| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹26.7 L+₹2.7 L (11.4%)Rejected-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹28.4 L+₹4.4 L (18.5%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹30.7 L+₹6.7 L (28.0%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹34.1 L+₹10.1 L (42.1%)Rejected-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹73,400
Closing Date
27 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 49 2022 23 SPL REPAIR TO MAIN DISTRIBUTION BOX IN JADHU NATH ENCLAVE UNDER GE NORTH UDHAMPUR
2022_MES_555400_1
GE/U(N)/49/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹73,400
Yes
7 Dec 2022
30 Sept 2022
29 Oct 2022
30 Sept 2022
27 Oct 2022
13 Oct 2022
Amount
M&L for taking down care fully old worn out electric LT panel by descrewing from wall after disconnecting all incoming and outgoing connections and making good all disturbed surface of wall including taking out all energy meters and MCCB 160/100 Amps four pole without damaging for fixing in new locationcomplete all as specified and as directed by Engr-in-charge
M&L for taking down carefully old sheet metal enclosure TPN/DB including MCB,s.complete all as specified and as directed by Engr-in-charge
S & F CRCA powder coated sheet metal VTPN DBs MCCB160 Amp as in incomming (160 Amp+12Way) WITH 250 Amp copper bus bar for each phase with metal door 415 volts grade IP 43-IK-09 Protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs complete all as specified and as directed by Engr-in-charge
S & F Thermal magnetic MCCB 4 pole 160 Amps 415 Volts 16 Ka INCLUDING MAKING NECESSARY ARRANGEMENT complete all as specified and as directed by Engr-in-charge for MCCB DB
S&F VTPN MCCB DB , 4 ways for 100 amps MCCB with 200 amps copper bus bar for each phase with metal door ip-43 protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs complete all as specified and as directed by Engr-in-charge
S&F MCCB 4 pole 100 amp 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT complete all as specified and as directed by Engr-in-charge for MCCB DB.
S&F factory made/flush type sheet metal enclosures double door type for MCB DB 4 Way (8+12 Module)TPN 415V shutter with 125 Amp rated bus bar, IP 43 protection complete all as specified and as directed by Engr-in-charge
M&L for sub main wiring with two run of 6 Sqmm (2x6 Sqmm) 1100 Volts grade single core FR PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metallic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on surface of walls /roofs / ceiling including cutting chasing with complete plaster work and painting and with one run of 6 Sqmm (1x6 Sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and as directed by Engr-in-charge
M&L for taking down carefully old sub main wiring of 2x46Sqmm + 1x6 Sqmm. complete all as specified and as directed by Engr-in-charge
S&F connection and testing MCB SP6-32 Amps complete all as specified and as directed by Engr-in-charge
S&F connection and testing MCB SP 40 to 63 Amps complete all as specified and as directed by Engr-in-charge
Supply & laying GI tubing light grade with all fittings (Incl MS Clamps alongwith nut bolts and washers etc as per site requirments) laid in trenches or fixed on wall along with wall / poles of size 40 mm dia complete all as specified and as directed by Engr-in-charge
Supply and laying XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing complete all as specified and as directed by Engr-in-charge
M&L for excavation in trenches in any type of soil n exc 1.5m deep and not exc 1.5m wide for laying of under ground cable, electric pole and getting out complete all as specified and as directed by Engr-in-charge
M&L for returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil complete all as specified and as directed by Engr-in-charge
M&L for removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable complete all as specified and as directed by Engr-in-charge
Supply and laying brick class ‘B’ covering as mechanical protection to cable with well burnt complete all as specified and as directed by Engr-in-charge
S&F of TPN 63 Amps, 415 Volts. Complete all as specified and directed by Engr-in-Charge.
M&L for taking down serviceable/ unserviceable electric meter including meter box from existing position carefully for refixing including making good to disturbed surfaces complete all as specified and as directed by Engr-in-charge (Note : Disturbed surfaces should making good by Plastering / distembering / colour washing / white washing to match with existing surfaces)
M&L for re fixing of serviceable electric meter obtained from item No 13 with meter box by scouting to the wall and fix firmely with wooden box complete all as specified and as directed by Engr-in-charge
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test pointcomplete all as specified and as directed by Engr-in-charge or indicated including testing on complition with following:- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the Engr-in-charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
m/s shanti trading company
DEV RAJ MAGOTRA
SATYA SALES AND BUILDERS
RANBIR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .