| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹41.2 L+₹1.6 L (4.04%)Rejected-AOC | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹48.3 L+₹8.7 L (22.0%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹49.1 L+₹9.5 L (24.0%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
₹56 L
EMD Value
₹1.1 L
Closing Date
13 May 2024, 6:00 pmClosed
COMMANDER WORKS ENGINEERS PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
84828 REPAIR, MAINTENANCE, REPLACEMENT OF HT 11KV RING MAIN DETERIOTED CABLE AT HQ CESC, SCOM, 16 QG, SFC, ZRO, NEWRSI, GURUDWARA ROAD, KOHIMA LINE, KG LINE, TELEPHONE EXCHANGE SUBSTATION ETC IN THE AREA OF AGE EM UNDER GE (NORTH) PUNE
2024_MES_649533_1
84828 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE (NORTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (NORTH) PUNE
₹1.1 L
Yes
22 Jun 2024
6 Apr 2024
15 May 2024
6 Apr 2024
13 May 2024
29 Apr 2024
Amount
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth for laying of UG cable/pole foundation etc getting out including forming bottom surface to required level and gradient in soft/loose soil complete all as specified and as directed.
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 Cm thick complete all as specified and directed.
Removing of excavated materials not exceeding 50 metre and depositing where directed by Engr in Charge at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Dehydration and filtration of the existing transformer oil by Dehydration plant to achieve di-electric strength of 60 KV at the gap of 4mm complete all as specified and directed by Engineer-in-charge. (Notes :- Dehydration plant shall be brought at site by the contractor and shall also include the following provisions :- a) Testing of transformer oil before & after dehydration shall be carried out as directed. b) The Unit of payment under this item shall be per liter of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every eqpt as per format given by Engr-in-charge and submit the same to Engr-in-charge.
Supply and filling mineral grad transformer oil EHV type conforming to IS-335 of 1983 for topping up or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and as directed by the Engineer-In-Charge. Make- Power oil/ Savita/ Apar/ Transpower Note: - The entire quantity of transformer oil shall be procured in one go. The complete material shall be brought at site and then as per requirement oil should be shifted to site. Cost of this aspect deemed to be included in the quoted rate
Supply and replacement of dehydrating agents (Silca gel) in transformers of capacity upto 1000KVA transformer outdoor/indoor type complete all as specified and as directed by the Engineer-In-Charge.
Supply and replacement of LT bushing (Brass stud and bolts with porcelian insulator) suitable size to fixed the transformer capacity range 100 to 1000 KVA including replacement of gasket , cable glands, etc to make the transformer leak proof complete all as specified and as directed by Engr-in-charge
All as per item ser No 07 above but HT Bushing suitable for 100 KVA to 1000 KVA transformer complete all as specified and as directed.
S & F in replacement of aluminium lugs duly crimped at end termination of Transformer/ LT distribution panel connected with various sizes of LT cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable and refixing the same with new metal gland all as specified and directed. (Note :- Each job includes the 04 Nos aluminium lugs at one end termination, insulating material and 01 No metal gland etc)
Upto 3.5 core x 35 Sqmm
3.5 core x 50 Sqmm
5 core x 70 Sqmm
3.5 core x 95 Sqmm
3.5 core x 120 Sqmm
3.5 core x 185 Sqmm
3.5 core x 240 Sqmm
3.5 core x 400 Sqmm
Checking the Fault in the HT and LT distribution cable of any size and length at any location ( up to and incl 11 KV) with fault detector machine and fixing only straight through cable joint kits (LT) and LT UG cable as required length after determining the fault location including earth work at any strata as required depth and width and testing complete all as specified and as directed by Engr- in- charge. (Note :- (i) Fault detector machine & other equipment shall be arranged by the contractor within 1 hour of complaint received including 24x7. (ii) Transportation charge for shifting cable fault locater will be deemed to be including in above said job and nothing extra on this account will be admissible. (iii) Cable jointing kit and LT UG cables shall be measured and paid seperatly as supply only under relevant items)
Supply only cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
3 core x 95 Sqmm
3 core x 120 Sqmm to 185 Sqmm.
M & L for cable end jointing kit 11 KV (Earthed ) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:- .
3 core x 95 Sqmm
3 core x 120 Sqmm to 185 Sqmm.
M & L for cable end jointing kit 11 KV (Earthed ) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for HT XLPE armoured aluminium conductor cable of following sizes:-
3 core x 95 Sqmm
3 core x 120 Sqmm to 185 Sqmm.
Supply and fix for switch air break gang operated HT 11 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based on 15 insulator complete set with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame vertical mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed.
S&F in replacement of unserviceable Automatic transfer switch 400 A, 4 pole, 36 KA, 440 volt 50/60 Hz inbuilt in sheet metal enclosure with adjustable thermal & fixed magnetic setting relay with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S & F for Insulator Pin/ post type polymer based including one galvanishing MS spindle, nuts & washers for 11000 volt grade and fixing to the structure and binding of conductor including removal of unserviceable one from the HT 2 pole/ 4 pole structure complete all as specified and directed.
S & F for Alkathine PVC pipe for bus/ jumper (RYB) connection as insulating material at 4 pole/ 2 pole structere in the area complete all as specified and directed.
S & F for HT Aluminium ferrules/ lugs of suitable size with chromium plated nut bolts for connection of GOD/DO/ cable end jumpers including removal of unserviceable one complete all as specified and directed
S & F for Aluminium tubing heavy duty of size 32 mm outer dia 12 mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed
Taking down the existing servicable incoming and out going HT/LT UG cable of any type/ description with all connections from panel/transformer/GOD etc near 2/4/6/8 pole structure and relocate and reconnections with necessary excavation of soils and replacement of cable lugs, bolts and nuts etc complete all as specifified and directed.
Supply and Fixing chain link MS galvanised fencing of 5 mm thick GI line wires, 65 x 65 mm mesh and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
M&L for crushed stone aggregate of size 35 to 40mm spreading over sand layer in the sub station areas including proper levelling all as directed and shown at site all as directed by Engr-in-Charge.
M&L for crushed stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling complete all as directed by Engr-in-Charge.
Labour only for painting and repair to HT 11 KV, 4/6/8 pole structure of 11 meter height steel poles including replacement of all perished ACSR conductor (ferret) of Horizontal bus bar and down conductors for GOD system on structure, jumpering and binding with aluminium conductor to the post insulators/ pin insulators and providing PVC sleeves to the down conductor with colour code R, Y & B, replacing all rusted nuts & bolts on the four pole structure complete all as specified and directed.
All as per ser. item No. 26 above but for two pole strtucture complete all as directed. (Note for item No 26 & 27 - Spares required shall be measured and paid seperately)
M & L for thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approvrd size, for LT, 20 x 15cm size all as specified and directed
M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approvrd size, for HT, 20 x 20 cm size complete all as specified and directed
Taking out old unserviceable & perished panel board doors/ body from the panel board replace with same size made out of CRCA sheet of 3.00 mm thick duly fabricated welded the door hinges and having proper locking arrangement to the existing LT panel doors by means of replacing the door hinges, nuts bolts & washers etc and making doors operatable in and including two coats of synthetic enamel paint over a coat of red oxide primer with spray painting match with existing colour complete all as specified and directed. (Note :- T&P as required shall be arranged by the contractor such as welding machine etc.)
M & L for painting of feeder pillar/ out door LT panels/DG sets at various places including scraping rusts, cleaning of duct and preparing old surfaces and paint applying of two coats of synthetic enamel paint over the surface of panel board with spray painting complete all as specified and directed.
Supply and fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed.
Supply and fix in replacement MCCB 3 Pole, 415 V, adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 3 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 3 Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 4 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 4 Pole, 415 V, adjustable type type 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
Supply and fix in replacement MCCB 4 Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for maintenance and overhauling of ACB 630 Amps to 1250 Amps capacity including de-assembling all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re assembly, fine setting of mechanism and pole assembly and making ACB perfect opeartional including well cleaning the complete bus bar chambers, insulator, partition etc and checking of insulation resistance of ACB main bus bar complete all as directed by Engr-in-Charge. (Note :- The work shall be carried out by OEM or their authorised representative. The spares required for the item shall be paid and measured separately under relevant items and cost of fixing shall be deemed to be included in this item)
Labour only for tree branch cutting of high rise trees, overhanging/interferences to the Two/Four Pole Structure GODs, HT / LT Lines etc (size of tree girth/ branch approx not exc. 50mm) without damages to the Two/Four Pole Structure/GODs/Transformer etc including thrown away the same alteast 100 Mtr away from the Sub Stn Yard complete all as directed. (Note for Ser. Item No. 40 to 42 below : (i) Each span between pole to pole shall be measured as one Job. (ii) Suitable arrangement i.e ladder, scaffolding or any other working platform required for climbing on high rise trees for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate (iii) Necessary safety measures shall be deemed to quoted rates)
All as per Ser. item No 40 above but grith exceeding 50 mm but not exceeding 100 mm complete all as specified and as directed.
All as per Ser. item No 40 above but grith exceeding 100 mm but not exceeding 150 mm complete all as specified and as directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing and Clearing off the shrubs, vegetation grass, bushes, plants and saplings grown below HT lines and all sub-stations in the area and clearing the rubbish material rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed by Engr-in-charge. (Note :- The Item shall be operated maximum 3 times in the entire period of the Contract and the measurement will be taken every time independently for Payment)
M & L for galvanised steel pipe 80 mm bore light grade laid in trenches etc complete as in protection of UG complete all as specified and directed.
Supply and Fix in replacement Automatic power factor controller 8 stage 415 volts AC 50 Hz power supply complete all as specified and directed.
S&F in replacement (LTXL) type MD ultra heavy duty box/cylindrical type LT 415/440 volts three phase 50 Hz Power Factor correction capacitors with Operating losses 0.35 W/kVAr, Peak Inrush current 500 x In, Max. Ambient temp 70 degree C and Over current withstand capability 3 x In of capacity 25 KVAR complete as per site requirement complete all as specified and directed.
All as per Ser. Item No 47 above but 15 KVAR capacity complete all as specified and directed.
All as per Ser. Item No 47 above but 10 KVAR capacity complete all as specified and directed.
Supply & fix in repairs/replacement capacitor type MO C10 Duty contactor 3 Pole, 415 V, capacity 10 kVAr, 2NO + 2NC having coil voltage 240 Volts conforming to Cat Part L&T Model No. CS96156 or equivalent here-in-after complete all as specified and directed.
Supply & fix in repairs/replacement capacitor type MO C15 Duty contactor 3 Pole, 415 V, capaccity of 15 kVAr, 2NO + 2NC having coil voltage 240 Volts conforming to Cat Part of L&T Model No. CS90019 or its equivalent specified here-in-after complete all as directed by Engineer-in-Charge.
Supply & fix in repairs/replacement capacitor type MO C25 delta Duty contactor 3 Pole, 415 V, capacity 25 kVAr, 2NO + 2NC having coil voltage 240 Volts conforming to Cat part L&T Model No. CS96322 or its equivalent complete all as directed by Engineer-in-Charge.\
Supply and fix for MCX 43, 4P Power Contactor 400Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed.
Supply and fix for MNX 225, 3P Power Contactor 300Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed.
Supply and fix for MNX 110, 3P Power Contactor 160Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed.
Supply and fix for MNX 50, 3P Power Contactor 45Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed.
Supply and fix in repairs Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigments all as directed and specified by Engineer-in-charge.
Taking up and replacing carefully paver blocks/ PCC blocks of any size and shape required to be displaced for excavation purpose of the cable laying including the sand/red bajri/shingles beneath the same and consolidating the same after refiling of the earth complete all as specified and directed.
M & L for Road cutting works / repairs of any depth incld scartifying or picking gravelled macadam or bituminius macadam surfaces in area not exc 400 Sqm exc 50 mm and not exc 100 mm deep removing the same to a distance 50 m and staking where directed and sweeping free from dust and mud or water scoring sunken surfaces in roads paths etc cutting around edges to at least 25 mm in depth making good by filling in screened makes good to the cut roads by PCC 1:2:4 for road cutting repair complete all as specified and directed.
Supply and Fix in HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 25 sq. mm complete all as specified and directed.
S&F in replacement of cable LT XLPE insulated screened PVC bedded, galvanized steel wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of the following sizes complete all as specified and directed by the Engineer-in-Charge :-
300 sqmm 3.5 core
185 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 100 Amps, 415 volts breaking capacity 10 KA complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300sqmm complete all as specified and directed.
M&L for disconnecting power supply from HT VCB of capacity upto 630 Amps, taking out trolley unit & complete servicing of the same through decarbonising, servicing & cleaning of the male/female isolating contacts, lubricating moving part, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, including cleaning of Vacuum Interrupter and all HT bushings, Cleaning of Flashes if any and refixing of cable by fixing the nut bolt, Washer to HT side tightly and refixing the trolley at its original position and testing and putting on load complete all as specified and directed by tightening all nuts and bolts of entire trolley, checking proper operation of trolley all as directd, inserting trolley inside, and testing and putting on load complete all as specified and directed. (Note : (i) The work shall be executed through OEM or their authorised Rep. (ii) The spares required to be replaced shall be paid for as 'Supply only' under respective item of BOQ. (iii) The cost of replacement shall be deemed to be included in this item)
Supply only set of mechanical castle inter lock assy with key suitable for HT 11 KV VCB of rating 630 Amps, make CG complete all as specified and directed.
Supply only closing coil assy 24/110 volts DC for VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only tripping coil assy 24/110 volts DC for HT 11 KV VCB of rating 630 Amps, make CG complete all as specified and directed.
Supply only fixed contact block of VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only moving contact block of VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only vacuum Interrupter , suitable for HT VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only Spring Charge motor & gear assembly 220 Volt AC suitable for VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only plug and socket assembly for VCB 11 KV 630 Amps capacity complete all as specified and directed.
Supply only auxilliary switch (6 No + 6 NC) for HT VCB 11KV 630 Amps capacity complete all as specified and directed.
Supply only 150 watts, 230 volts, AC, single phase rated strip heater with switch and thermostat for space for space heating complete suitable for VCB 11 KV , 630 Amps capacity complete all as specified and as directed by Engr-in-Charge
S&F in replacement for supply, testing, commissioning of DC control panel for 30 Volts DC lead acid chargeable stationery battery set comprising of 15 cells 02 volts each having 90 Amps hour capacity with maintenance free batteries including battery charging set adequate capacity and control equipment sheet steel cabinet , floor mounted type suitable for input of 230 volts, single phase , 50 Hz, AC complete with external and internal wiring of all components, accessories all as specified for 11 KV VCB panels complete control wiring (for connecting the DC tripping set to HT 11 KV VCB panel board complete) shall be copper conductor single copper conductor single core and size not less than 2.5 sqmm complete and comprising in and comprising in and including of the following accessories:- (a) DC ammeter/ voltmeter in 96 sqmm size (b) Step down Transformer (c) Choke to limit the inrush current (d) Variac (Auto-Transformer) for the manual stepless charging (e) Silicon rectifier stack (f) Auto-Off manaul switch (g) Set of protection fuses, (h) Set of indicating lamp to indicate position of charging on auto boost , auto trickle mains on, Battery earth and fuse failure (j) Battery switch to indicate the battery voltage (k) 15 Nos of 2 volts, 90 AH batteries in charge. (at RB)
Supply and fix in replacement over current & earth fault relay suitable for 11 KV VCB 400/630 Amps indoor control panel conforming to Cat Part L&T Model No MC31A or eqvt in Schneider /ABB/C&S complete all as specified and directed.
M&L for servicing, callibration, testing of 100 KVA to 1000 KVA, 11 KV/415 V transformer including cleaning servicing and connection tighting and conducting following tests:- (a) Ratio Test (b) Vector Group Test (c) Winding Insulation Test (d) HT bushing set (e) LT bushing set (Notes : The work shall be executed by through OEM or their authorised rep. The spares required to be replaced shall be paid and measured separately)
S&F in replacement of square dial PT operated flush pattern digital Volt meter 0-20 KV scaled operated with three way On/OFF roatry slector switch suitable for HT 11 KV VCB complete all as specified and as directed by Engr-in-Charge
S&F in replacement frequency meter digital type suitable for HT 11 KV VCB complete all as specified and as directed by Engr-in-Charge
Supply & fix in replacement One set of 3 Nos pilot lamp LED type for indicate On/Off Trip, 24 Volts DC complete all as specified and as directed by Engr-in-Charge
M & L for supply, installation and testing for Earthing complete with galvanised steel earth plate electrode 60×60Cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to but using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 shown in SSR Part-I 2009 connected to earthing test point complete all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-charge. (Note : Rate is inclusive of GI strip upto 7.5mtr length and beyond 7.5 mtr shall be measured and paid separately)
Nexus Infratech
M/S - KRUPA ELECTRICALS
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .