Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹15.7 L+₹2.0 L (14.5%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹16.8 L+₹3.1 L (22.6%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹17.0 L+₹3.2 L (23.4%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L5₹17.0 L+₹3.3 L (24.0%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L5 | Rejected-Finance Not a lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Dec 2023, 6:00 pmClosed
CWE (AF) Gwalior
CWE (AF) Gwalior
REPAIR/MAINT OF HT 11KV VCB/OCB AND ALLIED WORKS AT AF STATION GWALIOR
2023_MES_626630_1
85068
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Gwalior
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) ADM AREA GWALIOR
₹40,000
Yes
30 Jan 2024
3 Nov 2023
20 Dec 2023
3 Nov 2023
13 Dec 2023
29 Nov 2023
Amount
Disconnecting and taking out old unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of new digital Ammeter of size 96mmX96mm of range suitable for panel of 11 kV HT VCB complete all as specified and directed by Engineer-in -Charge.
Disconnecting and taking out old unserviceable Volt-meter of any description and in any position and supply, fixing, connecting, testing and commissioning of new digital Voltmeter of size 96mmX96mm of range suitable for panel of 11 KV HT VCB complete all as specified and directed by Engineer-in -Charge.
Disconnecting & taking out non-functional VCB of any description and any make of rating 11 KV, 800 Amps dismantling/opening of the VCB for servicing/overhauling, taking out and removing unserviceable/defective parts including cleaning and servicing, greasing, oiling of the parts, etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed by Engineer-in-Charge. (Note: - The quoted rate is deemed to include replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as "supply only")
Supply only following spare parts for 11 kV VCB 800 Amps capacity (of make Crompton Greaves) conforming to the respective cat part as existing : Note (i) Fixing and testing element of following item is deemed to be included under BOQ item No 3.00 here-in-before. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Supply only Vacuum interrupter with complete bottle
Supply only Isolating contact Assembly (Flower Type) With Ring
Supply only Big Gear
Supply only Small Gear
Supply only Fixed Botal contact
Supply only Flexible Contact
Supply only Epoxy Bushing Insulator
Supply only Motor and gear assembly for 230 volt AC
Supply only Rack-in and Rack-out gear
Supply only Rack-in and Rack-out Verm
Supply only Epoxy Resin Cast Bushing
Supply only Charging Assembly
Supply only Fixed Bushing
Supply only Epoxy mould without vacuum interceptor
Disconnecting & taking out non-functional VCB of any description and any make of rating 11 kV, 400 Amps/630 Amps dismantling/opening of the VCB for servicing/overhauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling /servicing and its testing complete all as specified and directed by Engineer-in-Charge. (Note: - The quoted rate is deemed to include replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as "supply only")
Supply only following spare parts for 11 kV VCB 400/630 Amps capacity of make (Crompton Greaves) conforming to the respective existing cat part : Note (i) Fixing and testing element of following item is deemed to be included under BOQ item No 5.00 here-in-before. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Supply only Epoxy mould without vacuum interceptor
Supply only Sleeves for Epoxy mould
Supply only Isolating Contacts (Flower Type)
Supply only Sleeves for Isolating Contacts
Supply only Closing shaft
Supply only Tripping shaft
Supply only Big Gear Assembly
Supply only Small Gear Assembly
Supply only Motor Cut off limit switch
Supply only Micro switch assembly (ZZ)
Supply only Breaker Control switch
Supply only Spring charging Motor 230 V AC
Supply only Segment Gear Assembly (square type).
Supply only Trips catch assembly
Supply only bus bar support insulator of suitable dia for 400/630Amp VCB.
Supply only Epoxy Bushing insulator for 11 kV (Drive rod )
Supply only ON/OFF push button Assembly
Supply only Charge Discharge indicator assembly
Supply only Auxiliary switch 7NO-7NC
Supply only Indicating lamps Red, Green, Amber white , 30 VDC
Supply only Indicating lamps Blue 230 VAC spring charging
Supply only Indicating lamps Red,Yellow,110 VAC
Supply only Indicating lamps Blue 110 VAC
Supply only NS HRC Fuse Links 2A,4A,6A,10A
Supply only Power pack Unit Gogate Electronics Make 230VAC/30VDC
Supply only Trip circuit healthy push button with auxiliary contact.
Supply only Local remote switch.
Supply only Spout insulator assy (Front) complete
Supply only Spout insulator assy (Back) complete
Supply only Spout contact (current carrying parts)
Supply only Vacuum Interceptor with complete bottle
Supply only CGI 14N Numerical Relay.
Supply only Trip circuit supervision relays, 30VDC.
Supply only Master Trip Relay 30 VDC.
Supply only copper strip for connecting cables and LT/HT bushings
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of cast resin type 11 kV current transformer having ratio of 300+150\5+5 A having protection core class 5P 10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 kV current transformer having ratio of 200+100/5+5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
Decarbonising\cleaning complete HT 11 KV 3 Phase busbar chamber of HT panel electrical connection rods complete HT VCB switch gear arrangement incoming and outgoing breaker after removing complete monoplast putty cleaning with CTC solution and ensure proper decarbonising refixing the same after applying beacon (red) insulating compound to the spout checking all connections tightening the nut and bolts washers of incoming and out going connections complete all as specified and directed by Engineer-In-Charge. Note : The rate is inclusive for replacement of worn-out bolts nuts & washers, lugs, glands, etc.
Testing of Numerical braker protections relay of various make of 11kV after dismantling of wiring and reassembling /refixing of the same complete all as specified and directed.
Testing of current transformer of various make of 11KV/33 KV, relay reassembling /refixing of the same complete all as specified and directed.
Testing of Auxiliary relay of various make of 11/33KV, relay reassembling /refixing of the same panels all as specified and directed
Dismantling and Taking out old Numerical relay wiring of any type and any description and replace wiring with 2.5 sq mm wire, wring materials, lugs, ferrules and cable tie and testing of Auxiliary relay of various make of 33/11KV panels all as specified and directed.
Dismantling of inter panel wiring, testing and checking of AC/DC supply and checking of Auxiliary relay of various make of 11/33 KV panels and reassembling/refixing and testing of the same complete all as specified and directed.
M&L for preparation of old painted surface of floor mounted indoor/outdoor type VCBs/RMUs/Control panels of any capacity/type by cleaning/rubbing with course cloth wire brushes to remove dust, deposits oil grease and painting with applying one coat of synthetic enamel paint (Ist quality) complete including SM No./MES No/Area feeded written on PVC flex rectangular board in the existing style/pattern/colour complete all as specified and directed.
Note: The quoted rate shall include cost of HT insulatiuon tape, Stainless steel nut, bolts and washers, use of CRC spray as per direction and requiremnet, cotton waste for cleaning purpose and other minor materials as directed by Engr-in-Charge.
M/s Anupam Construction Co.
Kumar Sales Corporation
Akarsha Enterprises
anand enterprises
UNIVERSAL AGENCY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .