| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹38.8 L+₹3.4 L (9.69%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹39.5 L
EMD Value
₹77,000
Closing Date
23 Aug 2022, 6:00 pmClosed
GE North Bikaner
GE North Bikaner Rajasthan bikaner 334001
PROVN OF TWO TOILET BLOCK AT PT 220 AND 223 AT WEST CAMP AND PROVN OF 22 GEYSERS 368 I SUP PL ASC 608 I TK TPTR PL ASC 612 I TK TPTR PL ASC AT ADM CAMP NORTH CAMP AND SPL REPAIR TO BLDG NO T35 T36 T37 T38 T39 T40 T41 T163 AT CUL 4 OF SOUTH CAMP AND
2022_MES_540648_1
GE (N) BKN TOKEN NO 38 /2022-2023
Open Tender
Miscellaneous Works
Item Rate
270 days
MFFR
Class D category a i
7 documents required · 7 mandatory
₹500
GE North Bikaner
₹77,000
Yes
30 Sept 2022
25 Jul 2022
30 Aug 2022
25 Jul 2022
23 Aug 2022
10 Aug 2022
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridge complete
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), all as specified and directed by Engineer-in Charge.
Dismantling Wall and ceiling boards or insulation boards, any thickness,any description, including cover fillets complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips including providing and fixing new ones complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick/stone masonry built in CM. all as specified.
Taking up or down steel tubing 15 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-
Taking up or down steel tubing 20 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-
Dismantling100mm cast iron /PVC pipes fixed to walls or laid in trenches in any position.
Dismantling water tanks and removing to store exc 1000 ltrs and nexc 2000 ltrs
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etcor notexceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes,, etc and getting out in loose/soft soil complete..
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer complete.
Removing excavated soil not exceedind 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including base of manholes etc complete.
M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
M&L 75mm thick PCC 1:4:8 type D-2 using 40mm gaded stone aggregate as in sub base in floors and paving, laid in panels and finished even & fair complete.
M&L non skid ceramic tiles 7 to 8 mm thik (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors on 15mm thick screeding in CM 1:6 set set and jointed in neat cement slurry and pointed in white or coloured cement to match complete.
M&L for Glazed ceramic coloured tiles in vertical surface 300x 200x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on 10mm thick screeding in CM 1:4 complete.
S & F refixing' incldues taking down,Resecuring or easing & adjusting, without taking down easing and ajusting and also refixing builders hardware as Refixing in same Opening required including renewal of unserviceable screws, etc.
S&F Pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate of profile 105x60mm
S& F Flush shutters,30 mm thick door solid core construction, with block board core and plywood face panels, commercial type on both sides
S&F factory made solid panel PVC door shutter with MS square tube 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top,lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement S&F in the steel frame at site as per specification.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and approved.
PCC 1:3:6 type B-1 using 20mm graded aggregate as in bed blocks of hold fasts etc.
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of oil Bound Distemper white or tinted over a coat of white wash complete.
M&L for washing rubbing down and stopping of distempered surfaces of walls and applying two coats of oil Bound Distemper white or tinted complete.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over a coat of white wash complete.
M&L for washing rubbing down and stopping of painted surface of walls and applying two coats of cement paint white or tinted complete.
S&F 3mm sheet glass, ordinary quality and glazing with oil putty in squre n exc 0.5sqm in each pane but forsted.
Providing cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in cills, bed block, copings,bed plates, bond stone, etc including weathering, slightiy rounded or chamfered angles and throating as directed including necessary form work complete.
M&L for preparation new or previous untreated steel & iron surfaces of any description over 10cm in with or grith and applying two coats of synthetic enamel paid over & including a coat of red oxide primer complete.
S&F Chromium plated shower rose with swivel joints 75mm size
S&F Tower Rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete.
S& F Urinal and Wash Basin Waste Pipe 32mm bore flexible pipe for disposal as specified as dircted
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 190 gms) complete.
S&F Vitreous china bowl urinal Haif stalf type, white, with grating and union for discharge pipe including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including providing & fixing 5 litres cast iron automatic flushing cistern with brackets, 32 mm bore PVC waste pipe and 25 mm bore light grade GI flush pipe complete.
S&F PVC low level flushing cistern 10 litres capacity, white, with all fitting and fixtures including brackets and Bend Pipe with fixing and 32 mm bore PVC flush pipe, complete.
S&F in repair, white, vitreous china WC squatting pan, Orissa pattern 580mmx440mm size with integral foot rest, and connection to flush pipe/trap and connection to anti syphonage pipe etc. including making good to floor as per existing specifications complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete.
S&F PVC (SWR) pipes, single socketed,in any length with rubber ring joints, fixed to walls, 75mm bore complete.
S&F PVC (SWR) bends any radius, 110mm bore complete.
S&F PVC (SWR) branch pieces, single (single Y) equal or uneqal, 110mm bore complete.
S&F PVC (SWR) couplers, 110mm bore complete.
S&F PVC (SWR) 'P' trap, 125/110mm bore complete.
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75 mm complete.
M&L for 15mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete.
M&L for 20mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete.
S&F Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of 2000 litres capacity, hoisted and fixed in position including connecting up pipes complete.
S&F Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes complete.
S&F Bib taps cast copper alloy Chromium Plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete.
S&F Vitreous china wash basin, white, flat back, size 550 x 400mm, including brackets and cutting for and pinning in ends of brackets, and including waste Pipe and waste Coupling complete.
S&F angle valves, cast copper alloy, cp fancy type screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, 15mm bore complete.
S&F pillar tapes, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete.
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15mm bore complete.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (Minimum weight 210 gms) complete.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete.
S&F Steel ventilators with top hung shutter including hinges, steel peg stay complete.
S&F Aluminium anodised barrel tower bolts of extruded section, 150 mm long complete.
S&F Aluminium alloy, anodised, sliding door bolt 250 mm long, with haps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete.
S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size complete.
S&F Extruded aluminium alloy handles, fabricated type, anodised, 150 mm size complete.
Salt glazed stone were drain pipes, grade ‘A’ 150 mm bore (internal dia) laid in trenches over existing concrete bedding and jointed as specified
Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in packing under and hunching against the sides of pipes, without bedding layer, after they are laid and tested in 150 mm dia of pipe complete all as specified
Cutting into existing manholes or connecting new, drains making good existing benching or forming channel and reforming benching with cement and sand mortar 1:4 or PCC 1:2:4 type B-1 smooth finished and reforming benching as in 150 mm dia of pipe complete all as specified and as directed by Engineer-in-Charge
M&L for 75mm thick Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, , finished even and smooth using extra cement , laid in panels including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
De-sludging by removing of semi solid sludge from existing septic tanks of any depth, any capacity in foul condition, including taking and placing in position the manhole cover of any description, removal of sludge & solid content to any place outside defence land and deposting where directed by Engineer-in-Charge.
Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete (reinforcement to be measured separately)
M&L for Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete.
S&F joist , channel, angle, tee section, fixed independently without connecting plates etc. including welding as necessary confirming to Fe-290 Gde E-165
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St-240, conforming to Fe- 290 Gde E-165 complete as directed by Engineer-in-Charge and all as specified.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 all as specified and as directed by Engineer-in-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm and dia of shank 5 to 10 mm complete all as specified and as directed by Engineer-in-Charge.
M&L Roughly squared stone lintels hammer dressed on face and soffits, hoisted, set and pointed in cement mortor 1:6 n.exc 3 m in length complete all as specified and as directed by Engineer-in-Charge.
M&L 5cm thick sand stone slabs in shelves, chajjas, shelves etc n exc 2m in length set and pinted in CM 1:4
Soakage wells exc, in any type of Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR Masonry/ Filling with brick bats complete of size 1.8 M dia X 3.0 M deep.
S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as complete all as specified.
S & F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in ridge roof covering /cladding to wall, fixed with self tapping screws as complete all as specified.
Supply and fixing anodized snap grid frame work of size 605mm x 605 mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross tee of size 36.5 x 25 x 1.4 mm weighing 0.24 Kg/RM and 23.5 x 26.4 x 1.40 mm weighing 0.191 Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminum angle bracket of size 15mm x 15mm x 1.5 mm weighing 0.12 Kg/RM fixed with suitable MS bolts, nuts and washer. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminum angle of size 35 x 25 x 2 mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and providing 12 mm thick mineral fibre board fixed in grid support with 2.50 mm dia plain mild steel wire galvanised class 3 fixed in detached works etc to support snap grid, made of aluminum as per specification and omplete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc complete all as specified and as directed by the Engr-in-Charge.
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including new non-metallic rigid PVC concealed conduit, not less than 20 mm dia, medium duty ISI marked, including conduit fittings such as tees, bends etc terminating in and including new sunken box covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 83 here-in-before but socket point on independent board complete as specifed as directed by Engineer - In - Charge
All as per item No 83 here-in-before but cable 2.5 Sqmm for 15 Amps switch socket outlet on independent board complete as specifed as directed by Engineer - In - Charge
S&F Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge S&F Socket outlet 2 in 1, 3 pin, 5A ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F Socket outlet 2 in 1, 3 pin, 5A ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F switch socket combination 5 in 1, 5/16 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F Lamp holder insulated body with back plate for conduit/casing capping fittings complete all as specified and as directed by Engineer-in-Charge Make : CG/Havells/Phillips.
S&F Ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge.Make : CG / havell's / Phillips.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louver
Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 4 ways double door , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/ GE/Seimens/L&T/Schneider/Indo Asian/C & S/Strandard/BCH/HPL
S&F MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make : Legrand / Schneider / ABB/ Havells
MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH /Havells
S&F Decorative ultra slim linear LED lightening fixture, energy efficent 18 Watt complete all as specified and directed by engineer-in-charge.Make SYSKA/BAJAJ/PHILIPS/C.G/wipro
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 sq mm 2 core
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 mtr in depth for route of cable and getting out complete all as specified and as directed by the Engr-in-charge.
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class 'B' bricks complete all as specified and directed by Engr-in-charge.
Local tibba dry sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-charge. Note Local approved tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning.
M & L GI tubing light grade for protection of cables with pole/ in ground of size 40mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.
Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping .
Supply, laying and testing Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power under ground cable ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 4 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
Boring of holes 110 mm dia, manually without disturbing the top surface for laying of cables/GI pipes under road , pavement, hard standing complete all as specified and as directed by the Engineer-in-Charge.
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with effectie thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 4500 lumens and maximum system wattage 45 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be wthstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make:- CG/Phillips/Wipro
Supply and fixing thermplastic cable junction box with IP 66/67 weather prrof protection for outdoor installation with knockouts for cable entry of size 205x255x122 mm suitable for LT UG cable 10 Sqmm to 25 Sqmm Make Hensel / Sintex
Supply & fixing FRLS PVC insulated Copper conductor, two single core of size 1.5sqmm complete for terminal box to street/ flood light fitting.
Supply,fixing, testing and commissioning electric storage water heater (Geyser) vertical type with glass lined tank of capacity 25 Ltrs, BEE and minimum 5 Star Rating on wall including grouting suitable size of nuts, bolts and washers and making good the surfaces of walls to match with the existing surface including PVC connection, transportation up to site complete all as specified and directed by Engineer in charge.
M&L new sub main wiring with 2 single core, multi-stranded PVC insulated cable unsheathed 1100 volts grade with copper conductor of size 4 sq mm drawn in and including PVC conduct /casing capping including earth continuity conductor cable of size 2.5 sq mm PVC insulated unsheathed copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volt. complete all as specified and directed by Engineer in charge.
Supply and fixing stop cock cast iorn fency chromium plated type for 15mm bore GI pipe complete all as specified and directed by Engineer in charge.
S&F bib Tap fency chromium plated type, 15mm bore, cast cooper alloy with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed by Engineer in charge.
Supply and fixing GI pipe 15mm medium grade with all fittings complete all as specified and directed by Engineer in charge.
Supply and fixing GI pipe 20 mm medium grade with all fittings complete all as specified and directed by Engineer in charge.
S&F sheet metal enclosure DB 12 way, SPN single door with 200 rated bus bar complete all as specified and directed by Engineer in charge.
S&F sheet metal enclosure DB 2 way, SPN single door with 200 rated bus bar complete all as specified and directed by Engineer in charge.
S&F MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, stranded conductor 1100 volts grade heavy duty cable, two single core, with PVC insulated aluminium conductor served with an inner sheahing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq mm nominal cross section in service connections.
Supply and laying or fixing or passing through pipe, stranded conductor 1100 volts grade heavy duty cable, three single core, with PVC insulated aluminium conductor served with an inner sheahing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq mm nominal cross section in service connections.
Supply and fix Rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fix in position all as specified
Supply and fixing Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ballscrewed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm-690gms
Supply and fix Nipple suitable for HDPE water tank.(Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms)
M/S Shree Ram Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .