standby dual redundant servers at Haldia and Paradip for PSHPL, PHBPL and 18" HBPL complete as per the tender specifications, including the HMI client along with license for the all the SCADA workstation machines. (1Set- Software in 2+1 configuration for haldia and Paradip for PSHPL+18" HBPL+PHBPL)
Network management System software for multisite networks having different IDs for a minimum of 1000 SNMP / ICMP ports (1 Set - 1 Software license with all components)
Antivirus software for Server (1 Set=1 Server). Server will get update from SCADA Vendors works. From this server updates shall be pushed to clients
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
Test jig for BV-RTU similar to the main BV-RTU equipped with processor module, power supply module, all communication modules, one number IO module of each type, toggle switches, lamps, potentiometers, panel meters etc complete with all hardware and licensed software for testing of various types of IO modules.
Spares
Fully equipped spare RTU consisting of all modules (Processor, power supply, IO modules, communication modules etc) similar to RTUs for RCP locations
Spare Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 48 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Spare Host Server with OS and Virtualization and other associated softwares for MMCS Locations
Spare Host Server with OS and Virtualization and other associated softwares for SCC Locations
SCADA_SYSTEM_SERVICES_PSH_WB
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At MMCS/BMCS
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At MMCS/BMCS
At BV-RTU (RCP/MOV) locations
Installation, testing & commissioning of Application Server(s) at MMCS/BMCS locations with fine tuning and commissioning of Application Software for leak detection, pig tracking etc. including hardware / software complete as per tender specifications & configuration and acceptance by Owner for PHBPL, PSHPL and 18" HBPL. This includes labour, consumables, tools, services rendered etc.
MMCS location
Training of Owner's personnel as per tender specifications
Deputing Resident Engineer during defect liability period
Submission of As Built Documentation for Complete Pipelines considered under the project
SCADA_SYSTEM_SUPPLY_18HB_WB
32 bit RTU for Haldia Boosting and 18" HBPL Bolpur stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant field interrogation power supply & DC-DC converters, Data Panel, communication ports for connectivity(including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-B) These RTU is to be supplied with Data Panel.
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
FLOW COMPUTER as per tender specifications.
IT HARDWARE
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
SCADA Workstations with OS and SCADA Client software for Haldia Boosting Station.
Workstations for Local RTU Control with OS and HMI software for Haldia Boosting Station
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Server Cabinet as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, Patch Chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet. Server cabinet is to be used for housing of the new machines.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
SCADA_SYSTEM_SERVICES_18HB_WB
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At Type-B RTU Locations
At BV-RTU (RCP/MOV) locations
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
SCADA_SYSTEM_SUPPLY_18HB_JH
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for SCC Locations
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
LED Display Unit (50" or above) as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Server Cabinet as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, Patch Chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet. Server cabinet is to be used for housing of the new machines.
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
SCADA_SYSTEM_SERVICES_18HB_JH
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
Modification in Schneider Make RTUs including interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc.
At SCCs
SCADA_SYSTEM_SUPPLY_18HB_BH
32 bit RTU for attended stations for interfacing of the control system with SCADA system c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant field interrogation power supply & DC-DC converters, Data Panel (wherever applicable), communication ports, serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc (RTU-CATEGORY-C)
32 bit RTU for RCP/MOV stations c/w processor module, I/O modules, relay modules, rack power supplies, dual redundant DC-DC converters, Data panel, communication ports for connectivity (including GSM / GPRS), serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications etc. (RTU-CATEGORY-A). These RTU is to be supplied with Data Panel.
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM router should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service providers like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
Zener Barriers as per tender specifications.
For AI
Surge Protection Devices as per tender specifications.
For RS 232/485 signals
IT HARDWARE
Host Server with OS and Virtualization and other associated softwares for SCC Locations
Supply of Rackmount 8 port USB to IP Converter Device for virtual machine access to USB access keys (Dongle)
Supply of Thin Clients (with keyboard, mouse etc.) as per detailed Technical Specifications
Supply of 23" Display Monitor as per tender specifications.
LED Display Unit (50" or above) as per tender specifications.
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistant, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s/w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors & peripherals etc. complete in all respects as per tender specifications
Networking Hardware
Industrial Grade L3 Ethernet Switch (having 4 Nos. of 10Gbps ports & 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
Industrial Grade L2 Ethernet Switch (having 24 Nos. of 10/100/1000 MBPS ports) with cables & connectors etc. complete in all respects as per tender specifications (1 Set Comprises of 2 switches)
16 Port WAN Router system for master stations and other stations for connectivity with software, cables, connectors etc complete in all respects as per tender specification
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cords, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 1 LIUs and 2 converters)
Firewall (Type-II) for SCADA system to ensure SCADA security as per tender specifications complete with cables, connectors, software etc.as per specifications
LaserJet Printer with Dual LAN, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per Tender specifications
Power cable 2.5sqmm Supply as per tender specifications.
CAT6 Cable (armoured) as per tender specifications.
CAT6 Cable (Unarmoured) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 2 Mtr (reputed make) as per tender specifications.
Cat 6A, LSZH, Stranded Patchcord, 1 Mtr (reputed make) as per tender specifications.
Server Cabinets
Server Cabinet as per tender specifications along with draw out type LCD, Keyboard, Patch Panels, Patch Chords and KVM switch complete for mounting of various IT hardware like SCADA servers, Programming terminal, network hardware etc complete as per tender specifications & datasheet. Server cabinet is to be used for housing of the new machines.
Programming / ladder logic / testing software for new RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
HMI Programming Software for programming of the HMI on the data panel as per tender specifications.
Antivirus software for Clients machines to server (1 Set=1 Client Machine). Clients will get update from Server
SCADA_SYSTEM_SERVICES_18HB_BH
Erection, testing & commissioning of SCADA Servers / Historian Servers / Client Servers / OPC servers / Web Servers / Syslog servers/Operator Work Stations RTUs/Apps Clients / local area network / router / printers etc. ,as applicable for different stations, and commisisoning of the SCADA System, interfacing of the SCADA system with the PLC system, including supplied hardware / software with stations on remote & auto mode including development and implementation of data base, HMI graphic screens, control logics etc. making all jobs complete as per drawings / specifications and acceptance of system by Owner. This includes supply of all labour, consumables, tools, services rendered etc.
At SCCs
Erection, testing & commissioning of RTUs including supervision of termination of control cables, interfacing &integration of PLC /RTU with MCS/SCC machines and field instrumentationsystems including supplied hardware/ software with station on remote&auto including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At SCCs
At BV-RTU (RCP/MOV) locations
Modification in Emerson Make RTUs including supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS and field instrumentationsystems with station on remote&auto incl uding development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system byOwner for PHBPL, PSHPL and 18" HBPL. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site
At BV-RTU (RCP/MOV) locations
SCADA_AMC_FOR_PHBPL_PSHPL&18HBPL_OD
Supply, installation, testing and commissioning of Station RTU as per tender specifications during defect liability/AMC period for any indianoil pipeline location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. (1 Set= Per RTU location)
Supply, installation, testing and commissioning of RTU for unmanned RCP/MOV location with 3G/4G modems as per tender specifications during defect liability/AMC period for any indianoil pipeline Location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site. (1 Set= Per RTU location)
Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location)
Supply, installation and commissioning of additional SCADA Client License with OS and Microsoft office License (Excluding IT hardware) and configuring the same to the owner's provided Virtual/Real Machine for display of SCADA data complete in all respects.
SCADA_AMC_FOR_PHBPL_PSHPL&18HBPL
Comprehensive Annual Maintenance Contract for the complete system (including supplied facilities at all the attended stations, Scrapper location, RCP locations, MOV locations) for a period of 05 years after completion of defect liabillity period for the complete pipeline as per tender requirement for all locations of PHBPL, PSHPL and 18" HBPL
AMC for 1st Year
AMC for 2nd Year
AMC for 3rd Year
AMC for 4thYear
AMC for 5th Year
Deputing Resident Engineer at Haldia during AMC period for all locations of PHBPL, PSHPL and 18" HBPL
Supply, installation, testing and commissioning of Station RTU as per tender specifications during defect liability/AMC period for any indianoil pipeline location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. (1 Set= Per RTU location)
Supply, installation, testing and commissioning of RTU for unmanned RCP/MOV location with 3G/4G modems as per tender specifications during defect liability/AMC period for any indianoil pipeline Location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site. (1 Set= Per RTU location)
Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location)
Additional modifications in SCADA/Historian/Webserver database for creation of additional tags, modification in graphics screens of SCADA Clients, Web pages, configuring additional users complete in all respects as per the directions of EIC. The modification works in SCADA/Historian/Webserver may include work for any IndianOil Pipeline.
Upgradation/ modification of the Pipeline Application Software (PAS) system at MMCS/BMCS locations to include the facilities of a new pipeline section (upto 300km) or change in configuration of existing pipeline and its parameters including linking with GIS data of the pipeline, fine tuning, & commissioning of Application software of MMCS/BMCS with necessary opearting system software, pipeline application software for leak detection, batch tracking etc. Job should be completed including hardware/ software, licensing requirement & configuration and acceptance of system by owner. This includes all labour, consumables, tools, services rendered etc.
Supply, installation and commissioning of additional SCADA Client License with OS and Microsoft office License (Excluding IT hardware) and configuring the same to the owner's provided Virtual/Real Machine for display of SCADA data complete in all respects.
SCADA_AMC_FOR_PHBPL_PSHPL&18HBPL_JH
Supply, installation, testing and commissioning of Station RTU as per tender specifications during defect liability/AMC period for any indianoil pipeline location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. (1 Set= Per RTU location)
Supply, installation, testing and commissioning of RTU for unmanned RCP/MOV location with 3G/4G modems as per tender specifications during defect liability/AMC period for any indianoil pipeline Location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site. (1 Set= Per RTU location)
Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location)
Supply, installation and commissioning of additional SCADA Client License with OS and Microsoft office License (Excluding IT hardware) and configuring the same to the owner's provided Virtual/Real Machine for display of SCADA data complete in all respects.
SCADA_AMC_FOR_PHBPL_PSHPL&18HBPL_BH
Supply, installation, testing and commissioning of Station RTU as per tender specifications during defect liability/AMC period for any indianoil pipeline location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. (1 Set= Per RTU location)
Supply, installation, testing and commissioning of RTU for unmanned RCP/MOV location with 3G/4G modems as per tender specifications during defect liability/AMC period for any indianoil pipeline Location. Commissioning includes supervision of termination of control cables, interfacing &integration of RTU with MMCS/BMCS machines and field instrumentationsystems including development of control logics etc making all jobscomplete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables, tools, servicesrendered etc. and installation and commissioning of 3G/4G modems at site. (1 Set= Per RTU location)
Interfacing of additional RTUs (manned/Unmanned) with SCADA System, Modifications in SCADA/Historian/Webserver including adding the RTU to SCADA System, creation and configuration of Tags in SCADA systems/Historian/Webserver and modification in graphics screens of SCADA Clients and Webserver, testing of control using SCADA System etc. complete in all respects as per the directions of EIC. (1 Set= Per RTU location)
Supply, installation and commissioning of additional SCADA Client License with OS and Microsoft office License (Excluding IT hardware) and configuring the same to the owner's provided Virtual/Real Machine for display of SCADA data complete in all respects.
Bidder Name
Amount in Words
Yokogawa India Limited
ELECTRONICS CORPORATION OF INDIA LIMITED
ELECTRONICS CORPORATION OF INDIA LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid